Topic/Matter Intersection

Topic:"Energy Efficiency Resource Assessment Model" in M06319

Matter: P-886 Nova Scotia Power Inc. (NSPI) Rate Application 2007
53 passages 15 documents

Energy Efficiency Resource Assessment Model across all matters →

N-1-aNotice of Application and Direct Evidence - NSPI - REDACTED (Large File - 59 MB) 7 passages
20 Petroleum Coke Markets
20 Petroleum Coke Markets 21 Petroleum coke (pet coke) is a by-product of the coking process that is used by 22 some refineries in order to extract additional light oil. Pet coke has a high 23 carbon content and low volatility and, if the...

AI summary Petroleum coke (pet coke) is a by-product of oil refining with high carbon content and low volatility, primarily used in cement kilns and power plants. Pet coke production has grown significantly in recent years, particularly in the Gulf of Mexico. Its price is highly volatile due to its status as a by-product, with supply not responding much to price changes.

Figure 7.3
Figure 7.3 The residential forecast model is an end-use/econometric hybrid. The end-use model incorporates changes to household appliance loads based on appliance average use, maturity rates, efficiency improvements, market saturation and...

AI summary The residential forecast model combines end-use and econometric methods to predict appliance usage and heating trends. It considers factors such as appliance efficiency, market saturation, and fuel price ratios. The model forecasts increasing use of electric space and water heating, and uses retail sales data as an economic indicator for forecasting.

Figure 7.4
Figure 7.4 Residential Sector Forecast Accuracy Year Forecast GWh Actual GWh %Variance 1998 3,672 3,524 4.0 1999 3,606 3,512 2.6 2000 3,636 3,672 (1 .0) 2001 3,776 3,741 0.9 2002 3,904 3,829 1.9 2003 3,958 4,011 (1.3) 2004 4,107 4,114 (0.2...

AI summary Figure 7.4 presents a comparison of forecasted and actual electricity consumption in the residential sector from 1998 to 2005, showing the percentage variance between the two. The data indicates that forecasts were generally accurate, with small variances across the years.

3 7.4.3 Industrial Sector
3 7.4.3 Industrial Sector 4 5 The industrial sector includes customers who manufacture finished goods, or who process 6 material to produce a product of higher value. This includes fish plants, pulp and paper 7 mills, mines, tire manufactu...

AI summary The industrial sector in Nova Scotia includes manufacturers and processors that account for 34% of in-province energy use. Load forecasting uses econometric modeling and customer surveys, especially for large industrial customers influenced by external factors like foreign exchange rates and international demand. Forecast accuracy is shown in Figure 7.10, with industrial sales being relatively insensitive to weather.

21
21 Industrial Sector Year GWh %growth Yr/Yr 1998 3,442 20.1 1999 3,872 12.5 2000 3,930 1.5 2001 3,873 (1 .5) 2002 3,799 (1 .9) 2003 4,046 6.5 2004 4,212 4.1 2005 4,215 0.1 2006F 3,362 (20.2) 2007 4,388 30.5 Major plant expansions contribut...

AI summary The industrial sector's electricity consumption in Nova Scotia showed significant fluctuations between 1998 and 2007, with major growth in 2003-2004 due to plant expansions. A temporary shutdown and restart of a large industrial customer caused large swings in load growth for 2006-2007. The forecast for 2007 is 4,388 GWh, a 1.9% increase over 2006, after normalizing for the shutdown.

20 7.4.6 Total Requirement
20 7.4.6 Total Requirement The total energy requirement is the sum of the residential, commercial and industrial sectors as well as export sales and associated losses. Total requirement growth has averaged 1.8 percent per year from 2000-20...

AI summary The total energy requirement for 2007 is projected at 13,059 GWh, influenced by a temporary industrial plant shutdown that caused a drop in 2006 and a rebound in 2007. The long-term growth rate, excluding the shutdown, is 1.3 percent annually.

