The following charges shall apply: (a) Connection or reconnection of electric service, whether $21.00 standard metered or unmetered, to any premises during the Company's charge normal working hours. (b) Connection or reconnection of electr...
AI summary The document specifies the standard charges for connecting or reconnecting electric service to premises. A standard charge of $21.00 applies during normal working hours for both metered and unmetered services. For requests made outside of normal working hours (provided it is not a reconnection due to non-payment), a base charge of $21.00 is applied plus an additional $57.00 charge to cover extra costs.
(c) Reconnection of electric service, whether metered or unmetered, to any premises after the Company's normal working hours, if requested by the Customer and is a reconnection associated with non payment. $21.00 standard charge plus $57.0...
AI summary The text outlines specific tariff charges and fees related to the disconnection and reconnection of electric service. It defines standard charges for reconnections occurring outside of normal working hours due to non-payment, reconnections for temporary services, and seasonal service disconnections. Additionally, it specifies standard fees for collection notices sent via different methods (disconnection notice vs. registered mail) and a charge for returned cheques.
7.1 SCHEDULE OF CHARGES (h) Interest on Overdue Accounts 1.5% per month or part thereof, or a maximum of 19.56% per annum (i) Interest on Deposits Interest Rate based on Royal Bank prime rate minus 1 %; set January 1st of each year (j) Dis...
AI summary This section outlines the specific schedule of charges approved by the Nova Scotia Utility and Review Board. It details various fees including interest rates on overdue accounts (1.5% monthly), interest on deposits (linked to the Royal Bank prime rate), and specific costs for meter dispute tests, three-phase service contributions, and recording equipment installation. It also specifies annual fees for pole attachments and monthly charges for mobile radio network access.
7.1 SCHEDULE OF CHARGES (h) Interest on Overdue Accounts 1.5% per month or part thereof, or a maximum of 19.56% per annum (i) Interest on Deposits Interest Rate based on Royal Bank prime rate minus 1 %; set January 1st of each year Dispute...
AI summary This section outlines the Schedule of Charges for various services and fees. It specifies interest rates for overdue accounts (1.5% monthly) and deposits (Royal Bank prime rate minus 1%). It also lists fixed fees for three-phase service contributions, recording equipment installation, miscellaneous requests, telecommunication pole attachments, and specific monthly charges for access to the NSPI Mobile Radio Network.
7.2 SCHEDULE OF WIRING INSPECTION FEES When a dispute arises regarding the cost of an electrical installation the permit applicant may be required, at the Inspection Authority discretion, to supply a letter from the owner indicating the va...
AI summary The document outlines the procedures and fee structures for electrical wiring inspections. It specifies that in the event of a cost dispute for an electrical installation, the Inspection Authority may request the permit applicant to provide a contract value letter or a bill of materials. Furthermore, it establishes that fees for Regular Permits and Inspections, including the number of visits allowed, are determined based on the Installed Value of the project as defined in the Inspection Fee Schedule.
c) Special Permits and Inspections Where the fee for a Regular Permit and Inspection are inappropriate the special permit and inspection fee shall apply. (Ex. carnivals and travelling shows).
AI summary The document specifies the application of fees for Special Permits and Inspections. It establishes that these fees should be utilized in instances where the standard Regular Permit and Inspection fees are deemed inappropriate for the specific nature of the activity, providing examples such as carnivals and traveling shows.
7.2.2 Late Application Fee Where an electrical contractor fails to obtain an electrical wiring permit prior to commencing the electrical work, an additional fee shall be payable in the amount of fifty (50) percent of the regular fee, up to...
AI summary The document specifies a late application fee for electrical contractors who begin electrical work without first obtaining a required wiring permit. The penalty is set at fifty percent of the regular permit fee, capped at a maximum additional charge of $100.00.
7.2 SCHEDULE OF WIRING INSPECTION FEES When a dispute arises regarding the cost of an electrical installation the permit applicant may be required, at the Inspection Authority discretion, to supply a letter from the owner indicating the va...
AI summary This section outlines the procedures and basis for determining wiring inspection fees in the event of a cost dispute. It specifies that the Inspection Authority may require permit applicants to provide documentation, such as a contract value letter or a bill of materials, to establish the project's value. Furthermore, it establishes that fees for Regular Permits and Inspections, including the number of visits allowed, are determined by the Installed Value of the installation according to the Inspection Fee Schedule.
c) Special Permits and Inspections Where the fee for a Regular Permit and Inspection are inappropriate the special permit and inspection fee shall apply. (Ex. carnivals and travelling shows).
AI summary The document specifies the conditions under which special permit and inspection fees apply. It establishes that these fees should be utilized in instances where the standard Regular Permit and Inspection fees are deemed inappropriate for the specific nature of the activity, citing carnivals and travelling shows as primary examples.
7.2.4 Refund ofFees The holder of a permit may apply to the inspection authority for a refund less a $10.00 non-refundable portion of the permit fee with respect to a cancelled or unused permit. No refund shall be issued for a permit where...
AI summary This section outlines the procedures and conditions for obtaining a refund on permit fees. Permit holders may request a refund for cancelled or unused permits, subject to a $10.00 non-refundable fee. However, refunds are explicitly denied for permits where an inspection call has already been initiated at the permit holder's request.
7 .2.4 Refund of Fees The holder of a permit may apply to the inspection authority for a refund less a $10.00 non-refundable portion of the permit fee with respect to a cancelled or unused permit. No refund shall be issued for a permit whe...
AI summary The text outlines the conditions under which a permit holder can request a refund for a cancelled or unused permit from the inspection authority. It specifies that a $10.00 non-refundable portion of the permit fee will be deducted from any refund issued. Furthermore, it clarifies that no refund is available if an inspection call has already been initiated at the request of the permit holder.
INSPECTION FEE SCHEDULE INSTALLED VALUE OF INSPECTION ELECTRICAL VISITS PERMIT FEE INSTALLATION $ 0,000 to$ 2,000 1 $ 55.00 $ 2,001 to$ 4,000 2 $ 111.00 $ 4,001 to$ 6,000 2 $ 185.00 $ 6,001 to $ 8,000 2 $ 233.00 $ 8,001 to $ 10,000 2 $ 283...
AI summary The document outlines the approved inspection fee schedule for electrical installations in Nova Scotia. It provides a tiered pricing structure for permit fees based on the installed value of the electrical work, ranging from $55.00 for small installations to a base fee plus a percentage for projects exceeding $1,000,000. Additionally, it specifies minimum inspection fees for new residential, commercial, industrial, and institutional installations based on amperage.
Scheduled inspections on weekends (Saturday, Sunday) and statutory holidays: i) For the first hour or fraction thereof $112.00 ii) For each additional half-hour or fraction thereof $40.00 h) Inspections in Excess of Maximum Number of Visits
AI summary The document specifies the fee structure for inspections conducted on weekends (Saturday and Sunday) and statutory holidays. The pricing is set at $112.00 for the first hour or fraction thereof, with an additional charge of $40.00 for each subsequent half-hour or fraction thereof. It also references a provision for inspections that exceed the maximum number of permitted visits.
NOVA SCOTIA POWER INCORPORATED 4.0 Analysis and Reporting Base Package See Charge per Billing Period Load profile for peak day billing period plus times and magnitude of six highest peaks 33.00 Options Data File 33.00 Load profile for each...
AI summary The document outlines a pricing schedule for Nova Scotia Power Incorporated (NSPI) regarding analysis and reporting services. It specifies charges per billing period for various load profile analyses, power factor plots, and daily/weekly/monthly summaries. Additionally, it lists a specific charge for 'Specialized Analysis' under an 'Hourly Rate' category. The text indicates these charges are approved by the Nova Scotia Utility and...
7.3 SCHEDULE OF LOAD RESEARCH MONITORING, REPORTING AND ANALYTICAL CHARGES 4.0 Analysis and Reporting See Charge per Billing Period Base Package Load profile for peak day billing period plus times and magnitude of six highest peaks 33.00 O...
AI summary This section outlines the specific charges for load research, monitoring, reporting, and analytical services provided by the utility. It details a 'Base Package' for load profiles and peaks, various optional reporting services such as daily and monthly summaries, load duration plots, and daily consumption plots, as well as specialized analysis including hourly rates. The charges are structured to provide customers with granular data on their electricity usage patterns.
N-1-aAppendix H - Proposed Tariffs (Large File - 21 MB)
27 passages
MAXIMUM PER KW.H CHARGE/MINIMUM BILL The maximum charge per kW.h will be that for a billing load factor of 10% except that the minimum monthly bill shall not be less than $12.65.
AI summary The document specifies the calculation for the maximum charge per kW.h, which is based on a billing load factor of 10%. It further establishes a minimum monthly bill amount of $12.65, ensuring that customers are not charged below this threshold regardless of their actual usage.
MAXIMUM PER KW.H CHARGE/MINIMUM BILL The maximum charge per kW.h will be that for a billing load factor of 10% except that the minimum monthly bill shall not be less than $12.65.
AI summary The text specifies the calculation method for the maximum charge per kilowatt-hour (kW.h) based on a billing load factor of 10%. It also establishes a minimum monthly bill threshold of $12.65, ensuring that customers are not charged less than this amount regardless of their actual consumption.
SPECIAL CONDITIONS: - (1) Metering will normally be at the low voltage side of the substation. Should the customer's requirements make it necessary for the Company to provide primary metering, then the customer will be required to make a c...
AI summary The document outlines specific conditions for utility service, focusing on metering and transformer ownership. It specifies that metering is typically on the low voltage side; however, if primary metering is required due to customer needs, the customer must provide a capital contribution for the additional costs. It also notes a 1.75% reduction in metered kWh usage for high-voltage side metering. Additionally, the Company may require customers to own transformers for non-standard service provisions.
SPECIAL CONDITIONS: (1) Metering will normally be at the low voltage side of the substation. Should the customer's requirements make it necessary for the Company to provide primary metering, then the customer will be required to make a cap...
AI summary The text outlines special conditions regarding metering locations and associated costs for customers. While metering is typically placed on the low voltage side of the substation, customers requiring primary metering must provide a capital contribution for the additional costs over secondary metering. It also specifies adjustment factors for metered kW.h usage based on substation high voltage levels, requiring a 1.75% reduction if metering is on the high voltage side of a 69 kV substation, and a 1.75% increase if on the low voltage side of a substation below 69 kV.
NOVA SCOTIA POWER INCORPORATED LARGE GENERAL TARIFF (2 000 kV.A or 1 800 kW, and Over) Rate Code 12 - (2) The Company will withdraw the availability of this tariff to any specific customer, if, on a consistent basis, the customer is not ma...
AI summary The text outlines the terms for the Large General Tariff (Rate Code 12) for Nova Scotia Power Incorporated. It specifies that the Company will withdraw the tariff from customers who consistently fail to maintain a billing demand of at least 2,000 kV.A or 1,800 kW. Additionally, the Company reserves the right to establish separate service or operating agreements to address issues not covered by the tariff for the benefit of the Company and its customers.
SPECIAL CONDITIONS: - (1) Metering will normally be at the low voltage side ofthe substation. Should the customer's requirements make it necessary for the Company to provide primary metering, then the customer will be required to make a ca...
AI summary The text outlines special conditions for metering and service provisions. It specifies that metering is typically located on the low voltage side of the substation; however, if a customer requires primary metering, they must provide a capital contribution for the additional costs. It also notes a 1.75% reduction in metered kilowatt-hour usage when metering is on the high voltage side. Furthermore, the Company may require customers to own transformers for non-standard service provisions.
MAXIMUM PER KW.H CHARGE/MINIMUM BILL The maximum charge per kW.h will be that for a billing load factor of 10% except that the minimum monthly bill shall not be less than $12.65.
AI summary The document specifies the calculation for the maximum charge per kilowatt-hour (kW.h) based on a billing load factor of 10%. It also establishes a mandatory minimum monthly bill of $12.65, ensuring that customers are not charged less than this amount regardless of their actual consumption.
SPECIAL CONDITIONS: - (1) Metering will normally be at the low voltage side of the substation. Should the customer's requirements make it necessary for the Company to provide primary metering, then the customer will be required to make a c...
AI summary The document outlines special conditions for a specific tariff, primarily focusing on metering requirements and customer eligibility. It specifies that metering is typically at the low voltage side; however, if primary metering is required due to customer needs, the customer must provide a capital contribution for the additional costs. It also notes a 1.75% reduction in metered kilowatt-hour usage for high voltage side metering and establishes a minimum billing demand of 250 kV.A (225 KW) for continued tariff availability.
SPECIAL CONDITIONS: - (1) Metering will normally be at the low voltage side of the substation. Should the customer's requirements make it necessary for the Company to provide primary metering, then the customer will be required to make a c...
AI summary The document outlines special conditions for a specific utility tariff. It specifies that metering typically occurs on the low voltage side of the substation; however, if a customer requires primary metering, they must provide a capital contribution covering the additional costs relative to secondary metering. Furthermore, it establishes a 1.75% reduction in metered kWh usage for high-voltage side metering and grants the Company the right to withdraw the tariff from customers who do not maintain a minimum billing demand of 250 kV.A (225 KW).
SPECIAL CONDITIONS: - ( 1) The Company reserves the right to have a separate service agreement if in the opinion of the Company, issues not specifically set out herein must be addressed for the ongoing benefit of the Company and its custom...
AI summary The text outlines special conditions for electricity supply agreements, emphasizing the Company's right to establish separate agreements for specific customer needs. It mandates that customers ensure their load does not compromise power supply system integrity, covering factors such as reliability, harmonics, voltage flicker, and stability. Additionally, it specifies adjustments to meter readings based on the voltage level of the supply point to account for transformer losses.
Customer Load Factor (CLF) (%): CLF kWh consumed during billing period under this rate + kWh actually interrupted (Tariff Demand (TD) x hours in month) In the above formula, kWh actually interrupted will be calculated as the kW curtailed m...
AI summary The document defines the calculation methodology for Customer Load Factor (CLF) used in electricity billing. It specifies that CLF is determined by the kilowatt-hours (kWh) consumed during a billing period plus the kWh actually interrupted (calculated as kW curtailed multiplied by hours curtailed). The formula accounts for changes in Tariff Demand (TD) during the month and provides specific instructions for billing periods involving pre-arranged down time, where energy is calculated based on normal and lower TD values.
10. Verification of Interruption: For each Interruption event, the Company shall, using meter data collected at designated metering points, confirm the response time, duration and amount of load Interrupted by the customer. For the purpose...
AI summary The text outlines the requirements for the Company to verify power interruptions. It specifies that the Company must use meter data from designated points to confirm the response time, duration, and amount of load interrupted. The customer load at the time of the call is determined by averaging the metered loads from the two fifteen-minute billing intervals preceding the call. To qualify for the rate, at least 95% of the requested load must be interrupted for the specified duration.
11 . Verification of Ability to Interrupt: Unless, within the most recent 12-month period, the customer has demonstrated the ability to interrupt load, either by a test or for economic or system reasons, the Company may at its sole discret...
AI summary The text outlines the procedures for verifying a customer's ability to interrupt load. If a customer has not demonstrated this ability within the last 12 months through testing or for economic/system reasons, the Company reserves the right to conduct periodic tests. These tests involve an interruption call and a maximum one-hour service interruption. Failure to comply with the interruption request results in penalties, and the Company may conduct additional tests if the verification process is not successfully completed.
12. Billing Order for Multiple-Rate Customers: All energy taken by the customer at or above the upper limit of the Tariff Demand level shall be billed under the applicable Real Time Pricing rate. The customer will set an upper and lower th...
