DEFINITIONS Base case A base case details the information on how assumed gross savings used in the tracking sheet have been established. Usually, these savings are calculated with a series of variables such as hours of operation, wattage o...
AI summary The document defines key terms related to energy efficiency program evaluation, including concepts like base case, billing calibration, distortion effects, free-ridership, gross and net energy savings, and net-to-gross ratio. These definitions are crucial for understanding how energy savings are measured and evaluated in regulatory contexts.
INTRODUCTION This document provides a summary of the 2014 evaluations conducted for the Efficiency Nova Scotia Corporation (ENSC) demand-side management (DSM) programs. Established in 2010, ENSC is an organization in charge of helping Nova...
AI summary This document summarizes the 2014 evaluations of Efficiency Nova Scotia Corporation's (ENSC) demand-side management (DSM) programs. The evaluations were conducted by Econoler, in collaboration with CRA and Equilibrium Engineering, and revealed significant energy and peak demand savings. The report also discusses the evaluation methods used for different program components.
Table 1: Types of Evaluation Conducted by Program Component or Initiative Type of Evaluation Program Component or Initiative Impact Process Market Full-scale Tracked Savings Validation Appliance Retirement - - - x Instant Savings x x x - H...
AI summary This report evaluates 17 program components and initiatives offered in 2014 by ENSC, summarizing evaluation methodology, DSM portfolio performance in terms of savings, and recommendations for improvement. It includes an in-depth analysis of individual program component performance.
1.2.4 Unitary Savings Review For all the evaluated programs where savings were established on a unitary basis, the Evaluator reviewed the savings presented in the tracking system. First, their consistency with the result of the previous ev...
AI summary The Evaluator reviewed unitary savings for programs like BER Instant Rebates and Green Heat, ensuring consistency with prior evaluations. Methods included using Technical Reference Manuals (TRMs) from other jurisdictions, product specifications, and survey data (e.g., Atlantic Quarterly Survey). Sampling popular products helped establish average properties for categories with diverse offerings.
1.2.5 Project Files Review For those programs whose savings were established based on custom calculations for each measure installed, the Evaluator reviewed savings for a sample of projects. To ensure the accuracy of the calculations used,...
AI summary The Evaluator reviewed project files for programs using custom calculations, verifying accuracy through documentation and on-site visits. Adjustments were made to equations/parameters, sometimes extrapolated to non-sampled projects. Custom Retrofit sub-components (EMIS, EBC) received only file reviews, with qualitative recommendations instead of adjustments.
1.2.6 Billing Calibration For 2014, ENSC collected actual energy consumption and demand data for the buildings which participated in Custom New Construction from 2011 to 2013 evaluations, and provided them to the Evaluator to make a compar...
AI summary ENSC collected actual energy data from 2011-2013 for Custom New Construction participants to compare with simulated figures. Seven projects were evaluated using IPMVP guidelines, but the small sample size and limited data prevented conclusive accuracy assessments of energy simulations.
2.1 Overall Targets and Results ENSC programs encompass many components, which all share the same market. For instance, the Existing Residential program includes the Home Energy Assessment, Green Heat, Low Income Homeowner, Residential Dir...
AI summary ENSC programs, including the Existing Residential program, are evaluated against overall targets set by ENSC. The mid-course targets for program components were reviewed by the DSM Advisory Group, with overall energy and demand savings targets remaining consistent with those approved by the Nova Scotia Utility and Review Board (UARB) in 2014.
Table 6: 2014 Evaluated Results, Targets and Tracked Energy Savings at the Generator 2014 Energy Savings (GWh) ENSC DSM Program DSM Component Initial Gross Savings Installed/ Adjusted Gross Savings Evaluated Installed/Adjusted Gross Saving...
AI summary Table 6 presents the 2014 energy savings results, targets, and tracked savings for various energy efficiency programs in Nova Scotia. It includes data for residential and business programs, such as appliance retirement, instant savings, home energy assessments, and business energy rebates. The table also highlights the Net-to-Gross Ratio (NTGR) and net savings for each program.
Instant Savings In 2014, Instant Savings generated 9.360 GWh in net electricity savings, and 1.479 MW in net peak demand savings. The evaluated net energy savings were found to be 38 percent lower than the corresponding tracked value, whil...
AI summary In 2014, Instant Savings achieved 9.360 GWh in net electricity savings and 1.479 MW in net peak demand savings. However, evaluated savings were 38% and 31% lower than tracked values, respectively. Adjustments to baseline wattage for LED lamps and changes in free-ridership levels contributed to the discrepancies.
Green Heat The evaluation of Green Heat demonstrated that in 2014, the program had a total of 235 participants and generated net energy savings of 1.472 GWh and net peak demand savings of 0.594 MW. The net energy savings calculated through...
AI summary The Green Heat program in 2014 had 235 participants and achieved net energy savings of 1.472 GWh and peak demand savings of 0.594 MW. However, these figures are lower than those in the tracking report due to factors like a lower NTGR, reduced unitary savings for geothermal heat pumps, and adjustments for heat pumps used as primary heating systems.
Residential Direct Install Residential Direct Install had a total of 13,945 participants in 2014, and achieved net energy and peak demand savings of 24.552 GWh and 5.721 MW respectively. In addition to the regular Residential Direct Instal...
AI summary The Residential Direct Install program achieved significant energy and peak demand savings in 2014, with additional savings from a CBSM Pilot. Evaluated savings were slightly lower than tracked values due to adjustments in unitary savings, installation rates, and free-ridership levels, which were offset by increased internal spillover effects.
LED Holiday Light Exchange In 2014, a total of 117 events were held for LED Holiday Light Exchange. The evaluation demonstrated net energy savings of 0.192 GWh and net peak demand savings of 0.414 MW resulting from the distribution of 6,34...
AI summary The LED Holiday Light Exchange in 2014 resulted in energy and peak demand savings, but the evaluated savings were lower than those tracked by ENSC due to revised assumptions on unitary savings and the inclusion of an interactive effect factor. These changes reduced the estimated net demand savings by 66%.
Home Energy Report Since its inception in 2013, a total of 93,119 participants have taken part in the paper-based component of Home Energy Report, and 10,669 participants have taken part in the web-based component. In terms of net energy s...
AI summary The Home Energy Report program, since 2013, has engaged over 100,000 participants through paper-based and web-based components, achieving significant energy savings in 2014. The paper-based component achieved 25.336 GWh of net energy savings, while the web-based component achieved 0.100 GWh. Net savings were calculated using a control group comparison for the paper-based component and self-declared data for the web-based component.
Business Energy Rebates The impact evaluation has shown that in 2014, the number of participants in BER Mail-in increased slightly compared to previous years (198 regular participants and 122 promotional rebate participants), while the sav...
AI summary The evaluation of Business Energy Rebates (BER) in 2014 showed that mail-in rebates generated 11.073 GWh of net energy savings, while instant rebates generated 13.537 GWh, a decrease from the previous year due to lower LED downlight sales. Variations between evaluated and tracked savings were influenced by adjustments in calculation methods and changes in product sales.
Custom Retrofit In 2014, the Custom Retrofit component had a total of 100 projects implemented, which was lower than the previous years. Custom Retrofit generated net energy savings of 20.292 GWh and net peak demand savings of 1.599 MW in...
AI summary In 2014, the Custom Retrofit program had 100 projects, achieving 20.292 GWh in net energy savings and 1.599 MW in peak demand savings. EBC and EMIS contributed additional energy savings but no peak demand savings. Evaluated savings were lower than tracked savings due to changes in NTGR and adjustments to gross savings.
Custom New Construction This program component saw a total of 13 projects implemented in 2014, which resulted in net energy savings of 6.656 GWh and 2.517 MW in net peak demand savings at the generator. The gross energy and peak demand sav...
AI summary The Custom New Construction program had 13 projects in 2014, achieving 6.656 GWh in energy savings and 2.517 MW in peak demand savings. The Econoler team found discrepancies between their evaluation and ENSC's tracked savings, mainly due to adjustments for a LEED project and the inclusion of a diversity factor in ENSC's calculations.
Business Energy Solutions For 2014, Business Energy Solutions had a total of 761 participants. In addition, 51 participants implemented Rental Properties and Condos Service Common Area measures in 105 separate buildings, and 42 participant...
AI summary In 2014, Business Energy Solutions had 854 participants, achieving net energy savings of 13.175 GWh and peak demand savings of 2.570 MW. Savings were evaluated for lighting, non-lighting, LED Blitz pilot, and Rental Properties and Condos Service common space measures. Differences between tracked and evaluated results were due to adjustments in parameters such as NTGR, ballast factor, heat pump operating hours, and LED lamp unitary savings.
Codes and Standards For Codes and Standards, the evaluation has estimated the impact in terms of energy and peak demand savings to be achieved by introducing new regulations into the Nova Scotia market for the products targeted by federal...
AI summary The evaluation of Codes and Standards in Nova Scotia estimates energy and peak demand savings from new regulations, including increased stringency on minimum energy performance standards (MEPS). The Evaluator modified its methodology by interviewing Natural Resources Canada and industry associations to obtain reliable market size data, leading to an estimated savings of 31.433 GWh and 5.164 MW.
2.4 Evolution of Program Component Performance In 2014, ENSC's program component portfolio achieved a total of 151.888 GWh in net energy savings and 27.077 MW in net peak demand savings at the generator. These figures represent a slight de...
AI summary ENSC's program component portfolio achieved 151.888 GWh in net energy savings and 27.077 MW in net peak demand savings in 2014, a slight decrease compared to previous years. Codes and Standards also contributed with 31.433 GWh in net energy savings and 5.164 MW in net peak demand savings.
2.6 Overall Performance In 2014, ENSC's program component portfolio achieved a total of 151.888 GWh in net energy savings and 27.077 MW in net peak demand savings at the generator. In addition to the savings generated by ENSC's DSM program...
AI summary In 2014, ENSC achieved its overall energy savings targets through a combination of successful program components and new initiatives. While some program components did not meet their individual goals, others like Custom Incentives and Energy Savings Actions made up for the shortfalls. ENSC has made significant improvements in program tracking, partner relationships, and education efforts. However, some savings calculation parameters were not updated as recommended.
3 OVERALL RECOMMENDATIONS This section presents general recommendations for the program component portfolio. These recommendations are generally considered good practices and can be applied to most ENSC program components. They are specifi...
AI summary This section outlines general recommendations for the ENSC program component portfolio, aimed at improving program documentation and data management practices across most program components.
Data-tracking and reporting is crucial for effective program management as well as for evaluation purposes. In 2010, ENSC implemented an online Demand-Side Management Data System (DSMDS) and has been working on its improvement since then....
AI summary Data-tracking and reporting are essential for managing and evaluating energy efficiency programs. ENSC implemented the DSMDS in 2010 and improved it over time, allowing for centralized tracking of projects. However, some program components still use custom tools or external data sources for tracking. The Evaluator praised ENSC's efforts and highlighted areas for improvement in data tracking systems.
4.1.1 Instant Savings The 2014 evaluation of Instant Savings demonstrated that most of the recommendations made specifically for Instant Savings in the previous evaluations were implemented. The Evaluator commends ENSC on the efforts it ma...
AI summary The 2014 evaluation of Instant Savings highlights successful implementation of prior recommendations, improvements in product range and marketing, and positive feedback from stakeholders. However, challenges remain, including inconsistent retailer engagement and inadequate in-store POP displays, which hinder program delivery.
Table 12: Recommendations for Instant Savings No. Recommendations Instant-R1. Continue monitoring the retailers' commitment to meeting POP requirements. The DA mentioned that though its interactions with retailers improved over time, chall...
AI summary The document recommends continuing to monitor retailers' adherence to Point-of-Purchase (POP) requirements, noting that while interactions with retailers have improved, challenges remain in engaging some retailers. Issues with POP installation were observed, potentially misleading salespeople and customers about product discounts.
The 2014 evaluation of Green Heat demonstrated that most of the recommendations made specifically for Green Heat in the last evaluations were implemented. The Evaluator commends ENSC on the efforts it made to improve and optimize Green Hea...
AI summary The 2014 evaluation of Green Heat noted that most recommendations from previous evaluations were implemented, with ENSC commended for improvements in marketing, outreach, and data collection. The deadline for equipment installation was extended to six months, leading to positive participant feedback. On-site visits confirmed that rebated equipment was installed and used as the primary heating source, though data accuracy in the tracking system requires improvement.
cking report contains enough information to allow carrying out the evaluation, it is recommended that further improvements be made to the accuracy of the data collected. Survey results showed that participants' satisfaction with Green Heat...
AI summary The evaluation of the Green Heat program found high participant satisfaction but noted a slight decline in participation since 2011, attributed to changes in rebate eligibility. Energy savings decreased in 2014 compared to previous years, with net savings of 1.472 GWh and peak demand savings of 0.594 MW. The evaluation considered free-ridership and used literature review data for calculations.
Table 13: Recommendations for Green Heat No. Recommendations GH-R1. Consider using an initial system efficiency other than 100 percent when the air source heat pump or the geothermal heat pump is used as the initial primary heating system....
AI summary The table suggests adjusting the efficiency assumptions for heat pumps in green heating programs. It recommends using a lower initial system efficiency than 100% for air and geothermal heat pumps, as some projects already have these systems as primary heating sources. It also proposes removing an eligibility criterion requiring participants to have a total electricity consumption of over 21,000 kWh/year before installation.
us years. This was found to be due in part to higher product removal rates by the participants, but also to entry errors made by the DAs. The Evaluator recommended that this situation be investigated. Survey results showed that word of mou...
AI summary The evaluation of the Residential Direct Install program found high participant satisfaction and effectiveness in promoting energy efficiency. Word of mouth was the main source of awareness, and participants reported positive changes in behavior, such as turning off lights and reducing water consumption. DAs noted the program's educational value but recommended improvements in marketing.
havioural change being related to turning off the lights. Other behavioural changes include increased awareness of power usage and saving energy, turning off appliances and reducing water consumption. A total of 13,945 participants partici...
AI summary The Residential Direct Install program saw a reduction in participants from 2012 to 2014, but achieved energy savings targets through increased efficiency measures like LED lighting and smart power controllers. The program also included a CBSM Pilot that encouraged reduced warm water usage for laundry, contributing additional energy savings.
Table 14: Recommendations for Residential Direct Install No. Recommendations RDI-R2. Follow up with DAs to identify the cause of entry errors. In 2014, the installation rates observed by the Evaluator during the on-site visits were general...
AI summary This recommendation highlights the need for ENSC to investigate entry errors by Delivery Agents (DAs) that led to discrepancies in installation rates observed during on-site visits in 2014, which significantly impacted the gross savings evaluation.
4.1.4 Home Energy Report Launched in 2013, Home Energy Report is an innovative program intended to promote behavioural changes towards greater energy efficiency. Since its inception, a total of 93,119 participants have taken part in the pa...
AI summary The Home Energy Report program, launched in 2013, has achieved significant energy savings, particularly through its paper-based component. While the web-based component has had limited measurable impact, the program overall has contributed 34.789 GWh in net energy savings. Evaluation shows that participants adopted some energy-efficient behaviors after participation, though the web-based component's influence was less clear.
Table 15: Recommendations for Home Energy Report No. Recommendations HER-R3. Conduct a billing analysis to compare the pre-participation electricity consumption of the treatment and control groups. Socio-demographic data were analyzed and...
AI summary The recommendations suggest conducting a billing analysis comparing electricity consumption of treatment and control groups to assess the impact of the Home Energy Report. It also recommends including the age of the home in criteria for selecting groups to ensure accurate building code representation.
packs and LED downlights) based on the distributor interviews, and applied a zero free-ridership level to other products. This resulted in an overall NTGR of 0.73 for energy savings of this component. The evaluation revealed that overall B...
AI summary The Business Energy Rebates (BER) program showed a decrease in overall energy savings from 2013 to 2014, with 24.610 GWh in 2014 compared to 34.169 GWh in 2013. This decline was largely attributed to a special event in February 2013 that led to unusually high sales of LED downlights, resulting in inflated savings claims.
No. Recommendations BER-R3. Implement recommended changes to savings calculations in a timely manner. Once again this year, the Evaluator found that not many modifications to savings calculations recommended in last year's evaluation repor...
AI summary The Evaluator recommends that ENSC implement changes to savings calculations in a timely manner, noting that many recommendations from previous years have not been implemented. This year, adjustments were made to tracked savings for peak demand and energy savings of air-source heat pumps to avoid an excessive margin of error.
The 2014 evaluation of Custom Retrofit demonstrated that most of the recommendations made in previous evaluations have been implemented. The Evaluator commends ENSC on its efforts in improving and optimizing Custom Retrofit. Among the impr...
AI summary The 2014 evaluation of the Custom Retrofit program noted that many previous recommendations had been implemented, including transferring simple lighting projects to prescriptive programs, which may have contributed to a decline in participation. The evaluation confirmed that 100 projects completed in 2014 achieved good energy savings, and the verification process was found to be thorough.
thoroughly and properly conducted. One element that explains why adjustments to peak demand savings were more significant is that the Evaluator changed some of the diversity factors estimated by ENSC. Moreover, when calculating the net ene...
AI summary The document discusses adjustments to peak demand savings, noting that changes in diversity factors by the Evaluator impacted the results. In 2014, Custom Retrofit achieved significant energy and peak demand savings, while EBC and EMIS contributed additional energy savings. Participant satisfaction with Custom Retrofit remained high, with most recommending it to others and expressing interest in future ENSC programs.
Table 18: Recommendations for Custom Retrofit No. Recommendations Custom-R1. Perform thorough M&V and document it in a complete report for every large project for which thorough M&V work is justified and required. The Evaluator has observe...
AI summary The text recommends thorough Measurement and Verification (M&V) for large energy efficiency projects, citing the need for complete reports following standard protocols like IPMVP, especially for projects receiving significant incentives. For smaller projects, a simplified summary of measurement methods and equations is suggested.
4.2.3 Custom New Construction Custom New Construction saw a total of 13 projects implemented in 2014, which represents a small decrease over the 15 projects implemented in 2013. However, the 2014 project count is higher than the number of...
AI summary In 2014, Custom New Construction had 13 projects, slightly fewer than 2013 but more than 2012, showing stable participation. The program achieved 6.656 GWh in net energy savings and 2.517 MW in peak demand savings. Site visits were used to validate and adjust savings, and adjustments were minimal, indicating most projects were implemented as submitted. No free-ridership was applied due to ENSC's new baseline approach.
Properties and Condos Service common space measures and 42 participants took part in the LED Blitz pilot, which makes for a total of 854 participants for the whole Business Energy Solutions component. The impact evaluation revealed that, w...
AI summary The Business Energy Solutions component, including the LED Blitz pilot, involved 854 participants and generated net energy savings of 13.175 GWh and peak demand savings of 2.570 MW in 2014. The evaluation considered interactive effects, installation rates, diversity factors, and freeridership and spillover effects from surveys.
Table 20: Recommendations for Business Energy Solutions No. Recommendations BES-R2. Include a light intensity analysis as part of the on-site energy assessment and provide participants with information on how to obtain replacement products...
AI summary The document recommends including a light intensity analysis in on-site energy assessments and providing participants with information on obtaining replacement lamps. This would help identify overlit areas and support participants in reducing lighting fixtures according to their needs, though additional costs and contractual agreements must be considered.
Instant Savings (continued) Natural Resources Canada, Energy Consumption of Major Household Appliances Shipped in Canada, Summary Report, Trends for 1900-2007 , December 2009, p. 43. Natural Resources Canada, Residential Sector Nova Scotia...
AI summary The text provides references to various studies and reports related to energy consumption, efficiency measures, and technologies, including heat pumps, lighting, and appliance usage, primarily focusing on data and methodologies used in energy efficiency programs.
Green Heat (Continued) Navigant Consulting, 2011 to 2019 Fuel Substitution Potential Analysis, Submitted to Nova Scotia Power Inc., February 24, 2010. Ontario Power Authority (OPA), 2011 Quasi-Prescriptive Measures and Assumptions, Release...
AI summary The document includes various references and resources related to energy efficiency programs and building regulations, including analyses and technical manuals from different provinces and organizations. These materials are cited in the context of a regulatory proceeding.
LED Holiday Light Exchange Pennsylvania Public Utility Commission, Technical Reference Manual, available at nce_manual.aspx> (Last accessed January 14, 2015). (Continued) Sampson Research, Market & Impact Evaluation of BC Hydro's Season...
AI summary The text includes references to various resources and studies on energy efficiency, including LED lighting initiatives, technical manuals, and energy-saving standards. These materials are cited in the context of regulatory proceedings and energy efficiency evaluations.
10% Example participant Spillover Algorithm (none with spillover this Calculation Algorithm Calculation Questions Answer Result SO1. Since the time that you participated in IF 1. Yes: CONTINUE Custom Retrofit, have you implemented one or I...
AI summary This table outlines a spillover algorithm used to calculate the influence of the Custom Retrofit program on participants' subsequent energy efficiency measures. It includes questions about additional measures implemented, financing or rebate requests, types of measures, and the influence of the program on decisions, with calculations for spillover savings.
Overall Executive Summary Residential Direct Install l a fu ridorchi- Ujah fu ridorchi- Augrage for oo ridorshir FR1. Did you or anyone in your household have specific plans to purcahse and install the energy-efficient products prior to ta...
AI summary The text presents a table related to a residential direct install program, including questions about pre-existing plans to purchase energy-efficient products, willingness to pay for products without the program, and factors influencing participation such as free installation, program advice, and prior experience. It also includes scoring mechanisms for these factors.
15% Spillover Algorithm Example I Participant Questions Calculation Algorithm Answer Calculation Result SO1. Since the time that you participated in RDI, have you IF 1. Yes: CONTINUE installed any additional energy-efficient products or re...
AI summary The text presents a spillover algorithm used to calculate the impact of the RDI program on participants' additional energy-efficient actions. It includes questions and calculations related to the installation of energy-efficient products, retirement of old appliances, and the influence of the RDI program on these actions. The spillover savings are calculated as 86%.
ABBREVIATIONS ARet Appliance Retirement CATI Computer-assisted Telephone Interviewing CRA Corporate Research Associates DA Delivery Agent EER Energy Efficiency Ratio ENSC Efficiency Nova Scotia Corporation NTGR Net-to-Gross Ratio UMP Unifo...
AI summary This section of the document provides a list of abbreviations and their corresponding full forms, including terms related to energy efficiency, research, and utility operations.
EXECUTIVE SUMMARY In 2014, the evaluation of Appliance Retirement (ARet) involved substantiating the tracked savings of Efficiency Nova Scotia Corporation (ENSC) with the parameters established in the 2013 evaluation, as well as the reasse...
AI summary In 2014, the evaluation of Appliance Retirement (ARet) involved verifying the tracked savings of Efficiency Nova Scotia Corporation (ENSC) against parameters from the 2013 evaluation and reassessing key parameters. The report details the validated gross and net savings for the year.
Program Component Overview ARet promotes the retirement of old household appliances, such as refrigerators, freezers and room air conditioners. ARet encourages Nova Scotians to retire their old appliances by educating them on the cost of m...
AI summary The Appliance Retirement (ARet) program encourages Nova Scotians to retire old household appliances by offering cash incentives and free pick-up services. Retired appliances are recycled, with over 95% of materials being reused. Incentives include $30 for refrigerators and freezers, and $10 for air conditioners.
Key Findings Econoler reviewed the content of the 2014 ARet tracking system. A total of 7,408 appliances were retired in 2014, including 4,745 refrigerators, 2,540 freezers and 123 air-conditioners. As for the 2013 evaluation, the Evaluato...
AI summary Econoler evaluated the 2014 ARet program, retiring 7,408 appliances and estimating energy savings using the UMP methodology. Net energy savings were 3.841 GWh and peak demand savings were 0.611 MW, with a net-to-gross ratio (NTGR) of 0.60 for refrigerators, 0.58 for freezers, and 0.55 for air-conditioners.
Table 1: Validated Gross and Net Savings at the Generator Initial Gross Savings Gross Savings with Interactive Effects NTGR equiv Net Savings Energy Savings 6.453 GWh 6.453 GWh 0.60 3.841 GWh Peak Demand Savings 1.026 MW 1.026 MW 0.60 0.61...
AI summary Table 1 presents validated gross and net savings at the generator, including energy and peak demand savings. Two appliance replacement pilot projects contributed additional savings to the ARet program, bringing total energy and peak demand savings to 3.941 GWh and 0.627 MW, respectively.
1 PROGRAM DESCRIPTION Efficiency Nova Scotia Corporation (ENSC) promotes the retirement of household appliances, such as refrigerators, freezers and room air conditioners. Designed to sway Nova Scotians into retiring their old appliances,...
AI summary Efficiency Nova Scotia Corporation (ENSC) promotes the retirement of old household appliances through the Appliance Retirement (ARet) program. Participants receive cash incentives and free pickup of eligible appliances, which are then recycled. Eligibility criteria include appliance age and condition, and rebates vary by appliance type. The program aimed to achieve significant electricity and peak demand savings in 2014.
3.1 Refrigerators This section presents the calculation for evaluating the unitary savings of the refrigerators retired in 2014.
AI summary This section outlines the methodology used to calculate the unitary savings from refrigerators retired in 2014, focusing on energy efficiency improvements and their impact.
3.1.1 Gross Unitary Savings For all refrigerators retired in 2014, ENSC uses a gross unitary savings value of 932 kWh per year, which corresponds to the average energy consumption value of retired refrigerators established during the 2013...
AI summary The document discusses the gross unitary savings value of 932 kWh per year for retired refrigerators in 2014, based on ENSC's 2013 impact evaluation. The Econoler team revised this value by updating parameters such as average energy consumption, replacement refrigerator types, and part-use factors, using data from 2014 metering and survey results.
Average Energy Consumption of Retired Refrigerators The Evaluator revised the annual energy consumption value of the retired refrigerators using the data from the 2014 metering activity. Reliable data for a total of 68 refrigerators was us...
AI summary The Evaluator updated the annual energy consumption of retired refrigerators using 2014 metering data from 68 units. The analysis accounted for different age categories and calculated average consumption per cubic foot, reflecting their proportion in the 2014 tracking sheet.
Average Energy Consumption of Replacement Refrigerators The average annual energy consumption of replacement refrigerators is used to take into account the effects of the secondary market and induced consumption. To do so, refrigerators we...
AI summary The average annual energy consumption of replacement refrigerators is calculated by dividing them into new and used categories and high and standard efficiencies. Three energy consumption levels were assigned based on the UMP methodology, with new high-efficiency refrigerators aligned with ENERGY STAR requirements and new standard-efficiency refrigerators matching used high-efficiency ones.
Table 6: Average Annual Consumption for Refrigerator Replacement Type of replacement Annual Energy Consumption Proportion New High-efficiency Refrigerator 408 kWh/year 79% Used High-efficiency Refrigerator 587 kWh/year 15% New Standard-eff...
AI summary Table 6 presents average annual energy consumption for different types of refrigerator replacements, showing that new high-efficiency refrigerators have the lowest consumption at 408 kWh/year, while used standard-efficiency refrigerators have the highest at 738 kWh/year.
Part-use factors serve to adjust the savings calculations to account for the fact that not all refrigerators are plugged in year-round. Secondary refrigerators or primary refrigerators that are in a secondary residence are likely to be unp...
AI summary Part-use factors adjust savings calculations for refrigerators not used year-round, such as secondary or seasonal units. The 2014 participant survey estimated refrigerator usage time, with the Evaluator using declared months of use to establish a ratio for part-use factors.
Table 9: Final Energy Consumption Values for Refrigerators Measured Consumption (kWh/year) Part-use Factor Final Consumption (kWh/year) Retired Refrigerator 896 0.88 788 Replacement Refrigerator 450 0.88 396 3.1.2 Distortion Effects
AI summary Table 9 presents final energy consumption values for retired and replacement refrigerators, showing a significant reduction in energy use from 788 kWh/year to 396 kWh/year. Section 3.1.2 discusses distortion effects, which may relate to how energy consumption data is influenced by various factors.
Induced Consumption Induced consumption is assessed so participants who would have unplugged their appliances without replacing it in the absence of the program can be taken into account. Induced consumption is deducted from the gross savi...
AI summary Induced consumption is assessed to account for appliance replacements that may have been influenced by the program. A second validation question was added to ensure that replacements were due to the program and not other factors. The induced replacement proportion is 1%, a significant decrease from last year due to questionnaire improvements.
3.2.1 Gross Unitary Savings For all freezers retired in 2014, ENSC uses a gross unitary savings value of 1,049 kWh per year, which corresponds to the average energy consumption value of retired freezers established during the 2013 impact e...
AI summary The document discusses the gross unitary savings value for retired freezers in 2014, using a value of 1,049 kWh per year based on the 2013 impact evaluation. The Econoler team updated this value using 2014 metering activity and participant survey results.
Average Energy Consumption of Replacement Freezers Three energy consumption levels are also attributed to possible categories of freezer replacement, as demonstrated for refrigerators in Section 3.1.1. The energy consumption established in...
AI summary The document discusses the average energy consumption of replacement freezers, referencing a 2013 evaluation report and methods used for refrigerators. Energy consumption levels are estimated based on data from retired freezers aged 10 to 19 years.
Table 16: Average Annual Consumption for Freezer Replacement Type of replacement Annual Energy Consumption Proportion New High Efficiency Freezer 518 kWh/year 86% Used High Efficiency Freezer 589 kWh/year 6% New Standard Efficiency Freezer...
AI summary Table 16 presents the average annual energy consumption for different types of freezer replacements, highlighting the energy efficiency differences between new and used freezers, as well as between high and standard efficiency models.
Part-use Factors All freezers are considered to be primary, meaning that none is less used than the others. Only one part-use factors value is therefore calculated for freezers, based on the results of the 2014 Annual Survey. To establish...
AI summary The document discusses the calculation of part-use factors for freezers based on survey data from 2014. Freezers are categorized as either not in use, used part-time, or used full-time, with corresponding part-use factors. These factors are applied to determine the annual energy consumption values for both retired and replacement freezers.