1 Figure 7.14
1 Figure 7.14 Total Requirement Year GWh %growth 1998 10,506 2.0 1999 11 ,079 5.5 2000 11 ,432 3.2 2001 11 ,646 1.9 2002 12,031 3.3 2003 12,329 2.5 2004 12,565 1.9 2005 12,483 (0.6) 2006F ,935 11 (4.4) 2007 13,059 9.4 2

AI summary The table shows the total electricity requirement in Nova Scotia from 1998 to 2007, with annual figures in gigawatt-hours (GWh) and percentage growth. The data indicates fluctuating growth rates, with a notable decline in 2006F and a significant increase in 2007.

N-1-aAppendix H - Proposed Tariffs (Large File - 21 MB) 2 passages
UET
UET This is the upper boundary in kW, as agreed to by both NSPI and the customer. The difference between this boundary and the LET defines the TD for the customer's ELIIR pricing during the active rate year. Any load reduction in any hour...

AI summary The text defines the Upper ELIIR Threshold (UET) as the maximum power boundary in kW agreed upon by Nova Scotia Power International (NSPI) and a customer. The difference between the UET and the Lower ELIIR Threshold (LET) determines the Time of Day (TD) for the customer's ELIIR pricing during an active rate year. Crucially, any load reductions occurring below the UET are excluded from the calculation of the Decremental Load Shift.

Customer's Alternative Cost (CAC)
Customer's Alternative Cost (CAC) This represents the customer's cost of energy for all load above the LET, and is calculated in the fall of each year preceding the active rate year using the Annual Hourly Load Shape and ELIIR only, or ELI...

AI summary The document defines the methodology for calculating the Customer's Alternative Cost (CAC), which represents energy costs for loads exceeding the Lower ELIIR Threshold (LET). Customers can choose between two modeling options: using the Energy Literacy and Inclusion Initiative (ELIIR) only, or a combination of ELIIR and 1P-RTP. The calculation involves determining the difference between the Upper ELIIR Threshold (UETcac) and the LET, applying average marginal costs for the 1P-RTP option, and summing these monthly costs to produce an annual figure.

N-2-aRIRs 1 to 39 - NSUARB to NSPI - REDACTED (Large File - 19 MB) 2 passages
Performance Factors OAF OR
Performance Factors OAF OR YTD 10-31 Forecast NSPI CEA NERC Plant 2005 2006 2007 00-04 00-04 00-04 PT. Aconi 1.28% 1.37% 3.00% 3.85% Tufts Cove # 1 Tufts Cove # 2 Tufts Cove# 3 0.32% 0.17% 3.05% 0.38% 0.12% 0% 2.00% 2.00% 2.00% 1.11% 2.10%...

AI summary The text presents a table comparing performance factors (OAF OR) across various plants, including PT. Aconi, Tufts Cove, PT. Tupper, Trenton, and Lingan, with data points such as HFO, NSPI, CEA, and NERC, highlighting differences in performance metrics over different years and periods.

Performance Factors Availability
Performance Factors Availability Annual Hours 8760 2005 YTD 10-31 Forecast 2006 2007 CEA 00-04 NERC 00-04 Plant PT. Aconi 93.80% 91 .10% 90% Tufts Cove # 1 Tufts Cove# 2 Tufts Cove# 3 84.50% 91.40% 90.30% 100.00% 92% 84.10% 92% 96.30% 87%...

AI summary The document presents performance factors availability for various plants, including annual hours and availability percentages for different years and forecasts. It compares data from 2005, 2006, 2007, and includes benchmarks from CEA and NERC. The CEA availability is calculated using the Industry Consensus Benchmark Factor (ICBF).

N-2-bRIRs 70 to 75 - NSUARB to NSPI - REDACTED (Large File - 33 MB) 8 passages
Question IR-72: Reference Appendix F
Question IR-72: Reference Appendix F - a. The title page of the Load Forecast report states Prepared September 2006. However, page 4, line 6 states it was prepared in the spring of 2006. In what month was the forecast prepared? - b. When i...

AI summary This section of the regulatory proceeding contains a series of questions directed at the Load Forecast report, focusing on discrepancies in dates, sources of data, and methodology for weather adjustments. The questions aim to clarify inconsistencies and obtain detailed explanations from the preparers of the report.