AI summary The document outlines the billing order for customers utilizing multiple-rate structures. It specifies that energy consumption at or above a customer-defined upper threshold (in kW) will be billed under the Real Time Pricing (RTP) rate. Conversely, energy consumption below a defined lower threshold may be billed under any Nova Scotia Power International (NSPI) rate for which the customer is eligible.
19. Billing: Applicable Energy Charges, penalties, Buy-Through costs and adjustments will be calculated by the Company and indicated on the customer's monthly bill.
AI summary The text specifies that the Company is responsible for calculating and displaying various charges on customer monthly bills. These include applicable energy charges, penalties, Buy-Through costs, and other adjustments, ensuring that customers are informed of the costs associated with their electricity usage.
AHLS Base Cost (AHLSbc) This is the total monthly charge (in dollars), calculated by applying the customer's qualifying alternative rate ("QAR") to the unaltered billing determinants from the Annual Hourly Load Shape. This pre-determined c...
AI summary The text defines the Annual Hourly Load Shape Base Cost (AHLSbc), which is a pre-determined monthly charge for customers on qualifying alternative rates (QAR). Unlike energy charges, the AHLSbc is payable regardless of actual energy consumption during a billing period. It is calculated by applying the customer's QAR to the unaltered billing determinants of the Annual Hourly Load Shape, which includes both demand charges and energy charges based on the full 8760 (or 8784) hour load shape.
TWO PART REAL TIME PRICING TARIFF Projections of the anticipated hourly energy price (week ahead and day ahead) will be provided to the customer according to the following schedule: - By midnight each day, hourly price forecasts for each h...
AI summary The document outlines the notification and billing procedures for the Two Part Real Time Pricing (2P-RTP) tariff. It specifies that hourly energy price forecasts for the upcoming seven days must be provided to customers by midnight each day, with immediate notification of major changes. Furthermore, it establishes that the actual price applied for billing is the marginal cost forecast provided 20 minutes prior to each hour.
Decremental Shifted Load (DSL) This is the hourly energy considered to have been shifted to a lower cost period. It is calculated as the difference between the CBL and the actual demand when actual demand is less than the CBL.
AI summary The document defines Decremental Shifted Load (DSL), which represents the hourly energy shifted to a lower-cost period. DSL is calculated by finding the difference between the Customer Billing Line (CBL) and the actual demand, but only in instances where the actual demand is lower than the CBL.
Incremental Shifted Load (ISL) This is the hourly energy considered to have been shifted from a higher-cost period. It is calculated as the difference between the actual load and the CBL whenever the actual load exceeds the CBL.
AI summary The text defines the Incremental Shifted Load (ISL) metric, which represents hourly energy shifted from high-cost periods. It is calculated by determining the difference between the actual load and the Customer Billing Line (CBL) specifically during instances where the actual load exceeds the CBL.
Standard Practice of Setting a CBL The customer will be able to choose, depending on his specific load shape and operational requirements, an 8760 (8784) hour CBL Shape based on either of the following: The exact one year historic load sha...
AI summary The document outlines the standard practice for establishing a Customer Billing Line (CBL) shape for customers under the Two Part Real Time Pricing tariff. It specifies two options for customers: using an exact one-year historic load shape (adjusted for seasonality and maintenance) from a period prior to load-shifting behaviors, or developing a custom Annual Hourly Load Shape, provided the customer can demonstrate that the custom shape reasonably represents actual annual load data.
Term of the CBL The CBL will be set for five years, subject to modification as set out in the rate, or as may otherwise be agreed with NSPI.
AI summary The text specifies the duration of the Customer Billing Line (CBL), stating that it will be established for a five-year term. It notes that this term is subject to potential modification as outlined in the rate application or through mutual agreement with Nova Scotia Power International (NSPI).
Modification of Existing CBL If an existing 2P-RTP customer undertakes significant physical plant modification, (as signified by a specific capital expenditure above and beyond normal annual capital spending) or other material change (such...
AI summary The text outlines the conditions under which the Customer Billing Line (CBL) for 2P Real Time Pricing (2P-RTP) customers may be modified. Adjustments can be proposed by the Company or the customer due to significant physical plant modifications, capital expenditures, or material changes in product lines. Additionally, the CBL may be lowered or suspended in cases of significant load reductions. The annual energy consumption component of the CBL can be reset yearly by mutual agreement, with the UARB serving as the adjudicator for any disputes.
Order in which Rates are Applied With respect to the "stacking order" under which customers taking multiple rates are billed, no other rate may be taken above this rate. APPROVED: NOV A SCOTIA UTILITY AND REVIEW BOARD EFFECTIVE: JANUARY 1,...
AI summary The Nova Scotia Utility and Review Board established a 'stacking order' for customers who utilize multiple rates simultaneously. The order stipulates that no rate may be applied above a specific designated rate, ensuring a clear hierarchy in how multiple rate components are billed to customers.
Bill Calculation: At the end of each month: Total Bill= AHLSbc \ + Incremental Charges - Decremental Rebate - Incremental Export Benefit Credit \ If this rate is being taken with ELIIR, CBLbc will be used instead of AHLSbc·
AI summary The text outlines the monthly bill calculation formula for customers under specific rate structures. The total bill is determined by multiplying the Annual Hourly Load Shape Base Cost (AHLSbc) by a rate factor, then adjusting for incremental charges, decremental rebates, and incremental export benefit credits. It further specifies that if the Energy Literacy and Inclusion Initiative (ELIIR) is applied, the Customer Billing Line base cost (CBLbc) replaces the AHLSbc in the calculation.
UET This is the upper boundary in kW, as agreed to by both NSPI and the customer. The difference between this boundary and the LET defines the TD for the customer's ELIIR pricing during the active rate year. Any load reduction in any hour...
AI summary The text defines the Upper ELIIR Threshold (UET) as the maximum power boundary in kW agreed upon by Nova Scotia Power International (NSPI) and a customer. The difference between the UET and the Lower ELIIR Threshold (LET) determines the Time of Day (TD) for the customer's ELIIR pricing during an active rate year. Crucially, any load reductions occurring below the UET are excluded from the calculation of the Decremental Load Shift.
MAXIMUM PER KW.H CHARGE/MINIMUM BILL The maximum charge per kW.h will be that for a billing load factor of 10% except that the minimum monthly bill shall be $12.65 per month if such unmetered service is billed separately from any metered a...
AI summary The document specifies the billing rules for unmetered service, establishing a maximum charge per kW.h based on a billing load factor of 10%. It further defines a minimum monthly bill of $12.65, which applies specifically when unmetered service is billed as a separate item from any metered account.
MAXIMUM PER KW.H CHARGE/MINIMUM BILL The maximum charge per kW.h will be that for a billing load factor of 10% except that the minimum monthly bill shall be $12.65 per month if such unmetered service is billed separately from any metered a...
AI summary The document specifies the pricing structure for unmetered service, establishing a maximum charge per kilowatt-hour based on a billing load factor of 10%. Additionally, it mandates a minimum monthly bill of $12.65 for unmetered service when it is billed independently from a metered account.
N-7-aRIRs 8 to 23 - HRM to NSPI - REDACTED
8 passages
Question IR-10: With respect to the responses to HRM IR-6: - a. In response to HRM IR-6(a)(i), please estimate how many street lighting f'txture changes NSPI is processing in a one-year period. Approximately what percent is occurring withi...
AI summary The Halifax Regional Municipality (HRM) is requesting detailed operational data from Nova Scotia Power Inc. (NSPI) regarding customer service and billing activities. The inquiry seeks specific metrics on street lighting fixture updates, residential customer turnover rates, and the processing times for move-ins and move-outs. Additionally, HRM requests data on credit checks, deposit calculations, and the volume and duration of residential billing inquiries, as well as historical and projected billing data for street lighting fixtures.
RESPONSE TO INFORMATION REQUEST TO: NSPI FROM: HRM REDACTED Response IR-10: (cont'd) seven minutes and 50 seconds. This includes call time and post call processing time. d. - Residential credit checks and customer deposits are not included...
AI summary The Halifax Regional Municipality (HRM) provided a response to an Information Request regarding Nova Scotia Power Inc.'s (NSPI) call centre and billing processes. The text specifies that residential credit checks and customer deposits are managed within Call Centre services rather than Billing Services. It details the estimated time for credit checks (one to two minutes), specific deposit amounts based on premises type and usage, and the associated costs for external credit rating contracts and deposit notification letters.
RESPONSE TO INFORMATION REQUEST TO: NSPI FROM: HRM REDACTED Response IR-10: (cont'd) 1v. NSPI does not track transaction times for new streetlight account requests. e. - 1. Residential billing inquiries are not included in Billing Services...
AI summary In response to Information Request IR-10, HRM clarifies that Nova Scotia Power Inc. (NSPI) does not track transaction times for new streetlight account requests. Additionally, the response distinguishes between Billing Services and Call Centre services, noting that residential billing inquiries are primarily managed by the Call Centre, with some being referred to the Billing Services group for specific follow-up or subject matter expertise.
- 11. Residential billing inquiries to the Call Centre for 2005 and 2006 are indicated in the table below: Year Total Billing Inquiries managed by Call Centre Billing Inquiries requiring Billing Services Su ort 2005 136,535 12,287 2006 (YT...
AI summary The document provides data regarding residential billing inquiries handled by the Call Centre for the years 2005 and 2006 (Year-to-Date). It specifies the total number of inquiries managed and the subset requiring additional Billing Services support. Furthermore, it notes that the average transaction time for a billing inquiry in 2006 was approximately six minutes and 21 seconds, encompassing both talk time and post-call processing, but excluding additional support time.
Response IR-10: (cont'd) • Transfer daily meter readings into Customer Information System for billing; - Process daily billing exceptions from daily bill runs; - Process daily customer inquiries, over/under billing, customer connected/disc...
AI summary Nova Scotia Power Inc. (NSPI) outlines the operational procedures for its billing and customer information management. Key activities include transferring daily meter readings into the Customer Information System, processing daily billing exceptions, and managing customer inquiries regarding billing errors, interest charges, and Budget Billing changes. Additionally, the company monitors various reports to ensure timely and accurate billing and performs testing for residential rate updates.
- g. Please refer to the following table: Year Average Number of Streetlight Fixtures 2004 133,741 2005 134,280 2006 September 135,768 2007 137,142 - h. There are 530 unmetered billing accounts with more than 10 fixtures per account.
AI summary The text provides historical data on the average number of streetlight fixtures in the service territory from 2004 to September 2007, showing a steady increase from 133,741 to 137,142. Additionally, it identifies 530 unmetered billing accounts that contain more than 10 fixtures per account.
BILLING SERVICES OPERATIONS Rate Class Total Accts % of Accounts Meter Reading Processing Billing Inquiries Large Accts requiring manual effort Unmetered Accts with more than 10 lights & LED TCL Conversions Total FTEs % of FTEs Labour Budg...
AI summary The document provides a detailed breakdown of labor and budget allocations for billing services operations across various rate classes. It quantifies the Full-Time Equivalent (FTE) requirements for meter reading processing, billing, inquiries, and manual efforts for large accounts or unmetered accounts with specific light configurations. The residential rate class accounts for the majority of the workload, representing approximately 75.17% of the total FTEs and a significant portion of the allocated labor budget.
= (Unmetered Billing Services Costs / Total Billing Services Costs) / (Total Unmetered Accounts / Total NSPI Accounts) = ($201,396 / $2,600,000) / (7,491 / 462,531) Factor Calculation Weighting Factor = 4.78
AI summary The text provides a calculation for a weighting factor used in the analysis of billing services costs. It specifically calculates the ratio of unmetered billing services costs to total billing services costs, divided by the ratio of unmetered accounts to total Nova Scotia Power Inc. accounts. The resulting weighting factor is determined to be 4.78.
N-7-aRIRs 27 to 39 - AEC to NSPI - REDACTED
10 passages
How do you know what to bill me? Qualifying customers will have their regular meter replaced with a Time-of-Day (TOO) meter. A TOO meter records the amount of power used, the time of day the usage occurred, and the season that we are in. T...
AI summary The text explains how Time-of-Day (TOD) meters enable differentiated billing for qualifying customers. These meters record electricity consumption based on the specific time of day and season, including holiday tracking. This allows the utility to bill customers at variable costs, where 'on-peak' usage incurs premium pricing and 'off-peak' usage is billed at a reduced rate (half of the standard residential rate), as illustrated by a laundry example.
Application of subsection (3) (4) Subsection (3) applies only to a customer for energy supplied on or after the fifth day of May, 1978, and upon an application from that customer.
AI summary The text specifies the conditions under which subsection (3) of a regulation is applicable. It states that the provision only applies to customers who received energy supplies on or after May 5, 1978, and requires a formal application from the customer to be enacted.
RESPONSE TO INFORMATION REQUEST TO: NSPI FROM: AEC Question IR-30: In reference to IR 8, please provide the following: a. the number of residential consumers who entered into a single settlement agreement in 2005 and 2006; b. an estimate o...
AI summary Access Energy Corporation (AEC) responded to an information request from Nova Scotia Power Inc. (NSPI) regarding residential settlement agreements in 2005 and 2006. AEC provided data showing that 27,971 and 26,346 residential consumers entered into single settlement agreements in those years, respectively. AEC clarified that these agreements are initiated for customers with arrears or late payment problems and confirmed they are identical to the 'written payment agreements' required under Regulation 6.5.
Question IR-31: In reference to IR 9, please provide the following: - a. the average cost of a disconnection for a residential customer in 2005 and 2006 (YTD)? - b. What determines the method of fmal notice delivery for a customer? - c. Cl...
AI summary The regulatory proceeding involves a request for detailed data regarding residential customer disconnections for the years 2005 and 2006. The inquiry seeks specific financial and operational metrics, including average disconnection costs, revenue from miscellaneous charges, and the volume of disconnections. Additionally, it requests clarification on notice delivery methods, whether customers are charged for multiple staff visits for notice delivery, and an explanation for the year-over-year changes in disconnection figures.
Response IR-31: - a. NSPI does not track this information. Please refer to AEC IR-9k for the cost per disconnect. - b. All customers who receive a final notice of disconnection are notified first by mail and second with follow-up telephone...
AI summary Nova Scotia Power Inc. (NSPI) clarifies its disconnection notice procedures, stating it does not track specific per-disconnect costs, referring instead to Access Energy Corporation (AEC) for that data. NSPI outlines a multi-step notification process where customers receive final disconnection notices via mail followed by telephone calls from a Customer Service Representative. If contact is unsuccessful after three attempts or if the customer denies receipt, NSPI may deliver a new notice via registered mail or field staff.
Response IR-31: (cont'd) but is not signed for, the CSR will have the final notice delivered by NSPI field staff. - c. Yes, a customer pays for each visit by NSPI staff for purpose of delivery of final notices. - d. NSPI does not forecast...
AI summary Nova Scotia Power Inc. (NSPI) provides data regarding customer disconnection procedures and associated revenues. The company notes that customers are charged for field staff visits to deliver final notices. NSPI reported a 46 percent year-to-date reduction in disconnections as of October 2006 compared to 2005, though they lack specific analysis on the cause of this decrease. Consequently, revenue from miscellaneous charges for notices and reconnections saw a 13 percent reduction year-to-date.
RESPONSE TO INFORMATION REQUEST TO: NSPI FROM: AEC Question IR-32: In relation to IR 11, please provide an explanation for the growth in multiple notices from 288 to 318 between 2005 and 2006 given the drop in the number of disconnections...
