Topic/Matter Intersection

Topic:"Commercial Industrial Programs" in M06319

Matter: P-886 Nova Scotia Power Inc. (NSPI) Rate Application 2007
23 passages 9 documents

Commercial Industrial Programs across all matters →

N-1-aAppendix H - Proposed Tariffs (Large File - 21 MB) 5 passages
AVAILABILITY:
AVAILABILITY: This tariff is applicable to electric power and energy supplied to any customer, for industrial use, including farming and processing, where the regular billing demand is less than 250 kV.A or 225 kW.

AI summary The text defines the scope of applicability for a specific tariff. It applies to customers using electric power and energy for industrial purposes, which specifically includes farming and processing operations. The eligibility is restricted to customers whose regular billing demand is below the threshold of 250 kV.A or 225 kW.

LARGE INDUSTRIAL TARIFF
LARGE INDUSTRIAL TARIFF (2 000 kV.A or 1 800 kW, and Over) Rate Code 23

AI summary The document defines the scope of the Large Industrial Tariff, specifically identifying it as Rate Code 23. This tariff applies to large industrial customers with a demand of 2,000 kVA or 1,800 kW and over.

AVAILABILITY:
AVAILABILITY: This tariff is applicable to three phase electric power and energy supplied at the low voltage side of the bulk power transformer to any industrial customer having a regular billing demand of 2 000 kV.A or 1 800 kW, and over.

AI summary The document specifies the applicability criteria for a specific electricity tariff. It applies to three-phase electric power and energy supplied at the low voltage side of the bulk power transformer. The target audience is industrial customers with a regular billing demand of 2,000 kV.A or 1,800 kW or greater.

AVAILABILITY:
AVAILABILITY: This tariff is applicable to three phase electric power and energy supplied at the low voltage side of the bulk power transformer to any industrial customer having a regular billing demand of 2 000 kV.A or 1 800 kW, and over.

AI summary The text defines the applicability of a specific tariff for three-phase electric power and energy. It specifies that the tariff is intended for industrial customers who receive supply at the low voltage side of the bulk power transformer and maintain a regular billing demand of at least 2,000 kV.A or 1,800 kW.

INTERRUPTIBLE RIDER TO THE LARGE INDUSTRIAL TARIFF (Rate Code 25)
INTERRUPTIBLE RIDER TO THE LARGE INDUSTRIAL TARIFF (Rate Code 25) Customers who qualify for interruptible service will receive a $3.43 per month per kilovolt ampere reduction in demand charge for billed interruptible demand. The billed int...

AI summary The text outlines the financial structure of the Interruptible Rider for the Large Industrial Tariff (Rate Code 25). Customers eligible for interruptible service receive a monthly credit of $3.43 per kilovolt-ampere (KVA) for billed interruptible demand. This demand is calculated as the difference between contracted firm demand and total billing demand, provided the billing demand is less than the contracted firm demand. The calculation for billed interruptible demand considers the maximum interruptible demand of the current month or specific months from the previous eleven-month period.

N-1-aAppendix F - Load Forecast Report (Large File - 16 MB) 6 passages
11 Forecast Models
11 Forecast Models 12 13 Nova Scotia electric energy sales are modeled and forecast as three provincial customer sectors: 14 residential, commercial and industrial. Energy forecasts for sector electricity sales are calculated 15 using econ...

AI summary The document describes the methodology for forecasting Nova Scotia's electric energy sales across three sectors: residential, commercial, and industrial. It utilizes multiple linear regression econometric models that correlate electricity consumption with independent variables such as population growth, inflation, GDP, and retail sales. Additionally, individual load survey information is used for large commercial and industrial customers. The models rely on data from the Conference Board of Canada's Economic Outlook to provide a provincial perspective on load growth.

20 Table 3 Commercial Sector Energy
20 Table 3 Commercial Sector Energy Year Commercial Sector GWh Growth Rate % 2000 2,829.4 2.3 2001 2,959.3 4.6 2002 2,996.5 1.3 2003 3,090.6 3.1 2004 3,187.8 3.1 2005 3,223.2 1.1 2006F 3,275.4 1.6 2007F 3,344.6 2.1 2008F 3,423.2 2.3 2009F...

AI summary The text provides historical data on commercial sector energy consumption in Nova Scotia from 2000 to 2015, showing consistent growth. It highlights that the industrial sector, which includes primary resources like mining and forestry and secondary industries like manufacturing, accounted for 36 percent of total electricity sales in 2005. Notably, a small number of large customers account for the majority of the sector's energy load, making the sector's demand highly sensitive to production and technological changes.

16 Table 4 Industrial Sector Energy
16 Table 4 Industrial Sector Energy Year Industrial Sector GWh Growth Rate% 2000 3,930.0 1.5 2001 3,872.5 -1 .5 2002 3,798.6 -1.9 2003 4,045.9 6.5 2004 4,212.1 4.1 2005 4,215.1 0.1 2006F 3,362.4 -20.2 2007F 4,388.4 30.5 2008F 4,438.0 1.1 2...

