Home›Load Management›M06319›Evidence
Topic/Matter Intersection

Topic:"Load Management" in M06319

Matter: P-886 Nova Scotia Power Inc. (NSPI) Rate Application 2007
78 passages 17 documents

Load Management across all matters →

N-1-aNotice of Application and Direct Evidence - NSPI - REDACTED (Large File - 59 MB) 4 passages
Highlights of the 2006 forecast include:
Highlights of the 2006 forecast include: 18 19 20 17 • In-province electric energy sales, which have grown at an average annual rate of 1.9 percent over the past five years, are forecast to grow by 1.9 percent annually on average from actu...

AI summary The 2006 forecast highlights in-province electric energy sales growth, peak demand projections, and factors influencing load growth, including economic trends, customer additions, and energy efficiency. It also explains the use of billed sales for forecasting and the impact of weather and alternative fuels on load variations.

3 7 .4.2 Commercial Sector
3 7 .4.2 Commercial Sector 4 5 The commercial sector includes restaurants, theatres, retail stores, banks, office buildings, 6 malls, schools and street and traffic lights, etc. 2006 commercial sales are expected to 7 make up 26 percent of...

AI summary The commercial sector in Nova Scotia includes a variety of businesses and institutions, and its energy consumption is forecast using an econometric model that considers GDP, disposable income, and prior load levels. Large firms and institutions are surveyed individually and reconciled to the overall sector forecast.

3 7.4.3 Industrial Sector
3 7.4.3 Industrial Sector 4 5 The industrial sector includes customers who manufacture finished goods, or who process 6 material to produce a product of higher value. This includes fish plants, pulp and paper 7 mills, mines, tire manufactu...

AI summary The industrial sector in Nova Scotia includes manufacturers and processors that account for 34% of in-province energy use. Load forecasting uses econometric modeling and customer surveys, especially for large industrial customers influenced by external factors like foreign exchange rates and international demand. Forecast accuracy is shown in Figure 7.10, with industrial sales being relatively insensitive to weather.

Figure 7.10
Figure 7.10 Ind Industrial Sector Forecast Accuracy Year Forecast GWh Actual GWh % Variance 1998 3,297 3,442 (4.4) 1999 3,497 3,872 (10.7) 2000 3,806 3,930 (3.3) 2001 4,020 3,873 3.7 2002 4,008 3,799 5.2 2003 3,899 4,046 (3.8) 2004 4,120 4...

AI summary Figure 7.10 presents the forecast versus actual GWh for the industrial sector from 1998 to 2005, showing varying levels of accuracy. Figure 7.11 highlights load growth during this period, noting that industrial load growth has averaged 1.4 percent annually over the last five years, influenced by expansions at large customer sites and business closures.

N-1-aAppendix G - Cost of Service Study - REDACTED (Large File - 14 MB) 1 passage
NOVA SCOTIA POWER INC. DETAIL OF MONTHLY CLASS COINCIDENT KW DEMAND FOR THE YEAR ENDING DECEMBER 31 , 2007
NOVA SCOTIA POWER INC. DETAIL OF MONTHLY CLASS COINCIDENT KW DEMAND FOR THE YEAR ENDING DECEMBER 31 , 2007 MONTH (1 ) TOTAL (2) COMPANY DOMESTIC (3) SMALL GENERAL (4) GENERAL (5) GENERAL LARGE (6) SMALL INDUST. (7) MEDIUM INDUST. (8) LARGE...

AI summary The document provides a detailed breakdown of monthly coincident kilowatt (kW) demand for various customer classes for Nova Scotia Power Inc. for the year ending December 31, 2007. It includes specific data for categories such as Company Domestic, Small General, General Large, and various industrial classifications (Small, Medium, Large), as well as municipal unmetered systems and other specific service areas like Mersey and GRLF.

N-1-aAppendix H - Proposed Tariffs (Large File - 21 MB) 13 passages
AVAILABILITY:
AVAILABILITY: This rider will be available to a minimum regular billing demand of 2 000 k V .A at 90% Power Factor, under the following terms and conditions: - (1) The customer has provided written notice of his desire to take service unde...

AI summary The text outlines the terms and conditions for a specific service rider requiring a minimum regular billing demand of 2,000 kVA at a 90% Power Factor. Key requirements include written notice from the customer to identify firm and interruptible load portions, a mandate for customers to reduce interruptible load within ten minutes of a request, and specific protocols for service restoration. It also specifies penalty charges for non-compliance and notice periods for converting between firm and interruptible service rates.

AVAILABILITY:
AVAILABILITY: This rider will be available to a minimum regular billing demand of 2 000 k V .A at 90% Power Factor, under the following terms and conditions: - (1) The customer has provided written notice of his desire to take service unde...

AI summary The text outlines the availability and operational requirements for a specific rate rider for customers with a minimum regular billing demand of 2,000 kVA at a 90% Power Factor. It establishes terms for customers seeking interruptible load, requiring written notice, a 10-minute response time for load reduction requests, and company approval for service restoration. It also specifies penalty charges for non-compliance and notice periods for converting between firm and interruptible service rates.

Preamble
- a) Determine the expected system load factor for the year for which the ELIIR is being calculated. - b) Apply this system load factor to the Large Industrial Interruptible Rider to determine a cost per kWh. - c) Determine the ELIIR in ce...

AI summary The text outlines a multi-step methodology for calculating and adjusting the ELIIR (Electricity Load Interruptible Rider) and its associated Load Factor Adjustments (LFA). The process involves determining the expected system load factor, applying it to the Large Industrial Interruptible Rider to find a cost per kWh, and using polynomial curve fitting to align the ELIIR with the LFA. This procedure is intended for annual application to adjust the LFA values within a specific table.

Tariff Demand:
Tariff Demand: The customer will notify the Company of the value of the Tariff Demand in kW for the forthcoming year on or before November 1. The TD represents the total amount of load subscribed to this rate. The Company will permit devia...

AI summary The text outlines the procedures for establishing and adjusting the Tariff Demand (TD), which represents the total subscribed load for a customer. Customers must notify the Company of their TD value in kW by November 1 of the preceding year. The Company allows for deviations based on load management initiatives of at least 2 MW or permanent capacity alterations. Additionally, customers may request an annual market-based adjustment of up to 10% of the existing TD by February 28 of the applicable rate year.