AI summary Access Energy Corporation (AEC) responds to an information request regarding the increase in multiple disconnect notices from 288 to 318 between 2005 and 2006, despite a drop in actual disconnections. Nova Scotia Power Inc. (NSPI) explains that while they prioritize negotiating settlement agreements with customers who have overdue balances, the growth in these agreements has paradoxically led to a higher number of broken arrangements and subsequent multiple disconnect notices.
Response IR-33: - a. Please refer to CA IR-74. - b. NSPI refunded 1,216 residential customer deposits in 2005 and 1,470 year to date November 29, 2006. - c. NSPI does not track this information. - d. The following circumstances would repre...
AI summary Nova Scotia Power Inc. (NSPI) provided information regarding residential customer deposit refunds, noting that 1,216 deposits were refunded in 2005 and 1,470 were refunded by November 29, 2006. The company stated that it does not track specific information regarding these refunds. Additionally, the response outlines the specific circumstances that define a "bad credit relationship" between the utility and its customers.
Response IR-33 : (cont'd) 1. The customer's service had been previously disconnected for non-payment; 11. The customer has obtained, or attempted to obtain, service through misrepresentation, tampering, theft, interference or any other rel...
AI summary This section outlines specific criteria for customer service eligibility or restrictions, particularly regarding non-payment and past behavior. It lists conditions such as previous disconnections, illegal service obtainment, recent final notices, broken payment arrangements, moving without notice, and bankruptcy claims. Nova Scotia Power Inc. (NSPI) notes that while these criteria exist, they may request a 50 percent upfront payment of arrears while allowing payment arrangements for the remaining balance.
Response IR-35: - a. NSPI has no infonnation on this working group. - b. Over the past year, NSPI has had a number of discussions with the Department of Community Services (DCS) and the Affordable Energy Coalition (AEC), on the subject of...
AI summary Nova Scotia Power Inc. (NSPI) states it has no information regarding a specific working group. However, the company notes it has engaged in ongoing discussions with the Department of Community Services (DCS) and the Affordable Energy Coalition (AEC) over the past year. These discussions focused on improving NSPI's credit and collections policies, specifically seeking to enhance support and outcomes for low-income customers.
N-40RIRs Attachment SEB-NSPI - 2a, pt. 1 (Large File - 22 MB)
41 passages
A SOUTHERN COMPANY PAGE EFFECTIVE DATE REVISION 1 of3 January, 2006 Billings Fourteenth AVAILABILITY
AI summary The provided document snippet is a cover page for a document from A Southern Company. It indicates the document's effective date as January 2006 and identifies it as the fourteenth revision of the 'Billings' document. No specific regulatory arguments or technical details are contained in this section.
The capacity for billing purposes shall be the maximum integrated fifteen (15) minute capacity during each billing period of approximately thirty (30) days, measured in kilowatts by an appropriate capacity meter; provided, however, that su...
AI summary The text defines the methodology for determining 'capacity' for billing purposes. It specifies that capacity is based on the maximum integrated fifteen-minute capacity during a thirty-day billing period, measured in kilowatts. It also establishes a floor for this measurement, stipulating that the capacity cannot be less than 90% of the measured maximum requirements from the previous eleven months, 90% of the contracted capacity, or 3,000 kW, whichever is greatest.
PAYMENT Bills for service rendered hereunder are payable within ten (10) days from the due date and if not paid within such period become delinquent and subject to charges as set forth in the Company's Rules and Regulations.
AI summary The document specifies the payment terms for services rendered, stating that bills must be paid within ten days of the due date. Failure to meet this deadline results in the account becoming delinquent and subject to charges as outlined in the Company's Rules and Regulations.
NAME OF OFFICER TITLE ADDRESS i MOIN FLECTRIC COMPANY 3 . Cumulation of Service the same customer purposes under this continue to receive Company's engineers\ninstalled at custome May 5, 1990, will no purposes with any of on the same Servi...
AI summary The provided text is a highly corrupted or improperly formatted excerpt from a regulatory proceeding. It contains fragmented sentences regarding the cumulation of services for the same customer on the same Service Class. It mentions that services installed at customer premises since May 5, 1990, will not be cumulated for billing purposes unless agreed to by the customer or otherwise specified, though the text is largely unintelligible due to repetitive artifacts.
Delivery Voltage Metering Level Meter Adjustment Billing KW Discount (1) 138,000 Volts or Higher 138,000 Volts or Higher See Rider C $0.95/kW 138,000 Volts or Higher Primary Voltage None $0.95/kW 34,500 or 69,000 Volts 34,500 Volts or High...
AI summary The document provides a table detailing billing kilowatt (kW) discounts based on delivery voltage and metering levels. It specifies discount rates of $0.95/kW for systems at 138,000 Volts or higher and $0.81/kW for systems at 34,500 or 69,000 Volts. It also notes that meter adjustments for higher voltage levels are subject to Rider C, while primary voltage levels have no meter adjustment.
MINIMUM CHARGE This Schedule is subject to a minimum monthly charge equal to the sum of the Customer Charge, the product of the Demand Charge and the monthly billing demand, and all applicable adjustments.
AI summary The document defines the minimum monthly charge for customers, specifying that it is calculated as the sum of the Customer Charge, the product of the Demand Charge and the monthly billing demand, plus any applicable adjustments.
CUSTOMER-OWNED METERS Customers taking service under this schedule have the option of owning their electric service meter. Customer-owned meters shall be consistent with the Company's billing and metering systems and communication protocol...
AI summary This section outlines the regulations and conditions for customers who choose to own their own electric service meters. While customers may own the hardware, the Company retains control over meter location, maintenance, and disconnection rights. Customers are responsible for all costs associated with the meter, including initial installation, updates, and testing. The Company ensures that customer-owned meters remain compatible with its billing and communication protocols, and the customer assumes all liability for any injury or damage caused by their equipment.
The customer will receive a credit for each entire billing month in which the customer-owned meter is installed and functioning at the customer's service location. The credit shall be the following: Delivery Voltage Secondary Primary Subtr...
AI summary The text outlines the terms for a monthly metering credit provided to customers who own and maintain their own electric service meters. Credits are assigned based on the delivery voltage level, ranging from $0.98 for secondary, primary, and subtransmission systems to $4.09 for transmission systems. Customers have the right to request the Company to replace a customer-owned meter with a Company-owned meter, which will result in the customer being charged for the replacement cost and the cessation of the monthly credit.
PAYMENT Bills are due upon presentation. Any amount due and not received by mail, checkless payment plan, electronic payment plan, or at authorized payment agents of the Company within twenty (20) days of the bill preparation date shall be...
AI summary The document outlines the payment terms for utility bills, stating that payments are due upon presentation. If payments are not received via mail, checkless payment plans, electronic payment plans, or authorized agents within twenty days of the bill preparation date, a delayed payment charge of 1% will be applied. This specific charge is explicitly excluded from local consumer utility taxes.
MEASUREMENT AND DETERMINATION OF BILLING DEMAND The billing demand in KW shall be taken each month as the single highest 30-minute peak in KW as registered during the month in the on-peak period by a demand meter or indicator. The monthly...
AI summary The text outlines the methodology for measuring and determining monthly billing demand for customers. It specifies that billing demand is based on the single highest 30-minute peak in kilowatts (KW) during on-peak and off-peak periods. It establishes a floor of 60% of either the contract capacity or the highest demand from the previous 11 months. Additionally, it defines the specific timeframes for on-peak and off-peak periods, including weekend and holiday designations.
CUSTOMER-OWNED METERS (Cont'd) Customers may, at any time upon request to the Company, discontinue ownership of the electric service meter. Upon such a request, the Company will replace the Customer-owned meter with a Company-owned meter a...
AI summary The text outlines the procedures and costs associated with customers who wish to discontinue ownership of their electric service meters. Customers requesting a transition to Company-owned meters must pay the replacement costs and will lose their monthly metering credit. Specific cost-sharing rules apply for customers moving to different schedules: those moving to another customer-owned meter schedule only pay for required changes, while those moving to a Company-owned meter schedule bear the full replacement cost.
PAYMENT Bills are due upon presentation. Any amount due and not received by mail, checkless payment plan, electronic payment plan, or at authorized payment agents of the Company within twenty (20) days of the bill preparation date shall be...
AI summary The document outlines the payment terms for customer bills, stating they are due upon presentation. It specifies that any outstanding balance not received via mail, checkless payment plan, electronic payment plan, or authorized payment agents within twenty days of the bill preparation date will incur a delayed payment charge of 1% per month. This charge is explicitly excluded from local consumer utility taxes.
MEASUREMENT AND DETERMINATION OF BILLING DEMAND The billing demand in KW shall be taken each month as the single highest 30-minute peak in KW as registered during the month in the on-peak period by a demand meter or indicator. The monthly...
AI summary This section outlines the methodology for measuring and determining monthly billing demand for customers. It specifies that on-peak and off-peak billing demands are based on the single highest 30-minute peak recorded during their respective periods. A floor of 60% is established for these demands based on either contract capacity or the highest demand from the previous 11 months. It also defines reactive demand, rounding rules, and the specific time windows for on-peak and off-peak periods, including holiday designations.
METERED VOLTAGE ADJUSTMENT The rates set forth in this Schedule are based upon the delivery and measurement of energy at the same voltage. When the measurement of energy occurs at a voltage different than the delivery voltage, the measurem...
AI summary This text outlines the procedures for metered voltage adjustments when energy is measured at a different voltage than the delivery voltage. The Company reserves the right to compensate for these differences using loss compensating equipment, formulas, or specific multipliers. Specifically, measurements at the low-side of customer-owned transformers are multiplied by 1.01, while measurements at the high-side of Company-owned transformers are multiplied by 0.98 to ensure accurate billing of KWH, KW, and KVAR.
(O) PAYMENT Bills are due upon receipt. Any amount due and not received by mail, checkless payment plan, electronic payment plan, or at authorized payment agents of the Company by the "Last Pay Date" shown on the bill shall be subject to a...
AI summary The document specifies the payment terms for utility bills, stating they are due upon receipt. It establishes a 1% delayed payment charge for any balance not received by the 'Last Pay Date' through approved payment methods (mail, checkless, electronic, or authorized agents). Notably, this delayed payment charge does not apply to local consumer utility taxes.
MEASUREMENT AND DETERMINATION OF DEMAND AND ENERGY The billing demand in KW shall be taken each month as the single highest 30-minute peak in KW as registered during the month in the on-peak period by a demand meter or indicator. The month...
AI summary The document specifies the methodology for measuring and determining monthly billing demand in kilowatts (KW). Billing demand is defined as the single highest 30-minute peak recorded during the on-peak period. Additionally, it establishes a floor for monthly billing demand, stating it cannot be less than 60% of the greater value between the customer's contract capacity or their highest previously established monthly billing demand from the preceding 11 months.
MEASUREMENT AND DETERMINATION OF DEMAND AND ENERGY (Cont'd) The off-peak excess demand shall be the amount by which the demand created during the off-peak period exceeds the monthly billing demand. The reactive demand in KV AR shall be tak...
AI summary The text defines the technical methodologies for measuring and determining electricity demand and energy for billing purposes. It specifies how to calculate off-peak excess demand, establishes that reactive demand is based on the highest 30-minute peak in KV AR per month, and mandates rounding billing demands to the nearest whole KW and KV AR. Additionally, it defines the specific hours and days constituting on-peak and off-peak billing periods, including designated holidays.
METERED VOLTAGE ADJUSTMENT The rates set forth in this Schedule are based upon delivery and measurement of energy at the same voltage. When the measurement of energy occurs at a voltage different than the delivery voltage, the measurement...
AI summary The document outlines the procedure for handling energy measurements taken at voltages different from the delivery voltage. It specifies that the Company will compensate for these differences to the delivery voltage using either Joss compensating equipment or specific multipliers. For instances where multipliers are applied, the text defines the exact factors: a 1.01 multiplier for measurements taken at the low-side of a customer-owned transformer and a 0.98 multiplier for measurements taken at the high-side of a Company-owned transformer.
Facilities kW The Facilities kW shall be determined by a comparison of the Actual kW in the current billing period and the Actual kW as recorded in each of the previous eleven (11) billing periods. If there are less than eleven (11) previo...
AI summary The document defines the methodology for determining 'Facilities kW' for billing purposes. The Facilities kW is calculated by comparing the Actual kW of the current billing period against the highest Actual kW recorded in the preceding eleven billing periods. The value is capped at a minimum of 500 kW. It also provides a calculation example showing how the Facilities kW Charge is derived based on the resulting kW value.
Previous Summer Peak kW The Previous Summer Peak kW shall be the greater of: the maximum fifteen (15) minute "on-peak" demand measured during the most recent billing months of July, August, and September or 2) fifty percent (50%) of the ma...
AI summary The text defines the methodology for determining the 'Previous Summer Peak kW' value, which is used to establish billing parameters for the period from October through May. The value is calculated as the greater of the maximum 15-minute 'on-peak' demand during July, August, and September, or 50% of the maximum 15-minute 'off-peak' demand during those same months. A minimum floor of 500 kW is established for this metric.
BILLING PERIODS Summer Winter Weekdays (except holidays) (1) On-peak 10 a.m 10 p.m. 15 his hoox 5 Off-peak 10 p.m 10 a.m. = 60 km, 10 p.m 7 a.m. = 75 ms/week Weekends, holidays per week $ (00.00) (2000) Off-peak all hours = 36% all hours =...
AI summary The document outlines the specific billing periods and time-of-day (TOD) structures for electricity rates, categorized into Summer and Winter periods. It defines 'On-peak' and 'Off-peak' hours for weekdays, weekends, and holidays, noting that times are based on Central Standard Time or Central Daylight Savings Time. The schedule specifies various time windows, such as 10 a.m. to 10 p.m. for certain summer periods and specific hourly allocations for winter weekday and weekend usage.
METERING LOSS ADJUSTMENT Where service is metered at a voltage level other than secondary, an adjustment to both the kilowatt-hour (kWh) and kilowatt (kW) readings will be made as follows: - 1. Service Metered at Primary Voltage Where serv...
AI summary The document outlines the specific rules for the Metering Loss Adjustment, which applies to customers served at secondary voltage. It specifies fixed percentage reductions for metered kilowatt-hour (kWh) and kilowatt (kW) readings based on the voltage level of the service point: 1.5% for primary voltage (12 kV circuit feeder), 2.5% for substation voltage (4 kV or 12 kV), and 3% for transmission voltage (34 kV and above). Customers must bear all costs for meter relocation to qualify for these adjustments, and the adjustment is unavailable for new installations after March 1, 2006.
WEB USAGE SERVICE Issued by: Gary Clemens, Regulatory Services Customers served under this LPS rate schedule are eligible for basic monthly web usage service which includes web access to their usage for fifteen (15) minute interval data wh...
AI summary The document specifies that customers served under the Large Power Service (LPS) rate schedule are entitled to a basic monthly web usage service. This service provides customers with access to their electricity usage data at fifteen-minute intervals, which is updated on a monthly basis.
ANNUAL MINIMUM: $511,470 Any annual minimum deficiency will be determined during the April billing cycle for the previous 12-month period. For a customer who has taken service on this schedule for less than 12 months, the annual minimum wi...
AI summary The document establishes an annual minimum charge of $511,470 for a specific service schedule. It specifies that any annual minimum deficiency will be calculated during the April billing cycle for the preceding 12-month period. Additionally, for customers who have been on this service schedule for less than a full year, the annual minimum will be prorated based on their actual months of service.
Measurements of Maximum Load and Energy Maximum Load shall be measured by suitable recording instruments provided by Company. The Metered Maximum Load shall be the customer's highest average thirty-minute kW load in the billing period. Whe...
