E-3ENSC 2011 DSM Evaluation Report prepared by Econoler
11 passages
Efficiency Nova Scotia Corporation 2011 Evaluation Report C: It would be useful to know what kind of arrangement there is between the building administration and the low-income renter (for each building) in regards to the method of sharing...
AI summary The text discusses questions and comments related to the evaluation of a program by Efficiency Nova Scotia Corporation, focusing on cost-sharing arrangements between building administrations and low-income renters, process evaluation, program theory, and barriers addressed by the program. It also asks about evaluation plans, marketing strategies, and data management challenges.
r EnerGuide point coefficient. As mentioned previously, the sample project simulations include at least one of each prescriptive measure. Starting with the HOT2000 simulations created by the energy Ref.: 5725 40 EnerGuide for Existing Hous...
AI summary The document discusses the evaluation of the EnerGuide for Existing Houses Program, focusing on the impact of various prescriptive measures on electricity consumption in HOT2000 simulations. It highlights that only certain measures, such as solar DHW and electric hot water heater tank wrap, resulted in reduced electricity consumption when electrical space heating was involved.
Efficiency Nova Scotia Corporation 2011 Evaluation Report 1.1.2 Program Eligibility As stated in its program manual, project sites eligible to participate in the C&IC program must be institutional, charitable, commercial or industrial faci...
AI summary The C&IC program by Efficiency Nova Scotia Corporation (ENSC) allows institutional, charitable, commercial, and industrial facilities served by Nova Scotia Power Incorporated (NSPI) with a peak demand of 250 kW or higher to participate. Projects must save at least 20 MWh annually and cannot include non-utility energy sources. Eligible measures include lighting and HVAC systems, while demand limiting controls and cogeneration are ineligible.
cation partner who reviews energy model submissions and provides technical assistance to program participants did not have much experience with the program (three months) at the time of the interview. The level of satisfaction of the verif...
AI summary A verification partner expressed high satisfaction with the CINC program despite some initial challenges, including the need for developing guidelines and improving software tools. The partner highlighted the importance of collaboration with ENSC's team and suggested enhancements such as adding a commissioning component and calibrating modeling tools. Approximately 44% of respondents had previously participated in other NSPI or ENSC programs.
oreover, the Evaluator defined the chiller operation schedules with the customer, which helped estimate the operation hours as well as the diversity factors to be used for energy savings calculations. Finally, the Evaluator established tha...
AI summary The Evaluator established that the chiller operation schedules had no significant impact on heating or cooling loads. Additionally, a 2011 retrofit project replaced inefficient UPS systems, with ENSC confirming installation and assuming energy savings were realized, though more detailed M&V was planned for later.
sured was the pre- and post-retrofit wattage of the lighting fixtures. With this in mind, the Evaluator encourages ENSC to organize trainings on M&V and the IPMVP for C&IC program staff. > Record the diversity factors used for peak demand...
AI summary The text discusses issues with diversity factors used in peak demand savings calculations for the C&IC program, highlighting that ENSC used conservative factors that did not reflect actual conditions. It recommends training on M&V and IPMVP, and recording diversity factors and their rationale for future evaluations.
Impact 20. Clearly define the M&V requirements before signing the PDA: The Evaluation Evaluator noted that most of the projects do not have a dedicated M&V plan even though M&V was considered as complete and approved. The Evaluator recomme...
AI summary The document emphasizes the need for clearly defined M&V requirements in the PDA and recommends the development of M&V plans early in the project process. It also suggests that ENSC consider third-party M&V for projects where the implementation firm is already conducting M&V, to ensure compliance with IPMVP standards.
construction project. This new building was to be used for retailing luxury cars of a brand that had its specific and non- negotiable standards for indoor lighting level and technology. The former program participant told the Evaluator tha...
AI summary A program participant decided not to apply for the CINC program due to inability to meet lighting power density requirements. The Evaluator recommends developing a methodology to allow partial compliance with CPG for new constructions and adjusting incentives accordingly, while ensuring compliance with a minimum number of Core Performance Requirements.
the source of awareness in order to establish which ones were the most effective. 2 The program offers three types of technical Selecting the right path will be captured in assistance: modeling validation by an each project file. As for ed...
AI summary The program provides technical assistance and incentives for energy efficiency measures. It includes modeling validation, educational activities, and incentives based on the chosen path. Tracking of activities and incentives is emphasized to evaluate effectiveness and measure savings.
ere 1= ‘not at all important’ and 5 = ‘very important’, how important is reducing energy usage to your company or organization? [98 = Don’t know, 99 = Refused] do not accept a range B5. On a scale of 1 to 5, where 1= ‘not at all important’...
AI summary The text includes survey questions about the importance of reducing energy usage and managing energy costs for companies, as well as inquiries about the percentage of annual operating budgets attributed to energy costs and suggestions for improving the Custom Program. It also asks if a visual guide would have helped with program participation.
energy usage of the plant even in the absence of any energy efficiency projects. The following sections describe the main inquiries that were analysed during interviews. Feedstock Material Variation Raw material characteristics are mandato...
AI summary The document discusses the importance of accounting for feedstock material variation in energy efficiency assessments. It highlights that raw material characteristics must be analyzed to avoid misinterpreting energy changes as savings. The EPS report was criticized for not addressing these factors, and the plant lacks precise tracking of raw material inputs.
120102012 DSM Evaluation Reports
3 passages
3.3 HOT2000 SIMULATION REVIEW The first point noticed during the HOT2000 simulation review was the high variability in professionalism and training found between DAs. Some of these organizations presented very accurate files that displayed...
AI summary The HOT2000 simulation review identified significant variability in the quality of work among delivery agents (DAs), with some producing accurate files and others making recurrent errors such as omissions, incomplete information, and calculation mistakes. Econoler recommends that ENSC implement a continuous review process to improve simulation quality and address training needs.
3.5.1 Perceptions Related to Program Changes A total of three DAs and three EAs were interviewed for the evaluation of Performance Plus. The program partners were asked, among other things, about their general satisfaction with the program...
AI summary Interviews with Distribution Agents (DAs) and Energy Advisors (EAs) revealed high satisfaction with the Performance Plus program, though some improvements were suggested, including better alignment of incentives with costs, increased public education, and expanded coverage of energy efficiency upgrades.
icture_0.jpeg) was not filled out and the information had to be collected with the specifications sheets of the new heat pumps installed. One kind of recurrent adjustment made was the correction of HSPF values. For half of the verified pro...
AI summary The document discusses issues with the calculation of HVAC savings, particularly the adjustment of HSPF values for colder climates and the use of incorrect formulas or values in some projects, leading to overpredicted savings. It also notes that full load hours were estimated by participants, with Econoler preferring typical values from Efficiency Vermont.