EXTRA LARGE INDUSTRIAL INTERRUPTIBLE TARIFF
EXTRA LARGE INDUSTRIAL INTERRUPTIBLE TARIFF With the exception of Planned Shutdown Periods, the annual market adjustment, load management initiatives and permanent alterations to production capacity, no changes will be permitted except for...

AI summary The document outlines the restrictions and permissions regarding the Extra Large Industrial Interruptible Tariff. It specifies that no changes to the tariff are permitted except for force majeure reasons or with the express permission of Nova Scotia Power Inc., excluding specific items like Planned Shutdown Periods, annual market adjustments, and load management initiatives. Additionally, the Company allows forward-looking monthly adjustments to the Tariff Demand (TD) for the first three months following initial subscription or after a previously described deviation.

Economic Interruptions:
Economic Interruptions: An Economic Interruption is defined as a request by the Company for the customer to reduce load in order for the Company to avoid unnecessarily high costs of electricity supply. For the purposes of Economic Interrup...

AI summary The document defines 'Economic Interruptions' as a mechanism where the Company requests customers to reduce their electrical load to avoid high supply costs. These high costs are specifically identified as those incurred when the Company is forced to dispatch peaking power combustion turbines or purchase import energy to replace the output of peaking power combustion turbines.

3. Interruption Notification Procedure:
3. Interruption Notification Procedure: The customer will make available suitable contact telephone numbers of a person or persons who are able to reduce the required load within the time requested by NSPI during the Interruption call. The...

AI summary This section outlines the procedures for interruption notifications between Nova Scotia Power Inc. (NSPI) and its customers. Customers are required to provide contact information for personnel capable of reducing load within requested timeframes. NSPI maintains sole discretion over notification timing and can request up to the full subscribed load. Customers must nominate minimum interruptible load blocks based on equipment practicality. For Economic Interruptions, NSPI will provide a faxed confirmation detailing the interruption's duration, capacity in MW, and the applicable Buy-Through-Rate.

5. Advance Notice for Economic Interruptions:
5. Advance Notice for Economic Interruptions: In the event of an Economic Interruption, the Company may request a minimum of 20 MW or the greater value stipulated in the prior agreement, (see section 7 below), to be interrupted with a mini...

AI summary The document outlines the procedures for Advance Notice for Economic Interruptions. In such events, Nova Scotia Power Inc. (the Company) may request to interrupt a minimum of 20 MW (or a value specified in a prior agreement) with at least 30 minutes' notice. For any remaining subscribed load, a minimum of 120 minutes' notice is required. The Company commits to providing forewarning on a best-efforts basis if an interruption becomes necessary.

7. Frequency and Duration of Economic Interruptions:
7. Frequency and Duration of Economic Interruptions: The annual maximum energy that may be called for interruption or buy through under Economic Interruption will be 0.31 GWh per MW of Tariff Demand subscribed under this rate. The frequenc...

AI summary The text outlines the parameters for Economic Interruptions, establishing an annual maximum energy limit of 0.31 GWh per MW of subscribed Tariff Demand. It specifies that the frequency and duration of these interruptions must be mutually agreed upon via a separate agreement, with a minimum duration of three hours per event. If the Company exhausts the customer's apportioned energy, it must invite the customer to participate in additional mutually beneficial interruption opportunities.

9. Buy-Through Option for Economic Interruptions:
9. Buy-Through Option for Economic Interruptions: If the customer is unable to comply with any Economic Interruption request, the energy that is not interrupted as requested by the Company shall be billed at a Buy-Through Rate. The buy thr...

AI summary The text outlines the 'Buy-Through Option for Economic Interruptions' for customers under a specific rate. If a customer cannot comply with an energy interruption request made by Nova Scotia Power Inc. (NSPI), the non-interrupted energy is billed at a 'Buy-Through Rate.' This rate is calculated monthly based on the estimated fuel cost of peaking combustion turbines, a heat rate of 15,000 BTU/kWh, and a $5/MWh fixed component. NSPI commits to balancing interruption hours among customers under this rate.

10. Verification of Interruption:
10. Verification of Interruption: For each Interruption event, the Company shall, using meter data collected at designated metering points, confirm the response time, duration and amount of load Interrupted by the customer. For the purpose...

AI summary The text outlines the requirements for the Company to verify power interruptions. It specifies that the Company must use meter data from designated points to confirm the response time, duration, and amount of load interrupted. The customer load at the time of the call is determined by averaging the metered loads from the two fifteen-minute billing intervals preceding the call. To qualify for the rate, at least 95% of the requested load must be interrupted for the specified duration.

11 . Verification of Ability to Interrupt:
11 . Verification of Ability to Interrupt: Unless, within the most recent 12-month period, the customer has demonstrated the ability to interrupt load, either by a test or for economic or system reasons, the Company may at its sole discret...

AI summary The text outlines the procedures for verifying a customer's ability to interrupt load. If a customer has not demonstrated this ability within the last 12 months through testing or for economic/system reasons, the Company reserves the right to conduct periodic tests. These tests involve an interruption call and a maximum one-hour service interruption. Failure to comply with the interruption request results in penalties, and the Company may conduct additional tests if the verification process is not successfully completed.

Incremental Shifted Load (ISL)
Incremental Shifted Load (ISL) This is the hourly energy considered to have been shifted from a higher-cost period. It is calculated as the difference between the actual load and the CBL whenever the actual load exceeds the CBL.

AI summary The text defines the Incremental Shifted Load (ISL) metric, which represents hourly energy shifted from high-cost periods. It is calculated by determining the difference between the actual load and the Customer Billing Line (CBL) specifically during instances where the actual load exceeds the CBL.

N-1-aAppendix F - Load Forecast Report (Large File - 16 MB) 4 passages
Annual Net System Requirement
Annual Net System Requirement In addition to annual energy requirements, NSPI also forecasts the peak hourly demand for future years. The process uses forecast energy requirements and expected load shapes (hourly consumption profiles) for...

AI summary Nova Scotia Power Inc. (NSPI) forecasts the annual net system requirement by combining annual energy requirements with peak hourly demand projections for future years. This process involves applying expected load shapes—derived from historical consumption profiles—to various customer classes. These load shapes are further adjusted based on anticipated changes, such as the installation of major equipment by customers, to determine the growth of the annual net system peak.

7 Generation Replacement and Load Following
7 Generation Replacement and Load Following 8 - 9 This class is available to customers who have their own generation capacity of no less than 2,000 - 10 kW. As of December 2005, this class comprised three customers and represented about 0....