AI summary The text establishes the technical requirements for measuring a customer's Maximum Load and energy usage. It defines Metered Maximum Load as the highest average thirty-minute kW load during a billing period. It also specifies that for locations with multiple meters (at 480 Volts or lower), the Maximum Loads for each meter must be aggregated to determine the total monthly Maximum Load. All measurements are to be conducted using instruments provided by the Company.
Metering Adjustments At the option of the Company, service hereunder may be metered at voltage levels different from delivered voltages. In the event metered voltages exceed delivered voltages, before computing the charges, the actual meas...
AI summary The document outlines the procedure for metering adjustments when the voltage level used for metering differs from the actual delivered voltage. It specifies that if the metered voltage exceeds the delivered voltage, the measurements for energy, kVAr, and Billing Maximum Load must be decreased by 1% before calculating charges. Conversely, if the delivered voltage exceeds the metered voltage, these measurements must be increased by 1% before charges are computed.
Billing Maximum Load The Billing Maximum Load will equal the Metered Maximum Load in kW adjusted for metering adjustments, if applicable. In no event shall the Billing Maximum Load be less than 25 kW. Billing of kVAr For Customers who have...
AI summary The text defines the methodology for determining the Billing Maximum Load, which is based on the Metered Maximum Load in kW, subject to metering adjustments, with a minimum floor of 25 kW. It also specifies the calculation methods for billed kVAr demand based on whether a customer has pulse metering. For pulse metering customers, calculations use peak 30-minute kW demand and coincident power factor; for others, average monthly power factor is used.
Special Terms and Conditions (Contd.) - 2. All wiring, pole lines, wires, and other electrical equipment and apparatus located beyond point of connection of Customer's service lines with the lines of Company are considered the distribution...
AI summary This section outlines special terms and conditions regarding the distribution of electrical services. It clarifies that equipment beyond the point of connection is the customer's responsibility, except for certain metering equipment. It addresses the company's policy on providing transformations for primary service, noting that excess facilities charges apply for unusual requests. Additionally, it defines metering requirements for single locations and establishes a 'Maintenance Period Provision' allowing customers to receive prorated maximum load charges during scheduled maintenance, subject to a $500.00 fee.
BILLING CYCLE KWH SALES FOR THE COMPANY'S RETAIL CUSTOMERS BY RATE GROUP BASED ON THE TWELVE-MONTH PERIOD ENDED DECEMBER 31,2005 Line No. Rate Groups Billing Cycle KWH Sales (A) Sum Of Monthly Non-Coincident Peak Demands (B) Line No. Rate...
AI summary The document provides a detailed breakdown of billing cycle kilowatt-hour (KWH) sales for the Company's retail customers, categorized by rate group. The data covers a twelve-month period ending December 31, 2005. It lists specific sales figures for various groups, including Residential Service (RS), Commercial Service (CS), High Load Fuel (HLF), and others, totaling 26,705,571,290 KWH for all retail customers. It also includes monthly non-coincident peak demands for specific rate groups.
BILLING CYCLE KWH SALES FOR THE COMPANY'S RETAIL CUSTOMERS BY RATE GROUP FOR THE TWELVE MONTHS ENDED DECEMBER 31,2004 Line No. Retail Rate Group (Note) Adjusted Billing Cycle KWH Sales (Note) Line No. Rate RS 8,373,784,599 2 Rates CS and F...
AI summary The document provides a table detailing the adjusted billing cycle kilowatt-hour (kWh) sales for the company's retail customers, categorized by rate group, for the twelve-month period ending December 31, 2004. It specifies that the total retail sales amount to 13,086,816,280 kWh. A specific note clarifies that these figures exclude commercial and industrial customers with an annual peak demand exceeding 500 kW from the prior calendar year.
DEFINITION OF ''MONTH'' The term "month" as used in this Schedule means the period intervening between meter readings for the purposes of monthly billings. Readings are taken once a month at intervals of approximately thirty (30) days. Sum...
AI summary The text provides formal definitions for the terms 'month', 'summer months', and 'winter months' as used in the billing schedule. A 'month' is defined as the period between meter readings, typically occurring every 30 days. Additionally, it establishes the specific date ranges for seasonal rates: summer months are defined as June 1 through September 30, while winter months are defined as October 1 through May 31.
DETERMINATION OF BILLING DEMAND - A. The On-Peak Billing Demand each month shall be the largest of the following: - I. The maximum integrated thirty-minute demand during the applicable summer or winter on-peak period during the month for w...
AI summary The document establishes the methodology for determining 'On-Peak Billing Demand' for customers. It specifies that the monthly billing demand is calculated as the highest value among three criteria: the maximum integrated thirty-minute demand during applicable seasonal on-peak periods, 50% of the Contract Demand (or 50% of the On-Peak Contract Demand if specified), or a fixed base of 15 kilowatts (KW).
B. Economy Demand To determine the Economy Demand, the larger of - I. The maximum integrated thirty-minute demand during the month for which the bill is rendered; or - 2. 50% of the Contract Demand shall be compared to the On-Peak Billing...
AI summary The text defines the methodology for calculating 'Economy Demand' for billing purposes. It establishes that Economy Demand is determined by identifying the larger of two values: the maximum integrated thirty-minute demand during the billing month, or 50% of the Contract Demand compared to the On-Peak Billing Demand. If the resulting figure exceeds the On-Peak Billing Demand, the difference constitutes the Economy Demand.
MINIMUM BILL The minimum bill shall be the bill calculated on the Rate above including the Basic Facilities Charge, Demand Charge and Energy Charge, but the sum of the On-Peak Demand Charge and the Economy Demand Charge shall not be less t...
AI summary The text defines the calculation of the minimum bill for customers, which is based on the Rate including the Basic Facilities Charge, Demand Charge, and Energy Charge. It specifies a floor for the sum of the On-Peak Demand Charge and the Economy Demand Charge at $1.64 per month per KW of Contract Demand. Additionally, the Company reserves the right to adjust the minimum bill based on the maximum integrated demand from the preceding twelve months if the customer's measured demand exceeds their Contract Demand.
PAYMENT Bills under the Schedule are due and payable on the date of the bill at the office of the Company. Bills are past due and delinquent on the fifteenth day after the date of the bill. If any bill is not so paid, the Company has the r...
AI summary The text outlines the payment terms for bills issued under the Schedule. Bills are due on the date of issuance at the Company's office and are considered delinquent fifteen days after the bill date. The Company reserves the right to suspend service for non-payment. Furthermore, any unpaid balance remaining after twenty-five days from the bill date will incur a one percent (1%) late payment charge, which will be applied to the subsequent month's bill.
CONTRACT PERIOD Each customer shall enter into a contract to purchase electricity from the Company for a minimum original term of one (1) year, and thereafter from year to year upon the condition that either party can terminate the contrac...
AI summary The text outlines the standard contract terms for customers purchasing electricity from the Company. It establishes a minimum original contract term of one year, with subsequent year-to-year renewals. Termination by either party requires at least 60 days' written notice following the initial term. The Company reserves the right to require longer initial terms if justified. Additionally, customers requesting early termination or amendments before the initial term expires are subject to early termination charges as defined in the Company's Service Regulations.
DEFINITION OF "MONTH" The term "month" as used in this Schedule means the period intervening between meter readings for the purposes of monthly billing. Readings are taken each month at intervals of approximately thirty (30) days. Summer m...
AI summary This section defines the term 'month' for the purpose of monthly billing, specifying that it refers to the period between meter readings, which occur approximately every 30 days. It also establishes the specific calendar periods for 'summer months' rates (June 1 to September 30) and 'winter months' rates (October 1 to May 31). Additionally, it provides specific billing month designations for customers in cycles 1-14 and 21-34.
DETERMJNA TION OF BILLING DEMAND - A. The On-Peak Billing Demand each month shall be the largest of the following: - !. The maximum integrated thirty-minute demand during the applicable summer or winter on-peak period during the month for...
AI summary The document specifies the methodology for determining the On-Peak Billing Demand for each month. It establishes that the billing demand is calculated as the largest value among three criteria: the maximum integrated thirty-minute demand during specific summer or winter on-peak periods, 50% of the Contract Demand (or On-Peak Contract Demand if specified), or a fixed floor of 15 kilowatts (kW).
B. Economy Demand To det~rmine the Economy Demand, the larger of - !. The maximum integrated thirty-minute demand during the month for which the bill is rendered; or - 2. 50% of the Contract Demand shall be compared to the On-Peak Billing...
AI summary The document outlines the methodology for determining 'Economy Demand' for billing purposes. Economy Demand is calculated by identifying the larger value between the maximum integrated thirty-minute demand for the billing month and 50% of the Contract Demand compared to the On-Peak Billing Demand. If the result of the first calculation exceeds the On-Peak Billing Demand, the difference is established as the Economy Demand.
PAYMENT Bills under the Schedule are due and payable on the date of the bill at the office of the Company. Bills are past due and delinquent on the fifteenth day after the date of the bill. If any bill is not so paid, the Company has the r...
AI summary The text outlines the payment terms for bills under the Schedule, stating they are due on the bill date at the Company's office. Bills are considered delinquent on the fifteenth day after the bill date, at which point the Company reserves the right to suspend service. Furthermore, any unpaid bills remaining past the twenty-fifth day will incur a 1.5% late payment charge, which will be applied to and due with the following month's bill.
CONTRACT PERIOD Each customer shall enter into a contract to purchase electricity from the Company for a minimum original term of one (I) year, and thereafter from year to year upon the condition that either party can terminate the contrac...
AI summary The text outlines the standard contractual terms for customers purchasing electricity from the Company. It specifies a minimum original contract term of one year, with provisions for year-to-year renewal or termination by either party provided 60 days' written notice is given. The Company reserves the right to require longer terms if justified. Additionally, it establishes that customers requesting early termination or amendments before the initial term expires are subject to early termination charges as defined in the Company's Service Regulations.
N-40RIRs Attachment SEB-NSPI - 2a, pt. 4 (Large File - 19 MB)
23 passages
Billing Demand The billing demand for any month shall be the maximum demand measured during on-peak hours as hereinafter defined plus 15% of the excess of the maximum off-peak demand over such on-peak demand but in no case shall be less th...
AI summary The text defines the methodology for calculating monthly billing demand for electricity service. It establishes that billing demand is based on the maximum demand measured during on-peak hours (Monday through Saturday, 7:00 A.M. to 10:00 P.M.), plus 15% of the excess of maximum off-peak demand over on-peak demand. It also sets minimum billing demand thresholds based on the service point's establishment date, the capacity specified in the Electric Service Agreement, or 70% of the previous 12 months' highest billing demand.
TERMS OF PAYMENT Bills are due and payable on presentation. A late payment charge of 2% of the net bill will be added to each bill not paid in full within twenty (20) days from the date mailed.
AI summary The document outlines the terms of payment for customer bills, stating that they are due and payable upon presentation. It specifies a late payment penalty of 2% of the net bill, which will be applied to any bill that remains unpaid in full for more than twenty days following the date it was mailed.
APPLICABILITY This Schedule is applicable to all electric service of the same available type supplied to Customer's premises at one point of delivery through one meter.
AI summary The provided text defines the scope of applicability for a specific Schedule, stating that it applies to all electric services of the same available type delivered to a customer's premises at a single point of delivery using a single meter.
BILLING DEMANDS - I. The on-peak Billing Demand shall be the maximum demand registered or computed by or from Company's metering facilities used in the on-peak hours of the current month during any 15-minute interval. - II. The off-peak ex...
AI summary The document defines the methodology for calculating Billing Demand for electricity customers. It establishes that 'on-peak Billing Demand' is based on the maximum demand recorded during any 15-minute interval during on-peak hours in the current month. Conversely, 'off-peak excess Billing Demand' is calculated by taking the maximum demand from any 15-minute interval during off-peak hours and subtracting the on-peak Billing Demand.
POWER FACTOR ADJUSTMENT When the power factor in the current billing month is less than 85%, the monthly bill will be increased by a sum equal to $0.40 multiplied by the difference between the maximum reactive kilovolt-amperes (kV Ar) regi...
AI summary The document describes a specific billing mechanism for a power factor adjustment. If a customer's power factor falls below 85% during a billing month, an additional charge is applied. This charge is calculated by multiplying a rate of $0.40 by the difference between the maximum reactive kilovolt-amperes (kV Ar) recorded during a 15-minute interval and 62% of the maximum kW demand registered for that month.
PAYMENTS Bills are due when rendered and are payable within 15 days from the date of the bill. If any bill is not so paid, Company has the right to suspend service in accordance with its Service Regulations. In addition, any bill not paid...
AI summary The text outlines the payment terms for customer bills, specifying that payments are due within 15 days of the billing date. It establishes the Company's right to suspend service for non-payment in accordance with Service Regulations. Furthermore, it details a late payment penalty of 1% per month for any balance remaining unpaid after 25 days from the bill date, as per Rule R12-9 of the Rules and Regulations of the North Carolina Utilities Commission.
2. CURTAILABLE DEMANDS Curtailable Demands shall be the kW of demand registered or computed by or from Company's metering facilities during each 15-minute interval in the current billing month less the Firm Demand but not less than zero.
AI summary The document provides a technical definition for 'Curtailable Demands' within a utility tariff or regulatory framework. It defines these demands as the kilowatt (kW) of demand registered or computed by the Company's metering facilities during each 15-minute interval of the current billing month, excluding the Firm Demand, with a minimum floor of zero.
MINIMUM NUMBER OF KILOWATT-HOURS The minimum number of kilowatt-hours attributable to all Curtailable Demands shall not be less than 50 kWh per kW of the maximum Curtailable Demand during the current billing month. For use with the Large G...
AI summary The document specifies the minimum kilowatt-hour (kWh) requirements for Curtailable Demands, establishing a floor of 50 kWh per kW of the maximum Curtailable Demand for the current billing month. It further clarifies that for the Large General Service (Time-of-Use) Schedule, any kilowatt-hours billed under this provision exceeding the registered amount will be charged at the off-peak kilowatt-hour rate.
APPLICABILITY This Schedule is applicable to all electric service of the same available type supplied to Customer's premises at one point of delivery through one meter.
AI summary The document specifies the scope of applicability for the Schedule, stating that it applies to all electric services of the same type provided to a customer's premises at a single point of delivery using a single meter.
BILLING DEMANDS - I. The on-peak Billing Demand shall be the maximum demand registered or computed by or from Company's metering facilities used in the on-peak hours of the current month during any 15-minute interval. - II. The off-peak ex...
AI summary The text defines the methodology for calculating 'Billing Demand' under the LGS-TOU-7 Tariff. It specifies that 'on-peak Billing Demand' is determined by the maximum demand recorded during any 15-minute interval during on-peak hours in a given month. Additionally, it defines 'off-peak excess Billing Demand' as the maximum demand registered during any 15-minute interval in off-peak hours that exceeds the established on-peak Billing Demand.
PAYMENTS Bills are due when rendered and are payable within 15 days from the date of the bill. If any bill is not so paid, the Company has the right to suspend service in accordance with its Service Regulations. In addition, effective on a...
AI summary The text outlines the payment terms for utility bills, stating they are due within 15 days of the billing date. It specifies that the Company reserves the right to suspend service for non-payment in accordance with its Service Regulations. Furthermore, it notes a specific penalty for late payments, where bills unpaid after 25 days are subject to a monthly late charge of 1%, as per South Carolina Public Service Commission rules.
2. CURT AILABLE DEMANDS Curtailable Demands shall be the kW of demand registered or computed by or from Company's metering facilities during each IS-minute interval in the current billing month Jess the Firm Demand but not less than zero.
