N-1-aNotice of Application and Direct Evidence - NSPI - REDACTED (Large File - 59 MB)
3 passages
Appendix C – Operating Maintenance and General Expense 5 Year Forecast Appendix D – Credit Rating Reports Appendix E - Dr. Roger A. Morin Exhibits Appendix F – Load Forecast Report Appendix G - Cost of Service Study Appendix H - Proposed T...
AI summary The document outlines various appendices related to a regulatory proceeding, including operating maintenance forecasts, credit rating reports, load forecasts, cost of service studies, proposed tariffs, and regulation changes.
27 2.4.2 Fuels Forecast 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 28 29 30 Fuel costs include the cost of solid fuels, oil, natural gas and purchased power, offset by the net proceeds from export energy sales and...
AI summary The document discusses NSPI's 2007 fuel forecast, including an increase in net electricity demand and associated fuel costs. It notes that 90% of NSPI's generation will come from fossil fuels and mentions compliance with an annual sulphur dioxide emission cap. The recent credit downgrade by S&P is not factored into 2007 costs, but may impact long-term fuel procurement.
5 7.5.1 System Peak 6 7 8 9 10 System peak is defined as the highest single hourly average demand experienced in a calendar year. It includes both firm and interruptible load. The system peak forecast is used for operations and generation...
AI summary System peak is defined as the highest single hourly average demand in a calendar year, used for operations, generation planning, and cost allocation. Forecasting involves predicting customer behavior and weather effects. Net System Peak is expected to grow from 2,143 MW in 2005 to 2,639 MW in 2015. Actual peaks in 2005 and 2006 were lower than forecasts due to milder temperatures and industrial shutdowns.
N-40RIRs Attachment SEB-NSPI - 2a, pt. 1 (Large File - 22 MB)
3 passages
SEASONAL CAPACITY Additional capacity, hereinafter referred to as "seasonal capacity," can be supplied on a year-toyear basis during the billing months of October through May provided the Consumer gives a minimum of two months written noti...
AI summary The document defines 'seasonal capacity' as additional capacity provided on a year-to-year basis during the October through May billing months. To obtain this capacity, consumers must provide the Company with at least two months' written notice, subject to the Company's determination of availability. The Company reserves the right to suspend delivery during system emergencies and is not obligated to construct additional facilities to meet seasonal capacity demands.
TERM The customer shall contract for a de:furlte amount of electrical capacity in kilowatts which shall be sufficient to meet maximum requirements, but in no event shall the contract capacity be Jess than 1, 000 KW. Contracts will be reqll...
AI summary The text outlines the contractual terms for electrical capacity, specifying that customers must contract for a minimum of 1,000 KW to meet their maximum requirements. It establishes a minimum initial contract period of two years, with a one-year notice requirement for termination. Provisions are included for existing customers changing requirements and the Company's right to extend initial contract periods. Additionally, the Company is not obligated to supply capacity beyond the contracted amount without mutual agreement.
Where: F = Fuel cost per kilowatt-hour included in base rate, rounded to the nearest one ten-thousandth of a cent. E = Total Projected system Fuel costs: (A) Fuel consumed in the Utility's own plants and the Utility's share of fuel consume...
AI summary The text defines the components used to calculate the fuel cost per kilowatt-hour included in the base rate. It specifies that total projected system fuel costs consist of three components: (A) fuel consumed in the Utility's own or jointly owned plants, including fossil fuel costs and emission allowances; (B) fuel costs for purchased power like unit and limited-term purchases, including 'firm generation capacity purchases' to address capacity deficiencies; and (C) fuel costs for purchased power on an economic dispatch basis, including transmission charges and economy purchases.
N-40RIRs Attachment SEB-NSPI - 2a, pt. 4 (Large File - 19 MB)
3 passages
1. DURJNG A LEVEL 2 CAPACITY CURTAILMENT PERJOD For the maximum Curtailable Demand registered or computed by or from Company's metering facilities, during a Level 2 Capacity Curtailment Period, Customer's monthly bill will be increased sub...