Response IR-72: (cont'd)
Response IR-72: (cont'd) Normal 2000 HDD 2005 HDD 2000 GWh 2005 GWh Month HDD Difference Difference MWh/HDD Difference Difference Jan 702.8 -35.7 72.1 359 -12.8 25.9 Feb 635.7 -29.8 -33.9 356 -10.6 -12.1 Mar 582.4 -75.6 -9.1 330 -24.9 -3.0...

AI summary The text presents a table comparing normal, 2000 HDD, and 2005 HDD values for each month, along with differences and corresponding GWh values. It is used to calculate weather-adjusted residential sector loads.

• Consumption levels
• Consumption levels Seven consumption levels were selected for analysis. However, data were collected for 21 consumption levels and those results are presented in the Detailed Tables.

AI summary The analysis involved seven selected consumption levels, although data were collected for 21 consumption levels, with results presented in the Detailed Tables.

Summary Table (excluding taxes)
Summary Table (excluding taxes) Residential General Small Power Medium Power Large Power Power Consumption Load factor 40kW 35% 500kW 1 ,000 kWh 1 0,000 kWh 1 00,000 kWh 28% 1,000kW 56% 2,500kW' 65% 5,000 kW' 400,000kWh 1,170,000 kWh 3,060...

AI summary The Summary Table (excluding taxes) presents power consumption load factors and associated costs for different power categories across various Canadian and American cities. The table includes data for residential, small power, medium power, and large power consumption categories, with specific load factors and costs listed for each city.

(inCA$)
(inCA$) General Small Power Medium Power Large Power Power Consumption Load factor 1,000 kWh 40kW 10,000kWh 35% SOOkW 100,000kWh 28% l,OOO,kW 400,000kWh 56% 2500,kW' 1,170,000 kWh 65% 5,000 kW' 85% 50,000 kW' 3,060,000 kWh 30,600,000 kWh 8...

AI summary The text presents a table comparing power consumption load factors and associated costs across various Canadian and American cities, categorized by power consumption levels. It includes data on load factors, energy consumption, and associated costs for different power tiers, with an emphasis on cities like Montreal, Halifax, and Vancouver, and highlights average values across all cities.

Summary Table (including taxes)
Summary Table (including taxes) Resldent1al General Small Power Medium Power Large Power Power Consumption Load factor 40kW 35% SOOkW 1 ,000 kWh 1 0,000 kWh 1 00,000 kWh 28% 1,000 kW 56% 2,500kW' 65% 5,000 kW' 400,000kWh 1,170,000 kWh 3,06...

AI summary The Summary Table (including taxes) presents power consumption load factors and comparative data for various cities in Canada and the United States, highlighting differences in energy consumption and load factors across different power categories and locations.

General - Small Power
General - Small Power Power Consumption Load factor 6kW 750 kWh 17% 14kW 2,000 kWh 20% 40kW 10,000 kWh 35% 100 kW 14,000 kWh 19% 100 kW 25,000 kWh 35% Canadian Cities Montreal, QC 74.58 178.33 842.33 1,583.80 2,358.00 Charlottetown, PE 115...

AI summary The document presents power consumption load factors and corresponding kilowatt-hour values for various kW levels across multiple Canadian and American cities, with an average provided at the bottom. It also notes that Hydro-Quebec has estimated bills for consumption levels of 250,000 kWh/year or more based on applicable general rates.

General - Large Power
General - Large Power Power Consumption Voltage Load factor 5,000 kW 25kV 65% 5,000 kW 2,340,000 kWh 3,060,000 kWh 25kV 85% 10,000 kW 120kV 80% 30,000 kW 5,760,000 kWh 17,520,000 kWh 23,400,000 kWh 30,600,000 kWh 120kV 81 o/o 50,000 kW 120...

AI summary The text provides a table of power consumption voltage load factors and associated costs for various Canadian and American cities, including Halifax, Montreal, Toronto, and Vancouver. The data includes kilowatt-hour consumption and associated costs at different voltage levels and load factors.