AI summary The document provides a technical definition for 'Curtailable Demands' within the context of the utility's billing and metering framework. It specifies that Curtailable Demands are measured as the kilowatts (kW) of demand registered or computed via the Company's metering facilities during each 15-minute interval of the current billing month. These values are capped at the Firm Demand and cannot be less than zero.
APPLICABLE: This Schedule is applicable to electric service loads which have exceeded 999 kW in more than one month of any consecutive 18-month period. This schedule will remain applicable until Customer fails to exceed 999 kW for a period...
AI summary The text defines the applicability criteria for a specific electric service schedule, targeting loads exceeding 999 kW for more than one month within a consecutive 18-month period. It specifies that this classification remains until the customer maintains a load below 999 kW for 36 consecutive months. Additionally, it mandates separate metering for multiple delivery points or voltage classifications and requires special contracts for intermittent, fluctuating, or seasonally disconnected loads. Partial requirements for loads of 1,000 kW and over are governed by Schedule 47T.
MONTHLY BILLING: The Monthly Billing shall be the sum of the Basic, Demand, Energy, and Reactive Power Charges; plus applicable Metering and Delivery Adjustments. All Monthly Billings shall be adjusted in accordance with Schedules 91, 98 a...
AI summary The text outlines the components of the Monthly Billing for customers, which is calculated as the sum of Basic, Demand, Energy, and Reactive Power Charges, plus applicable Metering and Delivery Adjustments. It specifies that adjustments must follow Schedules 91, 98, and 191. Additionally, it defines the Basic Charge structure based on Load Size, providing different rates for loads 3,000 kW or less versus those exceeding 3,000 kW, using a 12-month rolling average of the two greatest non-zero monthly demands.
ON-PEAK PERIOD BILLING DEMAND: The On-Peak Billing Demand shall be the greater of: - (a) The measured On-Peak Period kW shown by or computed from the readings of Company's demand meter for the 15-minute period of greatest deliveries to Cus...
AI summary The text defines the methodology for determining the On-Peak Billing Demand for customers. It specifies that the demand is calculated as the greater of two values: the measured On-Peak Period kW recorded during the 15-minute period of highest delivery for the billing month (rounded to the nearest kW), or a fixed minimum of 500 kW.
TERM OF CONTRACT: Company may require the Customer to sign a written contract which shall have a term of not less than one year.
AI summary The document specifies a contractual requirement regarding the term of service agreements between the Company and its customers. It states that the Company may require customers to enter into a written contract with a minimum duration of one year.
Monthly Billing The sum of the Basic, Demand, Energy and Reactive Power Charges. All Monthly Billings shall be adjusted in accordance with Schedule 94.
AI summary The document defines the composition of Monthly Billing, which consists of the sum of Basic, Demand, Energy, and Reactive Power Charges. It further specifies that all Monthly Billings are subject to adjustments as outlined in Schedule 94.
On-Peak Period Billing Demand The On-Peak Period Billing Demand shall be the greater of: - 1. The measured On-Peak Period kW shown by or computed from the readings of Company's Demand meter for the 15-minute period of Customer's greatest u...
AI summary The text defines the methodology for determining the 'On-Peak Period Billing Demand' for customers. It establishes that the billing demand is calculated as the greater of two values: the actual measured On-Peak Period kW recorded by the Company's Demand meter during the customer's highest usage period within a billing month (rounded to the nearest whole kW), or a fixed floor of 500 kW.
Force Majeure The Company shall not be subject to any liability or damages for inability to provide service, and the Customer shall not be subject to any liability or damage for such inability to receive service, to the extent that such in...
AI summary This section of the tariff defines the 'Force Majeure' provisions for the Large General Service Transmission Delivery (Time of Use - 1,000 KW and Over) schedule. It stipulates that neither the Company nor the Customer shall be liable for damages or service failures caused by events beyond their control as defined in Rule 4, Part II, Section C. During such events, minimum Billing Demands are waived, though specific term minimum guarantees for special facilities extension costs may still apply. The party claiming Force Majeure is required to make diligent efforts to remedy the situation.
Term of Contract Company may require the Customer to sign a written contract with a minimum term of one year.
AI summary The document specifies the contractual requirements between the Company and the Customer, stating that the Company may require the Customer to enter into a written agreement with a minimum duration of one year.
Monthly Billing All charges and provisions of the applicable rate schedule will be applied in determining a Customer's bill except that the Customer's total electric bill will be increased or decreased by an amount equal to the product of...
AI summary The document outlines the methodology for calculating a customer's monthly electric bill. It specifies that all charges and provisions of the applicable rate schedule are applied, with specific adjustments made based on the product of kilowatt demand and a set dollar per kilowatt rate, as well as kilowatt-hours of use multiplied by a cents per kilowatt-hour rate.
PAYMENT TERMS All bills are net and payable when rendered.
AI summary The document specifies the payment terms for utility billing, stating that all bills are net and must be paid upon issuance.
Billing Month Exposure Hours Available Days Exclusions November -April 6:00a.m 12:00 p.m. Monday- Friday excluding holidays • May - October 1 :DO p.m9:00p.m. Monday- Friday excluding holidays • 'Holidays are: New Year's Day, Memorial Day,...
AI summary The text provides a schedule for 'Exposure Hours' and 'Available Days' categorized by billing months. From November to April, exposure hours are scheduled from 6:00 a.m. to 12:00 p.m. on weekdays. From May to October, the hours shift to 1:00 p.m. to 9:00 p.m. on weekdays. The schedule explicitly excludes specific holidays, including New Year's Day, Memorial Day, Independence Day, Labor Day, Thanksgiving Day, and Christmas Day.
N-40RIRs Attachment SEB-NSPI - 2a, pt. 2 (Large File - 15 MB)
26 passages
DETERMINATION OF DEMAND Maximum demand will be defined as the highest measured thirty (30) minute average kilowatt load determined by measurement. The measured demand will be adjusted for billing when the metering adjustment clause is appl...
AI summary The text defines the methodology for determining 'Maximum demand' for billing purposes. It establishes that demand is based on the highest 30-minute average kilowatt load, subject to adjustments from the metering adjustment clause. Furthermore, it sets a floor for billing demand, ensuring it is at least 75% of the highest on-peak demand from the previous May through October period (within a 12-month window) or the minimum contract capacity, whichever is greater, unless specific 1/2 on-peak - 1/2 off-peak provisions are invoked.
established during the on-peak period, the demand used for billing will be 1/2 the on-peak period demand plus 1/2 the off-peak period demand. On-peak period shall be from 10:00 A.M. to 8:00 P.M. Mountain Standard time for weekdays of Monda...
AI summary The text defines the methodology for calculating demand used for billing during specific periods. It establishes that the billing demand is calculated as an average of 50% of the on-peak period demand and 50% of the off-peak period demand. It further specifies the on-peak period as 10:00 A.M. to 8:00 P.M. Mountain Standard time on weekdays (Monday through Friday), with all other hours designated as off-peak.
RATING PERIOD SELECTION OPTION Upon written request by the Customer and approval by the Company, a customer may shift his 10-hour peak period for billing purposes by two (2) hours around the normally defined on-peak period. The Customer ma...
AI summary The document outlines a 'Rating Period Selection Option' allowing customers to request a shift in their 10-hour peak period for billing purposes. With written request and Company approval, customers can move the peak period by up to two hours in either direction from the normally defined on-peak period. This option is limited to two exercises per twelve-month billing period.
METERING ADJUSTMENT The Company may, at its option, meter the customer's electrical usage on the low voltage side of customer's substation transformer, in which case the metered quantities will be increased by a percentage which will be ba...
AI summary The Company describes its policy regarding metering adjustments for customers with substation transformers. It reserves the option to meter electrical usage on the low voltage side of the customer's substation transformer. If this option is exercised, the metered quantities will be adjusted upward by a percentage derived from calculated transformer losses.
TERMS OF PAYMENT The due date of the bill for utility service shall not be less than sixteen (16) days after issuance. A bill becomes delinquent if not received at the Company by the due date.
AI summary The document specifies the terms of payment for utility services, establishing that customers must have at least sixteen days from the date of bill issuance to make a payment. It further defines a bill as delinquent if the payment is not received by the Company by the specified due date.
DETERMINATION OF DEMAND AND ENERGY Maximum demand will consist of both firm and interruptible demand, and will be defined as the highest thirty (30) minute average kilowatt load determined by measurement. The measured demand will be adjust...
AI summary The document outlines the methodology for determining and billing maximum demand and energy for industrial customers under a power service contract. It defines maximum demand as the highest 30-minute average kilowatt load, adjusted for metering. It establishes specific rules for calculating 'Total Billing Demand' based on on-peak (10:00 A.M. to 8:00 P.M. MST, weekdays) and off-peak periods. Furthermore, it differentiates between Firm and Interruptible Power/Energy for billing purposes, ensuring that Firm Power Billing Demand does not fall below the Minimum Firm Contract Capacity.
RATING PERIOD SELECTION OPTION Upon written request by the Customer and approval by EPEC, Customer may shift his 10-hour peak period for billing purposes by two (2) hours around the normally defined on-peak period. Customer may exercise th...
AI summary The text outlines a provision allowing customers to request a shift in their 10-hour peak period for billing purposes. With written request and approval from EPEC, customers can move the peak period by up to two hours in either direction from the standard on-peak period. This option is limited to two instances within a single twelve-month billing cycle.
CONTRACT FOR SERVICE A Contract for Power Service ("Contract") must be executed between EPEC and the Customer prior to taking service under this rate schedule. The Contract shall establish the amount of the Customer's demand that shall be...
AI summary The document outlines the requirements for a Contract for Power Service between Eastern Power Corporation (EPEC) and a customer. It stipulates that a contract must be executed before service begins to define firm versus interruptible demand. The agreement establishes a three-year initial term with automatic annual renewals, requiring one year's notice for cancellation. Furthermore, the contract's specified firm power demand and minimum firm contract capacity take precedence over any conflicting terms in previous agreements.
NON-COMPLIANCE Customer understands that service under this rate is contingent upon Customers' complete and timely compliance with EPEC's requests for interruption. If, at any time, Customer fails in whole or in part to implement and maint...
AI summary The text outlines the non-compliance penalties for customers enrolled in EPEC's Interruptible Power Service. Customers must comply with load reduction requests or face damages equal to 20 percent of their current month's bill for each day of non-compliance. Repeated violations (three within 12 months) allow EPEC to terminate the service immediately. However, customers are exempt from interruption if aggregate limits are exceeded, and EPEC provides a 12-month grace period for reductions reaching at least 90% of the request.
The Fixed Fuel Factors recognize loss adjustments due to different voltage levels of service: Energy Loss Factor Fixed Fuel Factor ($/KWH) 6.1. AVAILABILITY: This schedule is available for electric service to any General Service Customer e...
AI summary The text outlines the specific rate schedule and conditions for General Service Customers, focusing on the Fixed Fuel Factors which account for energy loss adjustments across different voltage levels. It details the monthly rate structures for summer and winter seasons, including customer charges, demand charges, and energy charges. Additionally, it specifies requirements for interval metering data retrieval and the methodology for determining billing demand based on peak integrated kilowatt demand.
- 18.6.9. Credits shall be applied to bills the month after such credits are earned. AKKANSA 45 PUBL IC SE KVICI - 00 DIVINISSION Revis Repla heet N 34 34 Issued 4/10/95 Name of C Company: THE EN PIRE DISTRI CT ELECTRIC COMPANY Kind of Se...
AI summary The document outlines the Energy Cost Recovery Rider (ECR) for the Connecticut Electric Company. It specifies that credits are applied to customer bills the month following they are earned. The rider establishes a formula to determine the Energy Cost Factor (ECF) per kilowatt-hour, based on the Energy Cost Rate (ECR). The ECR is calculated by summing fuel expenses (FE) and purchased energy expenses (PE) for a specific period, adjusted for carrying charges and other variables.
9.4.4. Minimum Function: Billing Item Customer Charge: Generation Transmission Distribu lion $344.45 Customer Service $24.43 Total $368.88 Demand Charge per kW: Highest kW established in the twelve months ending with the current month: $1....
AI summary The document specifies the minimum charges for customers under a specific rate schedule. It provides a breakdown of the total monthly charge of $368.88, which includes components for Generation, Transmission, Distribution, and Customer Service. Additionally, it defines the Demand Charge per kW as $2.21, broken down into its respective components across the same categories. The text also notes that energy cost recovery factors are applied based on energy consumed, subject to potential reductions under Rate Schedule No. 18.
9.5. DEMAND The kW or kVA, if kVA metered, as shown by or computed from the readings of the Company's demand meter, for the 15-minute period of greatest use during the month, subject to the following: 1. If kVA metered: Billing kW =Metered...
AI summary The document outlines the methodology for calculating demand charges based on the 15-minute period of greatest use during a month. It specifies conversion factors for kVA metering (multiplying by 0.9) and establishes a minimum billing threshold of 1,000 kW for on-peak demand. Additionally, it defines 'Excess Demand' as the amount by which Off-Peak Demand exceeds On-Peak Demand.
9.6. PAYMENT The monthly bill shall be computed in accordance with the Net Monthly Rate, other provisions of the rate schedule and all applicable riders. Payment shall be made in accordance with Rate Schedule No. 29, Charges Related to Cus...
AI summary This section outlines the payment requirements for commercial and industrial customers under the Large Power Service - Time-Of-Use PST rate schedule. It specifies that monthly bills are calculated based on the Net Monthly Rate, alongside other rate schedule provisions and applicable riders. Payments must be made in compliance with Rate Schedule No. 29, Charges Related to Customer Activity, paragraph 29.18.1.
41.2.2. NONFIRM ENERGY For Small General Service Customers, the monthly Nonfirm Energy shall be determined by comparing the monthly billing demand, including any modifications pursuant to Section 41 .5.6., to the recorded interval data on...
AI summary This section outlines the methodology for determining Nonfirm Energy charges for Small General Service Customers. The Nonfirm Energy amount is calculated by comparing the monthly billing demand against recorded interval data. Specifically, the billing demand is subtracted from the recorded demand on an interval-by-interval basis for the current month. The total sum for the billing period represents the Nonfirm Energy, with a provision that the value cannot be less than zero in any given interval.
41.5. BILLING PROVISIONS 41.5.1. Monthly Customer Charge:
AI summary The document section introduces the billing provisions for the proceeding, specifically beginning with the Monthly Customer Charge. It establishes the framework for how customers are billed for services provided by the utility.
(AT) Function: Generation Transmission Distribution Customer Total Billing Item Service Monthly Customer Charge additional to Customer Charge under applicable standard rate schedule: $0.00 $0.00 $77.19 $72.81 $150.00 - 41.5.2. Except as pr...
AI summary The document outlines the components of a monthly customer charge for a service, specifically identifying the distribution and customer service portions totaling $150.00. It further specifies the methodology for determining monthly on-peak and off-peak billing demand. For most customers, on-peak demand is capped at the Firm Contract Demand, while off-peak demand is based on the maximum demand registered during the current month.
SCHEDULE: "PLL-4" REVISION 3 of 4 With Bills Rendered for the Billing Month of January, 2006 Original 3.14 DETERMINATION OF REACTIVE DEMAND:
AI summary The document is a schedule (PLL-4) from a regulatory proceeding that specifies the billing parameters for the month of January 2006. It identifies the status of bills as rendered and introduces a section regarding the determination of reactive demand, which is a component of electrical power system measurement and billing.
DETERMINATION OF BILLING DEMAND: The Billing Demand shall be based on the highest 30-minute kW measurement during the current month and the preceding eleven (11) months. For the billing months of June through September, the Billing Demand...