AI summary The text describes a specific customer class for Nova Scotia Power Inc. (NSPI) that includes customers with their own generation capacity of at least 2,000 kW. As of December 2005, this class represented approximately 0.1 percent of total NSPI sales and comprised three customers. The load is characterized as interruptible and is forecasted to remain stable at approximately 12 GWh annually.

1 Non Firm Coincident Peak
1 Non Firm Coincident Peak 2 3 NSPI offers interruptible, or "non-firm" service to industrial customers who meet certain criteria 4 and contract to have their electricity supply interrupted on short notice in order to meet any 5 necessary...

AI summary Nova Scotia Power Inc. (NSPI) provides non-firm, interruptible electricity services to industrial customers to facilitate emergency peak reductions. These services are offered under specific rate classes, including the Generation Replacement and Load Following rate, the Extra Large Industrial Interruptible rate, and the Interruptible rider. As of January 2005, 30 customers were enrolled, totaling a coincident non-firm peak of 392 MW. Forecasts assume moderate growth based on current customer retention and historical trends.

High and Low Forecast Scenarios
High and Low Forecast Scenarios Low Forecast Scenario Assumptions 1 1, 700 GWh lyr from 2007 onward) Major Paper Mill Closure(- 2 Economic Growth Diminishes (Base case growth rate decreases by 50%) 3 45% reduction in home heating oil price...

AI summary The document outlines two extreme forecast scenarios—High and Low—to test the sensitivity of the 2006 Load Forecast. The Low Forecast assumes diminished economic growth, major paper mill closures, lower heating oil prices, and reduced residential customer additions. Conversely, the High Forecast assumes improved economic growth, new industrial load additions, significant heating oil price increases, and higher residential customer growth. The tables provide year-over-year projections for Net System Requirement (NSR) and Peak demand in GWh and MW from 2007 to 2015 under these varying assumptions.

N-2-aRIRs 40 to 69 - NSUARB to NSPI - REDACTED (Large File - 34 MB) 1 passage
January 2005 Non-firm Classes Load
January 2005 Non-firm Classes Load Lg. Industrial Interruptible Rider 92 GRLF 0 ELIIR 290 Losses 10 Total Non-firm : 392 Note: The figures presented have been rounded.

AI summary The document provides a table detailing the load for various non-firm classes as of January 2005. It specifies load figures for the Large Industrial Interruptible Rider (92), ELIIR (290), and losses (10), resulting in a total non-firm load of 392. The data includes a Grid Reliability Loss Factor (GRLF) of 0 and notes that all figures presented have been rounded.

N-2-bRIRs 77 to 84 - NSUARB to NSPI - REDACTED (Large File - 35 MB) 1 passage
RESPONSE TO INFORMATION REQUEST
RESPONSE TO INFORMATION REQUEST TO: NSPI FROM: UARB Question IR-83: Please provide the load forecast information used as input to the Strategist run, including monthly peak demand, monthly energy requirements and the typical week used for...

AI summary The Nova Scotia Utility and Rate Board (UARB) provided a response to an information request (IR-83) from Nova Scotia Power Inc. (NSPI). The response includes the load forecast data used for the Strategist run, specifically detailing 2007 monthly energy requirements and peak demand. The UARB provided this data in multiple formats, including a tabular 168-hour typical week and supporting graphical representations.

N-2-dRIRs 1 to 46 - CME to NSPI - REDACTED (Large File - 18 MB) 1 passage
RESPONSE TO INFORMATION REQUEST
RESPONSE TO INFORMATION REQUEST TO: NSPI FROM: CME Question IR-29: Reference Page 140, Lines 29-31 Adjusting for the re-entry of a large industrial customer, provide a detailed explanation including assumptions as to why load increases are...

AI summary Campbell Scott Management (CME) responds to an Information Request (IR-29) regarding Nova Scotia Power Inc.'s (NSPI) load growth forecasts. CME disputes the premise of the question, arguing that the projected load increases are consistent with historical patterns. To support this, CME provides a table estimating load growth rates that would have occurred if a specific large industrial customer had been at full load since 2006, demonstrating that the 2007 forecasts remain within historical ranges.

N-2-gRIRs 1 to 25 - Stutz to NSPI - REDACTED (Large File - 18 MB) 1 passage
RESPONSE TO INFORMATION REQUEST
RESPONSE TO INFORMATION REQUEST TO: NSPI FROM: Stutz Question IR-17: Reference DE, page 150, lines 10 to 13 Does NSPI have any evidence that the "large Industrial Customer" that shut down in 2006 will not shut down again in 2007. If so ple...

AI summary Nova Scotia Power Inc. (NSPI) responded to an Information Request regarding the operational status of a large industrial customer that closed in 2006. NSPI stated that the customer informed them of plans to operate at full production for the entire year of 2007. NSPI indicated they have no reason to believe the customer will cease operations again in 2007.

N-7-aRIRs 27 to 39 - AEC to NSPI - REDACTED 2 passages
What do you mean by "off-peak" times?
What do you mean by "off-peak" times? There are different times throughout the day, and different seasons throughout the year when demand for electricity is higher. Nova Scotia Power must be able to produce and distribute enough electricit...

AI summary The text explains the concept of 'off-peak' times in the context of electricity demand, noting that while peak times require Nova Scotia Power to ensure sufficient generation and distribution capacity, off-peak times have excess capacity. To manage load and encourage customers to shift their electricity usage to these periods of lower demand, Nova Scotia Power offers a Time-of-Day (TOD) rate.

How can I save money with these rates?
How can I save money with these rates? Your electric space heating and hot-water systems account for the majority of the electricity you use, so a significant way to save money is by using electricity at times when the lowest rates are in...

AI summary The text provides guidance to consumers on reducing electricity costs by shifting energy usage to off-peak periods when rates are lowest. It highlights that space heating and hot-water systems are primary energy consumers and suggests using thermal storage and automated controls for these systems. Additionally, it recommends using major appliances like washers, dryers, and dishwashers during off-peak hours to achieve significant savings on total electricity bills.

N-40RIRs Attachment SEB-NSPI - 2a, pt. 1 (Large File - 22 MB) 9 passages
Line No. Rate Grou~s I<:VV Share of Retail Peak (A) Percent Share of Retail Peak (B) Line No.
Line No. Rate Grou~s I<:VV Share of Retail Peak (A) Percent Share of Retail Peak (B) Line No. RateRS 1,582,005 36.728% 2 Rates CS 224,244 5.206% 2 3 Rate LLF 628,152 14.583% 3 4 Rate HLF 1,808,566 41 .986% 4 5 Purdue-Supplemental 10,481 0....