N-2-gRIRs 30 to 91 - SEB to NSPI - REDACTED (Large File - 29 MB) 2 passages
RESPONSE TO INFORMATION REQUEST
RESPONSE TO INFORMATION REQUEST TO: NSPI FROM: SEB REDACTED Question IR-41: Please provide a 5 year history (2002 through 2006 inclusive) of sources of energy for NSPI ( coal/petcoke, oil, gas, hydro, renewable, and purchases) as well as S...

AI summary The response to information request IR-41 provides a 5-year history (2002–2006) of NSPI's energy sources and SO2 emissions, including the percentage contribution of each energy source to total energy consumption during that period. The data is referenced in an attachment.

FOR THE YEAR ENDING DECEMBER 31, 2007
FOR THE YEAR ENDING DECEMBER 31, 2007 (1) TOTAL (2) (3) SMALL (4) (5) GENERAL (6) SMALL (7) MEDIUM (8) LARGE (9) EXTRA LI (10) (11) (12) ALLOCATION COMPANY DOMESTIC GENERAL GENERAL LARGE INDUSTRIAL INDUSTRIAL INDUSTRIAL INTERR 2 MUNICIPAL...

AI summary The document presents a detailed breakdown of various metrics, including demand, generation, and customer data, with percentages of responsibility across different categories and sizes. It includes tables with various factors and allocations, such as weighted totals and responsibility percentages, related to energy and utility management.

N-14Evidence filed by John Antonuk, Donald T. Spangenberg, Jr. and John B. Adger, Jr. (on behalf of NSUARB) (Large File - 26 MB) 4 passages
2007 Fuel Cost Review
2007 Fuel Cost Review - Volatility in market pnces for the fuels used for electricity generation has continued. - There is substantial reason to believe that this volatility will remain in the period during which NSPI will collect the rate...

AI summary The 2007 Fuel Cost Review highlights concerns about NSPI's assumptions regarding fuel costs and the risks of over- or under-recovery due to market volatility. It also criticizes NSPI's handling of excess natural gas sales and its selection of EES for purchasing gas, suggesting a lack of competitive processes and overly pessimistic assumptions.

A. Yes. For the years 2005, 2006 and 2007, NSPI's purchased power costs and forecast (CDN$ 000) are as follows:
A. Yes. For the years 2005, 2006 and 2007, NSPI's purchased power costs and forecast (CDN$ 000) are as follows: 2 6 2 Purchased Power Actual 2005 2006C Forecast 2007 3 Emera Energy 229.3 - - Brookfield 113.9 - - 4 Hydro Quebec 3,057.1 - -...

AI summary NSPI's purchased power costs for 2005, 2006, and 2007 are outlined, showing significant variations in expenses from different sources. Forecasted purchases for 2006 and 2007 are not under contract and are made on an hourly or daily basis to support the most economical operation of NSPI's generation fleet.

Natural Gas Marketing Strategy
Natural Gas Marketing Strategy Assisted a production-area storage developer in identifying prospective users of a proposed gas storage facility, and in marketing interests in the project. For National Fuel Gas Supply Corporation, analyzed...

AI summary The text outlines various consulting activities related to natural gas marketing, including market analysis, rate design studies, and strategy development for gas producers, marketers, and utilities. These efforts span North America and involve multiple stakeholders in the energy sector.

Strategic Analysis and Business Planning
Strategic Analysis and Business Planning Consultant on a merger-benefits study performed for an electric distribution cooperative and a local farmers' cooperative. Lead consultant on a business-enhancement project for a Rocky-Mountain-area...

AI summary The text outlines various strategic analysis and business planning projects conducted by a consultant for energy and utility companies, including merger-benefits studies, diversification planning, unbundling strategies, and evaluations of acquisitions and regulatory changes in the gas and electricity sectors.

