Matter: Nova Scotia Power Inc. CI C0044172 – L7005 Canso Crossing Vibration Mitigation - $2,431,095 (P&A)2026 Q1 Capital Reports
4 passages 2 documents

Asset Management across all matters →

N-1CI C0044172 – L7005 Canso Crossing Vibration Mitigation - $2,431,095 - Redacted 2 passages
DESCRIPTION: p. p. 8
DESCRIPTION: This project is for the investigation, custom hardware development, testing, and installation of a new vibration dampening solution for the L-7005 transmission line across the Canso Strait. The new vibration mitigation system...

AI summary This project involves installing 288 custom PLP dampers and 1,164 PLP spoilers on the L-7005 transmission line across the Canso Strait to address fatigue-related failures from Aeolian vibration and galloping. Previous dampers failed due to unanticipated site conditions, including higher elevation and extended spans, exceeding original design assumptions.

Retirement Information: p. p. 8
Retirement Information: - Categorization of Retirement: Accounting Policy 6420 Retirement and Disposal of Capital Assets - Percentage of Asset Pool: 0.11%

AI summary The document discusses the categorization of retirement under Accounting Policy 6420, which governs the retirement and disposal of capital assets, and notes that 0.11% of the asset pool is affected, indicating a minor portion of assets being retired.

N-2CI C0044172 REFILE - Redacted 2 passages
REDACTED CI C0044172 Page 2 of 5 REDACTED (CONFIDENTIAL INFORMATION REMOVED) p. p. 7
REDACTED CI C0044172 Page 2 of 5 REDACTED (CONFIDENTIAL INFORMATION REMOVED) Estimated Life of the Asset: 45 years JUSTIFICATION: Justification Criteria: Transmission Plant

AI summary The document provides an estimated life of 45 years for an asset and refers to the 'Justification Criteria' under the 'Transmission Plant' category, indicating the basis for the asset's evaluation.

REDACTED CI C0044172 Attachment 1 Page 50 of 247 p. p. 55
REDACTED CI C0044172 Attachment 1 Page 50 of 247 APPENDIX 1 DOCUMENT LIST 180- rev0 Nova Scotia – Canso Type test certificate Tests: visual examination, LATIF report 17LA00056 is type test.pdf No. 17/180 Rev. 0 dimensions, materials, missi...

AI summary This document lists a type test certificate for electrical components conducted in March 2017 by Salvi Test Laboratory. The tests included visual examination, dimensions, materials, galvanizing, and failure load. The dead-end tension clamp failed, but after redesign, it passed the test requirements according to IEC specifications.

Disclaimer: These summaries were generated by AI from the filings they describe. We take care to make them accurate, but errors are possible - and they aren't advice. Only the filings themselves are the record: if you're relying on something here, confirm it against the source documents or the Nova Scotia Energy Board's own record. Full disclaimer →