AI summary The document presents a table detailing the distribution of the retail peak load across various rate groups for a utility proceeding. It identifies the specific kilowatt (KW) share and percentage share for different categories, including Residential Service (RS), Commercial Service (CS), Large Load Fuel (LLF), High Load Fuel (HLF), and several other specific industrial and supplemental rate groups, totaling 4,307,464 KW for the retail peak.

Line No. Rate Groues kW Share of Summer S~stem Peak (A) Percent Share Of Summer S:tstem Peak (B) Line No.
Line No. Rate Groues kW Share of Summer S~stem Peak (A) Percent Share Of Summer S:tstem Peak (B) Line No. RateRS 1,912,350 34.396% 1 2 3 4 Rates CS and FOC Rate LLF Rate HLF 287,915 781,159 2,002,337 5.179% 14.051% 36.017% 2 3 4 5 6 7 8 9...

AI summary The document provides a breakdown of the company's total load, categorized by rate groups and their respective shares of the summer system peak. It lists various rate groups including Residential (RateRS), Commercial (Rates CS), Fuel Oil Customers (FOC), and several industrial accounts. The data shows that 'TOTAL RETAIL' accounts for 90.678% of the peak, while 'WHOLESALE' accounts for 9.322%, totaling 100% of the company's load.

RJDER IS (NC) INTERRUPTIBLE POWER SERVICE
RJDER IS (NC) INTERRUPTIBLE POWER SERVICE Available at the Company's option to non-residential customers receiving concurrent service from the Company on Schedules G, GA, I, GT, IT, or OPT who are not served under Rider SCG. Under this Rid...

AI summary The document describes the RJDER IS (NC) Interruptible Power Service, a provision available to non-residential customers on specific schedules (G, GA, I, GT, IT, or OPT) who are not under Rider SCG. Under this rider, customers agree to reduce and maintain their load at specified levels upon the Company's request. The Company reserves the right to request service interruptions at any time during capacity problems, subject to the terms of individual contracts.

I. General Provisions:
I. General Provisions: Contracts for interruptible power service will be accepted by the Company on the basis of successive contracts, and each contract shall specifY an interruptible, integrated demand of not more than 50,000 KW to be sub...

AI summary This section outlines the general provisions for interruptible power service contracts. The Company accepts successive contracts with an integrated demand limit of 50,000 KW per contract, capped at a total of 1,100,000 KW across all nonresidential schedules. Customers may opt to apply these provisions to specific submetered portions of their load. The Company reserves the right to conduct annual tests of the rider provisions with advance notice and may terminate continued service if a customer fails to perform satisfactorily during requested interruptions.

2. Definitions:
2. Definitions: Contract Demand: The Contract Demand is the maximum kilowatt demand which the Company shall be required to supply to the Customer. Interruptible Contract Demand: The Interruptible Contract Demand of not more than 50,000 KW...

AI summary This section provides formal definitions for terms used in the service agreement, specifically regarding demand management and interruptible power service. It defines Contract Demand, Interruptible Contract Demand, and Firm Contract Demand, establishing the parameters for electricity supply. Additionally, it defines Interruption Periods, Penalty Demand for exceeding firm limits during interruptions, and the specific 'Exposure Periods' for summer and winter months used to compute monthly credits for customers under Schedule OPT.

3. Control Notices and Limitations:
3. Control Notices and Limitations: The Customer shall be notified of all initiations of Interruption Periods at least thirty (30) minutes prior to such times, and the Customer shall fully comply with the Company's requests to reduce and m...

AI summary This section outlines the operational requirements and limitations for the RJDERIS(NC) Interruptible Power Service. It mandates that the Company provide customers with at least 30 minutes' notice before initiating an Interruption Period. Customers are required to maintain their load within the Firm Contract Demand during these periods. The Company is limited to 150 hours of interruptions annually, with a daily maximum of 10 hours unless a mutual agreement for extension is reached with the customer.

RIDER IS (SC) INTERRUPTIBLE POWER SERVICE
RIDER IS (SC) INTERRUPTIBLE POWER SERVICE Available at the Company's option to non-residential customers receiving concurrent service from the Company on Schedules G, GA. I, GT, IT, OPT, or PG. Under this Rider the Customer agrees, at the...

AI summary The text describes the 'Rider IS (SC) Interruptible Power Service,' which is an optional service available to non-residential customers on various rate schedules (G, GA, I, GT, IT, OPT, or PG). Under this rider, customers agree to reduce and maintain their electrical load at specified levels upon the Company's request. The Company reserves the right to interrupt service at any time when capacity problems occur, subject to the specific provisions of the individual contract.

2. Definitions:
2. Definitions: Contract Demand: The Contract Demand is the maximum kilowatt demand which the Company shall be required to supply to the Customer. Interruptible Contract Demand: The Interruptible Contract Demand of not more than 50,000 KW...

AI summary This section provides formal definitions for terms related to an Interruptible Power Service agreement. It defines the various components of Contract Demand, distinguishing between Firm Contract Demand (guaranteed availability) and Interruptible Contract Demand (subject to outages). It also establishes the parameters for Interruption Periods, Penalty Demand for exceeding firm limits during those periods, and the specific weekday peak windows designated as Exposure Periods for calculating monthly credits.

3. Control Notices and Limitations:
3. Control Notices and Limitations: The Customer shall be notified of all initiations oflnterruption Periods at least thirty (30) minutes prior to such times, and the Customer shall fully comply with the Company's requests to reduce and ma...

AI summary This section outlines the operational requirements and limitations for Interruptible Power Service (RJDER IS). It specifies that the Company must provide the Customer with at least 30 minutes' notice before the initiation and termination of Interruption Periods. Customers are required to maintain their load below the Firm Contract Demand during these periods. The Company's ability to invoke these periods is capped at 150 hours annually and 10 hours per calendar day, unless otherwise mutually agreed upon.

N-40RIRs Attachment SEB-NSPI - 2a, pt. 4 (Large File - 19 MB) 9 passages
3. CONTRACTDEMAND
3. CONTRACTDEMAND The Contract Demand shall be the maximum kW of demand Customer requires Company to supply for the operation of Customer's facility. When this Rider is used in conjunction with the applicable standby or generation service...