Table 18: Final Energy Consumption Values for Freezers Measured Consumption (kWh/year) Part-use Factor Final Consumption (kWh/year) Retired Freezer 916 0.90 824 Replacement Freezer 543 0.90 489 3.2.2 Distortion Effects
AI summary Table 18 presents final energy consumption values for retired and replacement freezers, showing a reduction in energy use from 916 kWh/year to 489 kWh/year. Section 3.2.2 discusses distortion effects, likely related to energy consumption or efficiency impacts.
Average Consumption of Retired Room Air-conditioners The Evaluator reviewed the estimated annual energy consumption and the unitary savings value for retired room air conditioners by performing a literature review. The annual usage of 310....
AI summary The Evaluator calculated the average annual energy consumption of retired room air conditioners, using data on their capacity and efficiency standards. The average consumption was determined to be 279 kWh, based on an EER of 8.0 and an annual usage of 310.6 hours.
Average Energy Consumption of Replacement Room Air-conditioners Because the sample of participants surveyed about the retirement of their room air conditioners was too small to draw conclusions on the type of equipment they purchased as a...
AI summary The document assumes that replacement room air conditioners meet ENERGY STAR efficiency standards (EER 11.2) due to limited survey data. It uses the same capacity and operation hours as retired units to calculate an annual energy consumption of 199 kWh.
3.3.2 Distortion Effects This following section presents the distortion effects taken into account to calculate unitary savings for air conditioners.
AI summary This section discusses the distortion effects considered in calculating unitary savings for air conditioners, highlighting the impact of these effects on energy efficiency calculations.
Secondary Market Impacts Secondary market impacts for room air conditioners are calculated in a way similar to the calculations applied to refrigerators and freezers. The table below presents all the possible scenarios for room air conditi...
AI summary The text discusses the calculation of secondary market impacts for room air conditioners, using a method similar to that applied to refrigerators and freezers. A table is mentioned, which outlines various scenarios for room air conditioners transferred to the secondary market and their corresponding energy impacts.
Table 24: Proportions of Secondary Market Impacts for Room Air Conditioners Would-be Acquirer Finds an Alternate Unit Proportion Alternate Type Proportion Secondary Market Impacts Value Old Unit 50% Consumption of retired appliance Yes 50%...
AI summary Table 24 outlines the proportions of secondary market impacts for room air conditioners, showing that 50% of would-be acquirers find an alternate unit, either an old unit or a new standard efficiency appliance, with associated consumption impacts. The same assumptions as for refrigerators and freezers are applied here.
Table 25: Proportions of Induced Consumption for Room Air Conditioners Replaced the Recycled Unit Proportion Program Induced Replacement Proportion Overall Proportion Yes 200/ Yes 0% 0% res 38% No 100% 38% No 62% 62% Total 100% 3.3.3 Net U...
AI summary Table 25 presents data on the proportions of induced consumption for room air conditioners, showing that 38% of replacements were program-induced, while 62% were not. This data is relevant to understanding the impact of energy efficiency programs on consumer behavior.
Table 26: Savings per Room Air-conditioning Unit Free-ridership ar nd Sec ondary Market Impac ts Would Have Discard Would-be Acquirer % Alternate ate Overall Energy Consumption (kWh/year) Savings Kept Unit % Scenario % Finds an Alternate U...
AI summary Table 26 presents savings per room air-conditioning unit, analyzing scenarios where units are discarded, transferred, or disposed of. It includes data on energy consumption, savings, and program-induced consumption, providing insights into free-ridership and secondary market impacts.
Table 27: Validated Gross Energy and Peak Demand Savings Refrigerators Freezers Room Air Conditioners Total Energy Savings Number of Units Retired 4,745 2,540 123 7,408 Unitary Savings (kWh) 788 824 279 - Total Gross Energy Savings – at me...
AI summary Table 27 presents validated gross energy and peak demand savings from appliance replacement pilot projects, including data on refrigerators, freezers, and room air conditioners. The table includes metrics such as number of units retired, energy savings, and peak demand savings at both the meter and generator levels.
In 2014, ENSC conducted two pilot projects with large institutional facilities to replace their refrigerators, mini refrigerators and freezers with new, energy-efficient appliances. Unitary savings for those projects were calculated separa...
AI summary In 2014, ENSC conducted pilot projects to replace refrigeration units in large institutional facilities with energy-efficient appliances. Savings were calculated using adapted metering data and EnerGuide values, with line loss adjustments applied to estimate generator-level savings.
3.10 Overall Net Savings The net energy savings are estimated by multiplying the gross savings by the NTGR and the interactive effects, based on the equation below. Net Energy Savings = Gross Energy Savings × NTGRequiv × (1 - Interactive E...
AI summary The net energy savings are calculated by multiplying gross savings by NTGR and interactive effects. The overall net energy and peak demand savings for ARET are 3.492 GWh and 0.555 MW at the meter, increasing to 3.585 GWh and 0.570 MW at the meter when including appliance replacement pilot projects.
Table 30: Validated Net Energy and Peak Demand Savings Refrigerators Freezers Room AC Units Appliance Replacement Pilot Total Energy Savings Total Gross Energy Savings – at meter (GWh) 3.739 2.093 0.034 0.094 5.960 NTGR 0.60 0.58 0.55 1.00...
AI summary Table 30 presents validated net energy and peak demand savings across various appliance categories, including refrigerators, freezers, and room air conditioners. It includes data on gross and net energy savings, interactive effects factors, line loss factors, and peak demand savings at both the meter and generator levels.
APPENDIX I PARTICIPANT SURVEY QUESTIONNAIRE Could I speak with [INSERT NAME]? 1. Yes [GO TO INTRODUCTION] 2. No [SAY "Perhaps you can help me anyway." GO TO INTRODUCTION] Hello, my name is _________ from CRA (Corporate Research Associates)...
AI summary This document is a participant survey questionnaire for Efficiency Nova Scotia Corporation's Appliance Retirement Program, conducted in 2014. It aims to collect feedback from participants who had old appliances removed and recycled, and to verify details of their participation, including the number of appliances and any rebates received.
[PROGRAMMER: EACH RESPONDENT WILL BE ASKED ABOUT ONE APPLIANCE. IF AIR CONDITIONER, ASK ABOUT AIR CONDITIONER ONLY AND NO OTHER APPLIANCE.]. APPLIANCE QUOTA Refrigerator (RF) n=80 Freezer (FZ) n=80 Air Conditioner (AC) n=4011 TOTAL n=200 R...
AI summary The text outlines a program where each respondent is asked about one appliance, with specific quotas for refrigerators, freezers, and air conditioners. The quotas are set at 80 for refrigerators, 80 for freezers, and 4011 for air conditioners, totaling 200 respondents.
Replacement Section (RE Series) - RE1. Did you replace the [refrigerator/stand-alone freezer/air conditioner unit] that you turned in through Efficiency Nova Scotia's Appliance Retirement Program? - 1. Yes - 2. No [GO TO FREERIDERSHIP SECT...
AI summary This section of the document includes a series of questions aimed at understanding customer behavior related to appliance replacement, particularly through Efficiency Nova Scotia's Appliance Retirement Program. It explores motivations, the influence of the program, and whether rebates were a determining factor in replacement decisions.
FR3. [ASK U6 FOR REFRIGERATORS ONLY] [ASK ONLY IF FR2a=2 OR IF FR2b=2] If you had kept the [refrigerator], would you have kept it in the same location you mentioned earlier? That is would it have been located in: [READ IN ANSWER FROM U6]?...
AI summary The text outlines a series of questions related to the disposal of appliances, specifically refrigerators, stand-alone freezers, and air conditioner units, and explores factors influencing participation in the Efficiency Nova Scotia program, including rebate incentives and disposal methods.
Spillover Section (SO Series) - SO1. Since participating in Efficiency Nova Scotia's Appliance Retirement Program, have you disposed of other appliances WITHOUT RECEIVING A REBATE? - 1. Yes - 2. No [SKIP TO PROGRAM PARTICIPATION SECTION] -...
AI summary This section of the proceeding asks participants in Efficiency Nova Scotia's Appliance Retirement Program whether they have disposed of other appliances without receiving a rebate, and if so, which types of appliances were disposed of.
Program Awareness and Satisfaction (CS Series) CS1. How did you first learn about this program? [DON'T READ; ALLOW MULTIPLE RESPONSE BUT DO NOT PROBE FOR MULTIPLE] 1. 2. 3. 4. 5. 6. Media advertising Contacted directly by Efficiency Nova S...
AI summary The document outlines a survey on program awareness and satisfaction related to the Appliance Retirement Program, focusing on how respondents learned about the program, their contact with Efficiency Nova Scotia, and their satisfaction with various aspects of the program's performance.
RE1. Did you replace the [refrigerator/stand-alone freezer/air conditioner unit] that you turned in through Efficiency Nova Scotia's Appliance Retirement Program? 2012 2013 2014 Replacement Refrigerators (%) Freezers (%) Air conditioners (...
AI summary The text presents survey data from Efficiency Nova Scotia's Appliance Retirement Program, showing replacement rates and reasons for replacing refrigerators, freezers, and air conditioners between 2012 and 2014. It also explores whether the replacement appliances were new or used.
CS27. Based on your personal experience, would you definitely, probably, probably not, or definitely not recommend the programs offered by Efficiency Nova Scotia to others? Would Recommend ARet to Others 2012 2013 2014 Sample Size 57 201 2...
AI summary The response to CS27 indicates that a high percentage of participants (89% in 2012, 91% in 2013, and 89% in 2014) would definitely recommend the programs offered by Efficiency Nova Scotia to others, with a small percentage (11% in 2012, 9% in 2013, and 10% in 2014) indicating they would probably recommend them.
CS28. How likely would you be to participate in other programs offered by Efficiency Nova Scotia if your household qualified? Would you definitely, probably, probably not, or definitely not participate in other programs?
AI summary This question asks respondents about their likelihood of participating in other programs offered by Efficiency Nova Scotia if their household qualified for them, with response options ranging from 'definitely' to 'definitely not'.
APPENDIX IV INTERNAL SPILLOVER METHODOLOGY Internal spillover was measured using a participant survey. For ARet, internal spillover can occur when participants decide to retire or replace other appliances on their own following their previ...
AI summary This section describes the methodology used to measure internal spillover in the ARet program. Internal spillover occurs when participants retire or replace appliances without receiving a rebate, influenced by their previous participation in the program. A survey was conducted to determine the extent of this spillover and estimate the associated energy savings.
Partner Satisfaction and Barriers The DA was asked to share its feedback about Instant Savings and ENSC in 2014. For the most part, the DA was pleased with the program's success, program marketing, outreach activities and the relationship...
AI summary The DA expressed overall satisfaction with Instant Savings and ENSC, though noted varying retailer engagement as a barrier. Retailers praised relationships and communication but were dissatisfied with delays in product approvals and rebate processing.
Awareness and Education Similar to previous years, ENSC sources were the most common way for participants to find out about Instant Savings. These sources included media advertising in general, ENSC representatives during an in-store event...
AI summary ENSC sources, including media advertising, in-store events, and promotions, were the primary means of awareness for Instant Savings. Word of mouth also played a significant role. The DA noted that Instant Savings was successful in raising energy efficiency awareness and ENSC visibility, with customer engagement events effectively informing clients about eligible products.
Energy Savings The impact evaluation was conducted on the basis of the data and information gained from three main activities: a review of the unitary savings used to estimate gross savings; the CFL and LED lampbuyer intercept survey; and...
AI summary The impact evaluation of energy savings considered data from unitary savings reviews, a lampbuyer intercept survey, and retailer interviews. The Econoler team calculated gross and net savings, factoring in free-ridership and spillover for CFLs and LED lamps. A NTGR of 1 was applied to other products due to insufficient buyer data.
Table 1: Distortion Effects and Net-to-Gross Ratio Product Category Free-ridership Spillover NTGR Regular CFLs 54% 28% 0.74 LED Lamps 0% 20% 1.20 All Other Products - - 1.00 The evaluation has revealed that Instant Savings generated net en...
AI summary Table 1 presents the distortion effects and net-to-gross ratio (NTGR) for different product categories, including Regular CFLs, LED Lamps, and All Other Products. The evaluation highlights that the Instant Savings program achieved significant energy and peak demand savings in 2014.
Table 2: Comparison of Tracked and Evaluated Savings at the Generator Initial Gross Savings Installed Gross Savings Installed Gross Savings with Interactive Effects NTGR Net Savings Energy Savings Tracked Savings from ENSC 16.879 GWh 15.92...
AI summary Table 2 compares tracked and evaluated savings from Energy Efficiency Nova Scotia Corporation (ENSC) programs, including energy savings and peak demand savings. The table includes metrics such as initial gross savings, installed gross savings, net-to-gross ratio (NTGR), and net savings for both tracked and evaluated results.
RECOMMENDATIONS Overall, the Econoler team is of the opinion that though Instant Savings contributed to the market transformation in Nova Scotia, its net impact decreased significantly this year. In addition to the general recommendations...
AI summary The Econoler team acknowledges the contribution of Instant Savings to market transformation in Nova Scotia but notes a significant decrease in its net impact this year. Specific recommendations are made to optimize the program, alongside general recommendations for all ENSC program components from the 2014 evaluation report.
, as incandescent have already started being phased out as required by the federal regulation. ENSC should also expect unitary savings of lighting products to continue decreasing in the years to come. 2014 Instant-R5. Analyze the CEE Tier...
AI summary The text discusses the phase-out of incandescent lighting and the need for ENSC to update eligibility criteria for energy-efficient appliances, particularly refrigerators and clothes washers, due to changes in CEE Tier III standards. It emphasizes the importance of aligning with new federal standards and ensuring product availability in Nova Scotia.
Table 3: List of Discounts per Product $3 on ENERGY STAR® Regular CFLs (multipacks of two or more) – spring only $5 on Power Bars with Integrated Timers $3 on ENERGY STAR® Specialty CFLs (single or double packs) – spring only $10 (spring)...
AI summary Table 3 outlines various discounts offered on energy-efficient products such as CFLs, LED lamps, and thermostats, with varying amounts depending on the product type and season. The text also mentions that in 2014, the Instant Savings program was promoted through multiple channels including in-store promotions, online platforms, and events.
2.2.3 Interviews with Retailers In the fall of 2014, CRA conducted a total of 14 in-depth interviews with retailers (also known as "partners"). These interviews focused on two specific products: ENERGY STAR® CFLs and ENERGY STAR® LED lamps...
AI summary In the fall of 2014, CRA conducted 14 in-depth interviews with retailers to assess their experiences with ENERGY STAR® CFLs and LED lamps, focusing on market spillover effects and satisfaction with the Instant Savings program.
Table 5: Implementation Status of Recommendations in the 2012 and 2013 Executive Summaries Recommendation Status 2012 Recommendations 2012 Instant-R1. Document the AIR MILES® approach No longer applicable 2012 Instant-R2. Generate greater...
AI summary This table outlines the implementation status of recommendations from the 2012 and 2013 Executive Summaries, focusing on energy efficiency programs such as the promotion of LED products, retailer involvement, and adjustments to tracking sheets and savings calculations for lighting products.
2012 Executive Summary Recommendations The Evaluator noticed that four of the five recommendations were implemented by ENSC and allowed for overall program improvement. The only recommendation that was not implemented is the one requesting...
AI summary The Evaluator noted that four of five recommendations were implemented by ENSC, leading to program improvements. The unimplemented recommendation involved documenting the AIR MILES approach. The removal of CFLs and changes to refrigerator and washer eligibility were made based on recommendations to improve energy efficiency and market penetration.
2013 Executive Summary Recommendations Four of the five recommendations were implemented by ENSC. Acting on these recommendations, ENSC increased promotion of products other than CFLs and LED lamps, and continued conducting general populat...
AI summary In 2013, ENSC implemented four recommendations to promote energy-efficient products beyond CFLs and LED lamps. Findings from surveys showed low awareness and purchase intent for other discounted products. ENSC conducted a price study, held in-store events, and developed a new POP system to promote these products. Additionally, they launched the Instant Savings application to highlight savings from eligible products.
aluator commends ENSC on its continued efforts to improve this percentage every year, and reiterates that this information is helpful in planning data collection activities, such as intercept surveys. The retailers also provide product-spe...
AI summary The Evaluator commends ENSC for improving the accuracy of wattage data in the tracking system, noting significant improvements since last year. However, minor errors were still found, such as incorrect wattage entries and grouping of similar products under a single transaction, which can affect savings calculations.
Effectiveness of Instant Discounts Awarded at the Cash Most retailers automatically awarded the discount at the cash register when a qualifying product was purchased. In four out of nine 2 visits, however, the mystery shopper had to ask th...
AI summary A study found that in most cases, retailers automatically applied instant discounts at the cash register when a qualifying product was purchased. However, in some cases, the discount was not applied or was unclear to the shopper, requiring them to ask the cashier for clarification.
Product Promotional Displays For the fall campaign, the mystery shopper noticed that a slightly wider array of POP tools was used by retailers. The most common POP tools were bin violators, vertical and horizontal hang tabs, tent cards, sh...
AI summary The fall campaign saw a more even distribution of POP displays across store sections, with less focus on lighting products due to the removal of CFLs. However, some inaccuracies in rebate information and a lack of promotion of other ENSC programs were noted. In-store events were generally successful but had some shortcomings in communication.
n for this was the time they waited to receive the final list of rebated products. Although ENSC provided such list before the prescribed delay, some retailers still considered the wait time too long. That said, opinions about Instant Savi...
AI summary The Delivery Agent (DA) expressed satisfaction with the Instant Savings program, noting its success in meeting objectives, awareness, and market penetration. While some retailers found the wait time for the final list of rebated products too long, the DA praised the collaborative relationship with ENSC and retailers, emphasizing improvements in communication and the value of social media for outreach.
le impact on the customer's decision. Notwithstanding this, some retailers still believed the reduced number of rebated appliances limited the program's impact on sales of energy-efficient appliances. Retailers were highly satisfied with t...
AI summary Retailers expressed satisfaction with their relationship with the DA, though they felt the reduced number of rebated appliances limited the program's impact. Instant Savings influenced product quantity more than variety, with customer interest in LED technology prompting store staff to be more knowledgeable.
4.2.1 Instant Savings Awareness As part of the intercept survey conducted in participating retail stores, consumers who purchased discounted products during the Instant Savings markdown periods in the spring and fall 2014 were interviewed....
AI summary A survey of consumers who purchased discounted energy-efficient products during Instant Savings markdowns in 2014 found that 78% were aware of the program. ENSC advertising was the primary source of awareness, with in-store promotions and posters being effective communication tools.
Table 6: Sources of Awareness Sources of 2012 2013 2014 Awareness Overall CFL Purchasers LED Lamp Purchasers Overall CFL Purchasers LED Lamp Purchasers Overall CFL Purchasers LED Lamp Purchasers Sample Size 91 51 35 199 36 159 231 32 203 T...
AI summary Table 6 presents data on the sources of awareness for energy efficiency programs among CFL and LED lamp purchasers from 2012 to 2014. It highlights the percentage of respondents who became aware of these programs through various channels such as advertising, in-store promotions, word of mouth, and ENSC representatives.
Table 7: Discount Awareness Discount 2012 2013 2014 Awareness Overall CFL Purchasers LED Lamp Purchasers Overall CFL Purchasers LED Lamp Purchasers CFL Purchasers LED Lamp Purchasers Sample Size 164 99 65 241 44 91 294 43 251 Yes, was awar...
AI summary Table 7 presents data on discount awareness among CFL and LED lamp purchasers in 2012, 2013, and 2014. The data shows that a majority of respondents were aware of discounts before making purchases, with higher awareness rates for LED lamp purchasers compared to CFL purchasers.
Nearly all participants had heard of ENSC, which is the case for both CFL and LED purchasers.
AI summary The text notes that nearly all participants were familiar with ENSC, as well as CFL and LED purchasers, indicating a level of awareness among stakeholders regarding energy efficiency initiatives and lighting technologies.
Table 8: ENSC Awareness ENSC 2012 2013 2014 Awareness Overall CFL Purchasers LED Lamp Purchasers Overall CFL Purchasers LED Lamp Purchasers Overall CFL Purchasers LED Lamp Purchasers Sample Size 164 96 61 241 44 191 294 43 256 Yes 87% 83%...
AI summary Table 8 presents ENSC awareness data across multiple years, showing the percentage of respondents who were aware of Efficiency Nova Scotia Corporation (ENSC), with breakdowns by overall awareness, CFL purchasers, and LED lamp purchasers for the years 2012, 2013, and 2014.
4.2.2 Purchases Survey results from the table below suggest a shift in purchases from CFL lamps to LED lamps during the Instant Savings campaign periods since 2012. The majority of the interviews completed in 2014 were with LED purchasers....
AI summary The text discusses a shift in consumer purchases from CFL lamps to LED lamps during the Instant Savings campaign periods since 2012. Survey data from 2012 to 2014 show a significant increase in LED lamp purchases, with a corresponding decline in CFL purchases. Despite this, many participants still had CFLs installed in their homes at the time of the survey.
4.2.3 Influence Notably, the discount is less likely to influence the decision to purchase CFL bulbs than in the past. It should be noted that CFLs were no longer included as part of Instant Savings following the spring campaign, partly du...
AI summary The discount on CFL bulbs has less influence on purchasing decisions compared to the past, leading to their exclusion from the Instant Savings program. However, the discount still influences LED bulb purchases, as shown in Table 11.
Table 11: Importance of Discount in Influencing Installation Importance of 2012 2013 2014 Discount in Influencing Decision to Install Energy efficient Products CFL Purchasers LED Lamp Purchasers CFL Purchasers LED Lamp Purchasers CFL Purch...
AI summary Table 11 presents data on the importance of discounts in influencing the purchase of energy-efficient products, specifically CFLs and LED lamps, across years 2012 to 2014. The mean scores indicate that discounts were perceived as somewhat influential, with higher scores for LED lamp purchasers compared to CFL purchasers in most years.
5 IMPACT EVALUATION The objective of the 2014 Instant Savings impact evaluation is to determine the gross and net energy savings generated by the energy-efficient products bought through the program. Both electrical energy and peak demand...
AI summary This section evaluates the impact of the 2014 Instant Savings program, focusing on energy and peak demand savings from energy-efficient products. It uses unitary savings values, demand-to-energy ratios, interactive effects, free-ridership, and spillover effects. Unlike the 2013 evaluation, a replacement ratio was not applied to CFL and LED lighting products due to the adoption of the Uniform Method Project (UMP).
5.1 Gross Savings The quantities of products sold through the Instant Savings spring and fall campaigns are captured in the tracking sheet. For each product category, ENSC used the unitary savings values from last year's evaluation report....
AI summary This section discusses how Efficiency Nova Scotia Corporation (ENSC) estimated unitary savings values for products sold through the Instant Savings campaigns, using revised values from recent studies and customized engineering calculations.
Tracked Savings The quantity of CFLs sold through the program was recorded in the tracking sheet according to these types of CFLs: & lt;sup>3 Ontario Power Authority (OPA), 2011 Prescriptive Measures and Assumptions Version 1, March 2011....
AI summary The document discusses the calculation of energy savings from CFLs sold through a program, using specific formulas and data sources. Regular and specialty CFLs have different unitary savings values and replacement ratios, derived from studies and surveys including Hydro-Québec and the Atlantic Quarterly survey.
Revised Savings Because both regular and specialty CFLs are no longer part of the Instant Savings rebated products as of the 2014 fall campaign, the unitary savings values were not reviewed this year, as last year's evaluation results are...
AI summary The document discusses the revised savings methodology for lighting programs, noting that unitary savings values for CFLs were not reviewed due to unchanged assumptions. The methodology now follows UMP Chapter 67, using one of two approaches to estimate efficient lamp replacements. The Evaluator chose to apply the first approach, impacting free-ridership estimates and the replacement ratio.
Displaced Wattage In 2014, the displaced wattage was revised according to the LED wattage values found in the 2014 tracking sheet and the average equivalent lamp wattage values specified by the manufacturer. Last year, the replaced lamp wa...
AI summary In 2014, the displaced wattage methodology was revised to better reflect the actual lamp replacements, considering the share of each type of replaced lamps. The Evaluator used weighted averages of equivalent wattages from incandescent, halogen, CFL, and LED lamps to estimate displaced wattage, particularly for LED lamps, which were found to have a displaced wattage of 18.5 W. The adjustment aligns with the UMP recommendations and affects savings evaluations for Instant Savings.
Hours of Operation To review the hours of operation, the Econoler team has applied some of the principles promoted by the UMP. A metering study specific to Nova Scotia would have been the ideal scenario, but this option was not available d...
AI summary The Econoler team used principles from the Uniform Methods Protocol (UMP) to determine the hours of operation for LED lamps in Nova Scotia's Instant Savings program, relying on secondary data and metering studies of CFLs due to budget constraints and limited LED-specific studies.
Table 13: Residential Lighting Metering Studies Region and Year Hours of Use (hrs/day) Number of Homes Number of Loggers Metering Period Hydro-Québec, 201115 Indoor: 2.68 Outdoor: 3.6 200 787 2010 Michigan, 201216 Indoor: 2.2 Outdoor: 3 15...
AI summary Table 13 presents data from residential lighting metering studies conducted in various regions, including Hydro-Québec, Michigan, New England States, and Illinois. The data includes hours of use, number of homes, loggers, and metering periods, providing insights into residential lighting consumption patterns.
In-service Rate For upstream programs like Instant Savings, the UMP has made the following recommendation: "In-service rates should be calculated through an in-home audit. Since program bulbs cannot be easily identified, the in-service rat...
AI summary The UMP recommends calculating in-service rates for upstream programs like Instant Savings using in-home audits and recent bulb purchases. However, the Evaluator decided to claim all savings within the year of purchase due to the high cost and complexity of determining in-service rates for LED lamps in Nova Scotia, as existing studies are based on CFLs and are not applicable to LEDs.
Tracked Savings For LED recessed downlight fixtures, ENSC used an annual unitary savings value of 47.5 kWh, based on the value estimated during the 2013 evaluation. The average displaced wattage value was calculated by comparing the averag...
AI summary The document discusses the calculation of annual unitary savings for LED recessed downlight fixtures, using data from a 2013 evaluation. It compares the average wattage of LED fixtures with equivalent halogen lamps and uses data from a Hydro-Québec study to estimate annual hours of operation.
Displaced Wattage The displaced wattage was revised according to the real wattage values of the 10 best-selling models of LED recessed downlight fixtures found in the 2014 tracking sheet (which represented over 66% of all recessed LED lamp...
AI summary The displaced wattage was recalculated based on the real wattage values of the 10 best-selling LED recessed downlight models from 2014 and the average equivalent halogen lamp wattage, resulting in a displaced wattage of 47.8 watts.
Hours of Operation To the best of the Evaluator's knowledge, no organization has measured and released reliable and trustworthy statistics specifically on the hours of operation of LED recessed downlight fixtures installed in residential f...
AI summary The Evaluator used the 2014 New England states metering study's estimate of 2.9 hours per day for LED lamp operation, as no reliable data specific to LED recessed downlight fixtures in residential settings was available.
Unitary Savings The unitary savings value was revised according to the displaced wattage of 47.8 watts and the hours of operation estimated at 2.9 hours per day using the following equation: $$Annual\ Unitary\ Savings = \frac{(47.8) \times...
AI summary The unitary savings value was calculated using a displaced wattage of 47.8 watts and an estimated 2.9 hours of daily operation, resulting in an annual savings of 50.6 kWh. This value was used for evaluating gross savings for LED recessed downlight fixtures sold through the Instant Savings program.
Tracked Savings For dimmer switches, ENSC used a unitary savings value of 23.5 kWh per year. This value is based on the 2011 OPA report and hours of operation for indoor bulbs estimated at 2.68 hrs/day. The calculation is shown in the tabl...
AI summary The document discusses the use of a unitary savings value of 23.5 kWh per year for dimmer switches, based on the 2011 OPA report and estimated indoor bulb operation hours of 2.68 hrs/day.
Table 14: ENSC's Unitary Savings Calculations for Dimmer Switches Parameter Value Wattage 2 × 60 W = 120 W Dimmed Wattage 80% × 120 W = 96 W Operating Time 2.68 h/day Annual Savings 23.5 kWh Revised Savings
AI summary Table 14 provides ENSC's unitary savings calculations for dimmer switches, including wattage, dimmed wattage, operating time, and annual savings. The revised savings section suggests an update or adjustment to these calculations.
Table 15: Tracked Unitary Savings Value for Indoor Motion Sensors Parameter Value Fixture Wattage (2 × 60 W) = 120 W Old Operating Time 2.68 h/day New Operating Time – with sensor [2.68 × (1 – 24%)] = 1.23 h/day Annual Savings 63.5 kWh Rev...
AI summary Table 15 presents the tracked unitary savings value for indoor motion sensors, showing a reduction in operating time from 2.68 hours per day to 1.23 hours per day, resulting in an annual energy savings of 63.5 kWh.
Revised Savings The Econoler team conducted a literature review to determine whether a more accurate unitary savings value could be established and concluded that no additional information had been published on this type of product. The sa...
AI summary The Econoler team reviewed literature to establish a more accurate unitary savings value but found no new information. They continued using prior assumptions on fixture and dimmed wattage, adjusting operating hours to reflect indoor lighting values as applied by the team.
Table 17: Revised Unitary Savings for Outdoor Motion Sensors Parameter Value Fixture Wattage 242.6 W Old Operating Time 4.75 h/day New Operating Time – with sensor 2.95 h/day Annual Savings 159 kWh
AI summary Table 17 presents revised unitary savings for outdoor motion sensors, showing a reduction in operating time from 4.75 hours per day to 2.95 hours per day, resulting in an annual energy savings of 159 kWh.
Table 18: Unitary Savings Calculations for Power Bars with Integrated Timer Parameter Entertainment Centre Computer System Lighting Other Proportion 40.3% 15.7% 19.4% 24.6% Average Standby Wattage 38.1 W 28 W 60 W 28 W Old Operating Time 9...
AI summary Table 18 presents unitary savings calculations for power bars with integrated timers across various categories such as Entertainment Centre, Computer System, Lighting, and Other. The table includes parameters like proportion, average standby wattage, operating time, and calculated unitary savings in kWh/year.