AI summary The text defines the methodology for determining Billing Demand for customers. It establishes that Billing Demand is generally based on the highest 30-minute kW measurement over a 12-month period. Specific rules are provided for summer months (June through September) and winter months (October through May), involving percentages of historical peak demands. Additionally, it sets a floor for Billing Demand, ensuring it is never less than the contract minimum, 50% of the total contract capacity, or 500 kW.
Construction Service Construction power shall be considered as a part of permanent service and will be provided in accordance with the Applicability section of this schedule. The Company will obtain a payment in advance for each metering p...
AI summary The document specifies that construction power is categorized as part of permanent service and must be provided according to the schedule's Applicability section. It further mandates that the Company must collect advance payment for each metering point to be served, with the payment amount based on current files held by the Georgia Public Service Commission.
SCHEDULE: "PLL-4" A of ABI Mith Pille F 2 and ared for the Billing M anth of language 20 Original 2 11 4 OI 4 VVILLI DIIIS Velideled 101 The Dilling IV Julius Of January, 20 Juli Chullar 3.14 4 of 4 With Bills F Rendered for the Billing M...
AI summary The provided text is a fragmented schedule (PLL-4) containing what appears to be corrupted or incorrectly transcribed data. It includes references to billing months, dates in January 20, and various numerical values, but lacks coherent narrative content or specific regulatory arguments.
A SOUTHERN COMPANY PAGE EFFECTIVE DATE 1 of 3 With Bills Rendered for the Billing Month of March, 2 AVAILABILITY:
AI summary The provided text is a header and introductory page for a document from A Southern Company. It specifies the effective date for bills rendered for the billing month of March 2022. The content is primarily administrative and does not contain substantive arguments, data, or regulatory discussions beyond the identification of the utility and the applicable billing period.
DEMAND REDUCTION AND CREDITS: Maximum Hours/Year Energy Credit Rate Demand Credit Rate 100 1.00 $/kWh 6.25 $/kW 50 1.00 $/kWh 4.75 $/kW 25 .50 $/kWh 3.50 $/kW A monthly energy credit will be paid in each billing month which includes a redu...
AI summary The document outlines the specific credit rates and structures for demand reduction programs. It provides a tiered schedule for energy and demand credits based on the maximum hours per year achieved by participants. Energy credits are applied monthly during reduction periods, while demand credits are specifically allocated to the four summer billing months from June through September.
The customer and the Company will agree on the customer's Firm Demand Level (FDL) in kilowatts. The customer must reduce demand to the FDL or lower during all reduction periods. At the end of each billing month which includes a reduction p...
AI summary The text outlines the methodology for calculating energy and demand credits for customers participating in a demand reduction program. It specifies that customers must adhere to a Firm Demand Level (FDL) and receive credits based on the reduction of actual energy and demand below the Normal Electric Demand (NED) during specific periods, such as OPEC Peak Periods. It also establishes that the FDL must be lower than the Contract Billing Level (CBL) for customers on RTP tariffs.
SCHEDULE: "DPEC-1" PAGE EFFECTIVE DATE 2 of 3 With Bills Rendered for the Billing Month of Mar REVISION PAGE NO. Tch. 2002 Second 11 00 Z 013 Willi Dill's Nellucieu loi lile Dillili g Motili Tori Mai 101, 2002 Second 1.500 NORMAL ELECTRIC...
AI summary The provided text is a fragment of a regulatory document containing a schedule titled 'DPEC-1'. It includes a revision table and a header for 'NORMAL ELECTRIC DEMAND'. The content is largely administrative, indicating a revision to a page effective for the billing month of March. No substantive arguments or policy discussions are present in this specific snippet.
ADMINISTRATIVE CHARGE: $120.00 per month. If additional metering equipment is required, the equipment and its installation must be paid for by the customer in addition to the administrative charge.
AI summary The text specifies an administrative charge of $120.00 per month. It further clarifies that any costs associated with additional metering equipment, including the equipment itself and its installation, are the responsibility of the customer and are not included in the base administrative charge.
N-40RIRs Attachment SEB-NSPI - 2a, pt. 5 (Large File - 20 MB)
23 passages
Determination of Kilowatts of Billing Demand: The Kilowatts of Billing Demand for each month will be the average kilowatt load used by the Customer during the 15-minute period of maximum use during the twelve-month period ending with the c...
AI summary The text defines the methodology for determining the 'Kilowatts of Billing Demand' for customers. It specifies that the demand will be calculated as the average kilowatt load during the 15-minute peak usage period over the preceding twelve-month period. Additionally, it establishes a floor of 80% of the contracted load and notes that this demand is subject to the Power Factor Adjustment Clause.
PAYMENT FOR SERVICE Customers who pay within 20 days of the date of the bill will pay the net bill computed on the Net Monthly Rate. The gross bill will be payable after 20 days of the date of the bill. The gross bill will be the total net...
AI summary The document outlines the billing and payment terms for customers, establishing a tiered structure based on payment timeliness. Customers who settle their bills within 20 days of the billing date are charged the net bill calculated on the Net Monthly Rate. Conversely, payments made after the 20-day window are subject to a gross bill, which includes the total net bill plus an additional 3 percent surcharge.
TERMS AND CONDITIONS Service will be furnished under the Company's Standard Terms and Conditions.
AI summary The document specifies that services will be provided to customers in accordance with the Company's Standard Terms and Conditions.
2006 Fuel Adjustment Factors - louisiana Billing Month Transmission - 138 kV Transmission - 69 kV Primary Substation Primary Secondary per Kilowatt of Bi service is provide 69 KV or higher an Upon the request of the Customer, there will be...
AI summary The document outlines the terms and conditions for Interruptible Power Service (IPS) and specific billing policies for electric service. It details a 29-cent per kilowatt discount for customers requesting service at 69 KV or higher transmission voltage who maintain their own transformation equipment. Additionally, it specifies a 16-day payment window, a 2% late penalty, and disconnection procedures governed by the Public Utility Commission of Texas.
SCHEDULE CONSISTS OF 3 SHEET (5) SECTION TITLE RATES, CHARG ES AND FEES SHEET NUMBER 10A.02 SECTION NUMBER 4.02 EFFECTIVE DATE ALL AREAS ORIGINAL 1 APPLICABLE REVISION NUMBER - INTERRUPTIBLE F POWER SERVICE (IF (S) Continued PAYMENT FOR SE...
AI summary This document is a page from a tariff manual for the Public Utility Commission of Texas. It outlines the payment terms for Interruptible Power Service (IPS), specifying that bills are due 16 days after issuance. It establishes a 2% penalty for late payments and notes that service may be disconnected for non-payment in accordance with standard terms and conditions. The text also references a specific contract and docket number from 1991.
MILITARY BASE ADJUSTMENT FACTOR Military Base Adjustment Factor shall be effective with the first billing cycle of May 2006 and will remain in effect Wltil revised eacl). year in accordance with PURA Section 36.354. Electric service suppli...
AI summary The text defines the application and billing procedures for the Military Base Adjustment Factor, which became effective in May 2006. It specifies that the factor applies to all kilowatt-hours billed across all rate schedules, including estimated usage for unmetered accounts. The factor must be clearly identified on customer bills and is explicitly excluded from accounts eligible for the Federally Owned or Operated Military Base Discount, in accordance with PURA Section 36.354.
pany or those initiated by activation of control equipment by Company, and those resulting from the operation of underfrequency relays installed in connection with instantaneous interruptible service. - FUEL COST RECOVERY: The charge per k...
AI summary The text outlines specific rate components and billing conditions for a utility service. It defines limitations on interruptions caused by control equipment or underfrequency relays, specifies a fuel cost recovery mechanism based on a specific tariff, and establishes payment terms including late fees. Additionally, it details a power factor adjustment based on reactive demand relative to measured kW demand and describes a mechanism for adjusting bills to include various taxes and fees resulting from new or amended laws.
Reactive Demand Charges If the reactive demand (in kVAR) is lagging during the 3D-consecutive-minute period beginning or ending on a clock hour of the month in which the customer's highest metered demand occurs, there shall be added to the...
AI summary The document outlines the calculation and application of reactive demand charges for customers. It specifies that a charge of $1.46 per kVAR is applied if lagging reactive demand exceeds 33 percent of the metered demand during the 3D-consecutive-minute period of the month's highest metered demand. Additionally, a charge of $1.14 per kVAR is applied to leading reactive demand during the 3D-consecutive-minute period of the month's lowest metered demand (excluding values below 25 percent of the highest demand).
Determination of Demand The metered demand for any month shall be the highest average during any 3D-consecutive-minute period beginning or ending on a clock hour of the month of the load metered in kW, and such amount shall be used as the...
AI summary The text defines the methodology for determining metered demand for monthly billing purposes. It establishes that billing demand is based on the highest average load over a 3D-consecutive-minute period starting or ending on a clock hour. Additionally, it provides a specific tiered percentage-based calculation to ensure that the billing demand does not fall below a certain threshold relative to the higher of the current contract demand or the highest billing demand from the previous 12 months.
Single-Point Delivery The charges under this rate schedule are based upon the supply of service through a single delivery and metering point, and at a single voltage. If service is supplied to the same customer through more than one point...
AI summary The text outlines the billing and metering requirements for the Schedule DSMD rate schedule, specifying that charges are based on a single delivery and metering point at a single voltage. It mandates that if a customer receives service through multiple delivery points or at different voltages, each point and voltage must be separately metered and billed.
III. DETERMINATION OF ON-PEAK AND OFF-PEAK HOURS The following on-peak and off-peak hours are applicable to the billing of all charges stated in this schedule. - A. On-peak hours are as follows: - 1. For the period of June l through Septem...
AI summary This section defines the specific on-peak and off-peak hours applicable to the billing of charges within the schedule. On-peak hours are divided into two seasonal periods: from June 1 to September 30, they are defined as 10 a.m. to 10 p.m. on weekdays; from October 1 to May 31, they are defined as 7 a.m. to 10 p.m. on weekdays. All other hours are classified as off-peak.
V. DETERMINATION OF rkVA DEMAND The rkVA of demand billed shall be the highest average rkVA measured in any 30-minute interval during the current billing month. (Continued) Filed 12-18-03 Electric-Virginia Superseding Filing Effective For...
AI summary The document specifies the methodology for determining the rkVA (reactive kilovolt-ampere) of demand for billing purposes. It establishes that the billed amount shall be based on the highest average rkVA recorded during any 30-minute interval within the current billing month. This rule was filed by Electric-Virginia and was scheduled to supersede previous filings for usage starting in 2004.
VI. DETERMINATION OF ON-PEAK ELECTRICITY SUPPLY DEMAND The kW of demand billed under II.B.l. shall be the highest of: - A. The highest average kW measured in any 30-minute interval of the current billing month during on-peak hours. - B. Se...
AI summary This section outlines the methodology for determining the on-peak electricity supply demand in kilowatts (kW) for billing purposes. It establishes that the billed demand will be the highest value among three criteria: the highest average kW measured in a 30-minute interval during on-peak hours in the current month, 75% of the highest kW recorded during the June-September period of the preceding 11 months, or a minimum threshold of 100 kW.
IX. METER READING AND BILLING When the actual number of days between meter readings is more or Jess than 30 days, the Basic Customer Charge, the Distribution Demand Charge, the rkVA Demand Charge, the On-Peak Electricity Supply Demand Char...
AI summary The document outlines the billing methodology for periods where the interval between meter readings exceeds 30 days. It specifies that several components of the electricity rate, including the Basic Customer Charge, Distribution Demand Charge, rkVA Demand Charge, and various Electricity Supply Demand Charges, must be prorated. This is achieved by multiplying each charge by the actual number of days in the billing period and dividing by 30 to ensure accurate cost recovery for longer billing cycles.
I. APPLICABILITY This schedule is applicable on a voluntary basis to any Customer who purchases electricity in accordance with Schedule 8, or to any non-residential Customer who has a recording meter installed for billing purposes and is s...
AI summary The text defines the applicability of a specific electricity schedule, noting it is voluntary for certain customers served under various schedules (e.g., Schedule 5, 6, GS-2, GS-3, GS-4) but excludes those on Schedule SG, SG-1, or RTP. It also outlines curtailment provisions, specifying seasonal windows (Summer and Winter), time periods, and annual limits on the number of curtailments. Customers must specify 'Firm Demand' for each season, with rules for adjusting these demands and associated reimbursements.
SCHEDULE CS CURT AILABLE SERVICE (Continued) - II. NOTIFICATION, CURTAILMENT PROVISIONS , AND MONTHLY BILLING TO THE CUSTOMER (Continued) - D. When notification of requested curtailment is provided at a time other than during a potential c...
AI summary This section of Schedule CS outlines the notification, curtailment, and billing procedures for customers participating in a curtailable service. It specifies that customers must reduce load to their firm demand within 30 minutes of notification. Requirements include the customer's responsibility for dedicated telecommunication costs and a $50.00 monthly administrative charge. Additionally, it defines the payment structure for specific rate schedules, where payments are based on the difference between average demand during potential curtailment periods and the firm demand level.
Billing Year: The Billing Year is the 12 billing month period starting with the first day of the Billing Period which commences nearest to April1 51 in each year, and ending on the last day of the 12lll Billing Period thereafter.
AI summary The text provides a formal definition of the 'Billing Year' for the purposes of the proceeding. It establishes that the Billing Year is a 12-month period beginning on the first day of the Billing Period that falls closest to April 1st of each year and concluding on the final day of the subsequent 12-month Billing Period.
Billing Demand: The Demand for billing purposes shall be: - 1. the highest kV.A Demand during the High Load Hours (HLH) in the Billing Period; or · - 2. 75% ofthe highest Billing Demand for the Customer's Plant in the immediately preceding...
AI summary This section outlines the methodology for determining 'Billing Demand' for industrial or commercial customers. It establishes three primary calculation methods: the highest kV.A Demand during High Load Hours (HLH), 75% of the highest Billing Demand from the preceding November to February period, or 50% of the Contract Demand specified in the Electricity Supply Agreement, whichever is highest. It also defines High Load Hours (HLH) as 06:00 to 22:00 Monday to Saturday, excluding Statutory Holidays, and provides specific rules for new customers' initial billing periods.
Aggregation of · Customer Baseline Load: A Customer having two or more operating plants may elect to have a single aggregated CBL determined for all or any combination of its operating plants in accordance with the CBL Determination Guidel...
AI summary The document outlines the rules for aggregating Customer Baseline Loads (CBL) for customers with multiple operating plants under B.C. Hydro. It specifies that while energy charges can be based on an aggregated CBL, demand charges remain separate for each plant. It also defines energy quantity calculations under the Retail Access Program Agreement, including adjustments for energy loss. Additionally, it covers interim CBL determinations, proration rules upon service termination, and notes that rates are exclusive of certain taxes.
Billing demand 5.4 The billing demand at Rate Lis equal to the maximum power demand during the consumption period concerned, but cannot be less than the contract power, which becomes the minimum billing demand. For each overrun during an i...
AI summary The text outlines the billing demand rules for Rate Lis, stating that it is based on maximum power demand during a consumption period but is capped at a minimum of the contract power. It also specifies penalty structures for overruns during interruption periods, limiting total penalties to the amount of fixed credits paid. Furthermore, it establishes a threshold for the Distributor to terminate a commitment if penalties are incurred four times during the winter period.
Billing Demand: The greatest of: - The monthly maximum kW demand; - 90% of the maximum kVA demand; - 90% of the firm amount reserved In the contract for noncurta liable Customers or 100% of the total contracted amount for curtallable Custo...