AI summary This section defines the 'Contract Demand' as the maximum kilowatt (kW) capacity a customer requires for facility operations. It specifies that when used with standby or generation service riders, standby service cannot replace curtailable load. Additionally, it establishes that Contract Demand is subject to curtailment down to the Firm Demand level.

4. CURTAILABLE PERJOD
4. CURTAILABLE PERJOD The Curtailable Period shall be an eight-hour period unless Company specifies a shorter period at the time the Customer is notified. Customer shall be given a minimum of 30-minutes notice before requested curtailment...

AI summary The text defines the parameters for the 'Curtailable Period,' which is generally an eight-hour window during which the Company may request a Customer to reduce their energy requirements. Customers must receive at least 30 minutes of notice. The Company distinguishes between Capacity Level 1 (where firm energy purchases are anticipated) and Capacity Level 2 (where firm energy purchases are not anticipated) curtailments. The Company's determination of the level is binding, and it is not liable if notice is not received despite using reasonable diligence. Annual capacity curtailment is capped at 400 hours.

AVAILABILITY
AVAILABILITY This Rider is available on a voluntary basis in conjunction with Company's Large General Service and Large General Service (Time-of-Use) Schedules for electric service used by a nonresidential customer provided Customer contra...

AI summary The text describes the availability and conditions of a specific Rider for nonresidential customers. The Rider is voluntary and must be used in conjunction with Large General Service and Large General Service (Time-of-Use) Schedules for contracts of at least 1,000 kW that are subject to curtailment. The total system curtailable load for this Rider is capped at 150,000 kW. It explicitly excludes short-term or temporary service and modifies existing schedules only as specified.

4. CURTAILABLE PERIOD
4. CURTAILABLE PERIOD The Curtailable Period shall be an eight-hour period unless Company specifies a shorter period at the time Customer is notified. Customer shall be given a minimum of 30-minutes notice before RIDER-58E Sheet 1 of3 requ...

AI summary The text defines the 'Curtailable Period' for customers under RIDER-58E, establishing an eight-hour maximum duration per 24-hour period, with a total annual cap of 400 hours. Customers must receive at least 30 minutes' notice before requested curtailments. The Company distinguishes between Capacity Level 1 and Level 2 curtailments based on the availability of reserves and firm energy purchases. The Company's determination of the curtailment level is binding, and it is not liable for missed notifications if reasonable diligence is exercised.

SPECIAL CONDITIONS:
SPECIAL CONDITIONS: Any farm's monthly irrigation and pumping load qualifying hereunder for each billing period shall not exceed the amount of the energy determined by the following formula: 7,161.6 kWh x days in billing period, provided ,...

AI summary The text establishes specific special conditions and limitations for farm irrigation and pumping loads within a regulatory framework. It defines a maximum monthly energy allowance based on a formula of 7,161.6 kWh multiplied by the number of days in the billing period. Additionally, it stipulates that the calculated amount cannot exceed the farm's actual measured energy and imposes an absolute cap of 222,000 kWh on total qualifying irrigation loads for any billing period.

AVAILABILITY
AVAILABILITY This schedule is available to any customer receiving concurrent service from the Company on Rate Schedules 23 or 24. The rider is limited to those customers that can centrad for 1,000 KW of interruptive demand or greater durin...

AI summary This section outlines the availability and eligibility criteria for a specific interruptible service rider. It applies to customers on Rate Schedules 23 or 24 who can provide at least 1,000 KW of interruptive demand between June and September. The rider is subject to a total aggregate limit of 150,000 KW across all customers and is explicitly prohibited for resale service.

DEFINITIONS
DEFINITIONS Firm Demand Level: The Firm Demand Level (FDL) shall be the KW of demand specified in Interruptible Service Contract to which customer shall reduce his requirement at the time specified by the Company. Interruptible Demand: Int...

AI summary This section provides formal definitions for terms used in Interruptible Service Contracts. It defines 'Firm Demand Level' as the specific kilowatt (kW) demand a customer agrees to maintain. It further defines 'Interruptible Demand' as the difference between the actual demand measured during on-peak 15-minute intervals and the Firm Demand Level. Finally, it introduces the 'Exposure Period' as the timeframe during which the Company has the authority to curtail customer load exceeding the Firm Demand Level.

Preamble
In case of a system emergency, firm service will have priority over interruptible service even if maximum curtailable hours have been exhausted. Curtailment Period: The Curtailment Period is the period which the customer shall reduce KW de...

AI summary The text outlines the operational protocols for system emergencies and demand curtailment. It establishes that firm service takes priority over interruptible service during emergencies. It defines the Curtailment Period as the duration a customer must reduce demand to the Firm Demand Level (FDL) based on Company notification. Provisions are made for notification methods, including a minimum four-hour notice (reduced to ten minutes during emergencies), and defines 'Penalty Demand' as the integrated demand exceeding the FDL within a 15-minute window during a Curtailment Period.

CONDITIONS OF SERVICE
CONDITIONS OF SERVICE Customer may choose to have Total kW or some portion thereof designated as Curtailable kW. The amount of Total kW not designated as Firm kW shall constitute Customer's Curtailable kW. Customer's service must be equipp...

AI summary The text outlines the conditions of service for the Experimental Curtailable Service Rider, which allows customers to designate a portion of their Total kW as 'Curtailable kW.' Customers are responsible for installing the necessary equipment and metering to reduce load during curtailment events. The Company may request curtailment to maintain service integrity, avoid system peaks, or manage load. The Company provides notice requirements for both non-emergency (30 minutes) and emergency (10 minutes) curtailments via telephonic communication.

N-40RIRs Attachment SEB-NSPI - 2h 1 passage
With Non-Firm Capacity Interruptible Credit (eft. 1211182)
With Non-Firm Capacity Interruptible Credit (eft. 1211182) 50.000 Load Factor 90% Monthly kWh 32,850,000 MonthlykW 50,000 Load Factor 90% Monthly kWh 32,850,000 Monthly kW Total ECR Factors for 2006:

AI summary The document provides technical load data associated with a 'With Non-Firm Capacity Interruptible Credit' (eft. 1211182). It specifies a monthly load of 50,000 kW with a 90% load factor, resulting in a monthly consumption of 32,850,000 kWh. The text also serves as a transition point to presenting ECR (Electricity Cost Recovery) factors for the year 2006.