Table 19: Calculation Assumptions for Load Sensing Power Bars Parameter Value Idle power of home office equipment 4.9 W (five-plug) 5.88 W (seven-plug) Daily hours of idle computer time 20 h/day Unitary savings value for home office equipm...
AI summary Table 19 outlines calculation assumptions for load sensing power bars, including idle power consumption for home office equipment and entertainment systems, daily usage hours, and unitary savings values for various plug configurations.
Table 20: Tracked Unitary Savings Estimation Based on Results from Hydro-Québec's Evaluation of Electronic Thermostat Savings Housing Type Calculation Parameter Single Detached Duplex/Triplex/ Townhouse Apartment Proportion of Each Dwellin...
AI summary Table 20 estimates energy savings from electronic thermostats in different housing types based on Hydro-Québec's evaluation. It shows unitary savings for thermostat accuracy and temperature setback, with weighted average savings per dwelling type.
Table 21: Measuring Studies on Programmable Thermostats Energy Savings Organization Location & Year Sample Size Conclusions GasNetworks Northeast 2006 7,000 homes 75 ft³ gas consumption reduction per PT. In the control group with MT, 36% o...
AI summary Table 21 presents studies on the energy savings from programmable thermostats. It includes data from GasNetworks, KeySpan Energy Delivery, and Hydro-Québec LTE, detailing sample sizes, locations, and conclusions about energy consumption reductions. Hydro-Québec's 2009 report is highlighted for its accuracy in estimating savings from room-by-room thermostat models.
Table 22: Revised Unitary Savings Value for CEE Tier III Refrigerators Parameters Values Base Annual Consumption – Standard Refrigerator 567 kWh New Annual Consumption – CEE Tier III Refrigerator 396 kWh Annual Unitary Savings 171 kWh 5.1....
AI summary Table 22 presents the revised unitary savings value for CEE Tier III refrigerators, showing a reduction in annual energy consumption from 567 kWh to 396 kWh, resulting in annual unitary savings of 171 kWh. The section also mentions CEE Tier III Clothes Washers, indicating ongoing analysis of energy efficiency standards.
Table 23: Energy Consumption Breakdown for Standard and Efficient Clothes Washers Energy Consumption Breakdown for Clothes Washers Proportion of Overall Consumption33 Standard Clothes Washer Electricity Consumption (kWh) Efficient Clothes...
AI summary Table 23 provides an energy consumption breakdown for standard and efficient clothes washers, highlighting the proportion of overall consumption and electricity usage. The text explains how savings from the water-heating system were estimated using data from the ENERGY STAR database and assumptions about internal heaters and DHW tank usage.
31 Ad Hoc Recherche, Rapport d'évaluation, Programme : Produits Mieux Consommer – Électroménagers Energy Star (Années 2008 et 2009) , p. 18, available at < http://www.regie-energie.qc.ca/audiences/Suivis/Suivi-R-3644-2007- ProcedurePGEE/HQ...
AI summary The text references a report evaluating the 'Better Consumption Products – Energy Star Appliances' program for the years 2008 and 2009. It mentions percentages (16% and 43%) and includes an image related to a DHW tank, suggesting a focus on energy efficiency and appliance performance.
the proportion of electric DHW tanks in Nova Scotia 34 was used to calculate the overall proportion of electrically heated water for both standard and efficient clothes washers. Source of Hot Water for Clothes Washers Clothes Washer Water-...
AI summary The text discusses the proportion of electric DHW tanks in Nova Scotia and their use in calculating the overall proportion of electrically heated water for standard and efficient clothes washers. It includes a table with data on the source of hot water for clothes washers.
Non-electric 27% 73% Table 24: Water-heating Sources for Clothes Washers By adding the proportion of internal electric heaters to the proportion of electric DHW tanks, the proportion of electric water-heating was established at 56 percent...
AI summary The text discusses the calculation of electric water-heating proportions for clothes washers, including an adjustment factor for cold water usage. It references tables that show calculations for total electricity consumption for standard and efficient washers.
Table 25: Electricity Consumption for Standard Clothes Washers Energy Consumption Component Energy Consumption Electricity Consumption (kWh) Adjustment Factor Adjusted Electricity Consumption (kWh) Water-heating System 154 87 0.67 58 Inter...
AI summary The text presents two tables comparing the electricity consumption of standard and efficient clothes washers, including components like water-heating systems, internal dryers, and washing machine drums. Adjustments are made based on factors such as energy efficiency, and the data is sourced from Natural Resources Canada.
5.1.16 Revised Gross Savings The annual energy and peak demand gross savings for each category of products installed through Instant Savings are presented in Table 27. They were calculated using the revised unitary savings values and the d...
AI summary The document presents revised gross savings for energy and peak demand from Instant Savings programs, calculated using updated unitary savings values and a demand-to-energy ratio. Total savings at the meter are 9.776 GWh and 1.545 MW, while generator-level savings are 10.754 GWh and 1.699 MW, factoring in a line loss of 1.100.
Table 27: Evaluation Results – Gross Energy and Peak Demand Savings by Product – Lighting Products Product Category Regular CFL Specialty CFL LED Lamp LED Recessed Downlight Dimmer Switch Indoor Motion Sensor Motion Sensor with Dimmer Swit...
AI summary Table 27 presents evaluation results for gross energy and peak demand savings by product category for lighting products, including CFLs, LEDs, and motion sensors. The table includes data on the number of units installed, energy savings in kWh and GWh, and peak demand savings in MW across different seasons and product types.
Table 28: Evaluation Results – Gross Energy and Peak Demand Savings by Product – Other Products Product Category Power Bar with Timer Smart Power Bar Heavy Duty Timer Clothes lines Program mable Ther mostat CEE Tier III Refrige rator CEE T...
AI summary Table 28 presents evaluation results of energy and peak demand savings by product category for other products, including power bars, timers, clothes lines, and refrigerators. The data includes units installed during Spring and Fall, energy savings in GWh, and peak demand savings in MW, with line loss factors applied for both meter and generator levels.
In a residence, interactive effects occur when the implementation of energy efficiency measures has an impact on the energy consumption of other elements such as heating or cooling systems. For instance, replacing incandescent lighting pro...
AI summary Interactive effects occur when energy efficiency measures, such as replacing incandescent lighting with CFLs or LED lamps, impact heating and cooling loads. A 1992 study by ADS for Hydro-Québec used DOE-2 simulations to evaluate these effects, selecting a low interactive effects scenario for calculations. The table reflects residential heating and cooling data in Nova Scotia, with proportions unchanged from last year.
Parameters % of Residences Interactive Effects38 Electric heating with air-conditioning 33% × 18% = 5.9% -54.4% Electric heating without air-conditioning 33% × 82% = 27.1% -58.0% Non-electric heating with air-conditioning 67% × 18% = 12.1%...
AI summary Table 29 presents interactive effects calculations for lighting products, showing the percentage of residences with different heating and air-conditioning combinations and their corresponding interactive effects. The weighted interactive effects factor is calculated as -18.5%.
These interactive effects occur only when the products are installed inside the house. As CFLs and LED lamps installed through the program can also be used for outdoor lighting, the interactive effects factor for these products was adjuste...
AI summary The interactive effects factor for CFLs and LED lamps was adjusted to account for their use in both indoor and outdoor lighting, based on data from the 2014 Atlantic Quarterly survey. LED recessed downlight fixtures, used only indoors, retained their original interactive effects factor of -18.5 percent.
Table 30: Interactive Effects Factor for CFLs, LED Lamps and LED Recessed Downlights Product Category % Indoor % Outdoor Interactive Effects Factor CFL 86% 14% (86% × -18.5%) + (14% × 0%) = -15.9% LED Lamp 88% 12% (88% × -18.5%) + (10% × 0...
AI summary Table 30 presents the Interactive Effects Factor for different lighting products, including CFLs, LED lamps, and LED recessed downlights, based on their indoor and outdoor usage percentages. The calculation method is outlined for each product category, showing how the factors are derived from their respective usage distributions.
5.3.2 Spillover Instant Savings discounts were offered during two distinct periods: in the spring and in the fall. During and between these two periods, eligible product sales may have occurred due to program influence, even if participant...
AI summary The text discusses spillover effects from the Instant Savings program, analyzing how energy-efficient product sales (CFLs and LED lamps) were influenced by the program even when participants were unaware of the discount. Retailer interviews and market effects were used to estimate program attribution, which decreased for CFLs but remained stable for LED lamps.
Table 32: Evaluation Results – Net Energy and Peak Demand Savings by Product – Lighting Products Product Category Regular CFL Specialty CFL LED Lamp LED Recessed Downlight Dimmer Switch Indoor Motion Sensor Motion Sensor with Dimmer Switch...
AI summary Table 32 evaluates the net energy and peak demand savings from various lighting products, including Compact Fluorescent Lamps (CFL), Light Emitting Diodes (LED), and motion sensors, based on gross energy savings, interactive effects, and net take-up growth rate (NTGR) factors.
Table 34: Comparison of Tracked and Evaluated Savings at the Generator Initial Gross Savings Installed Gross Savings Installed Gross Savings with Interactive Effects NTGR Net Savings Energy Savings Tracked Savings from ENSC 16.879 GWh 15.9...
AI summary Table 34 compares tracked and evaluated savings at the generator level, showing discrepancies between Energy Efficiency Nova Scotia (ENSC) tracked savings and evaluation results for both energy and peak demand savings. Net savings are calculated using the Net Take-Up Growth Rate (NTGR).
CONCLUSION The 2014 evaluation of Instant Savings demonstrated that most of the recommendations made specifically for Instant Savings in the previous evaluations were implemented. The Evaluator commends ENSC on the efforts it made to impro...
AI summary The 2014 evaluation of Instant Savings highlights improvements in the program, including the removal of CFLs and the promotion of LED lamps. However, challenges remain, such as retailer engagement and communication delays. Energy savings declined compared to previous years, partly due to budget cuts and lower unitary savings for certain products.
This Appendix summarizes all the recommendations made by the Evaluator throughout this report as well as the sections from which the recommendations originated. Sections Recommendations 2 Improve training among in-store event representativ...
AI summary The appendix highlights the need to improve training for in-store event representatives, as they lacked knowledge about ENSC programs and provided inaccurate information, according to feedback from mystery shoppers, the DA, and a nationwide retailer.
QB1. On a scale from 1 to 10, where 1 is very poor and 10 is excellent, please rate your satisfaction in regard to the following aspects of the Instant Savings program. Aspects of the program Score 1 = very poor 10 = excellent NA = Not app...
AI summary The Instant Savings program is being evaluated based on participant satisfaction, challenges faced, and barriers to delivery. The survey includes questions about the impact of the program on work processes, the effectiveness of the Instant Savings App, and the program's success in promoting energy efficiency education and Efficiency Nova Scotia.
APPENDIX III INTERVIEW GUIDE WITH RETAILER PARTNERS Hello, may I please speak with? INTRODUCTION Efficiency Nova Scotia Corporation for the Instant Savings Program. Hello, my name is, from Corporate Research Associates Inc. I am calling on...
AI summary This document is an interview guide for retailer partners, focusing on the Instant Savings Program managed by Efficiency Nova Scotia Corporation. It includes an introduction and identification and screening section for respondents.
SECTION V – VERIFICATION OF PRODUCTS FROM DATABASE V1. and validate the information with the interviewee. From the database, check the products that received the program discount for each campaign April-May Campaign October-November Campai...
AI summary This section outlines the verification process for products that received program discounts during specific campaigns, focusing on regular ENERGY STAR CFLs. It includes questions about sales volume, campaign impact, and the effect of discounts on sales.
C2a. By what percentage do you estimate the number of regular Energy Star CFL bulbs sold in your store would have been lower during the April-May campaign if the discount had not been available? RECORD PERCENTAGE ___% - C6. What influence...
AI summary The text asks about the impact of the Instant Savings program on CFL sales, including the percentage of sales outside the spring campaign that can be attributed to the program. It also inquires about the program's influence on salespeople's knowledge, product variety, and customer awareness.
C8a. With Canada's minimum energy performance standards for 60-watt and 40-watt incandescent light bulbs coming into force at the end of the year, do you still stock and sell these types of lights? Yes [GO TO C8b] No [GO TO C8c] C8b. When...
AI summary The text discusses the impact of Canada's minimum energy performance standards for incandescent light bulbs on retail sales, and whether ENSC's Instant Savings program has influenced these sales. It also addresses the availability of 60-watt and 40-watt incandescent bulbs post-implementation of the standards.
ASK IF ENERGY STAR LED BULBS WERE DISCOUNTED THROUGH THE PROGRAM – AND DURING WHICH CAMPAIGN(S) L1. I now have a few questions about your sales of Energy Star LED bulbs. By Energy Star LED bulbs, we refer to Energy Star LED screw-in bulbs...
AI summary The text asks whether Energy Star LED bulbs were discounted through the program and during which campaign(s), specifically referring to Energy Star LED screw-in bulbs and recessed downlights.
for each of the spring and fall campaigns this year and for 2014 overall, in number of units. a. According to our information, you soldEnergy Star LED bulbs DURING the spring campaign (April-May)? Is this accurate? Yes No - Record Sales: b...
AI summary The document seeks to determine the sales volume of ENERGY STAR LED bulbs during the spring and fall campaigns in 2014, including the impact of discount programs on sales. It asks about sales numbers, estimated percentages, and the influence of the discount on sales performance.
SECTION S – SATISFACTION WITH ENSC'S INSTANT SAVINGS PROGRAM For the last part of our discussion today, I will ask you questions on your satisfaction with different aspects of Efficiency Nova Scotia's Instant Savings on Energy Efficient Pr...
AI summary This section focuses on assessing satisfaction with Efficiency Nova Scotia's Instant Savings program, which provides immediate savings on energy-efficient products.
APPENDIX IV IN-STORE VISIT PROTOCOL Spring Visit Report Store Name: Address: Date of Visit: Eligible Products $3 - Energy Star Regular CFLs (multipacks of 2 or more) $3 - Energy Star Specialty CFLs (single or double packs) $5 - Energy Star...
AI summary This appendix outlines an in-store visit protocol that includes a list of eligible products and their corresponding rebate amounts for energy-efficient items such as LED bulbs, thermostats, and refrigerators.
In the table below, please check off the items which apply to your product. Product Purchase Situation Product to purchase: Instant rebate received directly at the counter upon presentation of the product to purchase and Walmart) Instant r...
AI summary The text presents a table for evaluating promotional displays related to product purchases, focusing on rebate receipt processes and customer experiences at different retailers. It includes fields for checking off relevant situations and describing any problems encountered during purchase.
Home Depot Promotional Lighting Controls Thermostats Appliances/Clotheslines Material Yes No No. Yes No No. Yes No No. Yes No No. Shelf Talkers Posters Handle Hangers Stickers Bin Violators Coupons Manual Signs Comments: Home Hardware Prom...
AI summary The text presents tables detailing promotional materials and signage related to various product categories such as lighting, controls, thermostats, and appliances at Home Depot and Home Hardware locations. The tables indicate the presence or absence of items like shelf talkers, posters, stickers, coupons, and manual signs.
In the table below, please indicate by using Yes/No for each observation whether the products eligible for rebates were easily identified. The products are located at eye level on the shelf. Yes No Indicate the percentage of available prod...
AI summary The text presents a table asking whether eligible rebate products are easily identifiable, including questions about product placement, shopper ability to identify products, salesperson assistance, and rebate awareness methods.
Fall Visit Report Store Name: Address: Date of Visit: Eligible Products $3 – Energy Star LED lights (Aline, GU10, Candle/Chandelier) $5 – Energy Star LED lights (PAR, MR and BR) $8 – Energy Star LED light bulbs (packs of 2 or more) $15 – E...
AI summary The document outlines eligible products and their respective rebate amounts for energy-efficient upgrades, including LED lights, thermostats, and refrigerators, under a program offering financial incentives for Energy Star certified products.
Atlantic Superstore Lighting Promotional Material Yes No # Bin Violators Posters Stickers Manual Signs Comments: Home Depot Lighting Controls Thermostats Appliances Promotional Material Yes No # Yes No # Yes No # Yes No # Shelf Talkers Pos...
AI summary The document contains tables related to promotional materials and signage for lighting, controls, thermostats, and appliances at Atlantic Superstore and Home Depot. The tables include columns for the presence of promotional materials, bin violators, posters, stickers, manual signs, and comments, but no detailed information is provided.
Walmart Lighting Thermostats Promotional Material Yes No # Yes No # Bin Violators Posters Stickers Aisle Interrupter Coupons Comments: Observations
AI summary The document provides a table and observations related to Walmart's participation in energy efficiency initiatives, focusing on promotional materials and other tools related to lighting and thermostats. However, no detailed information or analysis is provided in the text.
Do not ask the following questions directly to the representative. Simply show interest in the product/event. In-Store Event Section of the Store where the Event Takes Place Location of the event (which section in the store). Is it a high...
AI summary This table outlines an in-store event related to energy efficiency programs, focusing on the location of the event, the information provided by representatives, and the visibility of the event through promotional materials. It includes questions about product rebates, rebate amounts, and other programs promoted by ENSC.
Knowledge of the Program and Products - 1. Are there rebates that apply to this type of product? - 2. What is the amount of the rebate? - 3. Is it the same amount for all products? - 4. Until when does the rebate apply? - 5. (If salesperso...
AI summary This section outlines a series of questions related to rebate programs for energy-efficient products, focusing on eligibility, rebate amounts, duration, and similarity across products. It also references the Instant Savings program and Efficiency Nova Scotia (ENSC).
INTRODUCTION AND ELIGIBILITY Hello, my name is _____and I am with Corporate Research Associates, and we are performing the evaluation of the Instant Savings program provided by Efficiency Nova Scotia Corporation. We are gathering informati...
AI summary This text outlines the introduction and eligibility criteria for a survey evaluating the Instant Savings program by Efficiency Nova Scotia Corporation. The survey gathers information from customers who purchased energy-efficient light bulbs (CFLs and LEDs) and asks about purchase details and willingness to participate.
Awareness of Program and Efficiency Nova Scotia (AW Series) - AW1. Have you ever heard of the Efficiency Nova Scotia program which offers instant savings at the cash register for the purchase of energy-efficient products such as CFLs or L-...
AI summary This section of the proceeding document asks respondents about their awareness of the Efficiency Nova Scotia program and how they learned about it. It includes questions about whether they have heard of the program and the methods through which they became aware of it.
6. (Facebook/Social Media) 7. (Internet in general) 8. (Through an Efficiency Nova Scotia representative during an in-store customer engagement event) 9. (Friends/Word of Mouth) 96. (Other SPECIFY:) 98. (Don't Know) 99. (Refused) [ASK IF A...
AI summary The text presents a survey questionnaire focusing on customer awareness and behavior related to discounts on compact fluorescent lamps (CFLs) in retail stores. It includes questions about how customers learned about the discount and whether it influenced their purchasing decisions.
- FR4. If the discount had NOT been offered, when would you have purchased the CFLs that you purchased today? Would it have been…? [CODE ONE ONLY] - 1. Definitely today - 2. Probably today - 3. Probably at a later date - 4. Definitely at a...
AI summary The text contains survey questions related to consumer behavior regarding the purchase of energy-efficient lighting products, specifically CFLs and L-E-Ds, and the influence of discounts offered by Efficiency Nova Scotia on these purchases.
NOT AWARE OF THE DISCOUNT (FR0aa=2, DK, REF)] I just want to make sure I understand - You did not know about the discount on specific packages of L-E-Ds before paying at the register? [CODE ONE ONLY] - 1. Yes, I knew about the discount - 2...
AI summary The text is a survey question set aimed at understanding customer awareness and decision-making related to discounts on LED purchases. It includes questions about awareness, how customers learned about the discount, and whether the discount influenced their purchase decision.
FR41. If the discount had NOT been offered, when would you have purchased the L-E-Ds that you purchased today? Would it have been…? [CODE ONE ONLY] - 1. Definitely today - 2. Probably today - 3. Probably at a later date - 4. Definitely at...
AI summary The text contains survey questions aimed at assessing the impact of a discount offered by Efficiency Nova Scotia on customers' decisions to purchase L-E-Ds. Respondents are asked about their purchase timing and quantity without the discount, as well as the level of influence the discount had on their decision.
VOLUNTEERED - 97. (Skipped) [GO TO PR3] - 98. (Don't Know) [GO TO PR3] - 99. (Refused) [GO TO PR3] PR2. [ASK IF PR1 = 1] What are those products? Any others? [DO NOT READ RESPONSES – CODE AS MANY AS APPLY] - 1. (Regular or specialty CFLs)...
AI summary The text outlines a survey process related to energy efficiency products, including questions about product types, purchase intentions, and additional products respondents would like to see rebated through the Instant Savings program.
Introduction and Eligibility Hello, my name is _____and I am with Corporate Research Associates, and we are performing the evaluation of the Instant Savings program provided by Efficiency Nova Scotia Corporation. We are gathering informati...
AI summary This text outlines a survey conducted by Corporate Research Associates on behalf of Efficiency Nova Scotia Corporation to evaluate the Instant Savings program. The survey targets customers who purchased L-E-D energy-efficient lights and asks about purchase details and willingness to participate in the survey.
Purchase (P Series) - P1. Are there any L-E-Ds currently installed in your home? CODE ONE ONLY - 1. Yes - 2. No - 98. (Don't Know) - 99. (Refused) - P2_LED. How many L-E-Ds did you purchase today? [ENTER THE NUMBER OF BULBS NOT PACKAGES. P...
AI summary The text outlines a survey questionnaire focusing on the purchase of L-E-D bulbs, including questions about current installation, number purchased, and methods used to select the correct wattage. It includes response options and procedural instructions for handling various responses.
FR41. If the discount had NOT been offered, when would you have purchased the L-E-Ds that you purchased today? Would it have been…? [CODE ONE ONLY] - 1. Definitely today - 2. Probably today - 3. Probably at a later date - 4. Definitely at...
AI summary The text presents survey questions aimed at assessing the impact of a discount on LED bulb purchases, including whether the discount influenced the timing of purchase, the quantity purchased, and the type of bulb chosen. The questions are part of a customer survey related to energy efficiency programs.
CS1. How did you find out about this program? Sources of 2012 2013 2014 Awareness Overall CFL Purch. LED Lamp Purch. Overall CFL Purch. LED Lamp Purch. Overall CFL Purch. LED Lamp Purch. Sample Size 91 51 35 199 36 159 231 32 203 Total Adv...
AI summary The text presents data on how participants became aware of a program, specifically focusing on the sources of awareness for CFL and LED lamp purchases between 2012 and 2014. It includes statistics on various awareness channels such as advertising, in-store promotions, word of mouth, and ENSC representatives.
Discount 2012 2013 2014 Awareness Overall CFL Purch. LED Lamp Purch. Overall CFL Purch. LED Lamp Purch. Overall CFL Purch. LED Lamp Purch. Sample Size 164 99 65 241 44 91 294 43 251 Yes, was aware of discount before paying 76% 70% 85% 93%...
AI summary The table shows the awareness of discounts among customers who purchased CFLs and LED lamps in 2012, 2013, and 2014. A majority of respondents were aware of the discount before making a purchase, with higher awareness rates for LED lamp purchases compared to CFL purchases.
FR0c/FR0cc. Did you see the stickers, shelf signs or posters in the light bulbs section of the store promoting the discount offered on L-E-Ds? In-store 2012 2013 2014 Promotion Awareness Overall CFL Purch. LED Lamp Purch. Overall CFL Purch...
AI summary The text asks if stickers, shelf signs, or posters promoting discounts on L-E-Ds were seen in the light bulbs section of the store. It includes a table showing awareness of these promotions across different years and product types, with high percentages of respondents indicating they saw the promotional materials.
\ \ Base: Respondents who purchased LED lamps on the day of the survey \ \ Sample size lower than full base due to programming change AW1. Have you ever heard of the Efficiency Nova Scotia program which offers instant savings at the cash r...
AI summary The text discusses a survey question regarding awareness of the Efficiency Nova Scotia program, which offers instant savings for energy-efficient product purchases. It includes a note about the sample size and a reference to a chart.
AW4. Have you or someone from your household ever participated in one or more of Efficiency Nova Scotia Corporation's energy efficiency programs? 2014 Previous Participation in ENSC Programs Overall (LED Only) Sample Size 162 Yes 43% No 51...
AI summary The question asks if respondents or someone in their household has participated in Efficiency Nova Scotia Corporation's energy efficiency programs. The data shows 43% of respondents answered 'yes,' 51% 'no,' and 6% 'don't know,' based on a sample size of 162 respondents who heard of ENSC during the fall interview period.
AW5. Which energy efficiency program(s) from Efficiency Nova Scotia Corporation have you participated in? 2014 ENSC Programs Participated in Previously Overall (LED only) Sample Size 70 Lighting/Light bulb replacement/exchange 31% Energy a...
AI summary The text asks respondents about their participation in Efficiency Nova Scotia Corporation (ENSC) energy efficiency programs in 2014, with data showing the percentage of participants in various programs. It also asks about the year they participated in these programs, with responses distributed across years from 2010 to 2014.
I1. Did you purchase either CFLs or L-E-Ds today? CFLs/LED Lamps Purchased 2012 2013 2014 Sample Size 164 241 294 CFLs only 59% 18% 13% LED lamps only 37% 79% 85% Both 4% 2% 2% P2. How many CFLs/LEDs did you purchase today? 2012 2013 2014...
AI summary The document presents data on the purchase of CFLs and LED lamps from 2012 to 2014, showing a shift from CFLs to LED lamps over time. It includes sample sizes and the number of lamps purchased in different ranges.
P4. When you purchase L-E-Ds to replace regular incandescent or halogen light bulbs, on what do you usually rely to select the right wattage for your CFLs/L-E-Ds? 2014 Determining Wattage of CFLs and LEDs Overall (%) CFL Purchasers (%) LED...
AI summary The document asks respondents about how they determine the correct wattage for LED and CFL bulbs when replacing incandescent or halogen bulbs. It provides data on methods used, such as relying on package guidelines, consulting salespeople, or using conversion rules. The data is segmented by respondents who purchased CFLs, LED lamps, or both.
FR7. How influential was the discount offered by Efficiency Nova Scotia on your decision to purchase the CFLs/L-E-Ds that you purchased today? Please give your answer on a scale of 0 to 10, where 0 indicates the discount 'had no influence...
AI summary The question asks about the influence of Efficiency Nova Scotia's discount on the purchase of CFLs/L-EDs, using a scale from 0 to 10.
Importance of Discount 2012 2013 2014 in Influencing Decision to Install Energy efficient Products CFL LED Lamp Purchasers Purchasers CFL Purchasers LED Lamp Purchasers CFL Purchasers LED Lamp Purchaser s Sample Size 68 55 39 100 37 249 Me...
AI summary The text presents data from 2012 to 2014 about the importance of discounts in influencing purchase decisions for energy-efficient products like CFLs and LED lamps. It also includes survey results on awareness of other discounted energy efficiency products through the Instant Savings program.
PR2. What are those products? Other Discounted Products 2012 2013 2014 Sample Size 31 90 99 Refrigerators (no efficiency level specified) - 38% 30% Programmable thermostats 29% 38% 27% Power bars or smart strips 19% 20% 25% Regular or spec...
AI summary The text presents data on the adoption of energy efficiency products in Nova Scotia from 2012 to 2014, highlighting the percentage of respondents who purchased or planned to purchase various products such as refrigerators, thermostats, and LED lamps. It also includes statistics on purchase intentions for these products in 2013 and 2014.
Which Products Should Be Discounted 2012 2013 2014 Sample Size 73 103 119 Appliances 30% 31% 28% Heat pumps 12% 31% 24% Solar panels/products 5% 3% 8% Water heater/Tankless water heater 8% 9% 7% Air conditioners - - 7% Heating systems - -...
AI summary The table shows the percentage of respondents who selected various products for discounting in 2012, 2013, and 2014. Appliances, heat pumps, and insulation were among the most frequently mentioned products, while solar panels and water-saving devices were less commonly selected.
\ \ & quot;Don't know", "Refused", and "None/No others" removed from calculations \ \ \ Base: Among those who would like to see other energy efficiency products rebated through Instant Savings
AI summary This text presents a statistical summary related to energy efficiency programs, specifically focusing on Instant Savings. It notes that responses such as 'Don't know', 'Refused', and 'None/No others' have been excluded from calculations, and it references a base group interested in rebating other energy efficiency products through the program.
D10. Gender. 2012 2013 2014 Gender Overall (%) CFL Purch. (%) LED Purch. (%) Both CFL/LED Purch. (#) Overall (%) CFL Purch. (%) LED Purch. (%) Both CFL/LED Purch. (#) Overall (%) CFL Purch. (%) LED Purch. (%) Both CFL/LED Purch. (#) Sample...
AI summary The table presents gender distribution data across various years for participants in a program, with percentages and numbers for males and females, including breakdowns for CFL and LED purchases. The sample sizes vary annually, and there is a note about incomplete data in 2013 due to interviewer error.
FR0a. Before paying at the cash register, were you aware that a discount was offered on the purchase of [CFLs or LEDs]? IF 1. Yes : GO TO FR1 IF 2 OR 9 : Ask FR0b FR0b. I just want to make sure I understand - You did not know about the dis...
AI summary The document outlines a survey process to assess customer awareness and the influence of discounts on the purchase of [CFLs or LEDs]. It includes branching logic based on responses and calculates scores to determine free-ridership, with considerations for inconsistencies in responses.
APPENDIX VIII INTERNAL SPILLOVER METHODOLOGY The retailer interviews were used to estimate the level of spillover by measuring the market effects attributable to the program for two eligible products: CFLs and LED lamps. Instant Savings di...
AI summary This appendix discusses the methodology used to estimate internal spillover effects from the Instant Savings program by analyzing retailer interviews and market effects on sales of energy-efficient products like CFLs and LED lamps, even outside of campaign periods.