AI summary The document presents a historical data table detailing the energy consumption of the industrial sector in Nova Scotia from 2000 to 2015. It tracks the annual electricity consumption in Gigawatt-hours (GWh) and the corresponding annual growth rates. The data shows fluctuations in the early 2000s, followed by a period of steady growth of approximately 1.0% per year between 2010 and 2015.

11 Large General
11 Large General 12 - 13 This class compnses large commercial sector customers (malls, universities, hospitals, etc) - 14 whose regular maximum demand is 2,000 kVA or more. As of December 2005, there were 18 - 15 customers in this class re...

AI summary The document defines the 'Large General' customer class, which consists of large commercial sector entities such as malls, universities, and hospitals. Eligibility for this class is based on a regular maximum demand of 2,000 kVA or more. As of December 2005, the class included 18 customers, accounting for 3.6 percent of Nova Scotia Power Inc. (NSPI) sales, with an expected average annual load growth of 1.6 percent over the forecast period.

19 Extra Large Industrial Interruptible Rate (ELIIR)
19 Extra Large Industrial Interruptible Rate (ELIIR) 20 - 21 This rate is calculated annually in advance and based on NSPI' s budgeted base load costs. It is - 22 optionally available to, and currently in use by, two large industrial custo...

AI summary The Extra Large Industrial Interruptible Rate (ELIIR) is an annual rate based on Nova Scotia Power Inc.'s (NSPI) budgeted base load costs. It is available to large industrial customers who commit more than 20 MW of load and are served at 138KV or more. The rate is designed to reward high monthly load factors and includes an economic interruptibility provision, with priority interruptibility from a supply perspective. ELIIR accounted for approximately 16 percent of NSPI sales in 2005 and is scheduled to be replaced in 2007.

Industrial Econometric Model Details
Industrial Econometric Model Details Small and Medium Industrial Classes are summed and modeled together. SM_{IND} = 0.009305 RQTOS + 0.7441 SM IND_{-1} - 28.69 MIGRATE

AI summary The document describes the econometric modeling used to forecast demand for Small and Medium Industrial customer classes. It specifies that these classes are aggregated for modeling purposes. The model for these classes is defined by a regression equation incorporating Real Quarters to Sales (RQTOS), the previous period's Small and Medium Industrial demand (SM IND_-1), and a migration factor (MIGRATE).

N-2-dRIRs 1 to 46 - CME to NSPI - REDACTED (Large File - 18 MB) 1 passage
RESPONSE TO INFORMATION REQUEST
RESPONSE TO INFORMATION REQUEST TO: NSPI FROM: CME Question IR-25: Reference Page 113, Lines 13-20 Provide examples of industrial-commercial users that have been lost and the magnitude of the losses for each customer where these users have...

AI summary Campbell Scott Management (CME) responded to an Information Request (IR-25) from Nova Scotia Power Inc. (NSPI) regarding the loss of industrial-commercial users. CME clarified that the evidence provided does not contain specific historical examples of lost customers or the magnitude of those losses. Instead, the referenced section in Dr. Morin's evidence focuses on general risk factors and investor perceptions rather than specific past events.

N-40RIRs Attachment SEB-NSPI - 2a, pt. 1 (Large File - 22 MB) 1 passage
APPLICABILITY
APPLICABILITY Applicable to high load factor industrial power service requiring 3,000 kW or greater and having a demonstrable annual load factor of approximately ninety percent (90%) or greater. Service shall be taken at one (1) voltage an...

AI summary This section outlines the specific applicability criteria for a high load factor industrial power service. It is designated for industrial customers requiring 3,000 kW or greater with an annual load factor of approximately 90% or greater. Requirements include service at a single voltage and delivery point, a prohibition on combining service to multiple premises, and a ban on reselling or sharing service. Additionally, the Company maintains the right to negotiate specific terms for loads exceeding 27,000 kW capacity, subject to Alabama Public Service Commission approval.

N-40RIRs Attachment SEB-NSPI - 2h 1 passage
Section 37
hllp://www.lqeenergy.com/bsc/ku/rates tariffs.asp LCI • TOD: Effective 7/5/05 Curtailable Service Rider CSR 2: Effective 711/04 Voltage: Transmission Power Factor. 90% Assumes Substation Ownership Large CommerciaVIndustrial Time-of-Day

AI summary The text provides specific technical parameters and effective dates for various electricity service riders and rates, including the LCI • TOD, Curtailable Service Rider CSR 2, and Large Commercial/Industrial Time-of-Day rates. It specifies a 90% Transmission Power Factor and notes assumptions regarding substation ownership.

N-40RIRs Attachment SEB-NSPI - 2a, pt. 2 (Large File - 15 MB) 2 passages
APPLICABILITY
APPLICABILITY Available to all commercial and industrial customers who contract for a specified capacity (Minimum Contract Capacity), commensurate with customer's normal firm load requirements, but in no case less than 5,000 kilowatts of c...

AI summary The text outlines the eligibility criteria for a specific service or program, stating it is available to commercial and industrial customers. To qualify, customers must contract for a Minimum Contract Capacity based on their normal firm load requirements, with a minimum threshold of 5,000 kilowatts. Additionally, the service requires all electricity to be delivered at a single point of delivery designated by the Company through one meter.