N-16Review of NSPI's Fuel Costs on behalf of Avon Valley Greenhouses et al. (AVON) REDACTED (Large File - 38 MB) 10 passages
Preamble
5 2005 2001 2001 2000 2000 2000 2000 <sup>3 Coleman-Levin Report, p. A-7 <sup>4 P. Verleger, "Commodity Investors: A Stabilizing Force?" The Petroleum Economics Monthly, March 2006 <sup>5 (Available from http://www.cftc.gov. ) &lt...

AI summary The text discusses the speculative premium in commodity markets and references the Coleman-Levin Report and the IEA's Oil Market Report . It highlights the CFTC's efforts to increase market transparency by expanding its COT report and the IEA's stance on the role of fundamentals versus speculative activity in moving markets.

FIGURE 12 U.S. "STRANDED" DOMESTIC OIL RESOURCES IN EXISTING OIL FIELDS AND THE IMPACT OF C02 EOR TECHNOLOGY
bbls (Figure 15). According to the EIA, U.S. residual fuel oil (including HFO) in 2006 stood well above their historic average range (Figure 16). Source: EIA, International Petroleum Monthly November The EIA, in its annual Energy Outlook 2...

AI summary The text discusses U.S. residual fuel oil levels in 2006 and references the EIA's Energy Outlook 2007, which predicts a decline in world crude oil prices from $69 per barrel in 2006 to under $50 by 2014. It also notes that higher oil prices in 2006 would help non-OPEC suppliers retain and increase their market share through 2030.

Section 64
What in fact happened was quite different. Physical prices at Henry Hub peaked in October (the very month of the highest futures prices) with an average of US$13.54/ mmBtu. By November they had fallen to an average for the month of US$10.3...

AI summary Physical natural gas prices at Henry Hub peaked in October but fell significantly in November and continued to decline through 2006. A similar pattern was observed for natural gas export prices at St. Stephen, New Brunswick, during the same period.

Section 66
Well before the futures market failed to predict the behavior of gas prices after hurricanes Katrina and Rita, questions had been raised about the usefulness of using NYMEX natural gas futures prices to predict Henry Hub spot prices. A rep...

AI summary This text discusses the limitations of using NYMEX natural gas futures prices to predict Henry Hub spot prices, citing an EIA report from 2005 that found futures prices to be poor predictors of actual realized prices. The report highlights that futures prices reflect current market conditions and expectations, but are not reliable for long-term predictions, especially in a rate case context.

Section 88
Over the entire EU' s generating structure the impact of pricing in C02 emissions is very evident in the plans for new generation and in the plant that is currently under construction. The Power in Europe Survey of Plants Under Constructio...

AI summary The text discusses the impact of CO2 pricing on new power generation in Europe, highlighting the construction of gas CCGTs and the exception of new coal-fired plants in Germany. It notes that Germany's National Allocation Plan (NAP) allowed new coal plants to receive free emissions for the first eighteen years of their operation.

Section 94
Asia's seaborne steam coal demand growth has historically been dominated by three giant importers: Japan, South Korea and Taiwan. In 2005 Japanese imports declined, South Korea stayed approximately the same, and substantial growth was only...

AI summary Asia's seaborne steam coal demand growth has historically been driven by Japan, South Korea, and Taiwan, with significant growth in Taiwan in 2005. Lesser importers such as China and India also saw significant gains in steam coal imports during this time.

TABLE 32 NEW AUSTRALIAN STEAM COAL EXPORT CAPACITY UNDER DEVELOPMENT
TABLE 32 NEW AUSTRALIAN STEAM COAL EXPORT CAPACITY UNDER DEVELOPMENT Producer State Mine(s) Approx. incremental Capacity (mt) Rio Tinto NSW Mt Pleasant, Maules Creek 8-10 Anglo/Mitsui Qld Dawson complex 3.0 NSW Kyuga, Saddlers Creek 2-3 Xs...

AI summary Table 32 lists new Australian steam coal export capacity under development by various producers, including Rio Tinto, Anglo/Mitsui, Xstrata, and others, with approximate incremental capacities ranging from 1-15 million metric tons across different mines in New South Wales and Queensland. The total estimated capacity is approximately 87 million metric tons.