CFL C1a. According to our information , you sold regular ENERGY STAR CFLs DURING the spring campaign (April-May)? Is this accurate? IF Yes: CONTINUE IF No: RECORD SALES CFLs Sales during Spring Campaign : ME1 C1b. Roughly what percentage o...
AI summary The text presents a series of questions and calculations related to the sales of ENERGY STAR CFLs during the spring campaign and the program's attribution level. It includes metrics for sales during and outside the campaign and calculates market effects based on these figures.
LED L1a. According to our information, you sold regular IF Yes: CONTINUE ENERGY STAR LEDs DURING the spring campaign (April-May)? Is this IF No: RECORD SALES accurate? LEDs Sales during Spring Campaign: ME1 L1b. Based on the information yo...
AI summary The text is a form used to collect information about LED bulb sales during specific campaigns, including spring and fall periods, and to estimate program attribution levels. It includes questions about sales figures, percentages, and the impact of a program on sales outside of these campaigns.
Program Overview HEA encourages homeowners in Nova Scotia to improve the energy efficiency and comfort of their homes. HEA focuses on building envelope insulation measures, such as draft proofing, installation of ENERGY STAR-qualified wind...
AI summary The Home Energy Assessment (HEA) program in Nova Scotia encourages homeowners to improve home energy efficiency through insulation measures and financial incentives. The program includes pre- and post-retrofit assessments and is funded by electricity ratepayers for electricity-related measures and taxpayers for other fuel-related measures.
Based on these parameters, the net electrical energy savings for 2014 are estimated at 5.785 GWh and peak demand savings at 1.423 MW at the generator.
AI summary The document estimates net electrical energy savings for 2014 at 5.785 GWh and peak demand savings at 1.423 MW at the generator based on specified parameters.
Table 2: Validated Savings at the Generator Gross Savings NTGR Net Savings Energy Savings Validated Savings 4.943 GWh 0.75 3.707 GWh Unconverted D Study Validated Savings 2.078 GWh - 2.078 GWh Total Validated Energy Savings 7.020 GWh - 5.7...
AI summary Table 2 presents validated energy and peak demand savings at the generator level, including gross and net savings after applying a net-to-gross ratio (NTGR) of 0.75. Total validated energy savings amount to 7.020 GWh, with net savings of 5.785 GWh. Total validated peak demand savings are 1.727 MW, with net savings of 1.423 MW.
2 METHODOLOGY This section presents the Econoler team and the methodology used to evaluate HEA.
AI summary This section introduces the Econoler team and outlines the methodology used to evaluate Home Energy Assessments (HEA).
2.2 Methodology Description In 2014, a full-scale evaluation of HEA was not carried out. As part of the 2014 evaluation, the Econoler team validated ENSC's tracked savings, verified that the evaluation parameters—such as the billing calibr...
AI summary In 2014, ENSC conducted an evaluation of the Home Energy Assessment (HEA) program, validating tracked savings, reassessing free-ridership and internal spillover, and analyzing savings from former participants. A telephone survey was conducted by CRA to gather participant feedback on HEA and ENSC.
3 VALIDATED SAVINGS This section presents the gross and net savings for HEA in 2014.
AI summary This section presents the gross and net savings for HEA in 2014.
3.2.2 Internal Spillover The annual participant survey was also used to assess internal spillover, which can occur when participants, following their previous participation, implement additional energy efficiency measures that were recomme...
AI summary The annual participant survey identified internal spillover, where participants implemented additional energy efficiency measures after their initial assessment. The internal spillover effect factor was six percent in 2014, higher than previous years. Certified energy advisors (CEAs) continue to recommend these measures, and more participants reported taking additional actions post-assessment.
4 UNCONVERTED D STUDY SAVINGS In 2013, many participants did not complete the E assessment. The partner's interviews from the 2013 process evaluation showed that the main reason for this was the length of time to complete the E assessment...
AI summary The document discusses the 2013 Unconverted D Study Savings, focusing on participants who did not complete the E assessment. It outlines the methodology used to calculate energy savings from unconverted participants, including survey results, the influence of energy assessments, and the calculation of net energy and peak demand savings.
Table 6: Unconverted D Study Electrical Savings Unconverted D Study Electrical Savings Total Number of Unconverted D Study Participants 3,088 Ratio of Unconverted D Study Participants Who Implemented at Least One Measure 73% Total Number o...
AI summary Table 6 presents data on electrical savings from the Unconverted D Study, including participant numbers, implementation rates, average savings per participant, and energy and peak demand savings at both the meter and generator levels.
5 OVERALL HEA RESULTS The table below summarizes the overall results for HEA. With combined net savings generated from both validated savings and the unconverted D study savings, the total energy and peak demand savings amounted to 5.785 G...
AI summary The overall HEA results show that combined net savings from validated and unconverted D study savings totaled 5.785 GWh in energy and 1.423 MW in peak demand.
INTRODUCTION Hello, my name is _________ and I am with CRA, Corporate Research Associates, a Halifax-based survey research company. We are performing an evaluation of energy efficiency programs and services provided by Efficiency Nova Scot...
AI summary The introduction outlines a survey conducted by Corporate Research Associates on behalf of Efficiency Nova Scotia Corporation to evaluate the Home Energy Assessment program. The survey aims to gather feedback from participants to improve the program and takes approximately ten minutes to complete.
Verification and Recall (Series V) - V1. We understand you participated in the Home Energy Assessment program. Is that correct? - 1. Yes [CONTINUE] - 2. No [PROMPT: "Are you sure? Someone would have come to your house to evaluate the energ...
AI summary This section of the document is part of a verification and recall process related to participation in the Home Energy Assessment program. It includes a series of prompts and instructions for respondents to confirm their involvement in the program, including potential follow-up questions if they are unsure.
PROMPT WORKS; IF RESPONDENT STILL SAYS DON'T KNOW: "Is there someone else in the household who would know about having participated in the Home Energy 1. 2. Assessment program?"] Yes [ASK TO SPEAK TO THEM AND REPEAT INTRODUCTION] No [THANK...
AI summary The text provides a prompt for surveying participants of the Home Energy Assessment program, asking how they first learned about it. It includes instructions for handling responses and offers an option to reschedule if the participant refuses to participate.
- 1. Media advertising - 2. Contacted directly by Efficiency Nova Scotia - 3. Through a third party contractor or service provider - 4. Efficiency Nova Scotia website - 5. Facebook or other social media - 6. Word of mouth - 97. (Other [SPE...
AI summary The text outlines various methods by which individuals may have learned about the Home Energy Assessment program, including media advertising, direct contact with Efficiency Nova Scotia, and social media. It also includes a question about direct contact with Efficiency Nova Scotia employees regarding the program.
Verification of Actions Taken (VR Series) VR1. I am going to read you a list of upgrades that may have been recommended by the Energy Advisor for your home. For each one, can you please tell me if that upgrade was recommended for your home...
AI summary The VR1 section asks respondents to confirm whether specific home energy upgrades were recommended by an Energy Advisor. The list includes various insulation, heating, and water heating measures.
[ASK VR2A-B IF ANY ITEM IN VR1A THRU S=1 ("YES, RECOMMENDED")] - VR2a. IF MORE THAN ONE ITEM IN VR1a-s=YES, READ: Through the Home Energy Assessment program, have you implemented at least one, all or none of the energy efficiency recommend...
AI summary The text presents a series of questions related to the Home Energy Assessment program, specifically asking participants whether they implemented energy efficiency recommendations and received rebates or incentives for upgrades. The questions are structured to determine the extent of implementation, whether partial or full.
[ASK VR3 IF VR2A=1 ("YES, IMPLEMENTED AT LEAST ONE UPGRADE") - VR3. Which of the following recommendations have you implemented under the Home Energy Assessment program? [ASK FOR EACH ITEM IN VR1a thru p = 1 - [1 = YES, IMPLEMENTED, 2 = NO...
AI summary The document asks VR3 to indicate which recommendations from the Home Energy Assessment program have been implemented, listing various energy efficiency measures such as heat pumps, insulation, and water heating systems.
Spillover (SO Series) SKIP PATTERN APPLIES TO ENTIRE SO SECTION: ASK IF VR2a=3 ("No, have not implemented any upgrades" OR IF VR2b=2 ("No, not implemented the upgrade") OR IF ANY POSED ITEM IN VR3a thru p=2 "No, not implemented" You mentio...
AI summary The text outlines a survey process related to the Home Energy Assessment program, asking participants if they implemented recommended energy efficiency upgrades after participating, which upgrades were implemented, and whether they received financing or rebates for those upgrades. It also seeks to assess the influence of the program on participants' decisions.
[IF FR1=YES, THEN ASK:] - FR1a. I just want to make sure I understand Before you decided to participate in the Home Energy Assessment program, you had already made the decision to implement the energy efficiency upgrades you implemented th...
AI summary The text outlines a survey question related to participation in the Home Energy Assessment program, asking respondents whether they had already decided to implement energy efficiency upgrades prior to participating in the program. It also asks about the likelihood of taking certain actions in the absence of the program.
FR2a implemented exactly the same quantity of energy efficiency upgrades that you implemented through the Home Energy Assessment program? Response 98 Don't Know 99 Refused material or product? FR2b implemented standard equipment, material...
AI summary The text asks whether FR2a implemented the same number of energy efficiency upgrades as the Home Energy Assessment program and whether standard equipment was used instead of energy-efficient equipment. The response options include 'Don't Know' and 'Refused'.
FR2c implemented the exact same energy efficiency upgrades that you implemented through the Home Energy Assessment program, but at a later date? Response 98 Don't Know 99 Refused [IF FR2c > 5, THEN ASK:] 1. implemented these upgrades? RESP...
AI summary The text outlines survey questions related to the Home Energy Assessment program and its impact on the timing of energy efficiency upgrades. It also asks respondents about their willingness to pay for upgrades without rebates and the importance of the program in their decision-making process.
Factor (READ AND RANDOMIZE) Responses a. The program incentive Response 98 Don't Know 99 Refused b. Information or advice provided by the program Response 98 Don't Know 99 Refused c. Information or advice from the energy audit Response 98...
AI summary The text presents a table with factors related to a program and responses, including categories such as program incentives, information provided, and previous experience with energy assessment programs. It also references demographic characteristics, indicating the data collection context.
CS1. How did you first learn about this program? Sources of Awareness 2012 2013 2014 Sample Size 80 101 100 Word of mouth 40% 33% 43% Media advertising - - 19% The Internet 15% 6% 9% ENSC website 1% 6% 4% Home show - 6% 4% Facebook or othe...
AI summary The table outlines how participants first learned about the program from 2012 to 2014, with word of mouth being the most common source, followed by media advertising and the internet. Other sources include the ENSC website, home shows, and social media, with varying levels of usage over the years.
VR2a/VR2b. Through the Home Energy Assessment program, have you implemented at least one, all or none of the energy efficiency recommendations, meaning that you received a rebate or incentive for installing the upgrades?
AI summary The question asks whether participants in the Home Energy Assessment program have implemented energy efficiency recommendations, specifically whether they received a rebate or incentive for installing the upgrades.
Recommended Energy Efficiency Measures Implemented 2012 2013 2014 Sample Size 79 101 100 Implemented at least one upgrade 65% 77% 64% Implemented all of the upgrades 32% 19% 34% Did not implement any upgrades - 2% 1% Don't know 4% 2% 1% Ba...
AI summary The table shows the percentage of respondents who implemented energy efficiency upgrades in 2012, 2013, and 2014. The data indicates that while the majority implemented at least one upgrade, the percentage of those who implemented all recommended upgrades decreased in 2013 before increasing slightly in 2014.
- VR3. Which of the following recommendations have you implemented under the Home Energy Assessment program? 2012 2013 2014 Measures Recom mended Imple mented Recom mended Imple mented Recom mended Imple mented Sample Size 80 80 101 101 10...
AI summary The Home Energy Assessment program's implementation rates for various energy efficiency measures are presented in a table, showing the recommended and implemented percentages for each measure across the years 2012, 2013, and 2014.
VR1/V3. Measure uptake calculated as the percentage of measures implemented by measures recommended. 2012 2013 2014 Proposed Energy Efficiency Measure Uptake Measure Uptake Measure Uptake Measure Uptake Sample Size 80 101 100 Draft proofin...
AI summary The document presents data on the uptake of energy efficiency measures from 2012 to 2014, showing varying percentages of implementation across different measures. It also includes survey results about contact with Efficiency Nova Scotia employees regarding the Home Energy Assessment program.
S10. Thinking of when your post-retrofit assessment was conducted by the energy advisor, how long, in days, was it before you received your rebate? Length of Time to Receive Rebate 2014 Sample Size 60 7-9 days 2% 10-19 days 10% 20-29 days...
AI summary The text discusses the time it took for participants to receive rebates after a post-retrofit assessment and the importance of various factors in their decision to implement energy efficiency upgrades. Data is presented for 2014, showing the distribution of rebate receipt times and average importance ratings for different program aspects.
MEAN VALUE OF: (FR2a; FR2b) FR1. Before participating in HEA, did you have plans to implement the specific energy efficiency upgrades that were implemented through the program? IF 1. Yes: Use FR1a IF 2. No OR 99: FR1 = 0% FR1a. I just to m...
AI summary The text outlines survey questions related to customer participation in the Home Energy Assessment (HEA) program, specifically focusing on pre-program decisions to implement energy efficiency upgrades and the influence of rebates from Efficiency Nova Scotia Corporation (ENSC).
100% -[FR4_P/(FR4_P+FR4_NP)] FR2c. If you had not participated in HEA, what is the likelihood that you would have implemented the exactly same energy efficiency upgrades that you implemented through program but at a later date? (Scale 0 to...
AI summary This section of the regulatory proceeding document asks respondents about the likelihood of implementing energy efficiency upgrades without the Home Energy Assistance (HEA) program and the potential delay in implementation if they had not participated in HEA. The responses are quantified on a scale from 0 to 10 and further categorized into time frames.
The figure below illustrates the methodology used to calculate the internal spillover level. INTRO. SO Section asked to participants who have not implemented all the energy efficiency upgrades recommended in their assessment report through...
AI summary The text outlines a methodology for calculating internal spillover levels based on participant responses regarding the implementation of energy efficiency upgrades post-HEA (Home Energy Assessment) and their influence on subsequent actions.
Program Component Overview Efficiency Nova Scotia Corporation's (ENSC) Green Heat encourages homeowners to reduce electricity use in homes for space-heating or to supplement it with another energy source. Green Heat focuses on heating syst...
AI summary Efficiency Nova Scotia Corporation's Green Heat program encourages homeowners to reduce electricity use for space heating by offering rebates and zero-interest financing for eligible heating systems, including wood and pellet stoves, geothermal heat pumps, and air-to-water heat pumps. The program aimed for 1.3 GWh of electricity savings and 0.4 MW of peak demand savings in 2014.
Participant Satisfaction Satisfaction with Green Heat was very high among participants in 2014. Indeed, nearly all the respondents indicated their satisfaction with Green Heat overall, as well as with its various aspects, such as the equip...
AI summary Participant satisfaction with Green Heat was very high in 2014, with nearly all respondents expressing satisfaction with the program and its aspects, including ENSC's performance and responsiveness. Few recommendations for improvement were provided, and all participants were likely to recommend the program to others.
Challenges and Barriers In 2014, the proportion of Green Heat participants experiencing challenges or barriers in installing their new equipment or new energy source was the same as that in 2013. Two in 10 participants claimed having encou...
AI summary In 2014, 20% of Green Heat participants faced challenges or barriers, primarily related to installation and payback requirements. The main challenge in 2013 was meeting a shortened installation deadline, which was later extended to six months in 2014, leading to positive participant feedback.
Table 2: Comparison of Tracked and Evaluated Savings at the Generator Initial Gross Savings NTGR Net Savings Energy Savings Tracked Savings from ENSC 2.393 GWh 0.66 1.580 GWh Evaluation Results 2.299 GWh 0.64 1.472 GWh Peak Demand Savings...
AI summary Table 2 compares tracked and evaluated energy and peak demand savings at the generator level. Net savings are seven percent lower than tracked savings, attributed to a lower NTGR, reduced unitary savings for geothermal heat pumps, and adjustments for heat pumps used as primary heating systems before conversion.
Recommendations Overall, the Econoler team believes that Green Heat is operating in a satisfactory manner. In addition to the general recommendations presented for all the ENSC program components in the overall evaluation executive summary...
AI summary The Econoler team recommends optimizing Green Heat's performance by adjusting initial system efficiency assumptions and improving pre-screening processes to ensure accurate information about the initial heating system type. These changes aim to enhance eligibility criteria and improve energy savings calculations.
1 PROGRAM DESCRIPTION Green Heat targets existing homes in Nova Scotia that primarily use electricity for heating. The goal of Green Heat is to provide financial incentives to homeowners to encourage them to reduce electricity use in homes...
AI summary The Green Heat program provides financial incentives to Nova Scotia homeowners to reduce electricity use for heating or supplement it with renewable energy sources. Participants can choose between rebates or zero-interest financing for eligible heating equipment. The program is managed by Efficiency Nova Scotia Corporation and funded through electricity ratepayer funds. The 2014 strategy focused on close retailer communication and trade show participation.
3 PROCESS EVALUATION This section presents the findings of the 2014 Green Heat process evaluation, which has been carried out on the basis of the information gathered from the Green Heat documentation and tracking system, as well as an int...
AI summary This section presents the findings of the 2014 Green Heat process evaluation, based on information from the Green Heat documentation and tracking system, an interview with the Program Manager, and on-site visits.
Recommendation Status 2012 Recommendations 2012 GH-R1. Continue marketing efforts and outreach activities Implemented 2012 GH-R2. Consider reintroducing a rebate on ductless mini-split heat pumps for quality purposes Will not be implemente...
AI summary The document outlines several recommendations from 2012 and 2013 related to marketing efforts, rebate programs, and participant information enhancements. Most recommendations have been implemented, with a notable exception being the rebate on ductless mini-split heat pumps. ENSC has taken actions to address these recommendations.
3.3 Program Documentation and Design As part of the evaluation, the Evaluator analyzed the program documentation and worked together with the PM to improve and revise the program manual, the evaluation plan and the logic model, where appli...
AI summary The Evaluator worked with the Program Manager to revise program documentation, including the program manual, evaluation plan, and logic model for Green Heat. A project workflow checklist was developed and integrated into the Data Management System to ensure proper application processing and prevent missing information.
3.4 Tracking System In 2014, ENSC began to track Green Heat data using the demand-side management data system (DSMDS) and generate tracking reports (extracted directly from the DSMDS) for evaluation purposes. The DSMDS and the tracking rep...
AI summary In 2014, ENSC started using the DSMDS to track Green Heat data and generate tracking reports, replacing the 2013 Excel-based tracking sheet. The 2014 tracking report is an Excel workbook with four tabs containing different types of information.
Installed Systems The final tab in the tracking report contains a summary table of the equipment installed to date. The quantity of each equipment type was recorded and categorized in two groups, namely those that received financing and th...
AI summary The tracking report for installed systems provides a detailed summary of equipment installed, categorized by financing and rebate. The report is well-organized, but issues were identified, such as inaccuracies in unitary savings for heat pump projects and missing data like utility account numbers and backup heating sources. The Evaluator recommends improvements to data collection for future analysis.
3.5 On-site Visits Five on-site visits were carried out as part of 2014 Green Heat evaluation. These visits included an assessment of two wood stoves, one pellet stove, one central air source heat pump and one geothermal heat pump. The pur...
AI summary Five on-site visits were conducted as part of the 2014 Green Heat evaluation to confirm the installation and use of rebated heating equipment. The visits validated that the equipment was installed and in use, but identified discrepancies in the tracking system regarding the previous heating systems. Improvements to pre-screening and record-keeping are recommended.
4.1.1 Green Heat Awareness Participants found out about Green Heat in a number of ways, mainly through word of mouth, media advertising, in stores or on the ENSC website. [Table 5](#page-133-3) summarizes all the different sources of aware...
AI summary Participants learned about Green Heat primarily through word of mouth, media advertising, in stores, and on the ENSC website, as summarized in Table 5.
Table 5: Sources of Awareness Sources of Awareness 2012 2013 2014 Sample Size 34 70 53 Word of mouth 24% 21% 19% Media advertising 26% 20% 15% The store where new equipment was purchased 21% 7% 15% On the ENSC website 9% 20% 13% Through a...
AI summary Table 5 presents data on sources of awareness for energy efficiency programs from 2012 to 2014. It shows the percentage of respondents who became aware of programs through various channels, such as word of mouth, media advertising, and the ENSC website. The data highlights changing trends in awareness over time.
4.1.2 Motivations and Barriers to Participation The main reason for participating in Green Heat was to save on energy costs (with 68% having given this response as their most important motivation). Comfort is mentioned by one in 10, as wan...
AI summary The main motivation for participating in Green Heat was saving on energy costs, cited by 68% of respondents. Other motivations included comfort, replacing heating systems, and environmental concerns.
Table 6: Reasons for Participating 2012 2013 2014 Reasons for Participating Most Important Motivation Second Most Important Motivation Most Important Motivation Second Most Important Motivation Most Important Motivation Second Most Importa...
AI summary Table 6 presents survey data on the reasons participants cited for joining energy efficiency programs between 2012 and 2014. The primary motivation was saving on energy costs, with a consistent decline in percentage over the years. Other motivations include improving comfort, having a backup heating source, and environmental concerns, though these were less significant.
4.1.3 Green Heat Influence Survey respondents were asked questions about the influence of Green Heat on their decision to replace their heating system with another heating source. Similar to previous years, the rebate or financing was the...
AI summary Survey respondents indicated that rebate or financing was the most important factor in influencing their decision to replace heating systems, with information about Green Heat being modestly important and previous experience with ENSC or NSP programs being less important.
4.1.5 Participant Recommendations for Improvements Respondents were asked whether they had any recommendations to improve Green Heat. Less than two in 10 would like to see the rebate amount increased, while a similar number mentioned that...
AI summary Respondents provided recommendations for improving Green Heat, with less than two in 10 suggesting an increase in rebate amounts and a similar number advocating for better advertising. Table 11 summarizes these recommendations.
Table 11: Recommendations to Improve Green Heat Recommendations to Improve Green Heat 2012 2013 2014 Sample Size 75 70 53 Increase rebate amount 13% 21% 15% Advertise the program more or in a better way 8% 6% 13% Offer additional equipment...
AI summary Table 11 outlines recommendations for improving the Green Heat program based on survey data from 2012 to 2014. Key suggestions include increasing rebate amounts, improving advertising, offering more eligible equipment, and simplifying application processes. The majority of respondents did not provide specific recommendations.
5.1 Gross Savings The tracking report provided for 2014 shows a total of 235 participants (193 from the rebate option and 42 from the financing option), who had installed a total of 235 units. The following sections present the unitary sav...
AI summary The 2014 tracking report shows 235 participants who installed energy-efficient equipment through rebate and financing options. The report includes unitary savings values tracked by ENSC and a revision conducted by the Evaluator.
Tracked Savings [Table 12](#page-139-3) displays a detailed list of the eligible equipment and current unitary savings values (energy and peak demand) tracked by ENSC. These values come from the 2013 evaluation report.
AI summary Table 12 lists eligible equipment and their energy and peak demand savings values tracked by ENSC, based on the 2013 evaluation report.
Table 12: Tracked Unitary Savings Values Based on Literature Review Category of Equipment Tracked Energy Savings Value (kWh/year) Tracked Peak Demand Savings Value (kW) Wood Stoves 10,443 4.00 Pellet Stoves 8,959 4.00 Wood Furnace or Boile...
AI summary Table 12 presents tracked unitary savings values for various heating equipment based on a literature review, including energy savings in kWh/year and peak demand savings in kW for different types of wood and pellet stoves, furnaces, boilers, and heat pumps.
Table 15: Adjustment Ratio for Heat Pump as Initial Heating System New Equipment Adjustment Ratio for Energy Savings Adjustment Ratio for Peak Demand Savings Pellet Stoves 0.973 0.973 Geothermal Heat Pump 0.886 0.891 Central Ducted Heat Pu...
AI summary Table 15 presents adjustment ratios for energy and peak demand savings for different heating systems, including heat pumps. ENSC previously considered the same savings for participants with various initial heating systems, but heat pump users were ineligible unless their electricity consumption exceeded 21,000 kWh/year.
5.1.2 Revised Gross Savings The annual gross savings for each category of equipment installed through Green Heat are presented in [Table 16.](#page-145-1) These were calculated using the unitary savings values revised in this report. Overa...
AI summary The revised gross savings from Green Heat programs are detailed, showing 2.090 GWh in energy savings and 0.844 MW in peak demand savings at the meter. At the generator level, these figures increase to 2.299 GWh and 0.928 MW, factoring in Nova Scotia Power's residential line loss factor of 1.100.
Table 16: Evaluation Results – Revised Gross Energy and Peak Demand Savings Category of Product Wood Stove Pellet Stove Wood Furnace or Boiler Pellet Furnace or Boiler Central Ducted Heat Pump Geoth. Heat Pump Total Energy Savings Number o...
AI summary Table 16 presents evaluation results for revised gross energy and peak demand savings across various heating products, including wood and pellet stoves, furnaces, and heat pumps. It includes metrics such as number of units, unitary savings, adjustments for heat pump usage, and total energy and peak demand savings at both meter and generator levels.
Table 17: Evaluation Results – Revised Net Energy and Peak Demand Savings Category of Product Wood Stove Pellet Stove Wood Furnace or Boiler Pellet Furnace or Boiler Central Ducted Heat Pump Geoth. Heat Pump Total Energy Savings Total Gros...
AI summary Table 17 presents the evaluation results for revised net energy and peak demand savings across various heating products, including wood and pellet stoves, furnaces, and heat pumps. The table includes metrics such as total gross and net energy savings, line loss factors, and peak demand savings at both the meter and generator levels.
Table 18: Comparison of Tracked and Evaluated Savings at the Generator Initial Gross Savings NTGR Net Savings Energy Savings Tracked Savings from ENSC 2.393 GWh 0.66 1.580 GWh Evaluation Results 2.299 GWh 0.64 1.472 GWh Peak Demand Savings...
AI summary Table 18 compares tracked and evaluated energy and peak demand savings from the Efficiency Nova Scotia Corporation (ENSC). Evaluated net energy savings are 7% lower than tracked savings, with the Net-to-Gross Ratio (NTGR) also slightly lower than in the 2013 evaluation. The difference is attributed to reduced unitary savings for geothermal heat pumps and adjustments for heat pumps used as primary heating systems.
CONCLUSION The 2014 evaluation of Green Heat demonstrated that most of the recommendations made specifically for Green Heat in the last evaluations were implemented. The Evaluator commends ENSC on the efforts it made to improve and optimiz...
AI summary The 2014 evaluation of Green Heat highlighted successful implementation of past recommendations, improvements in marketing and data accuracy, and high participant satisfaction. However, participation slightly declined, and energy savings decreased compared to previous years. The evaluation also noted the impact of shifting focus to renewable fuel-based heating systems.
APPENDIX I 2014 RECOMMENDATIONS Sections Recommendations Executive Summary 1 Consider using an initial system efficiency other than 100 percent when the air source heat pump or the geothermal heat pump is used as the initial primary heatin...
AI summary The 2014 recommendations suggest that Efficiency Nova Scotia Corporation (ENSC) should consider using a lower initial system efficiency when heat pumps are the primary heating system, rather than assuming 100% efficiency. It also recommends removing the eligibility criterion requiring participants to have a total electricity consumption greater than 21,000 kWh/year before installation.
Awareness and Participation [P Series] - P2. Now I'm going to ask you to think back to when you decided to supplement your electric space heating or completely replace it with another heating source and participate in the Green Heat Progra...
AI summary The text outlines a survey conducted to understand participants' motivations and concerns regarding the Green Heat Program, focusing on reasons for switching heating systems, influencing factors, and potential concerns about program participation.
FR3. [IF REBATE] Efficiency Nova Scotia paid you $[INCENTIVE] for your new space heating system. If you had not received the rebate from Efficiency Nova Scotia, would you have made the same purchase? [IF FINANCING] Efficiency Nova Scotia p...
AI summary The document asks respondents whether they would have made the same purchase of a space heating system without the rebate or financing provided by Efficiency Nova Scotia. It also asks them to rate the importance of various factors influencing their decision to replace their heating system.
- P3. Were there any other reasons? 2012 2013 2014 Reasons for Participating Most Important Motivation Second Most Important Motivation Most Important Motivation Second Most Important Motivation Most Important Motivation Second Most Import...
AI summary The table presents survey data on the reasons for participating in energy efficiency programs from 2012 to 2014. The primary motivation for participation was saving on energy costs, with a significant decline in the percentage of respondents selecting this reason over the years. Other motivations included comfort, backup heating, and environmental concerns, but these were less frequently cited.
B2. What were those challenges or barriers? Specific Challenges Face in Installing New Equipment 2013 (#) 2014 (#) Sample Size 13 10 Problems with installation - 3 Energy-efficient equipment does not meet payback requirements 1 2 Paperwork...
AI summary The challenges faced in installing new energy-efficient equipment include issues with installation, paperwork, meeting deadlines, and finding qualified contractors. The importance of green heat programs, rebates, and information provided by salespeople was rated on a scale from 0 to 10, with program rebates and financing being the most important factors.
S1. Using a scale from 1 to 5, where 1='not at all satisfied' and 5='very satisfied', how would you rate your satisfaction with the Green Heat Program overall? Satisfaction with Overall Experience 2012 2013 2014 Sample Size 75 70 53 5 – Ve...
AI summary The Green Heat Program received high satisfaction ratings, with 77% to 80% of respondents indicating they were very satisfied. Reasons for dissatisfaction included eligibility requirements, the need to submit many documents, and the program being perceived as geared more towards inspectors/sellers.
CS5. Now, using the same 10 point scale, how satisfied are you with Efficiency Nova Scotia's overall performance in working with you? Satisfaction with Overall 20 012 2 2013 2 2014 Performance Sample Size Satisfied Sample Size Satisfied Sa...
AI summary The text presents survey results measuring satisfaction with Efficiency Nova Scotia's performance, including responsiveness, approval speed, and program value, across different years and sample sizes.