AI summary The document outlines the methodology for determining 'Billing Demand' for industrial or commercial customers. It specifies that billing demand is calculated as the greatest value among five distinct metrics: monthly maximum kW demand, 90% of maximum kVA demand, specific percentages of contracted firm amounts based on curtailment liability (noncurta vs. curtallable), 90% of the maximum demand recorded during specific months (excluding April through November), and 90% of the lesser of the average demand from the previous calendar year or the same period excluding April through November.
The declining discounts are: Year $/kW-month Year $/kW-month 1 $3.75 4 $1.50 2 $3.00 5 $0.75 3 $2.25 644 $0.00 The declining discounts are not available for loads that get incentive credits or if the Customer is in arrears at the time of t...
AI summary The document outlines a schedule of declining discounts offered to customers, which decrease annually from $3.75/kW-month in Year 1 to $0.00/kW-month by Year 644. It specifies that these discounts are ineligible for loads that receive incentive credits or for customers who are in arrears at the time of their application.
Billing Demand The monthly billing demand shall be the monthly Recorded Demand but the billing demand shall not be less than 75% of the maximum billing demand in the preceding 11 months.
AI summary The document specifies the rules for determining monthly billing demand for customers. It establishes that the monthly billing demand is generally equal to the monthly Recorded Demand. However, it includes a floor provision stating that the billing demand cannot fall below 75% of the maximum billing demand recorded during the preceding 11-month period.
N-40RIRs Attachment SEB-NSPI - 2a, pt. 3 (Large File - 23 MB)
27 passages
Delayed Payment Charge. All bills under this schedule shall be rendered and due monthly. If not paid within 17 days after the bill is mailed, there shall be added to bills of $3 or less, 10 percent of the amount of the bill; and to bills i...
AI summary The document outlines the Delayed Payment Charge structure for customer billing. Bills are due monthly and subject to a penalty if not paid within 17 days of mailing. The penalty is tiered: bills of $3 or less incur a flat 10 percent charge, while bills exceeding $3 incur a 10 percent charge on the first $3 and a 3 percent charge on the remaining balance.
Monthly Billing Demand. The billing demands in kVA for each plant shall be taken each month as the single-highest 15-minute integrated peak in kVA, as registered at such plant during the month by a demand meter or indicator, subject to the...
AI summary The document specifies the methodology for determining monthly billing demands for electric plants. It establishes that the demand in kVA is recorded as the single-highest 15-minute integrated peak during a month, as captured by a demand meter or indicator. This measurement is subject to specific off-peak hour provisions. The text is part of a revised tariff sheet issued by John R. Sampson under the authority of the Indiana Utility Regulatory Commission.
Off-Peak Hour Provision. Demand created during the off-peak hours (as set forth below) shall be disregarded for billing purposes provided that the billing demand shall not be less than 60 percent of the maximum demand created during the bi...
AI summary The text outlines the 'Off-Peak Hour Provision' for industrial power customers, specifying that demand during off-peak hours is disregarded for billing purposes. However, it establishes a minimum billing demand floor: the bill must be at least 60 percent of the maximum monthly demand, 60 percent of the contract capacity, or 60 percent of the highest monthly billing demand from the previous 11 months. Off-peak hours are defined as any time outside of the 7 a.m. to 9 p.m. Monday through Friday on-peak period.
B. Metered Voltage The rates set forth in this tariff are based upon the delivery and measurement of energy at the same voltage, thus measurement will be made at or compensated to the delivery voltage. At the sole discretion of the Company...
AI summary The text specifies that the utility's rates are based on the delivery and measurement of energy at the same voltage. It establishes that energy measurement will occur at or be compensated to the delivery voltage. The Company reserves the right to manage this compensation through three methods: using loss-compensating equipment, applying calculation formulas for losses, or utilizing multipliers on metered readings.
TARIFF I.P. (Industrial Power) (Cont'd from Sheet No. 13.1) quantities. In such cases, the metered kWh and kVA values will be adjusted for billing purposes. If the Company elects to adjust kWh and kVA based on multipliers, the adjustment s...
AI summary The document specifies the billing adjustment methodology for Industrial Power (IP) customers when measurements are taken at different points relative to transformers. It outlines specific multipliers to be applied to metered kWh and kVA values: a 1.01 multiplier for measurements taken at the low-side of a customer-owned transformer and a 0.98 multiplier for measurements taken at the high-side of a Company-owned transformer.
Special Terms and Conditions. This tariff is subject to the Company's Terms and Conditions of Service. A customer's plant is considered as one or more buildings which are served by a single electrical distribution system provided and opera...
AI summary This section outlines the special terms and conditions for a specific electrical service tariff. It defines a 'customer's plant' as one or more buildings served by a single distribution system. It specifies that the Company reserves the right to connect circuits to different points on a customer's system if load size necessitates multi-circuit delivery. Additionally, it establishes requirements for customers seeking standby or backup service, requiring a contract for a maximum demand of at least 1,000 kVA.
Monthly Billing Demand. The billing demand in kVA for each plant shall be taken each month as the single highest 15-minute integrated peak in kVA, as registered at each plant during the month by a demand meter or indicator, subject to the...
AI summary The text specifies the methodology for determining the monthly billing demand for plants in kVA. The demand is based on the single highest 15-minute integrated peak recorded during the month by a demand meter, subject to off-peak hour provisions. However, the demand cannot fall below 60 percent of the greater of the customer's contract capacity or their highest monthly billing demand from the previous 11 months, with an absolute minimum floor of 10,000 kVA.
Off-Peak Hour Provision. Demand created during the off-peak hours (as set forth below) shall be disregarded for billing purposes provided that the billing demand shall not be less than 60 percent of the maximum demand created during the bi...
AI summary The text outlines the 'Off-Peak Hour Provision' for billing demand. It specifies that demand during off-peak hours (outside of 7 a.m. to 9 p.m., Monday through Friday) can be disregarded for billing, provided the resulting billing demand is at least 60 percent of the month's maximum demand, 60 percent of the contract capacity, or 60 percent of the highest billing demand from the previous 11 months. Additionally, a minimum monthly billing demand of 10,000 kVA is established.
E. Adjustment factors to be applied to the following billing cycle month: _ Jan nuary through March 2006 - - $0.002007/kWh charge. Ap ril through September 2006 - - $0.001651/kWh charge. Oct cober through December 2006 - - $0.001651/kWh Ch...
AI summary The document provides a schedule of adjustment factors applied to specific billing cycles for the years 2006 and 2007. It specifies kilowatt-hour (kWh) charges for three distinct periods: January through March, April through September, and October through December, with the rates varying between $0.001651/kWh and $0.002021/kWh.
ISSUED BY MARSHA P. RYAN PRESIDENT FORT WAYNE, INDIANA COMMENCING WITH THE FIRST BILLING CYCLE IN THE MONTH OF OCTOBER 2006
AI summary The document snippet is a formal issuance notice identifying Marsha P. Ryan as the President in Fort Wayne, Indiana, and specifies that the terms or actions associated with the document commence with the first billing cycle in October 2006.
SUMMER AND WINTER SEASONS: The Summer Season is four consecutive months, beginning and effective May 16 and ending September 15, inclusive. The \hintar Season is eight consecutive months, beginning and effective September 16 and ending May...
AI summary The text defines the specific date ranges for the Summer and Winter seasons used for billing purposes. The Summer Season spans four months from May 16 to September 15, while the Winter Season spans eight months from September 16 to May 15. It specifies that customer bills for meter reading periods overlapping both seasons will be prorated based on the number of days in each respective season.
FILED AUG 01 1999 April 23, 1999 DATE EFFECTIVE August 1, 1999 DATE OF ISSUE month day Year DATE EFFECTIVE. month day Year ISSUED BY J. S. Latz e President 1201 W alnut, Kansa s City, Mo. v 8/9 - 8 _ > (Rev 00 = 2 0 0 H002 _ - 661 m Form =...
AI summary This document excerpt outlines the demand and usage calculation methodologies for Large Power Service (LPS) under a schedule issued by the Kansas City Power & Light Company (KCPL). It specifies the minimum demand requirements for various voltage levels (Secondary, Primary, Substation, and Transmission) and defines the formulas for calculating Monthly Maximum Demand, Ties Demand, and Billing Demand. Additionally, it establishes the methodology for determining monthly kilowatt-hour (kWh) usage based on the Monthly Maximum Demand.
DETERMINATION OF MAXIMUM LOAD The load will be measured and will be the average KW demand delivered to the customer during the 15-minute period of maximum use during the appropriate rating period each month. The Company reserves the right...
AI summary The text defines the methodology for determining and measuring a customer's maximum load for billing purposes. It establishes that load is measured as the average KW demand during the 15-minute peak period each month. The Company maintains the option to use KVA meters, applying a 90 percent multiplier to the KVA measurement. Alternatively, if a KVA meter is not used, the Company may adjust the measured maximum KW load based on a formula that accounts for power factors below 90 percent.
PROMPT PAYMENT DISCOUNT A discount of 1.5 percent will be allowed if account is paid in full within 15 days of date of bill.
AI summary The document specifies a prompt payment discount policy, stating that customers will receive a 1.5 percent discount on their accounts if payment is received in full within 15 days of the billing date.
DETERMINATION OF DEMAND The billing demand in KW shall be taken each month as the single highest 30-minute integrated peak in KW as registered during the on-peak period by a demand meter or indicator. The monthly billing demand so establis...
AI summary The text establishes the methodology for determining monthly billing demand in KW and reactive demand in KVARS. Billing demand is defined as the single highest 30-minute integrated peak during the on-peak period, with a minimum floor based on contract capacity, historical demand, or 3,000 KW. It also defines the on-peak and off-peak billing periods, specifying the hours for weekdays, weekends, and specific legal holidays.
METERED VOLTAGE The rates set forth in this tariff are based upon the delivery and measurement of energy at the same voltage, thus measurement will be made at or compensated to the delivery voltage. At the sole discretion of the Company, s...
AI summary The document outlines the tariff rules for metered voltage, stating that energy rates are based on delivery and measurement at the same voltage. It establishes that the Company has the discretion to compensate for voltage differences using loss-compensating equipment, formulas, or specific multipliers. Specifically, it defines multipliers for measurements taken at the low-side of customer-owned transformers (1.01) and the high-side of Company-owned transformers (0.98) to adjust KWH and KW values for billing purposes.
SPECIAL TERMS AND CONDJTTONS This tariff is subject to the Company's Terms and Conditions of Service. This tariff is also available to customers having other sources of energy who desire to purchase standby or back-up service from the Comp...
AI summary This section outlines the special terms and conditions for customers seeking standby or back-up service from the Company while maintaining other energy sources. Customers must contract for a maximum demand of at least 3,000 KW, with the Company not obligated to supply excess demand. Billing for such service is based on the highest demand recorded over the current and previous two billing periods. Additionally, the Company reserves the right to connect circuits to different points on a customer's distribution system if the load size necessitates multiple circuits.
MINIMUM CHARGE The bill shall in no event be less than the Customer Charge plus the Demand Charge computed upon the billing demand for the month.
AI summary The document specifies the minimum billing requirements for customers, stating that a bill cannot fall below the sum of the Customer Charge and the Demand Charge calculated based on the billing demand for the month.
LATE PAYMENT CHARGE The bill will be rendered at the above net charges (including net minimum bills when applicable) plus an amount equivalent to 1% thereof, which amount will be deducted provided bill is paid within 15 days from date.
AI summary The document specifies the calculation for late payment charges on utility bills. A charge equivalent to 1% of the net charges (including net minimum bills, where applicable) will be applied. However, this amount will be deducted if the bill is paid within 15 days from the billing date.
EXIT OR EMERGENCY LIGHTING Where governmental code or regulation requires. a separate circuit for exit or emergency lighting, the demand and consumption of such separate circuit may be combined for billing with those of the principal power...
AI summary The text specifies the billing treatment for exit or emergency lighting circuits. It states that when governmental codes or regulations mandate a separate circuit for such lighting, the demand and consumption of that specific circuit may be combined with the principal power circuit for billing purposes.
TERMS AND CONDITIONS Service will be furnished under Company's Terms and Conditions applicable hereto. Date of Issue: July 20, 2004 Issued By Date Effective: With Service Rendered On and After July 1, 2004 Original Sheet No. 51 P.S.C. of K...
AI summary The document serves as a formal notice of the Terms and Conditions under which electrical services will be furnished by the Company. It specifies that the terms are applicable to services rendered on or after July 1, 2004, and identifies the original sheet number as 51 P.S.C. of Ky. Electric No. 6.
Value Delivery Surcredit Rider - (2) On or before the 21st of the first month of each distribution year following Year 1, the Company will file with the Commission a status report of the Surcredit. Such report shall include a statement sho...
AI summary The text outlines the administrative and billing procedures for the Value Delivery Surcredit (VDS). It requires the Company to file annual status reports comparing expected versus actual distributions and to implement a Balancing Adjustment (BA) to reconcile discrepancies. The Surcredit is applied to customer bills after electric service charges but before taxes and fees. The rider specifies that the Surcredit will terminate once the Company files for or receives an order regarding an adjustment of electric base rates.
Minimum Charge: The minimum monthly bill shall be the basic service charge, applicable energy charges, and billing demand charges for the month. Issued: February 1, 1999 Issued by: James J. Howard Vice President Effective March 1, 1999 Ori...
AI summary This document defines the composition of the minimum monthly bill for customers. It specifies that the minimum charge is calculated by summing the basic service charge, applicable energy charges, and billing demand charges for a given month. The policy was issued by James J. Howard and became effective on March 1, 1999.
LATE PAYMENT CHARGE: A late payment charge of one and one-half percent per month of the past due amount will be added to the amount of the bill where payment is not made within twenty days of the rendition of the bill.
AI summary The text specifies the policy for late payment charges, establishing that a fee of 1.5% per month will be applied to any past due amounts. This charge is triggered if a customer fails to make payment within twenty days of the bill's rendition.
BILLING DEMAND: The billing demand for any month shall be the greater of: (a) the maximum kilowatt demand which has been measured during the daytime periods between 8:00 a.m. and 8:00 p.m. (Monday through Friday during the month excluding...
AI summary The document defines the methodology for calculating the monthly billing demand for customers. It establishes that the billing demand is determined by identifying the highest value among four criteria: the maximum kilowatt demand measured during specific daytime periods (Monday through Friday, excluding US holidays), 90% of the previous eleven-month maximum demand for June through September, 50% of the previous eleven-month maximum demand for all other months, or a floor of 10,000 kilowatts.
TERM OF CONTRACT: The obligations hereunder of the customer and the Company shall commence on the date electric service is first rendered to the customer and shall continue until December 31 of that year and for an initial term of three ye...
AI summary The text outlines the contractual terms for electric service between the Company and the customer. The agreement commences on the date service is first rendered and lasts for an initial three-year term, followed by annual repeating periods. Either party may terminate the contract by providing at least one year's written notice before the end of the initial or any subsequent one-year term. The Company must provide a formal letter to the customer within thirty days of service commencement to establish the specific dates.
Large General Service, LNP/LNO , continued DEMAND: The kW as shown by or computed from the readings of the Company's demand meter for the 15-minute period of the customer's greatest use during the month, determined to the nearest kW, but n...
AI summary The text outlines the rate structure and billing provisions for Large General Service, LNP/LNO customers. It specifies how demand (kW) and reactive demand (kVAR) are measured and billed, including a power factor threshold of 89.44% for reactive demand charges. It defines seasonal periods, establishes a minimum bill calculation including various charges and credits (such as a transformer ownership credit), and details payment terms, including a 1.5 percent monthly late payment charge.