INTERNATIONAL STRATEGIC INFORMATION SERVICES {ISIS)
INTERNATIONAL STRATEGIC INFORMATION SERVICES {ISIS) For the past eighteen years, ISIS has focused its activities in these primary subject areas: • Independent power development and project acquisition, domestic and overseas Typical project...

AI summary ISIS has specialized in independent power development, fuel contract negotiation, and emissions trading for 18 years, with extensive experience in project acquisition, market assessments, and litigation. They have built databases of power and fuel supply contracts and operate globally, serving clients from North America, Asia, and other regions.

LIST OF RELEVANT COAL PROJECTS
W of coal-fired independent power project in Eastern Sumatra, Indonesia. - For the developers of the Pingshou coal project in China ongoing advise (1982-1989) on economic feasibility and coal prices. - •For several Japanese steel companies...

AI summary The text outlines various advisory and analytical services provided for coal-related projects and industries globally, including economic feasibility studies, price trend analyses, litigation support, and market assessments for coal and power sectors in multiple countries.

LIST OF RELEVANT INDEPENDENT POWER PROJECTS (IPP)
of a 60 mWe gas-fired industrial CHP plant in eastern Germany. - For an American IPP developer, preliminary due diligence for the privatization of an electricity distribution company (GZE) in Poland. - For an American IPP developer, prelim...

AI summary The text outlines various projects and due diligence activities undertaken by American and German IPP developers, including the acquisition and repowering of power plants, market analysis, and assistance with privatization and legal processes in multiple European countries.

N-30RIRs 1 to 15 - Nancy Brockway (on behalf of Consumer Advocate) to NS Attorney General (includes attachment to RIR 11) (Large File - 44 MB) 8 passages
D. Baseline and Participation Periods
D. Baseline and Participation Periods The baseline ("pre") and participation ("post") periods were selected to take advantage of the data available within Equitable's system, minimizing the use of archival tape libraries. The baseline year...

AI summary The baseline and participation periods were selected based on data availability within Equitable's system, covering full heating seasons and spanning a full year each. Billing cycles varied, leading to differences in calendar months across accounts, though seasonal variability is evident in the data.

NEWEAP
NEWEAP The new participant group comprised of customers who were not in EAP during the pre-period (the 12 month period prior to October 1, 1 993). This group entered EAP during the window from October 1, 1993 through March 31, 1994. 34In a...

AI summary The new participant group in the EAP consists of customers who joined between October 1, 1993, and March 31, 1994, and were not in EAP during the pre-period. This group was selected through a systematic random sampling method and is required to participate throughout the participation year to ensure robust data for hypothesis testing.

3. Comparison Group: Consumption
3. Comparison Group: Consumption Separately compute average consumption for the comparison group for the baseline year and for the time period of the defined participation year.

AI summary The text outlines a method to separately compute average consumption for a comparison group during the baseline year and the defined participation year.

4. Comparison Group: Gross Change
4. Comparison Group: Gross Change Compute the gross change in consumption by subtracting usage in the selected participation year from usage in the baseline year. 38Fels, M., The Princeton Scorekeeping Method: An Introduction. Princeton, N...

AI summary This section outlines the methodology for calculating the gross change in normalized energy consumption by comparing energy usage between the baseline year and the program year for both EAP participants and the comparison group of non-participants.

D. The Individual Case Analysis: ''Customer as Unit of Analysis"
D. The Individual Case Analysis: ''Customer as Unit of Analysis" The second analysis approach is a statistical approach which examines only the "clean" subset of cases. As before, the analysis looks at subsets of individual homes, examinin...

AI summary The second analysis approach focuses on a statistical examination of the 'clean' subset of cases, analyzing individual homes in participant and non-participant groups before and after the program. It uses a quasi-experimental design with a non-equivalent comparison group, maintaining individual homes as separate cases throughout the analysis to estimate consumption accurately on a customer level.

Preamble
the analysis. These cases have too few meter points for the individual customer level estimate of normalized consumption to be made. PRISM® was run in the 'regular' mode with outlier detection on. Detected outliers were rerun using the 'ro...