S10. Thinking of when you first contacted ENSC about the program, or ENSC contacted you, how long, in weeks, was it before you received your rebate? Length of Time to Receive Rebate 2014 Sample Size 33 2-3 weeks 27% 4-5 weeks 27% 6-11 week...
AI summary The text asks respondents about the time it took to receive a rebate after contacting Efficiency Nova Scotia Corporation (ENSC) and gathers recommendations for improving the Green Heat Program. The data shows varying response times and a range of suggestions for program improvements.
Table 1: Validated Savings at the Generator Initial Gross Savings NTGR Net Savings Energy Savings 2.311 GWh 1.00 2.311 GWh Peak Demand Savings 0.539 MW 1.00 0.539 MW
AI summary Table 1 presents validated savings at the generator, showing initial gross savings, net-to-gross ratio (NTGR), and net savings for energy and peak demand. Energy savings amount to 2.311 GWh, and peak demand savings are 0.539 MW, with an NTGR of 1.00 for both categories.
2 VALIDATED SAVINGS In 2014, a full-scale evaluation of LIH was not carried out. The evaluation of LIH involved not only substantiating the savings tracked by ENSC who used the parameters established in the 2013 evaluation, but also reasse...
AI summary In 2014, a full-scale evaluation of the Low Income Homeowner (LIH) program was not conducted. The evaluation of LIH involved verifying savings tracked by ENSC using parameters from the 2013 evaluation and reassessing key parameters such as EnerGuide point value, modelled energy consumption, and unitary savings. This section discusses the validation of gross and net savings for LIH.
2.1.1 Building Envelope Measures Using Savings per EnerGuide Point Increase In 2014, ENSC calculated the building envelope measures' savings for 109 LIH participants by applying an incremental savings coefficient per increased EnerGuide po...
AI summary In 2014, ENSC calculated building envelope measure savings for LIH participants using a savings per EnerGuide point method. A coefficient of 783 kWh was applied, and a 95.5% realization rate was used for participants who had not completed the E assessment. This method was reviewed as part of the 2014 evaluation.
Data Processing With regards to data, the Evaluator used the initial and final EnerGuide ratings and the modeled consumption values provided for 2013 LIH participants. More specifically, the Evaluator kept only those participants who met t...
AI summary The Evaluator processed data from 88 LIH participants using initial and final EnerGuide ratings and modeled consumption values. Participants had to meet specific criteria, including having both initial and final EnerGuide ratings, using 100% electrical heating, and showing an improved rating post-implementation. The analysis aimed to ensure a representative sample for evaluating savings per EnerGuide point.
EnerGuide Rating The data regarding the 88 participants selected by the Evaluator was used to analyze the average space heating energy savings per EnerGuide point by comparing D and E simulation results. Since the majority of EnerGuide rat...
AI summary The Evaluator analyzed data from 88 participants to determine average space heating energy savings per EnerGuide point by comparing D and E simulation results. The focus on space heating reductions improved precision by avoiding errors in base load and domestic water heating inputs. An average savings per EnerGuide point was calculated for each participant before determining an overall average.
Table 2: Calculation of Average Savings per EnerGuide Point Based on HOT2000 Data Description Values and Units Range of EnerGuide point increase per participant From 1 to 19 Range of space-heating savings per participant From 73 to 22,279...
AI summary Table 2 presents the calculation of average savings per EnerGuide point based on HOT2000 data, showing a range of savings from 73 to 22,279 kWh/year and an overall average of 1,001 kWh/year.
2.1.3 Prescriptive Measures' Savings In addition to the savings calculated for building envelope measures, ENSC calculated the unitary savings values for a set of prescriptive measures not taken into account by HOT2000 simulations.
AI summary ENSC calculated unitary savings values for prescriptive measures not considered by HOT2000 simulations, in addition to savings from building envelope measures.
Tracked Savings ENSC promoted the replacement of old refrigerators with more efficient models through LIH. For this appliance replacement measure, ENSC uses a unitary savings value of 986 kWh per year. This figure is based on the average c...
AI summary ENSC promoted replacing old refrigerators with more efficient models through LIH, using a unitary savings value of 986 kWh per year based on the ARet 2013 Evaluation Report. The savings are calculated by comparing the average consumption of old appliances (1,394 kWh/year) with new ENERGY STAR® models (408 kWh/year).
Tracked Savings ENSC promotes the replacement of old freezers with more efficient models Through LIH. For this measure, ENSC uses a unitary savings value of 540 kWh per year, based on the 2013 LIH evaluation report. This figure is based on...
AI summary ENSC promotes replacing old freezers with more efficient models through LIH programs, using a unitary savings value of 540 kWh per year based on data from the 2013 LIH evaluation report and NRCan EnerGuide Appliance Directory.
Revised Savings In 2014, the majority of the new models installed were ENERGY STAR® models (98 %), but non-ENERGY STAR® models were also installed when ENERGY STAR® models of the same size were not available. In fact, Energy Star has recen...
AI summary In 2014, Efficiency Nova Scotia Corporation (ENSC) installed mostly ENERGY STAR® freezers, but non-ENERGY STAR® models were used when smaller sizes were unavailable. The Evaluator updated savings calculations to reflect the installation of non-ENERGY STAR® freezers and used data from the ARet 2014 Evaluation Report to establish average consumption values for both old and new freezers, resulting in a weighted unitary savings value of 496 kWh per year.
2.2 Interactive Effects In a residence, interactive effects occur when the implementation of energy efficiency measures has an impact on the energy consumption of other elements such as space-heating and cooling equipment. For LIH in 2014,...
AI summary Interactive effects refer to how energy efficiency measures in a residence can influence the energy consumption of other systems like heating and cooling. For low-income homeowners in 2014, it was assumed that no prescriptive measures caused significant interactive effects, and thus they were considered negligible.
2.4 Net Savings Net savings were estimated by applying the interactive effects and the NTGR to the gross energy savings, using the equation below. Net savings = Gross Evaluation Savings × (1 + Interactive Effects Factor) × NTGR As with pre...
AI summary Net savings for LIH were calculated using the NTGR and interactive effects factor. Due to the transfer of certain measures to RDI, the interactive effects factor was not applied, leading to a simplified calculation. Total net energy and peak demand savings were estimated at 2.101 GWh and 0.490 MW at the meter, and 2.311 GWh and 0.539 MW at the generator.
3 VALIDATED TRACKED SAVINGS This section presents the gross and net savings for New Home Construction in 2014.
AI summary This section presents the gross and net savings for New Home Construction in 2014, providing insights into energy efficiency and cost savings achieved through construction practices during that year.
3.1.1 Unitary Savings Value per EnerGuide Point Increase The next sections present the three key features used to calculate gross energy savings under New Home Construction, namely the EnerGuide baseline, the savings per EnerGuide point ca...
AI summary This section outlines the three key features used to calculate gross energy savings under New Home Construction: the EnerGuide baseline, savings per EnerGuide point calculated with HEA participants, and 2012 billing calibration results.
New House EnerGuide Baseline The average baseline EnerGuide rating was adjusted to 78 from 80 in the 2011 evaluation. A literature review was conducted in 2013 since the residential new house market in Canada has significantly evolved in r...
AI summary The EnerGuide baseline rating was adjusted from 80 to 78 in 2011. A 2013 literature review supported this adjustment, as Nova Scotia adopted the 2012 NBC Part 9 revision, which corresponds to an EnerGuide rating of 78 when modelled in HOT2000 version 10. The Evaluator maintains that this baseline remains relevant in the current market.
Where › ER corresponds to the EnerGuide Rating for participating households heated by electrical source only. The savings per EnerGuide point value was updated for this evaluation with HEA participants for the year 2014. The following sect...
AI summary The savings per EnerGuide point value was updated for HEA participants in 2014. The methodology used by the Evaluator to determine this new value is described in the following sections.
Data Processing The Evaluator used the pre-retrofit (D) and post-retrofit (E) EnerGuide ratings as well as the modelled consumption provided for the 2014 HEA participants. The requested information was provided for a total of 450 HEA parti...
AI summary The Evaluator used pre- and post-retrofit EnerGuide ratings from 450 HEA participants to analyze energy savings. Projects with decreased or unchanged ratings, and those with ratings higher than 50 were excluded. The data was processed to ensure a representative sample for analysis.
EnerGuide Rating The 450 participants selected by the Evaluator were used to analyze the average space heating energy savings per EnerGuide point through the comparison of pre-retrofit (D) and post-retrofit (E) simulation results. Since th...
AI summary The Evaluator analyzed 450 participants to determine average space heating energy savings per EnerGuide point by comparing pre- and post-retrofit simulation results. The focus was on space heating load decrease, and the approach avoided weighting any participant more than others by calculating individual savings before averaging.
Calibration For the 2012 evaluation of the EnerGuide programs (HEA, Low Income Homeowner [LIH] and Performance Plus), a billing analysis was performed over 416 participants 6 to evaluate the accuracy of the modelled heating consumptions ob...
AI summary The 2012 and 2014 evaluations of EnerGuide programs used an 18% calibration adjustment based on HOT2000 simulations and billing data. The 2014 evaluation confirmed the continued validity of this adjustment, leading to a final EnerGuide point savings value of 891 kWh, slightly higher than the 882 kWh tracked in the 2013 evaluation.
3.1.3 Validated Gross Savings The annual gross savings tracked for the building envelope measures in 2014 were validated by the Evaluator and are presented in Table 5. Overall, the gross energy and peak demand savings amount to 5.328 GWh a...
AI summary The validated gross savings for building envelope measures in 2014 were 5.328 GWh and 1.369 MW at the meter. Using a line loss factor of 1.100, the gross savings at the generator level were calculated as 5.861 GWh and 1.506 MW.
3.3.2 Spillover (Market Effects) The builder survey was used to assess spillover in the form of market effects, which can occur when a builder decides to implement energy efficiency measures in new construction projects without participati...
AI summary The builder survey was used to assess market effects, where builders implement energy efficiency measures without program participation. Surveys from 2011 to 2014 showed varying market effects, ranging from 5% to 13%.
Free-Ridership (FR Series) - FR1. Did you decide to build or buy a house with a high level of energy efficiency, before participating in the [Performance Plus/New Home Construction] program? - 1. Yes - 2. No - 98. (Don't know) - 99. (Refus...
AI summary This section of the Free-Ridership (FR Series) survey asks participants whether they decided to build or buy a highly energy-efficient home before participating in the Performance Plus/New Home Construction program. It also seeks to determine the likelihood that participants would have taken energy-efficient actions in the absence of the program.
FR2a. PERFORMANCE PLUS: STAR certification or higher and consuming less than 19,000 kWh? Response 98 Don't Know built or bought a house with the exact same level of efficiency, therefore reaching an EnerGuide rating of [EnerGuide rating]?...
AI summary The text discusses the PERFORMANCE PLUS program, focusing on energy efficiency standards for new home construction, including EnerGuide ratings and ENERGY STAR certification. It includes responses such as 'Don't Know' and 'Refused' to questions about home construction and energy consumption.
response to a previous question that if the [Performance Plus/New Home Construction] program had not been available there was [a/an] [INSERT RESPONSE FROM FR2c] in 10 likelihood that you would have built or bought a house with the exact sa...
AI summary The text outlines survey questions related to the Performance Plus/New Home Construction program, focusing on the likelihood of building or buying a house with the same level of efficiency at a later date and the impact of rebates on customer behavior. It includes response options and probing instructions for detailed answers.
___ Response - 96. (Did not receive that rebate) - 97. (Don't Know) - 98. (Refused) [ASK FR3_2 IF, IN SAMPLE, TOTAL INCENTIVE=EMPTY] FR3_2. Efficiency Nova Scotia gave you a rebate for the energy efficiency level that you achieved in your...
AI summary The text presents a survey question regarding whether respondents would have paid for energy efficiency measures if they had not received a rebate from Efficiency Nova Scotia. The question asks respondents to rate their likelihood on a scale from 0 to 10.
V4. Did you take part in the decisions regarding the energy efficiency measures to install through the [Performance Plus/New Home Construction] program? Homeowner Involved in Decision to Implement the Energy Efficiency Measures 2012 2013 2...
AI summary The text discusses homeowner involvement in decisions regarding energy efficiency measures through the Performance Plus/New Home Construction program, showing high participation rates and the stages at which homeowners became involved in the process.
FR4. Next, I'm going to ask you to rate the importance of the [Performance Plus/New Home Construction] program as well as other factors that might have influenced your decision to build or buy a house with a high level of energy efficiency...
AI summary The text requests participants to rate the importance of the Performance Plus/New Home Construction program and other factors influencing their decision to build or buy a highly energy-efficient home, using a scale from 0 to 10.
Importance of Program in Influencing Homeowner Decision to Build or Buy a House with a High Level of Energy Efficiency 2 012 2013 2014 Sample Size Important Sample Size Important Sample Size Important Mean (0 = "Not at all important"; 10 =...
AI summary The document discusses the importance of energy efficiency programs in influencing homeowner decisions to build or buy energy-efficient homes. It highlights the significance of incentives, EnerGuide labels, expert advice, and homeowner contact with Efficiency Nova Scotia. The data shows increasing engagement with the programs over the years.
- CS4. Now I will read you a list of factors, and I would like to know how satisfied you were with each in terms of your experience with Efficiency Nova Scotia. On a scale of 1 to 10, where "1" is not at all satisfied and "10" is completel...
AI summary The text presents a survey question asking respondents to rate their satisfaction with various factors related to their experience with Efficiency Nova Scotia on a scale from 1 to 10.
CS28. How likely would you be to participate in other programs offered by Efficiency Nova Scotia if your household qualified? Would you definitely, probably, probably not, or definitely not participate in other programs?
AI summary This question asks respondents about their likelihood of participating in other programs offered by Efficiency Nova Scotia if their household qualified, with response options ranging from 'definitely' to 'definitely not'.
Would Participate in Other ENSC Programs 2012 2013 2014 Sample Size 30 70 47 Definitely 87% 73% 64% Probably 10% 27% 21% Probably not - - 6% Definitely not 3% - 9% \ &# x27;Don't know'/'Refused' have been removed from calculations
AI summary The table shows participation rates in other ENSC programs over the years 2012 to 2014, with a decrease in the percentage of participants who 'definitely' would participate and an increase in those who 'definitely not' would participate.
S10. Thinking of when you or the builder completed and sent the request for payment form to Efficiency Nova Scotia's program partner, how long, in days, was it before you received the rebate? Length of Time to Receive Rebate 2014 Sample Si...
AI summary The text asks about the time taken to receive rebates after submitting a payment request to Efficiency Nova Scotia's program partner. It includes statistical data on the length of time it took for rebates to be received in 2014, with the majority taking 50 days or more. Additional questions about the type of residence and number of bedrooms are included with sample data from 2012 to 2014.
INTRODUCTION – PARTICIPANT BUILDERS (FROM SAMPLE) Hello, my name is _________ and I am with CRA (Corporate Research Associates), and we are performing an evaluation of energy efficiency services provided by Efficiency Nova Scotia Corporati...
AI summary CRA is conducting an evaluation of Efficiency Nova Scotia Corporation's energy efficiency programs, specifically the Performance Plus and New Home Construction programs. They are seeking input from participants to improve the programs and understand the residential new construction market.
INTRODUCTION – NON PARTICIPANT BUILDERS (FROM SAMPLE) Hello, my name is _________ and I am with CRA (Corporate Research Associates), a Halifax-based survey research company. We are performing an evaluation of energy efficiency services pro...
AI summary This section introduces a survey conducted by CRA on behalf of Efficiency Nova Scotia Corporation to evaluate residential energy efficiency programs, including the Performance Plus and New Home Construction programs, which provide rebates for energy-efficient home construction in Nova Scotia.
Verification and Recall (VR Series) - VR1. Are you in the business of building and/or selling homes? - 1. Yes [CONTINUE] - 2. No [THANK & TERMINATE] - 98. (Don't know) [THANK & TERMINATE] - 99. (Refused) [THANK & TERMINATE] VR2. Approximat...
AI summary This section of the document outlines a series of verification and recall questions directed at builders in Nova Scotia, focusing on their participation in energy efficiency programs such as Performance Plus and New Home Construction. The questions aim to determine the number of homes built and their eligibility for rebates based on specific timelines and energy performance criteria.
VOLUNTEERED - 4. Neither [PROMPT: "Are you sure? This program provides rebates for installing energy efficient upgrades in newly constructed houses. Plans for the house are reviewed and recommendations are given for upgrades to install in...
AI summary The text outlines a volunteer process for a program that provides rebates for energy-efficient upgrades in newly constructed homes, including prompts to confirm participation in the Performance Plus and New Home Construction programs.
FOR BUILDERS THAT PARTICIPATED IN BOTH PROGRAMS (VRP2=3), ASK VRP4a and VRP4b - VRP4a. [ASK PP PARTICIPANT BUILDERS BASED ON VRP2 = 1 OR 3 ] Among the new houses that you have built so far in 2014 in Nova Scotia, how many have been built u...
AI summary The text outlines survey questions directed at builders who participated in both the Performance Plus and New Home Construction programs in 2014. It asks for the number of homes built under each program, eligibility criteria, and who typically makes the decision to participate. The survey emphasizes providing specific numerical answers and considers the builder's overall experience with the programs.
Market Effects – Non Participants (M Series) We will now talk about the houses you have built in 2014 without participating in the Performance Plus and/or New Home Construction program. - M1. Before today, had you ever heard of the Perform...
AI summary This section of the regulatory proceeding explores the energy efficiency measures implemented by non-participants in Efficiency Nova Scotia's programs, specifically the Performance Plus and New Home Construction programs, for houses built in 2014. It asks about awareness, participation, and the likelihood of implementing energy efficiency measures outside of these programs.
INSTRUCTION READ: "Can you please tell me which answer(s) need(s) to be corrected between the number of new houses you or your firm have built so far in 2014 in Nova Scotia and the number of houses built in Nova Scotia under the Performanc...
AI summary The text provides instructions for correcting answers related to the number of new houses built in Nova Scotia in 2014 and their participation in Efficiency Nova Scotia's programs. It also asks about energy efficiency measures implemented outside of these programs.
- n. Any others? Specify:______________ MP5. [DO NOT ASK IF NONE IN MP3 MENTIONED] What is the likelihood that you would have implemented those measures if you had never participated in Efficiency Nova Scotia's programs or heard of the Ene...
AI summary The text asks respondents to rate the likelihood of implementing energy efficiency measures without participation in Efficiency Nova Scotia's programs or knowledge of the EnerGuide rating, using a scale from 0 to 10.
CODE ONE RESPONSE FOR EACH FACTOR - a. The technical expertise of Efficiency Nova Scotia employees related to the program - b. The responsiveness of Efficiency Nova Scotia employees to your requests and enquiries in a timely manner - c. Th...
AI summary The text presents a series of questions aimed at evaluating the performance of Efficiency Nova Scotia in terms of technical expertise, responsiveness, timeliness, value, and ability to provide estimates of savings or return on investment.
CS1. How did your company first learn of the programs offered by Efficiency Nova Scotia? Source of Awareness 2013 2014 Sample Size 47 26 Delivery agent from Nova Scotia Home Builders Association 17% 38% Word of mouth – neighbour, friend, c...
AI summary The document discusses how companies first learned about Efficiency Nova Scotia's programs, with the majority citing delivery agents from the Nova Scotia Home Builders Association. It also explores who typically makes the decision to participate in the Performance Plus and New Home Construction program, with builders being the primary decision-makers.
FR3. Using a scale from 0 to 10, where 0 means "Not at all important" and 10 means "Extremely important", please rate the importance of the following, in terms of your decision to build houses [Performance Plus: with an EnerGuide rating of...
AI summary The document asks respondents to rate on a scale from 0 to 10 the importance of building houses with high energy efficiency standards, specifically Performance Plus (EnerGuide rating of 83 or higher) and New Home Construction (ENERGY STAR certified and consuming less than 19,000 kWh).
Importance in Influencing Builder 2012 2013 2014 Decision to Build Houses with a High Level of Energy Efficiency Sample Size Important Sample Size Important Sample Size Important Mean (1=Not at all important, 10=Extrem Incentive 30 9.1 89...
AI summary The table presents data on the importance of various factors in influencing builders to construct energy-efficient homes from 2012 to 2014. It highlights the mean importance scores for incentives, performance plus/new home construction, and energy modelling services, based on survey responses.
CS2. Did your company have any direct contact with any Efficiency Nova Scotia employees or did you only work with a third-party contractor or service delivery agent? Builder Contact with ENSC 2013 2014 Sample Size 47 26 Third-party contrac...
AI summary The text asks whether the company had direct contact with Efficiency Nova Scotia employees or worked only with third-party contractors. It also mentions a subsequent question about satisfaction with various factors related to Efficiency Nova Scotia.
CS5. Now, using the same 10 point scale, how satisfied are you with Efficiency Nova Scotia's overall performance in working with your company? 2 013 2014 Builder Satisfaction with Overall ENSC Performance Sample Size Satisfied Sample Size...
AI summary The text presents survey results regarding customer satisfaction with Efficiency Nova Scotia's performance in 2013 and 2014, including technical expertise, responsiveness, and the value of the program. It also includes data on customer interaction with ENSC's contact centre.
CS28. Based on your company's experience working with Efficiency Nova Scotia and its third-party contractors, would you definitely, probably, probably not, or definitely not participate in other programs offered by Efficiency Nova Scotia?
AI summary The question asks about the likelihood of participation in other programs offered by Efficiency Nova Scotia based on the company's experience working with Efficiency Nova Scotia and its third-party contractors.
Would Participate in Other ENSC Programs 2013 2014 Sample Size 46 26 Definitely 57% 58% Probably 43% 38% Probably not - 4% Definitely not - - 'Don't know'/'Refused' have been removed from calculations CS29. And based on your experience, ho...
AI summary The data shows that in 2013 and 2014, a majority of participants indicated they would definitely participate in other Efficiency Nova Scotia (ENSC) programs, with a slight decrease in 2014. Similarly, a high percentage of participants would recommend ENSC programs to other businesses, though this percentage also slightly decreased from 2013 to 2014.
S10. Thinking of when you or the homeowner completed and sent the request for payment form to Efficiency Nova Scotia's program partner, how long, in days, was it before you or the homeowner received the rebate?
AI summary The question asks about the time it took for Efficiency Nova Scotia's program partner to process a rebate request form and issue a rebate after it was submitted by the homeowner or the individual.
Length of Time for Homeowner to Receive Rebate 2014 (#) Sample Size 14 10-19 days 7% 20-29 days 7% 30-49 days 14% 50 days or more 71% Mean 57.5 "Don't know/refused" have been removed from calculation F1. Approximately how many full-time eq...
AI summary The document presents data on the time it takes for homeowners to receive rebates, with 71% taking 50 days or more. It also includes information on the number of full-time employees in participating and non-participating builders in Nova Scotia from 2012 to 2014.
Participant FR2a. If you had not participated in PPP/New Home Construction, what is the likelihood that you would have built or bought a house with the exact same level of efficiency? (Scale 0 to 1 0) FR2a = Answer x 1 0% FR2b. If you had...
AI summary The participant is asked about the likelihood of building or buying a house with the same level of efficiency without participating in the PPP/New Home Construction program, and the likelihood of opting for a standard house instead of an energy-efficient one. Answers are scaled from 0 to 10 and converted into percentages.
PA1 Score: FR1. Did you decide to build or buy a house with a high level of energy MEAN VALUE OF: (FR2a ; FR2b) efficiency, before participating in PPP/New Home Construction? IF 1. Yes: Use FR1a IF 2. No OR 99 : FR1 = 0% FR1a. I just want...
AI summary The text presents a survey question regarding energy efficiency decisions prior to participating in a program, asking whether the decision to build or buy a highly energy-efficient home was made before receiving a rebate. It also explores willingness to pay for additional efficiency measures without the rebate.
Builder FR1. Without PPP/New Home Construction, its energy modelling service, and its rebate, would you have built the same number of houses with the exact same level of efficiency? FR1a. I just want to make sure I understand - If PPP/New...
AI summary The questions focus on whether the PPP/New Home Construction program influenced the number and efficiency of houses built in Nova Scotia, specifically those meeting high energy efficiency standards such as EnerGuide rating of 83 or higher and ENERGY STAR certification.
PA1 Score: FR3. Rate the importance of the program and the incentive it offers in your decision to build houses reaching an EnerGuide rating of 83 or higher or that achieved ENERGY STAR certification and consumed less than 19,000 kWh?(Scal...
AI summary The PA1 Score evaluates the importance of a program and its incentives in encouraging the construction of energy-efficient homes with high EnerGuide ratings or ENERGY STAR certification and low energy consumption.
APPENDIX VI INTERNAL SPILLOVER METHODOLOGY The marketing of New Home Construction is primarily conducted through builders who receive promotion and awareness documents on various energy efficiency measures. Consequently, market effects, wh...
AI summary The appendix discusses the methodology for calculating internal spillover effects in the context of energy efficiency programs. It focuses on how builders may have implemented energy efficiency measures without formally participating in the New Home Construction or Performance Plus programs, using data from 2014 to estimate market effects.
Attribution Level %Attrib = MPS x MP2 I I:MP2 MP3. What measures have you implemented in those houses but not as part of Performance Plus/New Home Construction program? Validation of measures MP6. Why did you not take part in the Performan...
AI summary The text discusses questions about measures implemented in homes and reasons for not participating in the Performance Plus/New Home Construction program, focusing on validation of measures and eligibility.
Awareness and Influence Survey results showed that word of mouth was, by far, the main source of awareness for RDI in 2014. This way of learning about RDI was more prevalent among 2013 and 2014 participants. RDI was a new program component...
AI summary Survey results indicate that word of mouth was the primary source of awareness for the Residential Direct Install (RDI) program in 2014, with advertising from Efficiency Nova Scotia (ENSC) playing a smaller role. Participants often received information about energy-efficient products from installers, leading to behavioral changes such as turning off lights and reducing energy use.
3.1 Participation in RDI RDI totalled 13,945 participants for the year 2014, compared to 23,587 participants for 2013 and 28,397 participants for 2012. Even though the number of participants per se has decreased in 2014, RDI has reached it...
AI summary In 2014, the RDI program had 13,945 participants, a decrease from previous years, but still met its energy savings targets. The reduction in the number of participants was offset by increased savings per home due to the introduction of LEDs and smart power controllers.
Table 5: Implementation Status of Recommendations in 2012 Executive Summary Recommendation Status 2012 RDI-R1 Fine-tune the program marketing approach Implemented 2012 RDI-R2 Continue informing participants about energy-efficient products...
AI summary Table 5 outlines the implementation status of 2012 recommendations related to the Residential Direct Install (RDI) program. All recommendations were implemented by Efficiency Nova Scotia (ENSC), leading to program improvements, including a transition from CFL to LED installations due to market changes and free-ridership concerns.
3.4 Tracking System The Econoler team reviewed the 2014 RDI tracking sheet content. It was presented under the form of a spreadsheet, in which each of the DA's installations is compiled. At this point in time, ENSC does not use the DSMDS f...
AI summary The tracking system for the Residential Direct Install (RDI) program is reviewed, highlighting its use of spreadsheets to compile installation data. ENSC does not use the DSMDS for daily management, but the system tracks participant information, energy savings, and other relevant data for program evaluation. Some data collection challenges remain, such as missing rate codes.
3.5 On-site Visits during the Installation Process For the 2014 impact evaluation, three site visits with both RDI DAs were performed during the installation process. At the beginning of the appointment, the DA collected general informatio...
AI summary This section discusses the on-site visits conducted during the installation process for the 2014 impact evaluation. It details the procedures followed by DAs, including product replacement, quality checks, and participant interactions, as well as challenges encountered such as incompatible fixtures and existing tank wraps.
4.1 Partner Perspectives Interviews with two DAs were conducted as part of the RDI evaluation. Overall, RDI is viewed as valuable, efficiently administered, and effective in promoting energy efficiency. Changes made to RDI over the past ye...
AI summary The RDI program is viewed as effective and efficiently administered by DAs, though marketing limitations and product selection issues are noted. DAs highlight the importance of referrals and word of mouth in program participation, while expressing concerns about short-term contracts and limited product variety. Suggestions for improving educational outreach and streamlining promotional materials are made.
Table 6: Sources of Awareness Sources of Awareness 2012 2013 2014 Sample Size 181 159 164 TOTAL ADVERTISING 29% 19% 26% Mailings from ENSC 11% 9% 10% Newspaper 6% 5% 7% ENSC Website 4% 3% 7% Radio 8% 3% 2% Co-worker, family, friend 24% 50%...
AI summary Table 6 presents data on sources of awareness for energy efficiency programs in Nova Scotia from 2012 to 2013. It shows that word-of-mouth (co-workers, family, friends) was the most common source of awareness, with significant increases in 2013 and 2014. Advertising and ENSC mailings were also notable sources, though their percentages fluctuated over the years.
Table 7: Reasons for Participating 2012 2013 2014 Reasons for Participating Most Important Motivation Other Important Motivations Most Important Motivation Other Important Motivations Most Important Motivation Other Important Motivations S...
AI summary Table 7 presents data on participants' motivations for joining energy efficiency programs from 2012 to 2014, with saving on energy costs being the most common reason. Some participants had concerns about the RDI program, including potential fees, lack of actual savings, and discomfort with home visits.
Table 9: Behavioural Changes Behavioural Changes 2012 2013 2014 Sample Size 66 65 58 I turn off my lights now 48% 48% 52% More aware of power usage/saving energy 18% 34% 17% I turn off appliances 5% 8% 14% Reduce water consumption/Not wast...
AI summary Table 9 presents data on behavioural changes related to energy usage from 2012 to 2014, showing trends in awareness and adoption of energy-saving practices among respondents. Notable shifts include increased awareness of power usage and reduced use of energy-efficient light bulbs over time.
Table 11: Recommendations for Improvement Suggestions 2012 2013 2014 Sample Size 181 159 164 Offer more products/measures to be installed 6% 9% 10% Better advertising/program awareness 13% 5% 4% Offer more information on the products/measu...