AI summary The text outlines the billing structure for customers who have contracted to curtail demand during a Level 2 Capacity Curtailment Period. It specifies a tiered pricing model where the discount per kW increases by 10% for the second use and 20% for subsequent uses within a billing month. The calculation also accounts for the duration of the contract and the history of the customer's Curtailable Demand over the preceding 11 months, including provisions for credits and exclusions for Level 1 curtailment periods.
PLUS (B) Fuel costs related to purchased power and applicable S02 emission allowances such as those incurred in unit power and limited term power purchases where the fossil fuel costs and applicable S02 emission allowances associated with...
AI summary The text defines the scope of 'PLUS' costs, specifically focusing on fuel costs associated with purchased power and SO2 emission allowances. It specifies that these costs must be identifiable in billing statements for unit and limited-term power purchases. Additionally, it defines 'firm generation capacity purchases' as costs incurred to address capacity deficiencies or maintain reserve levels, explicitly excluding certain reservation and option charges.
AVAILABILITY This Rider is available only in conjunction with Company's Lighting and Power (LP) or Large Lighting and Power (LLP) rate schedules to Customers who contract for not less than 1000 kW of curtailable power. The applicable rate...
AI summary This section outlines the eligibility and limitations for a specific Rider related to curtailable power. It is available only to customers contracting at least 1000 kW of curtailable power under Lighting and Power or Large Lighting and Power rate schedules. Key constraints include a single point of delivery, exclusion of backup power for customer-owned generation, and a capacity limit of 5% of the Company's projected aggregate peak demand. Customers must also ensure that curtailment does not cause damage or impact public safety.
N-40RIRs Attachment SEB-NSPI - 2a, pt. 3 (Large File - 23 MB)
9 passages
Availability of Service. Available for interruptible service to customers operating at 34,500 volts or higher if the Company has surplus capacity in operative generating equipment, transmission lines, and principal substation transformers...
AI summary The document outlines the conditions under which interruptible service is available to customers operating at 34,500 volts or higher. Service is contingent upon the Company having surplus capacity in its generating equipment, transmission lines, and principal substation transformers that exceeds the requirements of other customers. Customers must contract for sufficient capacity to meet normal maximum requirements, with a minimum contractual capacity of 10,000 kVA.
Terms of Contract. The Company reserves the right to limit the total contract capacity for all customers served under this tariff to 100,000 kVA. (Cont'd on Sheet No. 14.3) ISSUED BY COULTER R. BOYLE, III VICE PRESIDENT FORT WAYNE, INDIANA...
AI summary The document outlines the terms of contract for a specific electric service tariff, noting that the Company reserves the right to limit the total contract capacity to 100,000 kVA for all customers served under this tariff. The document was issued by Coulter R. Boyle, III of Atlantic Power under the authority of the Indiana Utility Regulatory Commission and became effective on December 23, 1997.
Agers, Donna From: jrw : [email protected] Sent: F Friday, December 08, 2006 8:32 AM To: Agers, Donna Subject: Re: Kentucky Power Adjustments Hi Donna, The fuel adjustment, environmental and net merger credit factors are the same for all cu...
AI summary Donna Agers received a correspondence from Atlantic Power (AEP) regarding Kentucky Power adjustments. The communication clarifies that fuel adjustment, environmental, and net merger credit factors apply uniformly across residential, commercial, and industrial customer classes. It further specifies that residential customers are subject to additional surcharges, including a Home Energy Assistance fee of ten cents per month, a capacity charge, and a demand-side management factor, excluding school taxes or franchise fees.
Month Fuel Adj (/kWh) Capacity Net Merger DSM (/kWh) HEA (per meter) Charge(/kWh) Credit (/kWh) (/dollar) January 06 .0024319 .000847 000595 .000472 .10 .072271 April 06 .0028528 .000824 000595 .000248 .10 003053 July 06 .0072478 .000824 0...
AI summary The provided text is a data table presenting monthly values for various utility charges and adjustments for the year 2006. It includes specific rates for Fuel Adjustment (/kWh), Capacity charges and credits, Demand Side Management (DSM) costs, Home Energy Assessment (HEA) costs per meter, and Net Merger values. The data points are listed for January, April, July, and October of 2006.
