Matter: CI# 38900 - P-128.10 - NSPI WO - Opsym-Incumbent Generation Dispatch Modeling $959,107
8 passages 2 documents

Infrastructure Planning across all matters →

N-1Non-Confidential Work Order 7/30/2010 7 passages
The variance between ACE 2010 and the revised submission is due to the estimate being updated since ACE 2010. p. p. 1
The variance between ACE 2010 and the revised submission is due to the estimate being updated since ACE 2010. Cost Centre 389 389-Energy Fuels & Risk Mgmt. Budget Version 2010 06/06 Forecast Capital Item Accounts Aect Actv Account Activity...

AI summary The text discusses a variance between the ACE 2010 estimate and a revised submission, attributing the difference to an updated estimate. A detailed table outlines various cost centres, activities, forecast amounts, and variances under Budget Version 2010 06/06 Forecast.

3.1.3. Physical Parameters & Condition p. pp. 12-16
3.1.3. Physical Parameters & Condition The Opsym environment consists of two high performance HP WX 6200 desktop computers, one each for the Real-Time and Day-Ahead trading desks. The Opsym environment hardware currently meets the business...

AI summary The Opsym environment uses two HP WX 6200 desktops for Real-Time and Day-Ahead trading, supported by NSP IT. The application is locally installed with a flat-file database, lacking auditing and reporting features. Ventyx no longer develops Opsym, and it will be replaced by EnerPrise, a client-server .NET system. Current limitations include missing transmission constraint modeling, addressed via workarounds.

3.3.Growth p. p. 16
3.3.Growth Commercial Operations has Opsym installed on two machines (Real Time and Day Ahead trading desks) and is currently used by eight individuals. It is likely that this will increase as the group endeavors to incorporate Opsym in a...

AI summary Commercial Operations currently uses Opsym on two machines with eight users. The group plans to expand its use to a post-dispatch evaluation role, likely increasing adoption.

3.5.Renewal / Replacement Plan p. p. 19
3.5.Renewal / Replacement Plan The renewal and/or replacement of the Opsym application will be based on its ability to meet the business needs of NSPI's Commercial Operations group. A renewal or replacement initiative may be triggered by r...

AI summary The renewal or replacement of the Opsym application by NSPI depends on its ability to meet the Commercial Operations group's needs, with initiatives triggered by reliability issues, changes in asset use, or performance degradation.

4.5.Change in the business environment p. p. 23
4.5.Change in the business environment In the future, Nova Scotia Power expects to have to incorporate a significant volume of private sector generation into the dispatch model. As a result, there is an expected need for a flexible applica...

AI summary Nova Scotia Power anticipates integrating private sector generation into its dispatch model, requiring a flexible application. It also plans to implement a Fuel Adjustment Mechanism (FAM) and conduct longer-term studies, as the current NSP version of Opsym is limited to one-month runs.

6.4. Develop an operational maintenance plan for Opsym p. p. 23
6.4. Develop an operational maintenance plan for Opsym A series of regular scheduled system health checks should be developed to mitigate the risk of system failure. $0 - $5,000 $50,000 - $100,000 $5,000 - $10,000 $100,000 - $250,000 $10,0...

AI summary The document recommends developing regular scheduled system health checks for Opsym to mitigate system failure risks. It includes placeholder cost ranges, though the specific financial context or justification for these figures is not elaborated.

p. p. 27
QUESTION YES IP NO Does management regularly review the list of persons with physical access to sensitive facilities? X 8.2. APPENDIX B - CONTINUITY RISK MITIGATION CHECKLIST

AI summary The document includes a table and an appendix titled 'Continuity Risk Mitigation Checklist' under section 8.2. The table asks whether management regularly reviews the list of persons with physical access to sensitive facilities, with a 'YES' marked.

05622Board Decision Letter 1 passage
CI # 38900 Opsym - Incumbent Generation Dispatch Modeling Tool $959,107 p. p. 0
CI # 38900 Opsym - Incumbent Generation Dispatch Modeling Tool $959,107 The current cost estimate for this project of $959,107 represents a slight reduction from the amount of $988,123, which was included in the 2010 ACE Plan. As a part of...

AI summary The Board approved a $959,107 capital expenditure for NSPI to replace the outdated Opsym software with Ventyx's Energy Portfolio Management tool, citing necessity and cost justification. The project aims to enhance dispatch modeling for combined cycle gas turbines, wind resources, and transmission, improving NSPI's operational efficiency. The approval follows a 2010 ACE Plan review and subsequent information requests.

Disclaimer: These summaries were generated by AI from the filings they describe. We take care to make them accurate, but errors are possible - and they aren't advice. Only the filings themselves are the record: if you're relying on something here, confirm it against the source documents or the Nova Scotia Energy Board's own record. Full disclaimer →