AI summary Table 11 presents recommendations for improvement across three years (2012–2014), with the majority of respondents indicating no other recommendations. The most common suggestions include offering more products, better advertising, and providing more information on installed measures.
5 IMPACT EVALUATION FOR RDI The objective of the 2014 RDI impact evaluation is to determine the gross and net energy savings generated by the energy-efficient products installed in participating households. Both electrical energy and peak...
AI summary The 2014 RDI impact evaluation aims to assess the gross and net energy savings from energy-efficient product installations in participating households, considering factors like unitary savings values, installation rates, and free-ridership.
5.1 Gross Savings The quantities of products installed under the program were computed in the tracking sheet. For each product, ENSC uses a unitary savings estimate that is based on past evaluation results, a literature review and technica...
AI summary The document discusses how Efficiency Nova Scotia (ENSC) calculates unitary savings estimates for products installed under the program, using past evaluations, literature reviews, and on-site technical data. Econoler reviews these estimates based on recent studies and data collected during on-site visits.
Tracked Savings In the tracking sheet, the quantity of CFLs installed is recorded under a different field for each combination of replaced lamp wattage (40 W, 60 W or 100 W) and new lamp wattage (13 W or 23 W). ENSC uses a different unitar...
AI summary The document discusses how Efficiency Nova Scotia (ENSC) calculates unitary savings values for Compact Fluorescent Lamps (CFLs) based on wattage differences between old and new lamps, using a formula that incorporates hours of operation derived from a Hydro-Québec study.
Table 12: Tracked Unitary Savings Values for Each Category of CFL Category of CFL Old Wattage (W) New Wattage (W) Displaced Wattage (W) Hours of Operation (h/day) Unitary Savings Value (kWh/year) 13 W replacing 40 W 40 13 27 2.7 26.6 13 W...
AI summary Table 12 presents unitary savings values for different categories of Compact Fluorescent Lamps (CFL) based on wattage displacement and hours of operation. Each row shows the old and new wattage, displaced wattage, hours of operation, and the resulting unitary savings value in kWh per year.
Table 13: Tracked Unitary Savings Values for Each Category of LED Category of LED Old Wattage (W) New Wattage (W) Displaced Wattage (W) Hours of Operation (h/day) Unitary Savings Value (kWh/year) 8 W replacing 40 W 40 8 32 2.68 31.3 8 W re...
AI summary Table 13 presents unitary savings values for different categories of LED replacements, showing the energy savings achieved by replacing higher wattage bulbs with lower wattage LEDs. The table includes old and new wattages, displaced wattage, hours of operation, and unitary savings in kWh per year.
mple is by far the greatest of all studies and (3) it includes a very detailed analysis of variations in hours of operation by type of bulbs (including LEDs), geographical location and household type. Indeed, some conclusions of this study...
AI summary The study analyzes variations in lighting hours of operation by bulb type, geographical location, and household type, revealing that efficient bulbs like LEDs and CFLs are used more hours compared to inefficient ones like halogen and incandescent bulbs. Three theories are proposed to explain this behavior: differential socket selection, shifting usage, and snapback.
Table 15: Revised Unitary Savings Values for Each Category of LED Category of LED Old Wattage (W) New Wattage (W) Displaced Wattage (W) Hours of Operation (h/day) Unitary Savings Value (kWh/year) 8 W replacing 40 W 40 8 32 2.7 31.5 8 W rep...
AI summary Table 15 provides revised unitary savings values for different categories of LED replacements, showing the displaced wattage and annual energy savings based on old and new wattages and hours of operation.
Tracked Savings For LED nightlights installed through RDI, ENSC uses an estimated unitary savings value of 29.3 kWh per year. The assumptions used to make the savings calculation are presented in Table 16.
AI summary The document discusses the use of an estimated unitary savings value of 29.3 kWh per year for LED nightlights installed through RDI, with the assumptions for this calculation detailed in Table 16.
Table 16: Tracked Unitary Savings Value for LED Nightlights Parameter Value Old Wattage (incandescent nightlight) 7 W New Wattage (LED nightlight) 0.3 W Average Displaced Wattage 6.7 W Operating Time 12 h/day Unitary Savings 29.3 kWh/year...
AI summary Table 16 presents the tracked unitary savings value for LED nightlights, showing a significant reduction in wattage from incandescent to LED models, resulting in 29.3 kWh/year of energy savings per unit.
The old wattage for incandescent nightlights and their hours of operation are still considered adequate. This year, the only variation is on the wattage value of the LED nightlights installed. One DA installed a 0.5 W nightlight, while the...
AI summary The document discusses the evaluation of energy savings from LED nightlights installed by two different DAs. The wattage of the nightlights varied, leading to a weighted average calculation and a revised annual unitary savings of 29.1 kWh.
Table 17: Revised Unitary Savings Value for LED Nightlights Parameter Value Old Wattage 7 W New Wattage 0.36 W Average Displaced Wattage 6.7 W Hours of operation 12 h/day Unitary Savings 29.1 kWh/year 5.1.4 Faucet Aerators
AI summary Table 17 presents the revised unitary savings value for LED nightlights, detailing parameters such as old and new wattage, average displaced wattage, hours of operation, and annual unitary savings. The section also references Faucet Aerators under a separate heading.
Tracked Savings For low-flow showerheads installed in homes with electrical DHW systems through RDI, ENSC uses a specific unitary savings value of 288 kWh, 377 kWh or 607 kWh depending on the flow rate reduction, which can be respectively...
AI summary The document discusses the unitary savings values used for low-flow showerheads installed in homes with electrical DHW systems through RDI, with values of 288 kWh, 377 kWh, or 607 kWh depending on the flow rate reduction. These values are derived from the 2011 OPA Prescriptive Measures and Assumptions.
Tracked Savings For each three-foot unit of insulated pipe, ENSC uses a savings value of 38 kWh per year. The source of this value is the OPA 2011 report. No further savings are given when the length of the insulated piping is greater than...
AI summary ENSC uses a savings value of 38 kWh per year for each three-foot unit of insulated pipe, based on the OPA 2011 report. No additional savings are recognized for insulated piping longer than 15 ft, resulting in a maximum value of 190 kWh.
Tracked Savings Hot water tank wraps are installed on electric tanks under RDI. For this product, ENSC uses a unitary savings value of 270 kWh per year, based on the 2011 OPA Prescriptive Measures and Assumptions. It is worth mentioning th...
AI summary The document discusses the use of a unitary savings value of 270 kWh per year for hot water tank wraps installed on electric tanks under RDI, based on the 2011 OPA Prescriptive Measures and Assumptions. This value is still used by OPA in its 2014 version and is derived from specific conductance values for heaters with and without tank wraps.
Revised Savings In 2014, the installed tank wrap RSI-value was 0.90 m2 ·°C/W. This was confirmed with DAs during on-site visits. Econoler reviewed the assumptions and the engineering calculations used by both the Pennsylvania Public Utilit...
AI summary In 2014, the installed tank wrap RSI-value was confirmed as 0.90 m2 ·°C/W through on-site visits. Econoler reviewed assumptions and calculations used by the Pennsylvania Public Utility Commission and the Ontario Power Authority, both of which use the same equation to estimate savings from hot water tank wraps.
Where: - › Ubase: thermal transmittance per area unit of water heater prior to adding tank wrap [W/m 2 .°C] - › Abase: surface area of storage tank prior to adding tank wrap [m2 ] - › Uinsul: thermal transmittance per area unit of water he...
AI summary The text discusses the differences in thermal transmittance calculations between the Ontario Power Authority (OPA) and the Pennsylvania Public Utility Commission TRM. It highlights a drawback in the equations used by both utilities, where increasing insulation thickness leads to overestimation of heat loss. The Evaluator adjusted the calculation to better estimate energy savings from tank wraps using the formula for heat transfer in an insulated cylinder.
Table 20: Revised Unitary Savings Value for Hot Water Tank Wraps Variable Value Unit Source Layer 1: Interior Insulation of Tank re 0.300 M Giant21 ri 0.262 M Idem k 0.018 W/m°C Idem Rlayer 1.198 m°C/W Calculation RTop 2.113 m°C/W Giant La...
AI summary Table 20 presents the revised unitary savings value for hot water tank wraps, including variables such as thermal resistance, heat transfer rates, and energy savings calculations. The data is based on estimates and specifications from various sources, including Frost King Insulation Blanket and the Pennsylvania Public Utility Commission.
5.1.9 Installation Rates In order to calculate the RDI installation rates, 50 on-site visits were conducted in participating households. The quantity of installed products was recorded and verified against the quantity indicated in the tra...
AI summary To calculate RDI installation rates, 50 on-site visits were conducted in participating households. Recorded product quantities were verified against the tracking system, and installation rates were determined based on acceptable error margins.
Table 21: Percentage of Products Installed and Installation Rate Type of Product Quantity Installed – From Tracking Sheet Quantity Installed – From On-site Visits Percentage of Products Installed Error Margin26 Installation Rate Applied to...
AI summary Table 21 shows the percentage of products installed and their installation rates, with smart power controllers having the lowest installation rate at 78%. Other products with installation rates below 90% include LED nightlights, pipe insulation, and faucet aerators, with issues such as participant dissatisfaction and entry errors in tracking sheets.
Table 22: Tracked Evaluation Results – Gross Energy and Peak Demand Savings by Product C F Ls Ca f Pr du te t g or y o o c 1 3 W Re la in p c g 4 0 W 1 3 W Re la in p c g 6 0 W 1 3 W Re la in p c g 1 0 0 W 2 3 W Re la in p c g 4 0 W 2 3 W...
AI summary Table 22 presents tracked evaluation results for energy and peak demand savings by product, including installation rates, total units, savings in kilowatt-hours, and peak demand savings in megawatts for various categories of products.
(Continued) LED L _amps Category of Product 8W Replacing 40W 8W Replacing 60W 8W Replacing 100W 10.5W Replacing 40W 10.5W Replacing 60W 10.5W Replacing 100W 11W Replacing 40W 11W Replacing 60W 11W Replacing 100W 12W Replacing 40W Energy Sa...
AI summary The text presents a detailed table outlining energy savings data for various LED light products, including installation rates, energy savings values, and peak demand savings. The table includes metrics such as total number of units, installation rates, and gross energy and peak demand savings at both the meter and generator levels.
5.2 Interactive Effects In a home, interactive effects occur when the implementation of energy efficiency measures has an impact on the energy consumption of other elements such as heating and cooling. In the case of RDI, replacement of in...
AI summary Interactive effects in energy efficiency measures, such as replacing incandescent lighting with CFLs or LEDs, can influence heating and cooling loads in homes. This is based on a 1992 study by ADS for Hydro-Québec using DOE-2 simulations, which considered three interactive-effects scenarios. The low-impact scenario was selected for calculations, reflecting home evolution since 1992.
Table 23: Interactive Effects Calculation for Lighting Products Parameter % of Residences28 Interactive Effects29 Electric heating with air conditioning 14% -54.4% Electric heating without air conditioning 29% -58.0% No electric heating wi...
AI summary Table 23 shows the interactive effects of lighting products on residential energy use, with different percentages based on heating and air conditioning configurations. The weighted interactive effect factor is -24.0%, but adjustments were made to account for outdoor installations of CFLs and LED lamps, while LED nightlights retain the -24.0% factor.
Project No. 5870 38 27 DOE-2 is a widely used and accepted building energy analysis software tool, developed with U.S. Department of Energy funding. 28 From RDI 2014 tracking sheet. 29 ADS ASSOCIÉS, Évaluations des effets énergétiques comb...
AI summary The text references the DOE-2 building energy analysis software and a 1992 report on combined energy efficiency measures in single-family homes, citing a tracking sheet from the RDI 2014 and a report by ADS ASSOCIÉS.
Table 24: Interactive Effect Factors for CFLs, LED Lamps and LED Nightlights Category of Product % Indoor % Outdoor Interactive Effect Factor CFL 86% 14% (86% × -24.0%) + (14% × 0%) = -20.6% LED Lamp 88% 12% (88% × -24.0%) + (12% × 0%) = -...
AI summary The document presents interactive effect factors for CFLs, LED lamps, and LED nightlights, showing how their energy efficiency impacts heating and cooling loads. It also discusses insulation and hot water tank wraps, with interactive effects of -100% during heating and +100% during cooling. A weighted interactive effect factor of -24.2% is calculated based on heating and cooling periods in the Halifax region.
Table 25: Interactive Effect Factor for Pipe Insulation and Hot Water Tank Wraps Parameters % of Residences31 Interactive Effects During Heating Period Interactive Effects During Cooling Period Electric heating with air conditioning 14% -1...
AI summary Table 25 presents the interactive effect factor for pipe insulation and hot water tank wraps in different residential heating and cooling scenarios. It shows the percentage impact during heating and cooling periods, with weighted interactive effect factors calculated for each scenario.
Table 27: Evaluated Net Energy and Peak Demand Savings by Product C F Ls Ca f Pr du te t g or y o o c 1 3 W Re la in p c g 4 0 W 1 3 W Re la in p c g 6 0 W 1 3 W Re la in p c g 1 0 0 W 2 3 W Re la in p c g 4 0 W 2 3 W Re la in p c g 6 0 W...
AI summary Table 27 presents evaluated net energy and peak demand savings by product, including data for various light bulb types and their energy efficiency metrics. The table includes values for gross total energy savings, net-to-gross ratio, and other relevant factors.
Table 28: Comparison of Tracked and Evaluated Savings at the Generator Initial Gross Savings Installed Gross Savings Installed Gross Savings with Interactive Effects NTGR Net Savings Energy Savings Tracked Savings from ENSC 32.001 GWh 32.0...
AI summary The evaluated energy and peak demand savings from the program are slightly lower than the tracked savings. The evaluator adjusted unitary savings downward for some products, and installation rates have decreased. However, lower free-ridership and higher spillover levels increased the NTGR, partially offsetting these reductions, resulting in a 2% decrease in net energy savings.
6 IMPACT EVALUATION FOR THE CBSM PILOT The evaluation of the CBSM pilot aimed at quantifying the net savings resulting from the increased proportion of cold water washing done by the CBSM Pilot participants. A total of 438 participants too...
AI summary The CBSM Pilot impact evaluation quantified net savings from increased cold water washing among 438 participants. The evaluation details the methodology used to calculate these savings.
6.1 Unitary Savings Analysis To obtain an average annual savings value per pilot participant, the following method was used: - › Establishing the number of laundry loads done per week and the number of loads done in warm water for both the...
AI summary The Unitary Savings Analysis calculates average annual savings per participant by comparing laundry habits between control and treatment groups. The analysis uses data from an annual phone survey, which included questions on cold water washing habits. Outliers were removed to ensure more reliable averages.
Adjustment for the Age of Clothes Washers Because the MEF and capacity were first extracted from currently available data on new clothes washers in 2013, an adjustment needs to be made to take into account the increased energy efficiency o...
AI summary The document discusses the need to adjust energy efficiency calculations for clothes washers, considering improvements in efficiency over time. Average water usage data from 2005 to 2010 was used to make this adjustment.
6.4 Net Savings In total, the CBSM Pilot generated net energy savings of 0.050 GWh at the meter and 0.055 GWh at the generator, and net demand savings of 0.012 MW at the meter and 0.013 MW at the generator, as shown in the table below.
AI summary The CBSM Pilot generated net energy savings of 0.050 GWh at the meter and 0.055 GWh at the generator, along with net demand savings of 0.012 MW at the meter and 0.013 MW at the generator.
Table 31: CBSM Pilot Net Evaluated Energy Savings Parameter Value Energy Savings Total Number of Participants 438 Net Unitary Savings Value (kWh) 114 Interactive Effect Factor 0% Total Net Energy Savings – at meter (GWh) 0.050 Line Loss Fa...
AI summary Table 31 presents the net evaluated energy savings from the CBSM Pilot, including total participants, unitary savings, and both energy and peak demand savings at the meter and generator levels, with adjustments for line loss factors.
Aspects of the program Score 1 = very poor 10 = excellent NA = not applicable Reason Please share the reason(s) for your score The overall program The program marketing and outreach activities initiated by ENSC Your relationship with ENSC...
AI summary The Residential Direct Installation of Efficient Products program has undergone modifications, including the removal of CFLs and the addition of LED bulbs. The text asks for feedback on the impact of these changes and barriers to program delivery, as well as the extent to which the program has achieved its educational goals.
On-site Visit Protocol On-site visits were conducted to validate the quantity of installed products documented in the tracking system against the actual situations observed on site. This process served two main purposes: 1) to establish th...
AI summary On-site visits were conducted to verify the installation of energy efficiency products and assess their savings values. Evaluators collected data on lamp types, locations, hot water heating sources, and other parameters to determine installation rates and product removal reasons.
1 General Information Date of Visit: Tracking Number: Address: Contact Name: Telephone: Type of Dwelling: Individually Metered: Yes No Main Heat Type: DHW Heat Type: AC Used in Home Yes No
AI summary This document appears to be a form used during a home energy assessment, capturing information about the dwelling, contact details, and energy usage. It includes fields for tracking numbers, addresses, heat types, and whether the home is individually metered.
For Domestic Hot Water (DHW) Related Products Product Number in Tracking Sheet Number On Site Explanation If Different Type of Lamp Replaced Wattage of Lamp Replaced Inside or Outside 13W CFL 23W CFL 8W LED 10.5W LED 11W LED 12W LED LED Ni...
AI summary The text provides a table listing various domestic hot water (DHW) related products, including lamps and insulation materials, along with tracking and site numbers. The tables are incomplete and lack detailed information about the products, their quantities, and explanations for discrepancies.
INTRODUCTION V2. Hello, my name is and I am with CRA (Corporate Research Associates), and we are performing an evaluation of energy efficiency services provided by Efficiency Nova Scotia Corporation. Our records indicate that you or your h...
AI summary The text introduces a survey conducted by CRA (Corporate Research Associates) on behalf of Efficiency Nova Scotia Corporation to evaluate the Residential Direct Installation of Efficient Products (RDIEP) program. Participants are asked to provide feedback on their experience with the installation of energy efficiency products like CFLs and faucet aerators.
- 7 No, I don't remember the program / Don't know [PROMPT: "Are you sure? Someone would have come to your house and installed free energy-efficient products for you to save energy and money?" RECODE AS "YES" IF THE PROMPT WORKS; IF RESPOND...
AI summary The text contains a series of prompts and response options related to participation in the Efficiency Nova Scotia program, including questions about whether a respondent or someone in their household participated in the program and whether energy-efficient products were installed.
[ASK ALL RESPONDENTS] V3. I am going to read you a list of energy-efficient products that, according to our records, were installed in your house by the program: [READ WHAT IS ON RECORD (MEASURE≠0 IN THE DATABASE)]. For each one, can you p...
AI summary The text outlines a survey process to verify the installation of energy-efficient products in homes, such as CFL bulbs, LED bulbs, and low-flow showerheads, by asking respondents to confirm installation records. It includes instructions for data collection and handling responses.
- 98. (Don't Know) - 99. (Refused) [THANK AND TERMINATE] [IF P1 = 2 'NO'] Please answer the survey questions based on the house that went through the program. - P2. How did you find out about this program? [DON'T READ; ALLOW MULTIPLE RESPO...
AI summary The text includes survey questions about how participants found out about a program, with options including Efficiency Nova Scotia staff, mailings, the ENSC website, and others. Some responses are marked as 'Don't Know' or 'Refused'.
P3. What was the SINGLE most important reason you agreed to participate in the program? [ACCEPT ONE RESPONSE] [DO NOT READ] 1 2 3 4 5 6 7 8 96. 98. 99. (To save on energy/to save on energy costs) (Comfort) (To receive free compact fluoresc...
AI summary The document contains survey questions related to customer participation in energy efficiency programs, focusing on motivations, concerns, and satisfaction levels. It explores reasons for joining the program, additional motivations, and pre-participation concerns.
S2. [IF DISSATISFIED—S1=1, 2 or 3] You indicated a score of [ANSWER S1] on a 5-point scale for your overall satisfaction with the program. For what reasons were you not satisfied with the program overall? Probe: Any other reasons? [DO NOT...
AI summary The text presents a survey questionnaire assessing customer satisfaction with an energy efficiency program. It asks participants to rate their satisfaction and provides options for reasons for dissatisfaction or satisfaction with the program.
S4. Overall communication from the program 1 2 3 4 5 97/98/99 S5. Time required to complete work 1 2 3 4 5 97/98/99 S6. Energy conservation measures installed 1 2 3 4 5 97/98/99 S7. Quality of the work completed 1 2 3 4 5 97/98/99 S8. Usin...
AI summary The text presents a series of survey questions related to the efficiency program, including the time required to complete work, energy conservation measures installed, and the quality of work completed. It also asks respondents to rate the ease of applying to the program on a 5-point scale.
[ASK PILOT PARTICIPANTS] - PP1a. According to our records, your household received information during the visit from the installer about the benefits of washing your clothes in cold water. The installer would have spoken to you about your...
AI summary The document includes survey questions directed at participants in a pilot program aimed at encouraging cold water washing. It seeks to determine if participants recall information provided by installers, whether they agreed to wash in cold water, and their level of satisfaction with the project.
[IF B2=1] How did your behavior change? PROBE: Anything else? [DO NOT READ. ACCEPT ALL RESPONSES] (I turn off my lights now) 1 (I set my heating thermostat lower) 2 (I set my water heater thermostat lower) 3 (I hang my clothes to dry) 4 (I...
AI summary The text presents a survey questionnaire focusing on customer behavior changes related to energy efficiency, including turning off lights, adjusting thermostats, and participating in ENSC programs. It also asks about the number of laundry loads and satisfaction with cold water washing.
P3. What was the single most important reason you agreed to participate in the program? P4. Were there any other reasons? 2012 2013 2014 Reasons for Participating Most Important Motivation Other Important Motivations Most Important Motivat...
AI summary The table shows participants' reasons for joining an energy efficiency program between 2012 and 2014. The primary motivation was saving on energy costs, with over 60% of respondents citing this as their main reason. Other motivations included environmental concerns, receiving free services, and energy-efficient upgrades. A small percentage of participants had concerns about the program prior to joining.
S3. What was the most important reason why you were satisfied with the program overall? Anything else? Reasons for Satisfaction 2012 2013 2014 Sample Size 171 141 147 I liked the installer who visited the home 35% 33% 34% Lowered energy bi...
AI summary The table shows the reasons for satisfaction with a program from 2012 to 2014, with the most common reason being the installer who visited the home. Other reasons include lowered energy bills, good service, and informative materials received.
S10. Thinking of when you first contacted ENSC about the program, or ENSC contacted you, how long, in days, was it before the products were installed in your household? Time Between First Contact with ENSC and Product Installation 2013 201...
AI summary This section asks respondents how long it took between their first contact with ENSC and the installation of energy-efficient products in their household. The data shows a mean of 15.5 days in 2013 and 13.7 days in 2014, with a significant portion of respondents not knowing the exact time frame.
B3. How did your behavior change? Behavioral Changes 2012 2013 2014 Sample Size 66 65 58 I turn off my lights now 48% 48% 52% More aware of power usage/saving energy 18% 34% 17% I turn off appliances - 8% 14% Reduce water consumption/Not w...
AI summary The text presents data on behavioral changes related to energy usage and conservation from 2012 to 2014. It includes statistics on actions such as turning off lights, using energy-efficient appliances, and participating in ENSC programs. The data also includes satisfaction levels with washing clothes in cold water in 2013 and 2014.
R2. Which energy efficiency products would you like to have had installed through the Residential Direct Installation program? Energy Efficiency Products that Respondents Would Have Liked Installed 2012 (#) 2013 (#) 2014 (#) Sample Size 10...
AI summary The Residential Direct Installation program's survey data shows that respondents preferred heat pumps/geothermal, LED light bulbs, and solar panels as energy efficiency products. The survey also indicates that most respondents live in single-family detached houses.
P2. How did you find out about this program? Sources of Program Awareness 2014 Pilot Participants Sample Size 177 TOTAL ADVERTISING 24% Mailings from ENSC 16% Newspaper 6% ENSC Website 5% Radio - Co-worker, family, friend 54% ENSC staff/DA...
AI summary The text discusses how participants in the 2014 pilot program learned about it, with the majority (54%) finding out through co-workers, family, or friends, followed by 24% through total advertising and 16% through mailings from ENSC.
P6. What were those concerns? Concerns about the Program 2014 Pilot Participants (#) Sample Size 5 That I'd have to pay some fees 2 That the products offered might pose health risks 1 Wouldn't save energy/be more energy efficient 1 Wouldn'...
AI summary Participants in the 2014 pilot program expressed concerns about fees, health risks, and the effectiveness of the program. However, satisfaction levels with the program were generally high, with over 90% of participants expressing satisfaction with aspects such as the quality of work, communication, and energy conservation measures.
S3. What was the most important reason why you were satisfied with the program overall? Anything else? Reasons for Satisfaction 2014 Pilot Participants Sample Size 163 I liked the installer who visited the home 29% Lowered energy bill 27%...
AI summary Participants in the 2014 pilot program expressed satisfaction primarily due to the installer's service, reduced energy bills, and energy savings. Dissatisfaction was linked to dissatisfaction with installed products, lack of expected results, and poor installer experiences.
S8. Using a 5-point scale, where '1' is very difficult and '5' is very easy, how would you rate the process to apply to the program? Program Application Process 2014 Pilot Participants Sample Size 172 5 - Very easy 83% 4 16% 3 1% 2 1% 1 -...
AI summary The application process for the program was rated as very easy by 83% of 2014 pilot participants, with only 1% finding it very difficult. Most respondents (36%) did not know the time between first contact with ENSC and product installation, with a mean of 12.8 days. A few participants found the program application process difficult due to lack of information or unmet expectations.
PP1a/b. According to our records, your household received information during the visit from the installer about the benefits of washing your clothes in cold water. The installer would have spoken to you about your clothes washing behavior...
AI summary The text asks the respondent if they recall a conversation with an installer about the benefits of washing clothes in cold water and changing their washing temperature to cold.
PP3. Thinking of your OVERALL experience with this project aimed at encouraging you to wash your clothes in cold water, including any services or energy efficiency advice or tips provided, how satisfied were you overall with this project o...
AI summary The text asks respondents to rate their overall satisfaction with a project aimed at encouraging cold water laundry, including any services or energy efficiency advice they received, on a scale from 1 to 10.
2014 Pilot Participants Satisfaction with Pilot Project Sample Size % Overall Experience 146 72% Don't know removed from calculations Percentage of respondents who gave a rating of 10 or 9 on a scale where 10= 'Very satisfied' and 1= 'Not...
AI summary The document presents a summary of participant satisfaction with a 2014 pilot project, highlighting that 72% of respondents reported a high level of satisfaction based on their overall experience. It also includes a question regarding whether participants received information about energy-efficient products during the visit from the installer.
INTRODUCTION - V2. Hello, my name is _________ and I am with CRA (Corporate Research Associates), and we are performing an evaluation of energy efficiency services provided by Efficiency Nova Scotia Corporation. Our records indicate that y...
AI summary This introduction outlines a survey conducted by CRA on behalf of Efficiency Nova Scotia Corporation to evaluate the Residential Direct Install Program. The survey aims to gather feedback from participants who received free energy efficiency products, such as CFLs and faucet aerators, installed at their homes.
Verification and Recall [V Series] V3. I am going to read you a list of energy-efficient products that, according to our records, were installed in your house by the program: [READ WHAT IS ON RECORD (MEASURE≠0 IN THE DATABASE)]. For each o...
AI summary This section of the document contains a verification and recall process for energy-efficient products installed in a customer's home. It asks the customer to confirm whether specific items were installed and provides response options.
VOLUNTEERED - 97. (Not eligible to any other programs) - 98. (Don't know) - 99. (Refused) - S28. How likely would you be to participate in other programs offered by Efficiency Nova Scotia if your household qualified? Would you definitely,...
AI summary The text presents a survey question about participation likelihood in other programs offered by Efficiency Nova Scotia, with response options ranging from 'definitely' to 'definitely not'. It also includes response codes for 'not eligible', 'don't know', and 'refused'.
Factor (READ AND RANDOMIZE) Responses a. The free installation of energy-efficient products offered by the program Response 98 Don't Know 99 Refused 97 Not applicable b. Information or advice provided by the program advisor during the inst...
AI summary The document presents a randomized factor and responses related to a program offering free installation of energy-efficient products, information provided during installation, and previous experience with similar programs from Efficiency Nova Scotia or Nova Scotia Power. The responses include categories such as 'Don't Know', 'Refused', and 'Not applicable'.
- S4. Now I will read you a list of factors, and I would like to know how satisfied you were with each in terms of your experience with Efficiency Nova Scotia. On a scale of 1 to 10, where "1" is not at all satisfied and "10" is completely...
AI summary The text presents a survey question asking respondents to rate their satisfaction with various factors related to their experience with Efficiency Nova Scotia on a scale from 1 to 10.
Importance of RDI in 20 2013 2014 Influencing Decisions Sample Size Mean Score Sample Size Mean Score Average rating: 10= "Extremely important" , 0= "Not im portant at a all" The free installation of energy-efficient products offered by th...
AI summary The text presents survey data on the importance of RDI (likely related to energy efficiency programs) and household composition in 2013 and 2014. It highlights participant ratings of program aspects like free installation and advisor support, as well as the number of full-time residents in households.
FR2a. If you had not participated in RDI, what is the likelihood that you would have installed the same energy-efficient products that you installed through RDI? (Scale 0 to 10) FR2a = Answer x 10% PA1 Score: FR2a FR1. Did you or anyone in...
AI summary This section of the document asks participants about their likelihood of installing energy-efficient products without the RDI program, their prior plans, and the influence of the program on their decisions. It also includes scoring mechanisms to assess free-ridership based on responses.
APPENDIX X INTERNAL SPILLOVER METHODOLOGY Internal spillover was measured using a participant survey. Participants were asked whether following their participation in the program, they bought and implemented any additional energy efficienc...
AI summary Internal spillover was measured through a survey of program participants to determine if they implemented additional energy efficiency measures outside of rebates. The influence of the program on these additional measures was quantified to calculate the portion of savings attributable to the program.