TERM OF CONTRACT Contracts under this tariff will be made for an initial period of not Jess than 5 years and shall remain in effect thereafter until either party shall give at least 12 months' written notice to the other of the intention t...
AI summary This section outlines the contractual terms for services under the tariff, establishing a minimum initial contract period of five years. It specifies that contracts remain in effect until 12 months' written notice is provided by either party. The Company maintains the right to require longer initial contract periods if new facilities are necessary. Furthermore, it clarifies that existing customers increasing requirements do not need to restart their initial period unless new facilities are required, and the Company is not obligated to supply capacity beyond contracted amounts without mutual agreement.
curtailment periods. c c T 3rd Revised Sheet No. I'M7.10 Canceling 2nd Revised Sheet No. N-4 7.1 0 Rider No. 57 to Electric General Service and Large General Service· Curtailment Service (can't) Option B customers may request a change in t...
AI summary The text outlines the terms for Rider No. 57 (Curtailment Service) for Electric General Service and Large General Service. It specifies procedures for customers choosing Option A or Option B regarding firm power level changes and service cancellations. Key provisions include the forfeiture of credits upon cancellation for Option B, the Company's requirements for accommodating firm power increases, and the methodology for verifying and adjusting curtailable load based on historical demand during curtailment periods.
Rider No. 57 to Electric General Service and Large General Service- Curtailment Service (con't) customer, provided the customer was alerted to the possibility of curtailment 12 or more hours prior to the beginning of the curtailment period...
AI summary The text outlines the operational rules for Rider No. 57, which governs the Curtailment Service for Electric General Service and Large General Service. It specifies notice requirements for curtailments intended to avoid MAPP capacity purchases (12 hours notice, with a 2-hour minimum) and those due to operating conditions. It also defines the maximum duration of curtailment periods, the annual limit of 16 such periods during summer peak months, and the methodology for randomly rotating curtailable groups. Finally, it establishes a statewide limit of 190,000 kW for total curtailable load.
Rider No. 2 to Electric General Service and Large General Service (Except Price Schedule LCL) -Curtailment Service (can't) Option B customers may request a change in the firm power level annually. In addition, on 24 hours' notice, customer...
AI summary This document outlines Rider No. 2 for Electric General Service and Large General Service regarding Curtailment Service. It details two options for customers: Option B allows for annual firm power level changes and 24-hour service cancellation (with forfeiture of summer credits), while Option A requires immediate notification for increases. The Company reviews expected loads annually and may adjust minimum firm power levels based on historical demand. It also includes provisions for standby generators, minimum billing, and tax adjustments.
Rider No.2 to Electric General Service and Large General Service (Except Price Schedule LCL) -Curtailment Service (con't) r customer, provided the customer was alerted to the possibility of curtailment 12 or more hours prior to the beginni...
AI summary The text outlines the operational procedures for Rider No.2 Curtailment Service, specifically regarding notice periods and duration for load curtailment. It specifies that customers must be notified 12 hours in advance, unless the Company provides 2-hour notice to avoid MAPP capacity purchases. Curtailment periods are capped at 6 hours or until notice of termination. The Company will randomly group participants by net C loads and rotate between groups. Participation is limited to a state-wide total of 190,000 kW.
57966Supplementary Board Order
2 passages
OP - Organization Profile - 1 . Latest regulated annual reports of NSPI and EMERA. - 2. Current organization chart of NSPI showing all positions reporting no further than two levels down from the President and CEO, including a full organiz...
AI summary The document outlines a list of information requests related to Nova Scotia Power Inc. (NSPI) and EMERA, including financial reports, organizational structure, asset details, maintenance schedules, fuel specifications, reliability statistics, customer data, and compliance with emissions targets.
ponent of the fuel price, so that the final plant-delivered cost is that used as input to the Strategist run. Include sources used to derive the requested data, and the date the forecast was prepared. - (I) Provide a summary of the current...
AI summary The text outlines a series of requests related to fuel transportation contracts, hedging programs, fuel supply studies, and fuel-related affiliate transactions. It also includes requests for data on gas usage, export and import power calculations, and cost and recovery calculations for fuel resale.