N-40RIRs Attachment SEB-NSPI - 2a, pt. 2 (Large File - 15 MB) 9 passages
Section Number_ 1 Revision Number 0
Section Number_ 1 Revision Number 0 Sheet Number 15 Effective with energy consumed on or Page 1 of 4 after SCHEDULE NO. 27 INTERRUPTIBLE POWER SERVICE RATE

AI summary This document segment introduces Schedule No. 27, which outlines the Interruptible Power Service Rate. The schedule defines the specific tariff structure and conditions under which customers can receive electricity under an interruptible power service agreement, where the utility may temporarily reduce or interrupt power supply during periods of high demand.

= 16,425,000
= 16,425,000 Section Number 1 Revision Number0_ Sheet Number 15 Effective with energy consumed on or Page 2 of 4 after (N)

AI summary The provided text is a header page from a regulatory document, specifically identifying a section number of 16,425,000 and indicating that the document is Revision 0_ and Sheet 15. It includes a notation for 'N', which is defined in the context as 'interruptible power service'. No substantive arguments, entities, or thematic discussions are present in this excerpt.

Section 58
Title: INTERRUPTIBLE SERVICE (Rider IR) PSC File Mark Only - 18.6. SPECIAL CONDITIONS OF SERVICE: - 18.6.1. This rider requires a service contract which specifies the amount of demand available for reduction. The contracted demand reductio...

AI summary This section outlines the special conditions of service for Rider IR (Interruptible Service). Key requirements include a mandatory service contract specifying a minimum demand reduction of 500 kW, with annual contracts signed by December 31. The Company reserves the right to ensure contracted loads are reducible during peak periods. Customers are responsible for load monitoring, and the Company provides a minimum of one hour's notice for reductions, limited to 400 hours per year. The service is initially limited to ten customers for an experimental one-year period.

41.1. AVAILABILITY
41.1. AVAILABILITY Available upon installation of the appropriate metering and communications equipment to any customer receiving service under the Small General Service, Large General Service, Large Power Service, Large General Service Ti...

AI summary The text outlines the availability and conditions for the Interruptible Power Service Rider. The service is available to customers on specific rate schedules (Small General, Large General, Large Power, and Time-of-Use variants) who agree to use interruptible power and energy from Entergy Arkansas, Inc. during On-Peak Hours. Requirements include the installation of metering and communications equipment, a minimum capacity of 100 kW, and the rider's expiration upon the introduction of retail competition for electric generation.

41.2.5. PEAK LOAD CONDITIONS
41.2.5. PEAK LOAD CONDITIONS Peak Load Conditions are defined as those conditions on any day that could result in the Entergy System establishing a monthly peak.

AI summary The text provides a formal definition of Peak Load Conditions within the context of the Entergy System. It specifies that these conditions are defined as any circumstances occurring on a given day that have the potential to result in the establishment of a monthly peak for the system.

41.3. NOTIFICATION PROVISIONS
41.3. NOTIFICATION PROVISIONS The Company will notify the Customer or designated representative of the Customer via a mutually acceptable method by 4:30 p.m. that on the following day the Company may call for interruption ("Day-Ahead Notic...

AI summary This section outlines the notification requirements for the Company when requesting power interruptions from a Customer. It establishes a 'Day-Ahead Notice' requirement, provided by 4:30 p.m. the day before a planned interruption, which must include an estimated start time. It specifies that if no interruption occurs following such a notice, hours will be imputed as if an interruption had occurred. Additionally, it provides for a 30-minute advance notice during peak load, capacity shortage, or emergency conditions.

DESCRIPTION:
DESCRIPTION: This tariff allows customers to participate in credits for demand reduction. Customers will receive credits in exchange for reducing electric demand during periods in which the Company is experiencing extreme supply and demand...

AI summary The text describes a tariff mechanism that provides customers with bill credits in exchange for reducing their electric demand during periods of extreme supply and demand conditions. To participate, customers must reduce demand during specified time periods, with the company providing a minimum of 30 minutes' notice for such requests.

COMPLIANCE INCENTIVE:
COMPLIANCE INCENTIVE: If the customer's actual metered demand during a reduction period is greater than the FDL, the customer will be charged a compliance incentive of $3.50 per kW for each kW above the FDL during each hour of the reductio...

AI summary The text outlines the compliance incentive structure for customers participating in a demand reduction program. If a customer's metered demand exceeds the Firm Demand Level (FDL) during a reduction period, they are charged $3.50 per kW for the excess. The maximum penalty includes the forfeiture of the demand credit plus $9.00 per kW of annual actual demand reduction. The annual reduction is calculated as the difference between the Normal Electric Demand (NED) and the FDL during the OPEC Peak Period, with a grace period of two 30-minute intervals of non-compliance per year.

LIMITS ON DEMAND REDUCTION:
LIMITS ON DEMAND REDUCTION: Maximum Hours of Demand Reduction per Day: 8

AI summary The document specifies a regulatory limit on demand reduction activities, establishing a maximum of 8 hours of demand reduction permitted per day.

N-40RIRs Attachment SEB-NSPI - 2a, pt. 5 (Large File - 20 MB) 3 passages
LIMITATIONS ON INTERRUPTIONS: Interruptions under this Rider are limited as follows:
LIMITATIONS ON INTERRUPTIONS: Interruptions under this Rider are limited as follows: Daily Limit: No more than two curtailments per calendar day of up to a total of 12 hours, measured from midnight to midnight, except in system emergencies...

AI summary This text outlines the limitations and operational rules for load curtailments under an interruptible power service rider. It establishes a daily limit of two curtailments (up to 12 hours total) and an annual limit of 200 hours, with fractions of an hour rounding up. The Company maintains the right to perform one-hour test interruptions, particularly if the customer has been compliant. It also defines the measurement of interruption time and specifies that limits are waived during system emergencies or public power shortage pleas.

Flat Price Interruptible
Flat Price Interruptible Flat Price Interruptible, or FPI, is a simple interruptible product designed for SIC qualified customers wbo can curtail load quicl?-l;Ji duTing periods of /:J(e;/:J demand.

AI summary The text introduces the Flat Price Interruptible (FPI) product, which is a simplified interruptible offering. It is specifically designed for customers who meet certain Standard Industrial Classification (SIC) qualifications and are capable of curtailing their electricity load during periods of high demand.

SCHEDULE CS CURT AILABLE SERVICE
SCHEDULE CS CURT AILABLE SERVICE (Continued) - II. NOTIFICATION, CURTAILMENT PROVISIONS , AND MONTHLY BILLING TO THE CUSTOMER (Continued) - D. When notification of requested curtailment is provided at a time other than during a potential c...