57968Amended Board Order (and attached Schedules A to C)
19 passages
Section 6 Collection of Accounts - 6.1 Disconnection of Electric Service - 6.2 Rules Governing Disconnection - 6.3 Medical Emergency - 6.4 Disputed Billing for Electric Service - 6.5 Payment Agreement - 6.6 Deposits - 6.7 Dispute Test - 6....
AI summary Section 6 outlines procedures related to the collection of accounts, including disconnection of electric service, rules governing disconnection, medical emergencies, disputed billing, payment agreements, deposits, dispute tests, and returned cheque charges.
5.1 METER READING When reasonably possible, meters shall be read bi-monthly; however, the Company may read meters on a monthly basis.
AI summary The document specifies that meters should be read bi-monthly when reasonably possible, though the Company may opt for monthly readings.
POST CARD METER READING In the event that the Company is unable to obtain meter readings, for billing purposes, during the Company's normal business hours, having exercised due diligence in the usual practice of meter reading, it may leave...
AI summary The document outlines a procedure for obtaining meter readings when the Company is unable to do so during normal business hours. A prepaid postage card is left for the customer to record the meter reading and return it to the Company.
ESTIMATED METER READING If the Company is unable to obtain a meter reading due to circumstances beyond its control, or due to the failure of the Customer to return a post card reading, then the amount of power and energy used by the Custom...
AI summary The document outlines procedures for estimating meter readings when actual readings cannot be obtained. If estimated readings occur five times consecutively, the customer must arrange for proper meter reading or face disconnection or relocation of the meter. Adjustments will be made if actual readings are later obtained.
5.2 BILLING Except for Domestic Rate Customers who are on the Residential Budget Plan or the Interim Bill Plan, the Company shall render bills on a bi-monthly basis when meters are scheduled to be read or are normally read bi-monthly and o...
AI summary The document outlines billing procedures for a utility company, specifying bi-monthly and monthly billing cycles based on meter reading schedules, methods for calculating initial and final bills, and the identification of bills based on estimated readings. The procedures were approved by the Nova Scotia Utility and Review Board in 2007.
A) BUDGET PLAN A customer may make application to the Company, at any time during the year, for the Budget Plan which has a twelve-month budget period. Customers will have individual anniversary dates based on their entrance on the Plan. A...
AI summary The Budget Plan allows customers to apply for a twelve-month billing cycle based on their average energy usage. Monthly bills are calculated using historical data or estimates if unavailable. Adjustments are made at the end of the budget period to align payments with actual usage, and the company may refuse participation based on credit history.
B) GROUP BILLING PLAN A customer may request billing under the Group Billing Plan at any time. APPROVED: NOV A SCOTIA UTILITY AND
AI summary The Group Billing Plan allows customers to request billing under this plan at any time. The plan was approved by Nova Scotia Utility.
5.3 ALTERNATIVE BILLING PLANS Under this plan the customer will be issued a group bill on Tuesday of each week (Wednesday, if Monday is a holiday). This group bill will contain all ofthat customer's accounts that were regularly billed duri...
AI summary This section outlines an alternative billing plan where customers receive a group bill every week, covering all accounts billed in the previous seven days. Payments are due on the billing date, with interest charges applied if not paid within 17 days. Disputes require payment of the undisputed portion.
PAYMENT OF ACCOUNTS Bills are due on the billing date. Service to a customer whose bill remains unpaid for a period of thirty days after the billing date is subject to disconnection for non payment. Payments on accounts in arrears shall be...
AI summary The document outlines the payment terms for customer accounts, including due dates, disconnection procedures for non-payment, payment methods, and the option for pre-authorized payment plans. It emphasizes the priority of applying payments to the most outstanding balances and the need for satisfactory payment arrangements to avoid disconnection.
AUTOMATIC PAYMENT PLAN (PAY SMART) A customer may make application to the Company at any time to be placed on the Automatic Payment Plan. This plan is available to customers with no outstanding balance. Under the Automatic Payment Plan, th...
AI summary The Automatic Payment Plan (Pay Smart) allows customers with no outstanding balance to automatically pay their bills through a designated account. The company will withdraw funds based on the due date, and customers will be removed from the plan after two insufficient fund occurrences.
BI-MONTHLY BILLS- INTEREST CHARGES Bills which are issued on a bi-monthly basis and which are not paid within thirty (30) days after the billing date shall be subject to an interest charge as set forth in the Schedule of Charges. The amoun...
AI summary The document outlines the interest charges applied to bi-monthly bills not paid within 30 days of the billing date. The amount due and the effective date of the interest charge are to be clearly shown on the bill. The text is approved by Nova Scotia Utility and.
MONTHLY BILLS INCLUDING RESIDENTIAL BUDGET PLAN- INTEREST CHARGES Bills which are issued on a monthly basis, including those rendered under the Residential Budget Plan, and which are not paid within twenty (20) days after the billing date...
AI summary The document outlines the interest charges applied to monthly bills, including those under the Residential Budget Plan, if not paid within 20 days of the billing date. The amount due and the effective date of the interest charge must be clearly shown on the bill.
5.5 BILLING ADJUSTMENTS When a customer disputes the amount of electricity consumed from the meter, the Company shall: - a) Initiate a check on the meter reading to ensure the original reading was correct and advise the customer. - b) If t...
AI summary This section outlines the process for handling customer disputes regarding electricity meter readings. The Company is required to check the meter reading, perform an 'in position' test, and, if necessary, refer the customer to Industry Canada for an independent test.
CUSTOMER UNDERBILLED Should it be necessary for the Company to make a billing adjustment as a result of a customer being underbilled, for any reason, such adjustment for the amount of electric power and energy consumed in excess of that re...
AI summary The document outlines the process for billing adjustments when a customer is underbilled, specifying that adjustments are limited to six months prior to the last meter reading unless the underbilling results from illegal or wilful interference with metering equipment, in which case the adjustment period is not limited.
CUSTOMER OVERBILLED Should it become necessary for the Company to make a billing adjustment as a result of a customer being overbilled, the following time frames for the adjustment are used to calculate the overbilling as per the Electrici...
AI summary The document outlines the procedure for billing adjustments in cases where a customer has been overbilled, referencing the Electricity and Gas Inspection Act. It mentions that Nova Scotia Utility and others have approved the procedure.
6.4 DISPUTED BILLING FOR ELECTRIC SERVICE - (1) Where a customer advises the Company that all or a portion ofhis bill or any matter relating to the provision of electric service is in dispute, the Company shall: - (a) record the date, time...
AI summary This section outlines the process for handling disputes over electric service billing. It requires the company to investigate disputes, resolve them informally, and pay undisputed arrears within five days. If unresolved, the customer may appeal to the Dispute Resolution Officer, and disconnection is prohibited for 12 days after the decision.
(2) DOMESTIC CUSTOMERS - (a) In those cases where a domestic customer does not dispute liability for the amount in arrears and the domestic customer is unable to pay the amount in arrears, the Company shall offer the customer the opportuni...
AI summary The text outlines procedures for handling domestic customers with outstanding payments. If a customer cannot pay their arrears and does not dispute liability, the company must offer a payment agreement. Written agreements are required for arrangements beyond 30 days, and disconnection notices are only issued if the customer fails to comply with the agreement or is otherwise liable.
6.6 DEPOSITS When requested by the Company, a customer shall deposit with the Company a sum equal to estimated charges for three months' service when billed bimonthly, and approximately two months' when bills are rendered monthly. This dep...
AI summary The regulation outlines deposit requirements for customers, including the amount based on billing frequency, conditions for returning deposits, and exceptions for customers receiving social assistance. The Company is also required to review deposits every two years and allow installment payments.
6.7 DISPUTE TEST Upon notice from Industry Canada, the Company will remove the meter and ship it to Industry Canada (seal intact) for testing. If the meter, when tested, is found to be accurate, the customer is responsible for any outstand...
AI summary The dispute test procedure outlines that if a meter is found accurate after testing by Industry Canada, the customer is responsible for outstanding charges and a fee as outlined in Schedule of Charges 7.1, Section 1.
57968Amended Board Order (and attached Schedules A to C)
18 passages
Section 6 Collection of Accounts - 6.1 Disconnection of Electric Service - 6.2 Rules Governing Disconnection - 6.3 Medical Emergency - 6.4 Disputed Billing for Electric Service - 6.5 Payment Agreement - 6.6 Deposits - 6.7 Dispute Test - 6....
AI summary Section 6 outlines procedures related to the collection of accounts, including disconnection of electric service, rules governing disconnection, handling of medical emergencies, disputed billing, payment agreements, deposits, dispute tests, and returned cheque charges.
Section 8 Other Services - 8.1 Mersey System - 8.1.1 Delivery and Metering - 8.1.2 Power Factor - 8.1.3 Billing - 8.1.4 Other
AI summary Section 8 discusses other services related to the Mersey System, including delivery and metering, power factor, billing, and other unspecified aspects.
3.6.4 Billing a) Customer-generators will be billed under the otherwise-applicable metered tariff schedules. APPROVED: NOV A SCOTIA UTILITY AND - b) If in a given billing period the electricity supplied to NSPI' s grid by the customergener...
AI summary This section outlines the billing procedures for customer-generators under net metering arrangements, including the banking of excess self-generation, application of energy credits, anniversary dates, and the handling of multiple facilities on the same land. NSPI is designated as the sole beneficiary of emission credits from renewable energy used in these installations.
5.1 METER READING When reasonably possible, meters shall be read bi-monthly; however, the Company may read meters on a monthly basis.
AI summary The document specifies that meters should be read bi-monthly when reasonably possible, but allows for monthly readings by the Company.
POST CARD METER READING In the event that the Company is unable to obtain meter readings, for billing purposes, during the Company's normal business hours, having exercised due diligence in the usual practice of meter reading, it may leave...
AI summary The document outlines a procedure for obtaining meter readings when the company is unable to do so during normal business hours. It allows the company to leave a prepaid postage card for the customer to record and return the meter reading.
ESTIMATED METER READING If the Company is unable to obtain a meter reading due to circumstances beyond its control, or due to the failure of the Customer to return a post card reading, then the amount of power and energy used by the Custom...
AI summary The document outlines procedures for estimated meter readings when actual readings cannot be obtained. If estimated readings occur five times consecutively, the customer must arrange for proper meter readings, or the company may disconnect service or require meter relocation. Adjustments will be made if actual readings are later obtained.
METER READING IN RURAL AREAS Where electric service is supplied to a Customer in a rural area, the Company may adopt a post card meter reading system of monthly or bi-monthly meter reading. Under such system, the Company shall supply the C...
AI summary The document outlines a postcard meter reading system for rural areas, allowing customers to record and return meter readings via prepaid postage cards. The company may consider these readings as actual meter readings under this system.
5.2 BILLING Except for Domestic Rate Customers who are on the Residential Budget Plan or the Interim Bill Plan, the Company shall render bills on a bi-monthly basis when meters are scheduled to be read or are normally read bi-monthly and o...
AI summary The document outlines the billing procedures for a utility company, specifying that bills are rendered bi-monthly or monthly depending on meter reading schedules. Bi-monthly bills use doubled monthly charges, initial and final bills are based on actual service days, and estimated readings are clearly identified. The policy was approved by the Nova Scotia Utility and Review Board in 2007.
A) BUDGET PLAN A customer may make application to the Company, at any time during the year, for the Budget Plan which has a twelve-month budget period. Customers will have individual anniversary dates based on their entrance on the Plan. A...
AI summary The Budget Plan allows customers to apply for a twelve-month billing cycle based on their average electricity usage. Monthly bills are calculated using historical usage data or estimates if unavailable. Adjustments are made at the end of the budget period to align payments with actual meter readings, and customers may pay or request refunds based on discrepancies. The company may deny or remove customers from the plan due to poor credit history.
B) GROUP BILLING PLAN A customer may request billing under the Group Billing Plan at any time. APPROVED: NOV A SCOTIA UTILITY AND
AI summary The Group Billing Plan allows customers to request billing under this plan at any time. The plan was approved by Nova Scotia Utility.
5.3 ALTERNATIVE BILLING PLANS Under this plan the customer will be issued a group bill on Tuesday of each week (Wednesday, if Monday is a holiday). This group bill will contain all ofthat customer's accounts that were regularly billed duri...
AI summary This section outlines the Alternative Billing Plan, where customers receive a weekly group bill containing all accounts billed in the previous seven days. Bills are due on the billing date, with interest charges applied if unpaid within 17 days. Disputed portions must be paid in full, with adjustments made if the dispute is resolved in the customer's favor.
PAYMENT OF ACCOUNTS Bills are due on the billing date. Service to a customer whose bill remains unpaid for a period of thirty days after the billing date is subject to disconnection for non payment. Payments on accounts in arrears shall be...
AI summary The document outlines the payment terms for customer accounts, specifying that bills are due on the billing date and that non-payment may result in disconnection. It also describes various payment methods, including payment by mail, in person, or through pre-authorized payment plans.
BI-MONTHLY BILLS- INTEREST CHARGES Bills which are issued on a bi-monthly basis and which are not paid within thirty (30) days after the billing date shall be subject to an interest charge as set forth in the Schedule of Charges. The amoun...
AI summary The document outlines the interest charges applied to bi-monthly bills not paid within 30 days of the billing date, specifying that the amount due and the effective date of the interest charge must be clearly shown on the bill. The provision was approved by Nova Scotia Utility and others.
5.5 BILLING ADJUSTMENTS When a customer disputes the amount of electricity consumed from the meter, the Company shall: - a) Initiate a check on the meter reading to ensure the original reading was correct and advise the customer. - b) If t...
AI summary The document outlines the process for handling disputes over electricity meter readings. If a customer disputes the reading, the company will first verify the original reading, then conduct an 'in position' test, and finally allow the customer to request an independent test by Industry Canada if still unsatisfied.
CUSTOMER UNDERBILLED Should it be necessary for the Company to make a billing adjustment as a result of a customer being underbilled, for any reason, such adjustment for the amount of electric power and energy consumed in excess of that re...
AI summary The document outlines the process for billing adjustments when a customer is underbilled, requiring the company to estimate the excess consumption and charge the customer. The adjustment is limited to six months prior to the last meter reading, except in cases of illegal or wilful interference with metering equipment, where the adjustment period is not limited.
CUSTOMER OVERBILLED Should it become necessary for the Company to make a billing adjustment as a result of a customer being overbilled, the following time frames for the adjustment are used to calculate the overbilling as per the Electrici...
AI summary The document discusses the process for billing adjustments when a customer is overbilled, referencing the Electricity and Gas Inspection Act. It outlines the time frames used for calculating overbilling adjustments.
6.4 DISPUTED BILLING FOR ELECTRIC SERVICE - (1) Where a customer advises the Company that all or a portion ofhis bill or any matter relating to the provision of electric service is in dispute, the Company shall: - (a) record the date, time...
AI summary This section outlines procedures for handling disputed electric bills, including investigation, resolution attempts, and the role of the Dispute Resolution Officer. If unresolved, customers may appeal to the Board, with disconnection prohibited for 12 days after the officer's decision.
6.6 DEPOSITS When requested by the Company, a customer shall deposit with the Company a sum equal to estimated charges for three months' service when billed bimonthly, and approximately two months' when bills are rendered monthly. This dep...
AI summary The section outlines the requirements for customer deposits when requested by the Company, including deposit amounts based on billing frequency, conditions for returning deposits, and exceptions for customers receiving social assistance. The Company is also required to review deposits every two years and may refuse service if a deposit is not made.