AI summary The analysis uses PRISM® to estimate normalized annual consumption, applying outlier detection and data quality screening. Outliers, often due to occupant behavior, are down-weighted, and poorly behaved cases are excluded to improve accuracy. This process reduces the number of cases analyzed but enhances the reliability of the results.

~
~ COMPARATIVE PERFORMANCE Col. 1 I Col. 2 I Col. 3 I Col. 4 I Col. 5 I Col. 6 I Col.? I I I Variable I Table IX-1: Comparative Net Back Ratio Results Group Customer Payments Grants Applied Overhead Other Costs Cost of Gas NBR 1989 Referenc...

AI summary Table IX-1 presents comparative Net Back Ratio (NBR) results for different groups, including the 1989 Reference, Baseline Pre-Period, EAP (Energy Affordability Program) for varying timeframes, Tuned EAP, and Standard Rate. The data includes customer payments, grants applied, overhead, other costs, cost of gas, and NBR values.

X. A Final Note
X. A Final Note As this study has demonstrated, Equitable's Energy Assistance Program (EAP) is successful. It works as planned. More importantly, it benefits participant customers, non-participant customers, Equitable, and society. The pra...

AI summary The study concludes that Equitable's Energy Assistance Program (EAP) is effective and benefits various stakeholders. The evaluation used multiple methods, including a 'Net-Back' approach, and findings were validated through repeated analysis with different data sets. The results are considered very solid, with no evidence of program abuse.

N-40RIRs 1 to 13 - Dr. Alan Rosenberg [SEB] to NSPI 2 passages
Question No. IR-4:
Question No. IR-4: Please provide the following information for each of the utilities listed in Exhibit AR-1: - a. Mix of fuels in 2005 as measured by Btus purchased or generation. - b. Delivered prices of each fuel YTD 2006. - c. Average...

AI summary The document requests specific fuel-related information for utilities listed in Exhibit AR-1, including fuel mix in 2005, delivered fuel prices for 2006, and average coal quality for 2006.

Response:
Response: - a. The attached pages show the primary sources of energy for each Canadian utility in petajoules. The source of this information was Canada's Energy Future published by the NEB. Similar data for U.S. utilities was unavailable....

AI summary The response provides information on the primary energy sources for Canadian utilities, referencing data from the NEB's 'Energy Future' and FERC Form 1 for U.S. utilities. Fuel prices and purchased power costs for U.S. utilities are included, but specific fuel prices are not known by Dr. Rosenberg. Some information is unavailable.

N-52N-52.pdf 1 passage
Nova Scotia Utility and Review Board
s of the Electricity Marketplace Governance Committee recommendations to promote renewable energy generation - 5) A reevaluation of Nova Scotia Power's current procurement policy for renewable energy - 6) The mandate of the Board to consid...

AI summary The text discusses the need to reevaluate Nova Scotia Power's renewable energy procurement policy and the Board's consideration of social and environmental costs and benefits. It references a comprehensive 400-page Energy Accounts report by GPI Atlantic, which provides an in-depth analysis of energy in Nova Scotia and includes recommendations for the energy sector.

57968Amended Board Order (and attached Schedules A to C) 1 passage
3.6.5 Metering
3.6.5 Metering - a) Net energy metering shall ordinarily be accomplished using a single meter capable of registering the flow of electricity in two directions as approved by Measurement Canada. If the eligible customer-generator's existing...

AI summary The section outlines requirements for net energy metering, specifying that a single bi-directional meter approved by Measurement Canada should be used. If the existing meter is not suitable, the customer-generator must bear the cost of incremental metering. In cases where a single meter is not feasible, NSPI may require separate meters, also at the customer's expense.

57974NSPI Compliance Filing 2007 Rate Application - REDACTED (Large File - 36 MB) 2 passages
FOR THE YEAR ENDING DECEMBER 31, 2007
FOR THE YEAR ENDING DECEMBER 31, 2007 (1) TOTAL (2) (3) SMALL (4) (5) GENERAL (6) SMALL (7) MEDIUM (8) LARGE (9) EXTRA LI (10) (11) (12) ALLOCATION COMPANY DOMESTIC GENERAL GENERAL LARGE INDUSTRIAL INDUSTRIAL INDUSTRIAL INTERR 2 MUNICIPAL...