AI summary This section of Schedule CS outlines the notification, curtailment, and billing procedures for customers participating in a curtailable service. It specifies that customers must reduce load to their firm demand within 30 minutes of notification. Requirements include the customer's responsibility for dedicated telecommunication costs and a $50.00 monthly administrative charge. Additionally, it defines the payment structure for specific rate schedules, where payments are based on the difference between average demand during potential curtailment periods and the firm demand level.

N-40RIRs Attachment SEB-NSPI - 2a, pt. 3 (Large File - 23 MB) 17 passages
Availability of Service.
Availability of Service. Available for interruptible service to customers operating at 34,500 volts or higher if the Company has surplus capacity in operative generating equipment, transmission lines, and principal substation transformers...

AI summary The document outlines the conditions under which interruptible service is available to customers operating at 34,500 volts or higher. Service is contingent upon the Company having surplus capacity in its generating equipment, transmission lines, and principal substation transformers that exceeds the requirements of other customers. Customers must contract for sufficient capacity to meet normal maximum requirements, with a minimum contractual capacity of 10,000 kVA.

CONTRACT OPTION
CONTRACT OPTION Customer may, at Customer's option, contract with Company to curtail service upon notification by the Company. Requests for curtailment shall not exceed 'live hundred (500) hours per year nor shall any single request for cu...

AI summary This section outlines the contractual terms for customer-initiated service curtailment. It specifies operational limits, including a maximum of 500 hours per year, with individual requests ranging from 30 minutes to 14 hours. It details three distinct methods for measuring compliance and calculating monthly credits based on firm demand, designated curtailable load, or the option for the Company to sell a block of power to meet the curtailment request. The Company must provide at least ten minutes' notice for any curtailment request or cancellation.

Primary Transmission
Primary Transmission Demand Credit of: $ 4.19 per I0N $ 4.09 per KW Non-Compliance Charge of: $16.00 per 'r $16.00 per I0N Failure of Customer to curtail when requested to do so may result in termination of service under this rider.

AI summary This section outlines the specific pricing structure for the Curtailable Service Rider 2 (CSR2), detailing the Demand Credit and Non-Compliance Charge for both Primary and Transmission services. The Demand Credit is set at $4.19 per I0N for Primary and $4.09 per KW for Transmission. Additionally, a Non-Compliance Charge of $16.00 per I0N is applicable to Primary service. The document specifies that failure to comply with curtailment requests may lead to the termination of service.

POWER FACTOR PROVISION
POWER FACTOR PROVISION The monthly demand charge shall be decreased .4% for each whole one percent by which the monthly average power factor exceeds 80% lagging and shall be increased .6% for each whole one percent by which the monthly ave...

AI summary The document outlines the Power Factor Provision, which establishes a mechanism for adjusting monthly demand charges based on a customer's monthly average power factor. Customers who exceed a power factor of 80% lagging receive a 0.4% decrease for each whole one percent above that threshold. Conversely, customers with a power factor below 80% lagging face a 0.6% increase for each whole one percent below. The power factor is measured using a reactive component meter combined with a standard watt-hour meter.

AVAILABILITY OF SERVICE
AVAILABILITY OF SERVICE This rider shall be made available to customers seNed under the applicable power schedules who contract for not less than 1 ,000 kilowatts of their total requirements to be subject to curtailment upon notification b...

AI summary The text defines the eligibility requirements for a specific rider regarding the availability of service. It specifies that the rider is available to customers under applicable power schedules who contract for a minimum of 1,000 kilowatts of their total requirements. These customers must be subject to curtailment upon notification by the Company.

CONTRACT OPTION
CONTRACT OPTION Customer may, at Customer's option, contract with Company to curtail seNice upon notification by the Company. Requests for curtailment shall not exceed five hundred (500) hours per year nor shall any single request for curt...

AI summary The text outlines the contractual terms for a curtailable service option between a customer and a utility company. It specifies the parameters for load curtailment, including annual hour limits (500 hours), minimum and maximum durations per day (30 minutes to 14 hours), and notice requirements (10 minutes). It details three distinct contractual methods for measuring compliance and calculating monthly credits based on firm demand, contracted curtailable load, or the option to purchase power blocks during curtailment events.

Curtailable Service Rider 2
Curtailable Service Rider 2 purchase of power, if that is Customer's intention, and the block of power to be purchased shall be specified by Customer at the time Company makes the request for curtailment. Should Customer elect to purchase...

AI summary The text outlines the 'buy-thru' provision and credit mechanisms under the Curtailable Service Rider 2 (CSR2). Customers who opt to purchase power during a curtailment event are responsible for the full cost of the block of power, regardless of actual consumption. If the purchased power is insufficient to meet the curtailment request, the deficiency is treated as non-compliance. This option is only available to customers with a three-year history of compliance under CSR2. Additionally, customers receive credits in months where no curtailment is requested based on the difference between billing demand and contracted firm or curtailable demand.

RATE
RATE Customer will receive a credit against the applicable power schedule for curtailable 'rWV, as determined in the preceding paragraph, times the applicable credit. Customers will be charged for the portion of each requested curtailment...

AI summary The text outlines the financial structure of the Curtailable Service Rider 2 (CSR2), detailing how customers receive credits for curtailable load and are charged for unmet curtailment requests. It specifies the Demand Credit and Non-Compliance Charge rates, which differ between primary and transmission components. Additionally, it establishes a penalty for non-compliance, noting that failure to curtail when requested may lead to the termination of service.

RIDER NO.4 INTERRUPTIBLE POWER SERVICE Applicable to Rate Nos. 22, 41, 42 and 53
RIDER NO.4 INTERRUPTIBLE POWER SERVICE Applicable to Rate Nos. 22, 41, 42 and 53 Availability of Rider No. 4 is limited to customers taking service under this rider on N December 31 , 1996, and only on the amount of service under contract...

AI summary The document defines the terms and limitations of Rider No. 4, which provides Interruptible Power Service to specific customers. Eligibility is restricted to those who contracted for the service by December 31, 1996, based on their service amounts as of that date. To qualify, customers must agree to interrupt at least 1,000 kW of their electric requirement upon the Company's request. The Company maintains the right to determine interruption times and durations, subject to an aggregate system load limit of 64,000 kW in the East System.

GENERAL:
GENERAL: The Company reserves the right to assure itself that any agreed upon interruptible load has a reasonable probability of being on the Company's system during peak load periods and can be readily interrupted. The Company also reserv...