DEFINITIONS Accuracy Reflects the proximity of measurements to the true value. Bias Systematic deviations of measurements from the true value. Confidence interval The estimated range of values which is likely to include the unknown populat...
AI summary This section provides definitions of key terms related to energy efficiency program evaluation, including concepts like accuracy, bias, confidence interval, distortion effects, free-ridership, gross and net energy savings, and net-to-gross ratio. These definitions support the analysis and measurement of program impacts.
Common Areas Tenant Units - › Compact fluorescent lamps (CFLs) › CFLs - › Light-emitting diode (LED) lamps › LED lamps - › Hot water tank wraps › Faucet aerators - › Low-flow showerheads › Hot water tank wraps - › LED exit signs › LED nigh...
AI summary The document lists various energy efficiency measures applicable to common areas in tenant units, including lighting upgrades, hot water tank wraps, pipe insulation, and low-flow showerheads.
Common Areas Tenant Units - › CFLs › CFLs - › LED exit signs › LED nightlights - › Hot water tank wraps › Faucet aerators - › Low-flow showerheads › Hot water tank wraps - › LED lamps › LED lamps - › Pipe insulation › Low-flow showerheads/...
AI summary The document discusses energy efficiency measures in common areas of tenant units, including the use of LED lamps, low-flow showerheads, and pipe insulation. It outlines funding sources for RP&C, noting that savings from tenant unit installations are attributed to RP&C, while common-space savings are attributed to BES. RP&C aimed for 3.0 GWh of electricity savings and 0.7 MW of peak demand savings in 2014.
3.1 Gross Savings The quantities of products installed under RP&C in 2014 were documented in the tracking system. A total of 59,168 products were installed in 2,895 condos and apartments. For each type of product, ENSC uses a unitary savin...
AI summary This section discusses the installation of energy efficiency products under the Rental Properties and Condos Service (RP&C) in 2014, with a total of 59,168 products installed across 2,895 units. Efficiency Nova Scotia (ENSC) uses unitary savings values based on 2013 evaluation results to calculate gross savings.
3.1.1 CFLs In the RP&C tracking sheet, the quantity of CFLs installed is recorded by lamp type (e.g., regular, dimmable or speciality) and wattage. The following 7 types of CFL are documented in the 2014 tracking sheet: - › 13-watt CFLs -...
AI summary The RP&C tracking sheet documents the installation of 7 types of CFLs, categorized by wattage and type (e.g., regular, dimmable, specialty), with examples including 13-watt, 14-watt dimmable, and 14-watt bathroom globe CFLs.
Displaced Wattage The displaced wattages were estimated based on: (1) the 2013 on-site visit results; and (2) a comparison of the wattage value of each type of CFL installed through the program with the average equivalent wattage (as repre...
AI summary The displaced wattages were estimated using 2013 on-site visit results and a comparison of CFL wattage values with the average equivalent wattage of incandescent lamps replaced through the program.
Figure 1: Light Output Equivalency for Incandescent Lamps and CFLs4 LIGHT OUTPUT EQUIVALENCY INCANDESCENT BULBS (WATTS) MINIMUM Light Output (Lumens) COMMON ENERGY STAR QUALIFIED LIGHT BULBS (WATTS) 40 450 9 то 13 60 800 13 TO 15 75 1,100...
AI summary Figure 1 provides a comparison of light output equivalency between incandescent bulbs and compact fluorescent lamps (CFLs), showing the wattage and lumens for various bulb types. The table helps in understanding the energy efficiency of CFLs compared to traditional incandescent bulbs.
Unitary Savings Based on the displaced wattage values and the hours of operation described above, the table below presents the unitary savings values used in the tracking sheet for each category of CFL. Type of CFL Old Wattage (W) New Watt...
AI summary The text provides unitary savings values for various types of compact fluorescent lamps (CFLs), calculated based on displaced wattage and hours of operation, used in the tracking sheet for energy efficiency programs.
Displaced Wattage ENSC assumes that 10-watt LED A-lamps (dimmable or regular) replace 60-watt incandescent lamps, and that 5-watt LED chandeliers replace 40-watt incandescent lamps. This results in displaced wattages of 50 W and 35 W, resp...
AI summary ENSC assumes that 10-watt LED A-lamps replace 60-watt incandescent lamps and 5-watt LED chandeliers replace 40-watt incandescent lamps, resulting in displaced wattages of 50 W and 35 W, respectively.
Hours of Operation LED chandeliers and dimmable A-lamps are only installed indoors, and therefore, the value of 2.68 hrs/day was applied. For the 10-watt LED A-lamp, the installation location was not tracked. Therefore, the 2014 Atlantic S...
AI summary The document calculates the average daily operation hours for 10-watt LED A-lamps by considering the proportion installed indoors (88%) and outdoors (12%), using values of 2.68 hrs/day and 3.6 hrs/day respectively, resulting in an average of 2.8 hrs/day.
Unitary Savings Based on the displaced wattage values and the hours of operation described above, the table below presents the unitary savings values used in the tracking sheet for each category of LED lamp.
AI summary The text discusses unitary savings values for LED lamps, calculated based on displaced wattage and hours of operation, as presented in a tracking sheet for different categories of LED lamps.
Table 4: Unitary Savings Values for Each Type of LED Lamp Type of LED Old Wattage (W) New Wattage (W) Displaced Wattage (W) Hours of Operation (hrs/day) Tracked Unitary Savings Value (kWh/year) 10W LED A-lamp 60.0 10.0 50.0 2.80 51.1 10W L...
AI summary Table 4 presents unitary savings values for different types of LED lamps, showing the energy savings achieved by replacing traditional bulbs with LED alternatives. The table includes data on old and new wattage, displaced wattage, hours of operation, and tracked unitary savings in kWh per year.
For the LED nightlights installed through RP&C, ENSC uses a unitary savings value of 29.3 kWh/year. The table below shows the variables used to calculate the unitary savings.
AI summary The document discusses the unitary savings value of 29.3 kWh/year for LED nightlights installed through the Rental Properties and Condos Service (RP&C) by Efficiency Nova Scotia (ENSC), along with variables used in the calculation.
Table 5: Tracked Unitary Savings Value for LED Nightlights Parameter Value Old Wattage (incandescent nightlight) 7.0 W New Wattage (LED nightlight) 0.3 W Average Displaced Wattage 6.7 W Operating Time 12 hrs/day Unitary Savings 29.3 kWh/ye...
AI summary Table 5 presents the tracked unitary savings value for LED nightlights, comparing old and new wattage, average displaced wattage, operating time, and resulting unitary savings in kWh per year. The section then transitions to a discussion of faucet aerators under subsection 3.1.2.
For all faucet aerators installed through RP&C (whether in the kitchen or the bathroom), ENSC uses an average unitary savings value of 122 kWh/year. This value comes from a custom calculation detailed in 2013 MURB Evaluation Report, which...
AI summary ENSC uses an average unitary savings value of 122 kWh/year for faucet aerators installed through RP&C, based on a 2013 MURB Evaluation Report that references various sources to estimate hot water consumption and flow rate reduction.
Table 6: Unitary Savings Value for Faucet Aerators Parameter Value Source Housing Type Multi-Family - Baseline Flow Rate 1.2 gpm 2003 Aquacraft Study 6 Low-flow Rate 0.94 gpm 2003 Aquacraft Study Number of People per Household (RP&C) 1.8 2...
AI summary Table 6 presents the unitary savings value for faucet aerators, detailing parameters such as baseline flow rates, water usage, and energy efficiency. The data is sourced from various studies and conventions, highlighting the energy savings achieved through reduced water usage in multi-family housing.
3.1.3 Low-flow Showerheads On the basis of a custom calculation that took into account the reduction in flow rate, the number of people per household and the baseline volume of hot water used per person, ENSC established the unitary saving...
AI summary ENSC calculated the energy savings from low-flow showerheads based on factors like flow rate reduction, household size, and baseline hot water usage, determining a unitary savings of 330 kWh/year.
Table 7: Unitary Savings Values for Low-flow Showerheads 10 Parameter Value Source Housing Type Multi-Family 2013 Pennsylvania Public Utility Commission TRM11 Baseline Flow Rate 2.5 gpm 2013 Pennsylvania Public Utility Commission TRM Low-f...
AI summary Table 7 provides unitary savings values for low-flow showerheads, including parameters such as baseline and low-flow rates, water usage, and energy efficiency. It references various sources including the Pennsylvania Public Utility Commission TRM and the Engineering Toolbox website.
3.1.5 Hot Water Tank Wraps Two types of tank wraps are installed under RP&C, and their respective thermal resistance values are 0.90 m2 ·°C/W and 1.21 m2 ·°C/W. To calculate the unitary savings value, the equation used by both the OPA and...
AI summary The document discusses the calculation of unitary savings for hot water tank wraps under the Rental Properties and Condos Service (RP&C). It references formulas used by the Ontario Power Authority (OPA) and the Pennsylvania Public Utility Commission (PUC) Technical Reference Manuals (TRMs).
Where: - › Ubase: Thermal transmittance per area unit of water heater prior to adding tank wrap [W/m 2 .°C] - › Abase: Surface area of storage tank prior to adding tank wrap [m 2 ] - › Uinsul: Thermal transmittance per area unit of water h...
AI summary This section introduces variables and equations related to thermal transmittance and heat transfer calculations for water heaters with and without tank wraps, based on product specifications and thermal resistance equations.
Table 8: Unitary Savings Values for RSI-1.21 and RSI-0.90 Hot Water Tank Wraps Parameter Value Source Te 21°C Assumption for standard ambient temperature indoors Ti 60°C Natural Resources Canada13 HOU 8,760 hrs/year Assumption ηheater 97%...
AI summary Table 8 provides unitary savings values for RSI-1.21 and RSI-0.90 hot water tank wraps, including parameters like ambient temperature, heater efficiency, and energy consumption calculations. The data is used to assess energy savings from insulation improvements.
Table 9: Percentage of Products Installed and Installation Rate Type of Product Installation Rate Regular CFL (13W and 23W) 95% Dimmable CFL (16W) 100% LED Nightlight 100% Faucet Aerator 95% Low-Flow Showerhead 92% Low-Flow Showerwand 100%...
AI summary Table 9 outlines the installation rates of various energy-efficient products, showing high adoption levels for items such as CFLs, LED nightlights, and low-flow showerheads. Section 3.1.7 discusses validated gross savings, which is likely related to the energy and cost savings achieved through these installations.
The annual gross savings tracked for the products installed in 2014 were validated by the Evaluator and are presented in Table 10. Overall, the gross energy and peak demand savings amount to 3.325 GWh and 0.775 MW at the meter, respectivel...
AI summary The document validates annual gross savings from energy efficiency programs in 2014, showing 3.325 GWh and 0.775 MW at the meter. Using a line loss factor of 1.099, the savings at the generator were calculated as 3.655 GWh and 0.852 MW, based on data provided by Nova Scotia Power.
Table 10: Validated Gross Energy and Peak Demand Savings by Product Ty f Pr du t p e o o c 1 3- W t C t a F L 1 3- W t C t a L O F do t u or 1 4- W t C t a F L 1 4- W t C t a L O F do t u or 2 3- W t C t a F L 2 3- W t C t a L O F do t u o...
AI summary Table 10 presents validated gross energy and peak demand savings by product type, including data on the number of units and installation rates for various lighting and heating products. The table includes metrics like CFL, LED, and DHW, with percentages indicating installation rates.
(Continued) Type of Product 10-Watt LED A- Lamp 10-Watt LED Dim. A-Lamp LED Nightlight Low-Flow Faucet Aerator Low-Flow Shower- head Low-Flow Shower- wand Pipe Insulation Tank Wrap Hot Water Tank Wrap (RSI-1.21) Energy Savings Number of Un...
AI summary The document presents a detailed table of energy savings data for various products, including LED lamps, low-flow faucets, and insulation materials. It includes metrics such as the number of units installed, energy savings in GWh, and peak demand savings in MW. The data provides a comprehensive overview of the impact of these energy efficiency measures.
3.2 Interactive Effects Interactive effects occur on a building's space conditioning systems after the implementation of energy efficiency measures, such as lighting upgrades. These upgrades impact the energy consumption of the heating and...
AI summary This section discusses interactive effects on building space conditioning systems following energy efficiency measures, such as lighting upgrades. The analysis focuses on how replacing incandescent lighting with CFLs or LEDs affects heating and cooling loads and references a 1992 study by ADS for Hydro-Québec using DOE-2 software to simulate scenarios of interactive effects.
Table 11: Interactive Effects Calculation for Lighting Products Parameter % of Residences Interactive Effects17 Electric heating with air-conditioning 25% × 18% = 5% -54.4% Electric heating without air-conditioning 25% × 82% = 20% -58.0% N...
AI summary Table 11 calculates interactive effects for lighting products based on electric heating and air-conditioning presence. Interactive effects are applied only to indoor installations, except for the 10-watt LED A-lamp. These effects influence space conditioning loads due to changes in waste heat from lighting.
Table 12: Interactive Effects Factor for Pipe Insulation and Hot Water Tank Wraps Parameters % of Residences19 Interactive Effects During Heating Period Interactive Effects During Cooling Period Electric heating with air-conditioning 5% -1...
AI summary Table 12 presents the interactive effects factor for pipe insulation and hot water tank wraps across different heating and cooling scenarios. It shows a weighted interactive effects factor of -15.5%, with significant variations depending on the presence of electric heating and air-conditioning systems.
Table 13: Validated Net Energy and Peak Demand Savings by Product Type of Product 13-Watt CFL 13-Watt CFL Outdoor 14-Watt CFL 14-Watt CFL Outdoor 23-Watt CFL 23-Watt CFL Outdoor 14-Watt Dim. CFL 15-Watt Dim. CFL 16-Watt Dim. CFL 14-Watt G2...
AI summary Table 13 presents validated net energy and peak demand savings by product type, including energy savings at the meter and generator, interactive effects, NTGR, line loss, and peak demand savings. The table includes various products such as CFLs and LEDs, with associated metrics like gross and net energy savings and peak demand savings.
NOTE FOR PROGRAMMER: DO NOT PUT THE NUMBER OF EACH MEASURE - a) CFL bulbs - b) LED bulbs - c) LED Exit Signs - d) Pipe insulation/Tank wraps - e) Low-flow showerheads or showerwands - f) Faucet aerators - V4. [FOR EACH OF V3a to V3e = NO a...
AI summary The text outlines a list of energy efficiency measures and includes a verification process to confirm if these measures have been installed in a building. It asks respondents to verify installation records for items like CFL bulbs, LED bulbs, and pipe insulation.
7 Facebook or other social media 8 Participation in another Efficiency Nova Scotia program 97. 98. (Other [SPECIFY]) Cannot recall CS2. 1 2 3 you only work with a third-party contractor or service delivery agent? Directly with Efficiency N...
AI summary This section of the document outlines a survey related to participation in Efficiency Nova Scotia programs, including questions about program satisfaction, contact methods, and experience with Efficiency Nova Scotia employees and contractors.
CODE ONE ONLY - 1 Definitely - 2 Probably - 3 Probably not - 4 Definitely not - 8. [VOLUNTEERED] Don't know/No answer - S10. Thinking of when you first contacted ENSC about the program, or ENSC contacted you, how long, in days, was it befo...
AI summary This section of the document presents a questionnaire related to customer engagement with Efficiency Nova Scotia (ENSC), focusing on the time between initial contact and product installation. It includes response options and a specific question about the number of days between contact and installation.
IF RESPONDENT HAS DIFFICULTY SPECIFYING AN FR2dM1 ANSWER IN MONTHS, READ: Would it have been ... - 1 Less than 6 months? - 2 Within 6 months to less than 1 year later? - 3 1 to less than 2 years later? - 4 2 to less than 3 years later? - 5...
AI summary The text presents a series of questions aimed at understanding customer behavior and willingness to pay for energy efficiency measures. It includes options for respondents to indicate how long it would take for them to pay for a measure and whether they would have paid the full cost if Efficiency Nova Scotia had not installed it for free.
IF RESPONDENT HAS DIFFICULTY SPECIFYING AN FR2dM2 ANSWER IN MONTHS, READ: Would it have been ... 1 Less than 6 months? 2 Within 6 months to less than 1 year later? 3 1 to less than 2 years later? 4 2 to less than 3 years later? 5 3 to less...
AI summary The text presents a series of questions related to the timing of an action and the willingness to pay for an energy efficiency measure, indicating a regulatory or survey context involving Efficiency Nova Scotia.
Factor (READ AND RANDOMIZE) Responses a. The free installation of energy-efficient products offered by the program Response 98 Don't Know 99 Refused b. Information or advice provided by program staff throughout the upgrade process Response...
AI summary The text presents responses to questions about customer experiences with energy efficiency programs, including free installation of products, information provided by program staff, and previous experience with similar programs. The data includes responses such as 'Don't Know' and 'Refused'.
Importance of Factors in Influencing Decision-making 2012 (#) 2013 (#) 2014 (#) Sample Size 9 15 14 Mean (0 = Not at all important; 10 = Extremely important) Free installation of energy-efficient products offered by the program 9.3 9.1 9.6...
AI summary The document presents data on the importance of factors influencing decision-making in energy efficiency programs from 2012 to 2014, including the mean ratings of factors like free installation and program staff support. It also includes survey results on direct contact with Efficiency Nova Scotia (ENSC) versus third-party contractors.
- CS4. Now I will read you a list of factors, and this time I would like to know how satisfied you were with each in terms of your experience with Efficiency Nova Scotia. On a scale of 1 to 10, where "1" is not at all satisfied and "10" is...
AI summary The text presents a survey question asking respondents to rate their satisfaction with various factors related to their experience with Efficiency Nova Scotia on a scale of 1 to 10.
- CS5. Now, using the same 10 point scale, how satisfied are you with Efficiency Nova Scotia's overall performance in working with your company? Sample Size 2012 Satisfied Sample Size 2013 Satisfied Sample Size 2014 Satisfied Mean (1=Not a...
AI summary The text presents a survey question regarding satisfaction with Efficiency Nova Scotia's performance in working with companies, along with sample sizes and mean satisfaction scores from 2012 to 2014.
CS28. Based on your company's experience working with Efficiency Nova Scotia and its third-party contractors, would you definitely, probably, probably not, or definitely not participate in other programs offered by Efficiency Nova Scotia?
AI summary The question asks about the likelihood of participation in other programs offered by Efficiency Nova Scotia, based on the company's experience working with Efficiency Nova Scotia and its third-party contractors.
Would Participate in Other ENSC Programs 2012 (%) 2013 (%) 2014 (#) Sample Size 29 36 19 Definitely 76% 61% 18 Probably 17% 33% 1 Probably not 7% 3% - Definitely not - 3% - \ Don't know/refused have been removed from calculation
AI summary The table presents participation rates in other ENSC programs across 2012, 2013, and 2014, showing a decline in the percentage of respondents who would definitely participate, along with changes in sample size and response distribution.
\ \ Number of respondents who gave a rating of completely satisfied or mostly satisfied'; Don't know removed from calculations \ \ Base is not full sample size because of programming error CS29. And based on your experience, how likely are...
AI summary The text presents a survey question asking respondents how likely they are to recommend Efficiency Nova Scotia's programs to other businesses, with options ranging from 'definitely' to 'definitely not'. It also includes notes about data calculations and a programming error affecting the sample size.
Would Recommend to Other Businesses 2012 (%) 2013 (%) 2014 (#) Sample Size 30 36 19 Definitely 80% 75% 18 Probably 13% 17% 1 Probably not 7% 6% - Definitely not - 3% - Don't know/refused have been removed from calculation \ Don't know/refu...
AI summary The table presents data on the likelihood of recommending energy efficiency programs to other businesses across three years, showing a slight decline in the percentage of respondents who would definitely recommend the programs from 2012 to 2013, with a significant drop in the sample size in 2014.
S10. Thinking of when you first contacted ENSC about the program, or ENSC contacted you, how long, in days, was it before the first products were installed in your building(s)? Length of Time to Have Products Installed 2014 (#) Sample Size...
AI summary This question asks respondents how many days passed between first contacting ENSC about a program and the installation of the first products in their buildings. The data shows an average of 29 days with a sample size of 13, and responses are categorized by time intervals.
ABBREVIATIONS DHW Domestic Hot Water ENSC Efficiency Nova Scotia Corporation NTGR Net-to-Gross Ratio
AI summary The text provides a list of abbreviations used in the document, including DHW for Domestic Hot Water, ENSC for Efficiency Nova Scotia Corporation, and NTGR for Net-to-Gross Ratio. An image is referenced but not described.
2.1 Gross Savings The tracking sheet provided for 2014 contained a total of 33 projects offsetting electric energy consumption, including 30 systems used for DHW and three for air space heating. Based on the 2013 evaluation, systems combin...
AI summary The 2014 tracking sheet included 33 energy-saving projects, with 30 focused on domestic hot water and three on space heating. ENSC calculates energy savings using RETScreen analyses and standardized variables when specific data is unavailable.
Domestic Hot Water Heating ENSC uses the following conditions to establish the model variables for solar DHW systems.
AI summary ENSC uses specific conditions to establish model variables for solar domestic hot water systems.
Air Space Heating Systems ENSC uses the following conditions as the model variables for solar space heating systems.
AI summary The document discusses the conditions used by ENSC as model variables for solar space heating systems. It outlines the parameters that are considered in the modeling process for these systems.
2.1.2 Validated Gross Savings The gross annual savings for all categories of equipment installed through Solar are presented in Table 4. The results are based on the calculated RETScreen savings found in the tracking sheet and the adjustme...
AI summary The validated gross savings for Solar installations are 0.0864 GWh at the meter and 0.0950 GWh at the generator, using a 1.100 line loss factor provided by Nova Scotia Power. Peak demand savings for Solar are assumed to be nil for 2014.
Table 4: Validated Gross Savings Measure Category DHW Air Space Heating Total Program Tracking Sheet Number of Projects 30 3 33 Tracked Energy Savings (GWh) 0.0806 0.0035 0.0841 Validated Energy Savings Adjustment Ratio 1.028 1.000 - Total...
AI summary Table 4 presents validated gross savings from energy efficiency measures, showing energy savings tracked and adjusted for factors like line loss and adjustment ratios, categorized by measure type such as domestic hot water and air space heating.
ABBREVIATIONS ENSC Efficiency Nova Scotia Corporation LED Light-Emitting Diode LHLE LED Holiday Light Exchange NTGR Net-to-Gross Ratio OPA Ontario Power Authority PG&E Pacific Gas and Electric Company TRM Technical Reference Manual
AI summary This section provides a list of abbreviations used in the document, including Efficiency Nova Scotia Corporation, Light-Emitting Diode, LED Holiday Light Exchange, Net-to-Gross Ratio, Ontario Power Authority, Pacific Gas and Electric Company, and Technical Reference Manual.
垂 ECONOLER Precision The extent to which repeated measures agree with one another. The error in measurement due to the fact that measures are taken from a Random sampling error subset of the population and not the entire population. Sample...
AI summary The text defines key terms related to energy efficiency programs, including precision, random sampling error, sample size, tracked savings, and unitary savings. These terms are used in the context of program tracking and evaluation by Efficiency Nova Scotia (ENSC).
Table 1: Comparison of Tracked and Evaluated Savings at the Generator Initial Gross Savings Gross Savings with Interactive Effects NTGR Net Savings Energy Savings Tracked Savings from ENSC 0.246 GWh 0.246 GWh 1.00 0.246 GWh Evaluation Resu...
AI summary The table compares tracked and evaluated energy and peak demand savings from the LED Holiday Light Exchange (LHLE) program. Evaluated net energy savings are lower than tracked savings due to a reduction in unitary savings value and an interactive effect factor not considered in the tracked data. These findings are based on a 2014 ENSC in-field survey and are deemed reliable.
2 IMPACT EVALUATION The purpose of the impact evaluation is to determine the gross and net savings of LHLE in 2014. To this end, Econoler reviewed the unitary savings calculations of ENSC by comparing them with those made by other jurisdic...
AI summary The impact evaluation assesses the gross and net energy savings of the LED Holiday Light Exchange (LHLE) in 2014. Econoler reviewed Efficiency Nova Scotia's (ENSC) unitary savings calculations and updated assumptions based on a 2014 in-field survey. Gross energy and peak demand savings were calculated, and net savings were determined by considering the interactive effects of replacing traditional lights with LED lights.
2.1.1 Tracked Unitary Savings Value The average unitary savings value estimated for each set of LED lights exchanged is 35.2 kWh, and the unitary demand savings value is estimated at 176 W by ENSC. These values have been used to estimate t...
AI summary The average unitary savings value for LED lights exchanged is 35.2 kWh, with a unitary demand savings value of 176 W, as estimated by ENSC. These values have been used to calculate the gross energy and peak demand savings from the LHLE since 2007, based on specific assumptions.
Number of Sets Replaced Through LHLE, ENSC offers one set of LED lights in exchange for two sets of traditional incandescent lights—there is a limit of one set of LED holiday lights per person. Consequently, ENSC calculates the unitary sav...
AI summary ENSC's LHLE program exchanges one set of LED lights for two sets of traditional incandescent lights, with a limit of one LED set per person. ENSC assumes customers will replace returned incandescent sets with new LED sets, but this assumption is considered conservative as customers often return more than two sets and may use only the new LED set provided.
Project No. 5870 4 1 Precision refers to how close the measured values are to each other. It does not, however, take into consideration how close the measured value is to the true value, which would be defined as accuracy . random sampling...
AI summary The text discusses the precision and accuracy of measurements, noting that precision refers to the consistency of measured values, not their closeness to the true value. It also mentions a survey with a ±4.7% margin of error at a 90% confidence interval, which is considered reliable. Results from a previous ENSC survey and a literature review are referenced.
Table 4: Literature Review of Old Incandescent Sets Type of Light Proportion of Each Category Quantity of Lamps per Set Source Large Incandescent 50 % 50 lamps/set Pennsylvania Public Utility Commission Technical Mini Incandescent 50 % 50...
AI summary Table 4 presents a literature review of old incandescent light sets, detailing the type of light, proportion in each category, quantity of lamps per set, and sources. The Evaluator relied on an in-field survey conducted in 2014 by ENSC and other studies.
Displaced Wattage Based on former in-field observations, ENSC established the percentages of old sets that were returned among three different types of incandescent light sets. The lamp wattages used for the different types of old sets tha...
AI summary The document discusses the validation of wattage values for old incandescent light sets based on various studies and sources, including Pacific Gas and Electric Company, BC Hydro, Ontario Power Authority, and the Technical Reference Manual from the Pennsylvania Public Utility Commission and California Municipal Utilities Association. The wattage values used by ENSC for large and mini incandescent bulbs are deemed appropriate.
Annual Usage ENSC used an annual usage assumption of 40 days per year, which represents an average value of all the studies mentioned below. While BC Hydro10 and the Ontario Power Authority (OPA) assume an annual usage of 31 days, which co...
AI summary ENSC uses an annual usage assumption of 40 days per year for LED holiday lighting, based on studies from various jurisdictions. This assumption was revised in 2013 to reflect higher daily usage of 5.8 hours per day, as found in a survey conducted by ENSC.
Table 6: Revised Unitary Savings Estimate for Each Set of LED Lights Exchanged Parameters Values Proportion of Old Large Incandescent Sets Returned (35 lamps per set) 20% Proportion of Old Mini Incandescent Sets Returned (50 lamps per set)...
AI summary Table 6 provides a detailed breakdown of the revised unitary savings estimate for each set of LED lights exchanged, including wattage calculations, energy savings, and demand savings. It outlines the proportion of old incandescent sets returned and the corresponding energy and demand savings achieved through replacement with LED sets.
2.1.4 Total Gross Savings The gross savings of LHLE for 2014 were calculated by multiplying the unitary savings value of 29 kWh established during this evaluation with the number of LED sets exchanged through LHLE in the fall of 2014. For...
AI summary The gross savings from the LED Holiday Light Exchange (LHLE) in 2014 were calculated using a unitary savings value of 29 kWh and the number of LED sets exchanged. Total gross energy and peak demand savings were 0.184 GWh and 0.396 MW at the meter, and 0.202 GWh and 0.435 MW at the generator level after applying a line loss factor of 1.100.
Table 8: Interactive Effects Factor for LHLE Parameters % of Residences Interactive Effects Using Electric Heating – indoor seasonal LED lights 33% × 15% = 5% -100% Using Electric Heating – outdoor seasonal LED lights 33% × 85% = 28% 0% No...
AI summary Table 8 presents the interactive effects factor for the LED Holiday Light Exchange (LHLE) in 2014, showing a weighted interactive effects factor of -5 percent. The table breaks down the effects based on the use of electric heating and seasonal LED lights in different percentages of residences.
Table 10: Comparison of Tracked and Evaluated Savings at the Generator Initial Gross Savings Gross Savings with Interactive Effects NTGR Net Savings Energy Savings Tracked Savings from ENSC 0.246 GWh 0.246 GWh 1.00 0.246 GWh Evaluation Res...
AI summary Table 10 compares tracked and evaluated energy and peak demand savings at the generator. Evaluated savings are lower than tracked savings due to a reduction in the unitary savings value from 35.2 kWh to 29 kWh, influenced by changes in the proportion of incandescent sets replaced and a reduction in average wattage.
ABBREVIATIONS CATI Computer-assisted Telephone Interviewing CBSM Community-based Social Marketing CSA Canadian Standard Association CRA Corporate Research Associates DA Delivery Agent DSM Demand-side Management EER Energy Efficiency Ratio...
AI summary This section outlines abbreviations used in the document, including terms related to energy efficiency, research, and program management. Key entities such as Efficiency Nova Scotia and the Ontario Power Authority are referenced.
Influence of HER on Behavioural Changes Participants in the web-based component of HER were first asked a number of survey questions about energy efficiency behaviours to find out whether they had adopted one or more of them in the 12 mont...
AI summary Participants in the web-based HER program reported low influence ratings (1.6 to 4.3 on a 10-point scale) regarding energy efficiency behaviors. However, analysis showed that some behaviors, such as hanging laundry to dry and reducing shower time, increased after participation in the program, indicating some behavioral changes.