AI summary The document presents a table with various metrics related to demand, responsibility percentages, and energy generation and purchase figures for different categories, including small, general, and large industrial sectors, as well as municipal and unmetered entities, for the year ending December 31, 2007.

SALES, GENERATION AND DEMAND ANALYSIS FOR THE YEAR ENDING DECEMBER 31, 2007
SALES, GENERATION AND DEMAND ANALYSIS FOR THE YEAR ENDING DECEMBER 31, 2007 (1) MWH (2) ENERGY LINE (3) ENERGY (4) CLASS NON- COINCIDENT (5) SYSTEM COINCIDENT (6) SYSTEM COINCIDENT (7) DEMAND LINE (8) SYSTEM COIN. PEAK (9) SYSTEM COINCIDEN...

AI summary The document presents a detailed analysis of sales, generation, and demand for the year ending December 31, 2007, including energy losses, requirement, and demand factors across various customer classes and categories. It provides a comprehensive overview of energy usage and distribution metrics.

58003Participant responses to Preliminary Issues List for P-886 1 passage
Section 44
- 6. the extra volatility experienced in fuel prices from the international market in recent years; - 7. the introduction of substantial quantities of wind power, and the prospect of further large increases in wind power as the Province ro...

AI summary The text discusses factors contributing to increased volatility in fuel prices, the impact of wind power integration, and the move toward a partially competitive market. It also highlights concerns about the current COS Study's methodology, which disproportionately affects high load factor customers, as demonstrated by Dr. Rosenberg's testimony.

58140Final Submission - Ecology Action Centre 2 passages
Is NSPI Undertaking Reasonable and Prudent Expenses Given Opportunities for Demand Side Management?
. - 14. Further, the DSM Plan submitted by Nova Scotia Power Inc. on September 81 2006 does not provide a full accounting of avoided costs or the maximum achievable economic potential in Nova Scotia. - 15. A letter written by EAC consultan...

AI summary The DSM Plan submitted by Nova Scotia Power Inc. is criticized for not fully accounting for avoided costs or the maximum achievable economic potential in Nova Scotia. The EAC highlights that the report's methodology may have been unduly influenced by other jurisdictions and lacks necessary documentation to assess energy efficiency potential.

Is NSPI Undertaking Reasonable and Prudent Expenses Given Opportunities for Renewable Energy Generation?
Is NSPI Undertaking Reasonable and Prudent Expenses Given Opportunities for Renewable Energy Generation? - 22. NSPI's strategy of incurring fuel expenses must also be viewed in light of their capital investment decisions. Since 1979 the ov...

AI summary The document argues that NSPI has been complicit in prioritizing capital expenditures that involve fuel costs over investments in renewable energy, which could reduce vulnerability to fuel price volatility. It calls for a comprehensive study on Nova Scotia's electricity network's capacity to support distributed renewable energy generators, citing the Public Utilities Act.

58246Comments on Preliminary Issues list - Municipal Electric Utilities of NS Co-operative (MEUNSC) [via Berwick Electric Commission] 1 passage
Section 2
vernment and the Department of Energy to· show leadership in fonnulating what i$ in fact Provincial energy and emission$ policy. We will aU pay for the outcomes. and we will an live with the outcomes. To the extent that there is a public h...

AI summary The text discusses the need for provincial energy and emissions policy, supports certain environmental measures outside the IRP process, and endorses recommendations for renewable energy and co-generation. It emphasizes the importance of public health benefits and the need to complete the Integrated Resource Plan (IRP) before approving new generation additions.

Disclaimer: These summaries were generated by AI from the filings they describe. We take care to make them accurate, but errors are possible - and they aren't advice. Only the filings themselves are the record: if you're relying on something here, confirm it against the source documents or the Nova Scotia Energy Board's own record. Full disclaimer →