AI summary The Company establishes terms and conditions for interruptible loads, asserting the right to ensure such loads are present on the system during peak periods and can be readily interrupted. It reserves the right to mandate additional metering at the customer's expense to verify interruptions. Furthermore, the Company explicitly disclaims all liability for any loss, damage, or injury resulting from the interruption or curtailment of these loads as stipulated in the agreement.

RIDER NO. 4 INTERRUPTIBLE POWER SERVICE (Cont.)
RIDER NO. 4 INTERRUPTIBLE POWER SERVICE (Cont.) Any interruptible customer shall notify the Company in writing in the event that it desires to discontinue interruptible service under this Rider and convert interruptible load to firm servic...

AI summary This text outlines the procedures for customers under Rider No. 4 (Interruptible Power Service) to discontinue interruptible service and convert their load to firm service. It specifies that customers must provide written notice to the Company, which must then return the customer to firm service as promptly as possible, subject to the Company's Rules and Regulations. The rider is applicable to Large General Service, Time-of-Use at Transmission Voltage in the North System, specifically for customers with permanent time-of-use metering.

Large General Service, LNP/LNO , continued
o paid the bill is delinquent and a late payment charge, which is equal to 1.5 percent per month of the past due amount or such portion that remains unpaid after each subsequent month, shall be added. Issued: November 9, 1995 Issued by: Br...

AI summary This document excerpt details the terms of Rider No. 57 for Electric General Service and Large General Service Curtailment Service in the North System. It defines the peak and off-peak time periods, including specific holidays. The rider is available to customers who can demonstrate a continuing ability to curtail 250 kW or more (or 100 kW for returning customers) during specified periods. It also outlines the character of the service and the net monthly rate structure.

Rider No. 57 to Electric General Service and Large General Service- Curtailment Service (con't)
Rider No. 57 to Electric General Service and Large General Service- Curtailment Service (con't) customer, provided the customer was alerted to the possibility of curtailment 12 or more hours prior to the beginning of the curtailment period...

AI summary The text outlines the operational rules for Rider No. 57, which governs the Curtailment Service for Electric General Service and Large General Service. It specifies notice requirements for curtailments intended to avoid MAPP capacity purchases (12 hours notice, with a 2-hour minimum) and those due to operating conditions. It also defines the maximum duration of curtailment periods, the annual limit of 16 such periods during summer peak months, and the methodology for randomly rotating curtailable groups. Finally, it establishes a statewide limit of 190,000 kW for total curtailable load.

DEFINITIONS:
DEFINITIONS: Curtailment Service: Electric service which includes a credit for those customers who agree, on notice from the Company, to reduce electric demand to a predetermined level (firm power level). Firm Power Level: The level to whi...

AI summary This document excerpt provides formal definitions for terms related to 'Curtailment Service' and 'Firm Power Level' within the context of the Company's electric service. It defines 'Curtailable Load' as the difference between expected load at system peak and the agreed firm power level. The text also specifies the applicability of the Large General Service Time-of-Use at Transmission Voltage Price Schedule (LXP/LXO) to the South System territory.

TIME-OF-USE PERIODS:
TIME-OF-USE PERIODS: Peak Periods: All time occurring after 9:00a.m., but before 10:00 p.m. each weekday, Monday through Friday, excluding specified holidays. Off-Peak Periods: All hours not designated as on-peak hours. Specified Holidays:...

AI summary This text outlines the terms for Rider No. 2 to Electric General Service and Large General Service (Curtailment Service) in the South System. Customers qualifying for this rider must demonstrate the ability to curtail 100 kW to 250 kW of load during specified periods. The rider provides annual credits per kW of curtailable load based on contract length (3-year, 5-year, or year-to-year). It also establishes reimbursement terms if a customer's failure to curtail forces the Company to purchase capacity from the Mid-Continent Area Power Pool (MAPP).

Rider No. 2 to Electric General Service and Large General Service (Except Price Schedule LCL) -Curtailment Service (can't)
Rider No. 2 to Electric General Service and Large General Service (Except Price Schedule LCL) -Curtailment Service (can't) Option B customers may request a change in the firm power level annually. In addition, on 24 hours' notice, customer...

AI summary This document outlines Rider No. 2 for Electric General Service and Large General Service regarding Curtailment Service. It details two options for customers: Option B allows for annual firm power level changes and 24-hour service cancellation (with forfeiture of summer credits), while Option A requires immediate notification for increases. The Company reviews expected loads annually and may adjust minimum firm power levels based on historical demand. It also includes provisions for standby generators, minimum billing, and tax adjustments.

Rider No.2 to Electric General Service and Large General Service (Except Price Schedule LCL) -Curtailment Service (con't)
Rider No.2 to Electric General Service and Large General Service (Except Price Schedule LCL) -Curtailment Service (con't) r customer, provided the customer was alerted to the possibility of curtailment 12 or more hours prior to the beginni...

AI summary The text outlines the operational procedures for Rider No.2 Curtailment Service, specifically regarding notice periods and duration for load curtailment. It specifies that customers must be notified 12 hours in advance, unless the Company provides 2-hour notice to avoid MAPP capacity purchases. Curtailment periods are capped at 6 hours or until notice of termination. The Company will randomly group participants by net C loads and rotate between groups. Participation is limited to a state-wide total of 190,000 kW.

86472Submission - Re: Future Filing Requirements and comments on Board Draft Strawman 1 passage
SR - Studies and Reports {latest available)
SR - Studies and Reports {latest available) - I. Cost of Service study in electronic format, including all assumptions, calculations and workpapers - 2. Load Forecast report C - Organization Profile MS Word or Excel documents as required,...

AI summary The document outlines the submission requirements for a Cost of Service study and a Load Forecast report, both in electronic format, as well as the formatting guidelines for Organization Profile documents in MS Word or Excel, following Court of Appeal formatting standards.

86475Board Letter - Re: NSPI Future Filing Requirements - Strawman Proposal - April 10, 2007 1 passage
SR - Studies and Reports (latest available)
SR - Studies and Reports (latest available) - 1. Cost of Service study - 2. Load Forecast report

AI summary The document lists two studies and reports: the Cost of Service study and the Load Forecast report. These documents are part of the regulatory proceeding and provide essential data for analysis.

Disclaimer: These summaries were generated by AI from the filings they describe. We take care to make them accurate, but errors are possible - and they aren't advice. Only the filings themselves are the record: if you're relying on something here, confirm it against the source documents or the Nova Scotia Energy Board's own record. Full disclaimer →