9.8. SERVICE REGULATIONS
9.8. SERVICE REGULATIONS (MT, RT) Service under this schedule is subject to Policy Schedule No. 9, Service Regulations, of the Company as it is now on file, and as it may in the future be filed, with the APSC and the rules of the Commissio...

AI summary The document fragment outlines the service regulations governing the Optional Interruptible Service Rider (Schedule 41) for Entergy Arkansas, Inc. It specifies that service is subject to the Company's Policy Schedule No. 9, Service Regulations, as filed with the Arkansas Public Service Commission (APSC) and the Commission's rules. The service is categorized for Commercial/Industrial electric customers.

N-40RIRs Attachment SEB-NSPI - 2a, pt. 5 (Large File - 20 MB) 4 passages
Preamble
APPLICABLE: To all commercial and industrial electric service supplied at one point of delivery, and measured through one kilowatt-hour meter, where facilities of adequate capacity and suitable voltage of 69 kV or higher are adjacent to th...

AI summary This document outlines the commercial and industrial electric service rates for a Texas service territory. It specifies demand charges based on kilowatt (kW) usage, energy charges per kilowatt-hour (kWh), and terms of payment including late fees. Additionally, it defines the methodology for determining demand and establishes a power factor adjustment based on reactive demand relative to measured kW demand.

Features
Features FPI gives qua Lified industrial customers with lo:~ds above 1,000 kilowatts a fixed credit from firm dem<~nd charges in exchange for interruption rights with a 5 minute suspension notice . Up to 100% of lmd may be taken as FPI.

AI summary The text describes the features of the Flat Price Interruptible (FPI) service, which is available to qualified industrial customers with loads exceeding 1,000 kilowatts. Under this arrangement, customers receive a fixed credit on their firm demand charges in return for granting the utility interruption rights, provided a 5-minute suspension notice is given. The document specifies that up to 100% of the load may be designated as FPI.

Requirements
Requirements FPI is available to SIC-qualified customers with regular requirements of more than 1,000 kW at a single point of delivery.

AI summary The text specifies the eligibility requirements for the Flat Price Interruptible (FPI) service. To qualify, customers must be SIC-qualified and maintain regular requirements exceeding 1,000 kW at a single point of delivery.

Power - Standard
Power - Standard APPliCABILITY: To large commercial and industrial loads served through customer-owned transformation as an alternative to General Service - Standard rates. Recorded Demand - The monthly recorded demand shall be the greater...

AI summary The text defines the applicability and demand recording methodology for the 'Power - Standard' rate. This rate is intended for large commercial and industrial loads served via customer-owned transformation as an alternative to General Service - Standard rates. It specifies that monthly recorded demand is determined by comparing the maximum kV.A demand between 07:00 and 22:00 hours on weekdays (excluding holidays) against 55% of the maximum kV.A demand recorded at any other time during the month.

N-40RIRs Attachment SEB-NSPI - 2a, pt. 3 (Large File - 23 MB) 2 passages
ELECTRIC RATE SCHEDULE LCI-TOD
ELECTRIC RATE SCHEDULE LCI-TOD Large Commercial/Industrial Time-of- Day Service

AI summary The document fragment introduces the Electric Rate Schedule LCI-TOD, which pertains to Large Commercial/Industrial Time-of-Day Service. It serves as a heading for specific rate structures and service terms applicable to large-scale commercial and industrial customers who utilize electricity on a time-of-day basis.

AVAILABILITY OF SERVICE
AVAILABILITY OF SERVICE Available to industrial and large commercial customers. Customers shall contract for a definite amount of electrical capacity in KW which shall be sufficient to meet normal maximum requirements but in no case shall...

AI summary The text outlines the availability of service for industrial and large commercial customers, specifying that these customers must contract for a definite amount of electrical capacity in KW. The contracted capacity must be sufficient to meet normal maximum requirements and is subject to a minimum threshold of 3,000 KW. Furthermore, contract capacities must be specified in multiples of 100 KW.

N-46Rebuttal Evidence of NSPI - Appendix A to J - REDACTED (Large File 27 MB) 1 passage
Tier StoraEnso Bowater
Tier StoraEnso Bowater MW in tier of annual % decrement MW in tier of annual % decrement energy energy Tier 1 (@100% ofMC1 ) 75MW 82 % 30MW 93 % Tier 2 (@80% or SECL) 30MW % 10 10MW 6 % Tier 3 (@60% or SEC) Balance 95 MW) 8 % Balance 2MW)...

AI summary The document provides a comparison of energy load and annual percentage decrements for two industrial entities, StoraEnso and Bowater, across three tiers. Based on 2005 data, the analysis calculates the load-weighted average percent of marginal cost, which is 95 percent for StoraEnso and 98 percent for Bowater. The data outlines specific megawatt (MW) capacities and corresponding energy decrement percentages for each tier.

Disclaimer: These summaries were generated by AI from the filings they describe. We take care to make them accurate, but errors are possible - and they aren't advice. Only the filings themselves are the record: if you're relying on something here, confirm it against the source documents or the Nova Scotia Energy Board's own record. Full disclaimer →