Matter: Nova Scotia Power Inc. - CI C0059783 – HYD Upper Lake Falls 2 Overhaul – $1,582,014
5 passages 1 document

Distribution Planning across all matters →

N-2NSPI (NSEB) RIR 1 to 9 - Redacted 5 passages
Broken, displaced, or unusable packing gland studs; broken or problematic packing gland; excessive water leakage (especially for O– rings or lip seals). p. p. 58
Broken, displaced, or unusable packing gland studs; broken or problematic packing gland; excessive water leakage (especially for O– rings or lip seals). Location: Wicket Gate Stem Seals Specification: General Condition of Component ITM Com...

AI summary The document describes issues with packing gland studs, glands, and seals at the Wicket Gate Stem Seals location, including broken, displaced, or unusable components and excessive water leakage, particularly from O-rings or lip seals. It also notes that a visual inspection is sufficient and there is no need to disassemble the gland.

Movement or displacement of the bushing; cavitation damage; cracked or split bushings; clearance between the bushing and the gate stem journal. p. p. 63
Movement or displacement of the bushing; cavitation damage; cracked or split bushings; clearance between the bushing and the gate stem journal. Location: Specification: Between wicket gate bushing and gate stem journal ITM Complete: Yes No...

AI summary The text describes issues related to the movement, displacement, and damage of wicket gate bushings, including cavitation damage, cracks, and clearance issues between the bushing and the gate stem journal. It also provides a table with possible ITM results and adjustments to CI.

Section 126 p. pp. 74-75
Hydropower Asset Condition Assessment ITM: Twisted, Bent or Distorted Shapes Location: Gate Stem Specification:

AI summary The document discusses the condition assessment of a hydropower asset, specifically focusing on the inspection and testing methods (ITM) related to twisted, bent, or distorted shapes located at the gate stem.

Section 128 p. pp. 75-76
Hydropower Asset Condition Assessment ITM: Twisted, Bent or Distorted Shapes Location: Leaf Body

AI summary The document discusses the condition assessment of a hydropower asset, specifically highlighting an issue with twisted, bent, or distorted shapes located in the leaf body, as identified through the Inspection and Testing Method (ITM).

CI C0059783 NSEB IR-5 Attachment 1 Page 12 of 17 REDACTED (CONFIDENTIAL INFORMATION REMOVED) p. p. 117
CI C0059783 NSEB IR-5 Attachment 1 Page 12 of 17 REDACTED (CONFIDENTIAL INFORMATION REMOVED) HYDRO UNIT CONDITION ASSESSMENT Operational Performance 1 Good 17-3

AI summary The document contains a table with information on operational performance, specifically for 'HYDRO' and 'UNIT CONDITION ASSESSMENT', with a rating of 'Good' and a reference number '17-3'. The content is redacted and marked as confidential.

Disclaimer: These summaries were generated by AI from the filings they describe. We take care to make them accurate, but errors are possible - and they aren't advice. Only the filings themselves are the record: if you're relying on something here, confirm it against the source documents or the Nova Scotia Energy Board's own record. Full disclaimer →