Energy Savings To calculate the net savings of HER in 2014, the Econoler team first reviewed the methodology used by Opower for calculating the paper-based component savings. The energy savings achieved by the paper-based component are con...
AI summary The evaluation of the Home Energy Report (HER) program found that it generated net energy savings of 34.711 GWh and demand savings of 3.938 MW over 21 months (April 2013 to December 2014). The savings were calculated using a control group comparison for the paper-based component and a self-declared approach for the web-based component.
Recommendations Overall, the Econoler team finds that the paper-based component of HER has succeeded in achieving the expected results in terms of changing participants' electricity consumption behaviour. The impact of the web-based compon...
AI summary The Econoler team found that the paper-based component of the Home Energy Report (HER) successfully changed participants' electricity consumption behavior, while the web-based component's impact was harder to evaluate. Specific recommendations are made to optimize HER, in addition to general recommendations for ENSC program components from the 2014 DSM programs.
2014 HER-R1. Explain in greater detail the characteristics of HER in the program documentation. Designed to influence and change participants' electricity use behaviour, HER is different from other program components undertaken by ENSC. Th...
AI summary The Evaluator recommends that the Home Energy Report (HER) program documentation provide more detail on participant selection, tip recommendation processes, and available data. Confidentiality issues prevented full database review, but the methodology was deemed sound. A billing analysis is suggested to compare electricity consumption trends between treatment and control groups over five years to assess HER's impact.
2.2.1 Interview with Program Manager The Econoler team conducted one interview with the PM in September 2014 to gain a basic understanding of the program's mechanisms and delivery. Based on the information obtained from this interview, a l...
AI summary An interview was conducted with the Program Manager in September 2014 to understand the program's mechanisms and delivery. This led to the preparation of a list of questions and topics for data collection tools.
2.2.3 Survey In November 2014, CRA staff conducted a survey, using computer-assisted telephone interviewing (CATI) technology, with a total of 340 participants in HER's web-based component. The average length of the survey was 11.5 minutes...
AI summary In November 2014, CRA staff conducted a survey using CATI technology with 340 participants to gather feedback on HER, covering aspects such as behavioral changes, energy efficiency tips, participation motivations, and satisfaction with the program. Results are detailed in Appendix II and III.
2.2.4 Billing Analysis Review Econoler reviewed the methodology used by Opower to establish the energy savings of the paper-based participants by making an analysis of the billing data of the treatment group and the control group. First, E...
AI summary Econoler evaluated Opower's methodology for determining energy savings from paper-based participants by analyzing billing data from treatment and control groups using regression analysis.
3 PROCESS EVALUATION This section presents the findings from the process evaluation of HER, which has been carried out on the basis of the information gathered from the documentation and an interview with the PM.
AI summary This section presents the findings from the process evaluation of the Home Energy Report (HER), based on documentation and an interview with the Program Manager (PM).
3.2 Program Documentation As part of the evaluation, the Evaluator analyzed the program documentation and worked together with the PM to improve and revise the content of certain program documents. A number of changes have already been mad...
AI summary The Evaluator reviewed program documentation for the Home Energy Report (HER) and recommended updates to improve clarity and completeness. Key recommendations include updating participant numbers, adding home age criteria for group selection, and enhancing the tip library with an index and categorization. The Evaluator also suggested removing the gross savings calculation from the evaluation plan and ensuring all available data is included.
4.1.1 Energy Efficiency Appliance Purchases and Behaviours Nearly four in ten participants (38%) purchased an energy-efficient appliance in the last year, with most of these being clothes washers (31%), dishwashers (25%), and refrigerators...
AI summary The section discusses energy efficiency appliance purchases and behaviors, noting that 38% of participants bought energy-efficient appliances, primarily clothes washers, dishwashers, and refrigerators, while 80% adopted energy-efficient behaviors.
Table 2: Energy-efficient Behaviours Adopted Energy-efficient Behaviours Adopted 2014 Sample Size 313 Turn off lights when not needed 72% Wash clothes in cold water 57% Turn off computer at night 53% Hang laundry to dry 50% Use a ceiling f...
AI summary Table 2 presents data from 2014 on energy-efficient behaviors adopted by a sample of 313 respondents. The most common behaviors include turning off lights when not needed (72%) and washing clothes in cold water (57%), while less common behaviors include using a home power monitor (6%).
Table 4: Importance of HER in Influencing Decisions Importance of HER 2014 Base Question Sample Size Mean Score Average rating: 10= "Extremely influential", 0= "No influence at all" Respondents who purchased air-conditioners HER influence...
AI summary Table 4 shows the influence of the Home Energy Report (HER) on various energy-saving behaviors, with respondents rating the HER's impact on decisions such as purchasing energy-efficient appliances and reducing water usage. Ratings range from 1.6 to 4.3, indicating varying degrees of influence.
Table 5: Likelihood of Purchasing/Undertaking Activity without HER Influence of HER 2014 Base Question Sample Size Definitely/ Probably Respondents who purchased air-conditioners Likelihood of purchasing energy efficient air-conditioner wi...
AI summary The table shows that most respondents are likely to undertake energy-efficient behaviors even without the Home Energy Report (HER). For example, 94% of respondents who hung laundry to dry continued to do so without HER. The text notes that behavior changes occurred following HER participation, with some behaviors increasing in frequency, such as hanging laundry to dry.
Only a minority of HER participants spoke with ENSC contact centre representatives (26%). Among this minority of participants, there were high levels of satisfaction with various aspects of service, including the service attitude (92%), kn...
AI summary Only 26% of HER participants interacted with ENSC contact centre representatives, but those who did reported high satisfaction with service aspects. Most participants would recommend ENSC programs, though some suggested improvements like more detailed information and house-specific content in the HER.
Table 7: Willingness to Recommend Programs 2014 Would Recommend ENSC Programs to Others Would Participate in Other ENSC Programs Sample Size 247 244 Definitely 53% 51% Probably 39% 43% Probably not 5% 4% Definitely not 3% 1% "Don't know/re...
AI summary Table 7 presents data on customer willingness to recommend and participate in Efficiency Nova Scotia Corporation (ENSC) programs. The data shows high levels of recommendation and participation, with over half of respondents indicating they would definitely recommend ENSC programs to others.
5 IMPACT EVALUATION FOR PAPER-BASED COMPONENT The objective of the 2014 impact evaluation of HER's paper-based component was to determine the net energy savings. Both electrical energy and demand savings were estimated by analyzing the sav...
AI summary The 2014 impact evaluation of the Home Energy Report's paper-based component aimed to determine net energy and demand savings using Opower's methodology. The evaluation concluded that savings calculated are accepted as 'net' without considering free-ridership effects.
5.1 Methodology Review The approach to the impact evaluation involved reviewing the billing analyses performed by Opower. The savings are established by comparing the consumption of a group of participants (treatment group) to that of a gr...
AI summary The impact evaluation methodology involved reviewing billing analyses conducted by Opower, comparing the consumption of a treatment group to a control group with similar attributes to establish savings.
Billing Analysis Opower estimated the savings using a panel data regression model, which involved following and comparing the same individuals over time, as well as comparing different individuals at a given point in time through regressio...
AI summary The document discusses the use of panel data regression models by Opower and Econoler to estimate energy savings. Opower used a 'post-only' model, while Econoler validated the results using its own regression analysis. Econoler found the Opower approach acceptable and confirmed the accuracy of the monthly savings estimates.
Energy Savings Opower makes a billing analysis every month to determine the amount of savings achieved by the participants for that month. The results of these billing analyses are presented to ENSC in a monthly report, detailing the energ...
AI summary Opower provides monthly billing analyses to ENSC, detailing energy savings from the Home Energy Report (HER) program. From April 2013 to the end of 2014, savings ranged from 0% to 2%, with an average of 1.3%. Total net energy savings at the meter were 31.362 GWh, and 34.498 GWh at the generator, using a line loss factor of 1.100 provided by Nova Scotia Power.
6 IMPACT EVALUATION FOR WEB-BASED COMPONENT The Econoler team conducted a survey with customers who signed up on the HER web portal to look at specific tips that they could have implemented because of the report. When selecting the list of...
AI summary An evaluation of the impact of a web-based component on energy savings was conducted by the Econoler team. The survey focused on customers who signed up for the Home Energy Report (HER) and assessed the effectiveness of specific energy-saving tips. Tips with low savings potential or those already covered by other programs were excluded.
6.1 Unitary Savings Values The unitary savings values were calculated using engineering formulas, as well as the data obtained from the literature and the survey with participants of the web-based component. The implementation ratio associ...
AI summary Unitary savings values were calculated using engineering formulas and survey data from participants in the web-based component. Implementation ratios for each tip were also determined based on survey results.
6.1.1 Energy-efficient Dishwasher The average consumption of all available ENERGY STAR model in 2014 is 269 kWh/year 5 , while the US Federal Standard is 307 kWh/year 5 . Therefore, the average annual savings are established at 38 kWh/year...
AI summary The section discusses the energy efficiency of ENERGY STAR-certified dishwashers, comparing their average annual consumption (269 kWh/year) to the US Federal Standard (307 kWh/year), resulting in an average annual savings of 38 kWh/year. A survey found that 32 participants purchased energy-efficient dishwashers, giving an implementation ratio of 9.4 percent.
6.1.2 Energy-efficient Room Air-conditioner In 2014, for Appliance Retirement, the Evaluator reviewed the estimated annual energy consumption and the unitary savings value for retired room air-conditioners. The average annual usage was 310...
AI summary In 2014, an evaluation of energy-efficient room air-conditioners was conducted, analyzing energy consumption and savings from retired units. The average annual energy consumption for standard units was calculated as 279 kWh, while energy-efficient units consumed 199 kWh, resulting in an average annual savings of 80 kWh. A survey found that 4.7% of participants purchased energy-efficient models.
6.1.3 Insulate Windows with Heat-shrink Film The methodology used to estimate the average savings per square meter of window due to the installation of heat-shrink film on windows is based on EC128 technical information 9 . The methodology...
AI summary The methodology for estimating energy savings from heat-shrink film on windows is based on EC128 technical information, adjusted for accuracy and simplicity. It calculates the energy ratio needed to compensate for energy losses through window leaks and determines an average energy ratio from survey data.
Methodology for Determining the Energy Ratio The energy required to heat the air escaping through window cracks is calculated using the following formula. By inputting the reduction of air flow from the cracks in the formula (instead of th...
AI summary The document outlines a methodology to calculate energy savings from installing heat-shrink film on windows by determining the energy required to heat air escaping through cracks and dividing it by the window area to estimate the energy ratio reduction.
Heating Degree Days A previous project undertaken by the Evaluator showed that the thermal balance point of a residential building usually ranged from 13°C to 17°C. So, the Evaluator recommends calculating the heating degree days with 15°C...
AI summary The text discusses the calculation of heating degree days using a reference temperature of 15°C, based on climate data from Environment Canada. It highlights the selection of three cities—Halifax, Sydney, and Truro—as representative of Nova Scotia's climate and the use of degree days below 15°C to assess energy savings from heat-shrink film on windows.
Table 12: Technical Data of the Typical Window with Heat-shrink Film Window Type Average Frame Perimeter Average Window Area Average Effective Air Leakage Area Air Leakage Reduction due to Heat-shrink Film Casement, Wood Frame, 8.79 [m] 3....
AI summary Table 12 presents technical data on windows with heat-shrink film, including average frame perimeter, window area, effective air leakage area, and air leakage reduction. Based on survey data, the average number of windows with heat-shrink film installed per residential building is 3.9, with a calculated crack area reduction of 0.000761 m².
Energy Calculation The average participant's energy savings associated with a typical window equipped with heat-shrink film in a residential building in Nova Scotia are calculated as follows: Energy $$kWh = Cp \times Q \times HDD \times 24...
AI summary The text calculates the average energy savings from using heat-shrink film on windows in Nova Scotia homes and notes that 7.4% of survey participants implemented this measure over the past year.
6.1.4 Reduce Shower Time The Econoler team calculated the unitary savings value by conducting a literature review to validate the assumptions used by the Ontario Power Authority (OPA) and by using the results from the survey. The OPA provi...
AI summary The Econoler team calculated the unitary savings value by reviewing literature and survey data, finding that participants reduced their shower time from 10 to 6.6 minutes, leading to a 6 gpd decrease in hot water use per person per day.
Table 14: Revised Unitary Savings Value for Low-flow Showerheads 14 Parameter Unitary Savings (kWh/year) Source Number of People Whose Behavioural Change is Accounted for 1 Flow Rate of the Showerhead (F) 2.4 gpm 2014 RDI Database Average...
AI summary Table 14 presents the calculation of the revised unitary savings value for low-flow showerheads based on data from the Home Energy Report (HER) and other sources, including parameters such as flow rate, shower time, and water heater efficiency.
6.1.5 Turn Off the Computer at Night It is a common knowledge that many households never turn off their computers when they are not used. Turning them off will yield energy savings. The following table shows the average off-mode and sleep-...
AI summary This section discusses the common practice of not turning off computers at night and highlights the potential for energy savings by doing so. It references average power consumption levels for basic and efficient desktops in off-mode and sleep-mode.
Table 15: Average Power Use of the "Off Mode" 17 Mode Basic Desktop Efficient Desktop Off 2.0 W 1.1 W Sleep 4.0 W 2.4 W In the survey, participants were asked to specify:
AI summary Table 15 presents the average power use of desktop computers in 'Off' and 'Sleep' modes, comparing basic and efficient models. The data highlights the energy efficiency differences between the two types of desktops.
6.1.6 Wash Clothes in Cold Water To establish the average annual savings value per participant, the following method was used: - › For both the control group and the treatment group: establishing their number of laundry loads done per week...
AI summary The average annual savings value per participant is calculated by analyzing the number of laundry loads done per week and the number of warm water loads, using survey data collected before and after participants signed up for the Home Energy Report (HER).
Water-heating Electricity per Load The percentage of hot water produced with electricity was then determined. First, the percentage of the washing machines with their own electrical resistance to heat water was obtained from the ENERGY STA...
AI summary The percentage of hot water produced with electricity for clothes washers was calculated using data from the ENERGY STAR database and Instant Savings tracking sheets. It was determined that 37% of water-heating for clothes washers uses electricity, leading to an electricity use of 0.19 kWh per laundry load.
Table 18: Average Water Usage of Clothes Washers per Year of Purchase 2005 2006 2007 2008 2009 2010 Liters per cycle 1.45 1.25 1.16 1.14 1.09 0.82 & lt;sup>21 Natural Resources Canada, Comprehensive Energy Use Database: Residential Sector...
AI summary Table 18 presents the average water usage of clothes washers per year of purchase from 2005 to 2010, showing a steady decrease in liters per cycle over time. The data is sourced from Natural Resources Canada's Comprehensive Energy Use Database.
Unitary Savings Value As previously discussed, CBSM Pilot participants achieved an average warm-water-usage reduction of 9 percent in comparison to the control group. This reduction percentage, multiplied by the water heating electricity u...
AI summary The CBSM Pilot achieved a 9% reduction in warm-water usage, leading to an annual unitary savings value of 8.6 kWh per participant. This calculation considers water heating electricity use, laundry load frequency, and implementation rate of 52.4% among 178 participants.
6.1.7 Hang Laundry to Dry To calculate the unitary savings value associated with this behaviour, the energy consumption of the clothes dryer was estimated for each laundry load. Using the results of the 2014 annual survey for RDI, the aver...
AI summary This section calculates the energy savings from hanging laundry to dry instead of using electric clothes dryers. It uses data on appliance energy consumption, survey results showing increased hanging of laundry, and the proportion of electric dryers in Nova Scotia to estimate savings of 46.5 kWh/year per participant.
6.2 Gross Savings This section presents the gross savings associated with HER's web-based component.
AI summary This section outlines the gross savings linked to the web-based component of the Home Energy Report (HER). It focuses on the financial implications of this aspect of the program.
Gross Energy Savings The annual gross savings for each category of products installed through the program are presented in Table 19 for 2013 and in Table 20 for 2014. They were calculated using the number of unique visitors to the web port...
AI summary The document presents annual gross energy savings for 2013 and 2014, calculated using unique web portal visitors, unitary savings values, and implementation ratios. Total gross energy savings at the meter were 0.444 GWh, and at the generator were 0.488 GWh, using a line loss factor provided by Nova Scotia Power.
Table 19: Web-based Component Evaluation Results for 2013 – Total Gross Energy Savings Ca f Pr du te t g or o o c y En er g y f f ic ie t e n D is hw he as r En er g y f f ic ie t e n Ro A ir om d i t io co n ne r In la te su W in do i t h...
AI summary Table 19 presents web-based component evaluation results for 2013, focusing on total gross energy savings. It includes categories such as energy-efficient dishwashers, air conditioners, windows, and other components. The table lists participation numbers and evaluation energy savings data.
Gross Peak Demand Savings Some of the tips selected to calculate energy savings might have also achieved a certain level of peak demand savings. However, additional information is required to estimate the demand savings attributable to eac...
AI summary The document discusses the calculation of gross peak demand savings, noting that while some energy-saving tips may have reduced peak demand, specific data is lacking for the HER component. The Evaluator has decided not to attribute peak demand savings to the HER component for 2014 due to its minimal impact.
Table 22: Web-based Component Evaluation Results for 2013 – Total Net Energy Savings Pr du t Ca te o c g or y En er g y f f ic ie t e n D is hw he as r En er g y f f ic ie t e n Ro A ir om d i t io co n ne r In la te su W in do w s i t h H...
AI summary Table 22 provides evaluation results for web-based components in 2013, focusing on total net energy savings. It includes metrics such as energy efficiency in dishwashers, air conditioners, windows with heat film, reducing shower time, and other categories. The data highlights energy savings across various product categories.
7 OVERALL HER RESULTS This section summarizes the overall results of the impact evaluation of HER. With the net savings achieved by both the paper-based and web-based components combined, the total energy savings amounted to 34.711 GWh, an...
AI summary The impact evaluation of HER achieved total energy savings of 34.711 GWh and peak demand savings of 3.938 MW, combining both paper-based and web-based components.
Table 24: Total Evaluated Savings at the Generator for HER Net Savings 2013 2014 Total Energy Savings Paper-based Participants (GWh) 9.162 25.336 34.498 Web-based Participants (GWh) 0.113 0.100 0.213 Total 9.275 25.437 34.711 Peak Demand S...
AI summary Table 24 presents the total evaluated savings at the generator for HER, detailing energy and peak demand savings for both paper-based and web-based participants across the years 2013 and 2014.
[ASK ALL PARTICIPANTS] - H1. Do you recall having signed up on the Efficiency Nova Scotia website to have access to an online report which compares your household's electricity usage to similar homes, illustrates energy usage patterns and...
AI summary The text asks participants if they signed up for an online energy usage report from Efficiency Nova Scotia and how they used it, offering several response options. It is part of a survey or data collection process related to customer engagement with energy efficiency tools.
Program Participation (Series P) - P1. What was the SINGLE most important reason you decided to sign up online for your Home Energy Report? [ACCEPT ONE RESPONSE] [DO NOT READ] - 1. (To save on energy/to save on energy costs) - 2. (Comfort)...
AI summary The document contains survey questions about program participation, focusing on the Home Energy Report and previous involvement in Efficiency Nova Scotia programs. Respondents are asked about their motivations for signing up and any prior participation in energy efficiency initiatives.
Questions on Tips: Buy Energy-efficient Appliances [ASK BF1 TO BF4 SERIES IF PURCHASED ENERGY-EFFICIENT DISHWASHER (B2c=YES) OR ENERGY-EFFICIENT ROOM AIR CONDITIONER (B2e=YES); ASK TWICE IF PURCHASED BOTH; OTHERWISE SKIP TO BW1.] We now ha...
AI summary The text outlines a series of questions aimed at understanding the reasons behind purchasing energy-efficient appliances, such as dishwashers or room air conditioners, within the last 12 months. It focuses on the factors that influenced the purchase decision, including the Energy Star symbol, salesperson recommendations, and EnerGuide labels.
BL3. What do you use to hang your laundry to dry? [ACCEPT MULTIPLE RESPONSES] [READ] 1. 2. 3. 6. Indoor drying racks / hangers Outdoor clothesline Outdoor drying racks, or Something else [SPECIFY] 8. 9. (Don't know) (Refused) BL4. [ASK IF...
AI summary The text contains survey questions about laundry drying practices, including the use of indoor and outdoor drying racks, participation in the Efficiency Nova Scotia's Instant Savings program, and the number of laundry loads per week. The survey also includes instructions for handling responses and navigating to other sections based on answers.
Questions on Tip: Wash Clothes in Cold Water [ASK IF B5c=YES] BV1. light bulbs (CFLs) and faucet aerators, at no charge. In the last 12 months, did you participate in Efficiency Nova Scotia's Residential Direct Install program? As part of...
AI summary The document includes survey questions related to a Home Energy Report's influence on residential energy behavior, specifically the decision to wash clothes in cold water. It also asks about participation in Efficiency Nova Scotia's Residential Direct Install program and the frequency of laundry loads.
BV7. [ASK IF ANSWER TO BL6 OR BV5 ˃ 0] Thinking of the [ANSWER TO BL7 OR BV6] loads of clothes washing your household does in a typical week, approximately how many are washed in cold water, now that you have signed up online for your Home...
AI summary This section of the document includes survey questions related to household energy usage behaviors, focusing on the impact of the Home Energy Report on participants' decisions to turn off their computers at night and the frequency of such actions before and after signing up for the report.
B1. In the last 12 months, did you or someone else in your household purchase one or more energy-efficient appliances for your home? Purchased an Energy Efficient Appliance 2014 Sample Size 340 Yes 38% No 61% Don't know/Refused 1% B2. I am...
AI summary The text presents survey data on the purchase of energy-efficient appliances by households in the last 12 months. It includes percentages of respondents who purchased specific appliances, such as energy-efficient clothes washers, dishwashers, and refrigerators, as well as other appliances like heat pumps and dehumidifiers.
- B5. I am going to read you a list of energy-efficient behaviours that your household may have adopted. For each one, can you please tell me if your household has adopted it in the last 12 months? Taken Steps to Reduce Home Energy Use 201...
AI summary The survey indicates that 80% of respondents have adopted at least one energy-efficient behaviour in the past year, with common practices including turning off lights and washing clothes in cold water. A smaller percentage have taken more advanced steps, such as using a home power monitor or insulating windows.
H1. Do you recall having signed up on the Efficiency Nova Scotia website to have access to an online report which compares your household's electricity usage to similar homes, illustrates energy usage patterns and provides you with energy...
AI summary The question asks if the individual has signed up on the Efficiency Nova Scotia website to access an online report that compares their household's electricity usage to similar homes and provides energy efficiency tips.
P3. Before signing up for the Home Energy Report, had you participated in any of Efficiency Nova Scotia's energy efficiency programs? Participated in Other ENSC programs 2014 Sample Size 250 Yes 56% No 43% Don't know 1% Base: Respondents w...
AI summary The text asks respondents if they participated in Efficiency Nova Scotia's energy efficiency programs before signing up for the Home Energy Report. It also asks which specific programs they participated in, with data showing the most common programs were Instant Savings and energy audits.
BF1. What makes you think the [dishwasher/the room air conditioner] unit(s) you purchased in the last 12 months is/are energy-efficient? 2014 Reason for Believing Appliance was Energy Efficient Dishwasher (%) Air conditioner (#) Sample Siz...
AI summary Respondents were asked about their reasons for believing recently purchased appliances were energy-efficient. Most cited the EnerGuide label or Energy Star symbol, while a smaller percentage mentioned other factors such as salesperson recommendations or word of mouth. A high percentage of respondents indicated that their appliances were Energy Star models.
Likelihood of Insulating Windows Without HER 2014 (#) Sample Size 18 Definitely 13 Probably 4 Probably not 1 Definitely not - Base: Respondents who insulated with heat shrink film BW3. On what type of window did you mostly install heat-shr...
AI summary The text presents survey data from 2014 regarding the likelihood of insulating windows without the Home Energy Report (HER), the types of windows where heat-shrink film was installed, the number of windows insulated, and respondents' intentions to reinstall the film. The data shows high satisfaction with the product.
Importance of HER in Decision to Turn Off Computer at Night 2014 Sample Size Mean Score Average rating: 10= "Extremely influential", 0= "No influence at all" HER influence on decision to turn off computer at night 119 2.5 Base: Respondents...
AI summary A 2014 study assessed the influence of the Home Energy Report (HER) on the decision to turn off computers at night. The survey included 119 respondents, with a mean score of 2.5 on a scale from 0 to 10, where 10 indicated 'Extremely influential' and 0 indicated 'No influence at all.'
- BC4. Now that you have signed up online for your Home Energy Report, how many times a week do you turn off your computer at night? 2014 (%) Times per Week Computer was Turned Off at Night Times per week turned off computer before HER Tim...
AI summary The Home Energy Report (HER) has influenced consumer behavior, with a significant increase in the number of times respondents turned off their computers at night after receiving the report. The average increased from 4.9 to 6.4 times per week.
CS1. How did you first learn about the Home Energy Report? Sources of Awareness 2014 (%) Sample Size 250 Media advertising 26% Through the mail/Bill insert 21% Word of mouth 14% Internet (general) 6% Contacted directly by ENSC 6% ENSC webs...
AI summary The Home Energy Report (HER) was primarily learned about through media advertising (26%) and mail/bill inserts (21%). Satisfaction with the HER was high, with 59% reporting mostly satisfied and 20% completely satisfied. However, 15% were mostly dissatisfied, and 5% completely dissatisfied.
3.1 Participation in Residential Financing As [Figure 2](#page-182-0) illustrates, a total of 66 participants took part in Residential Financing in 2014; with three of them taking part through Solar, 21 through HEA and 42 through Green Hea...
AI summary In 2014, 66 participants engaged in residential financing programs, with 3 through Solar, 21 through Home Energy Assessments, and 42 through Green Heat, as illustrated in Figure 2.
4.2 Participant Perspectives A total of 10 in-depth interviews were conducted with participants who received financing for home improvements under Green Heat (5 interviews), HEA (4 interviews) and Solar (1 interview). The following sub-sec...
AI summary Ten in-depth interviews were conducted with participants who received financing for home improvements under Green Heat, Home Energy Assessment, and Solar programs. The findings from these interviews are analyzed and presented in the following sub-sections.
4.2.1 Awareness and General Perceptions Nearly all participants interviewed (8 of 10) each hired a contractor to complete their home improvements, with all 10 participants having first heard about the financing option from their contractor...
AI summary Most participants in the ENSC energy efficiency program learned about financing options from contractors or suppliers, with many expressing frustration over limited information disclosure. The zero-percent interest rate financing was a major motivator for participation, and few considered alternative financing options due to its rarity. Some participants faced issues due to misinformation from suppliers.
This Appendix presents all recommendations made by the Evaluator throughout this report as well as the sections from which the recommendations originated. Sections Recommendations 2 Increase awareness of the financing option. All 10 partic...
AI summary The appendix highlights a recommendation to increase awareness of the Residential Financing option offered by ENSC. Participants learned about the financing only after deciding on home improvements, suggesting a need for better promotion and information on the financing terms and conditions.
BER Instant Rebates Product Types - › CEE electronic ballasts › LED high bay fixtures - › CEE T8 lamps › LED troffer - › Wall pack induction lamp fixtures › LED strip lighting - › LED decorative walkways › T5 high bay fixtures - › High bay...
AI summary The BER Instant Rebates program offers rebates for various energy-efficient lighting products, aiming to achieve 27.0 GWh of energy savings and 4.8 MW of peak demand savings in 2014. The product types include LED and induction lighting solutions.
Satisfaction Survey results showed that participants were very satisfied with their experience with many aspects of BER, including their interactions and communications with contractors, distributors and consultants, rebate or incentive am...
AI summary Participants in the BER program reported high satisfaction with aspects such as interactions with contractors and rebate amounts, but some found the process cumbersome and lacking in information. Distributors also faced administrative challenges, though they were satisfied with their relationship with ENSC and the program's effectiveness.
Table 2: Overall Comparison of Tracked and Evaluated Savings at the Generator for BER Initial Gross Savings Adjusted Gross Savings Gross Savings Adjusted with Interactive Effects NTGR Net Savings Energy Savings Tracked Savings from ENSC 32...
AI summary The evaluation of the Business Energy Rebates (BER) program in 2014 showed slightly higher net energy savings compared to tracked savings, but lower peak demand savings. Adjustments in savings calculations for HVAC and lighting increased gross energy savings, while a lower NTGR and lack of diversity factors in tracking reduced net and peak demand savings, respectively.
BER Instant Rebates Product Types - › CEE T8 lamps › LED troffer - › Wall pack induction lamp fixtures › LED strip lighting - › LED decorative walkways › T5 high bay fixtures - › CEE electronic ballasts › LED high bay fixtures - › High bay...
AI summary The BER Instant Rebates Product Types include various lighting products such as LED troffers, LED strip lighting, and T5 high bay fixtures. These products are now submitted under BER, which aimed for 27.0 GWh of electricity savings and 4.8 MW of peak demand savings in 2014. Energy savings are accounted for under the BNI Efficient Products Rebates.
Annual Participant Survey For the annual survey, the interviews were conducted in October and November 2014 using computer-assisted telephone interviewing (CATI) technology. The average length of the survey was eight minutes. The annual su...
AI summary The annual participant survey was conducted in October and November 2014 using CATI technology. It aimed to collect feedback on the BER Mail-in program, covering aspects like participation, awareness, motivations, satisfaction, and recommendations for improvement. Results are detailed in appendices.
3.1 Participation in BER In 2014, BER had a total of 296 participants, compared to 270 in 2013, 175 in 2012 and 106 in 2011. These 296 participants included 98 participants in the promotional rebate on LED tubes for fluorescent fixtures, w...
AI summary BER participation increased in 2014 due to a promotional rebate on LED tubes, but regular participation declined slightly, partly because some ECM projects were removed from the tracking system due to quality issues.
Table 5: Implementation Status of Recommendations in 2012 and 2013 Executive Summaries Recommendation Status 2012 Recommendations 2012 BER-R1 Analyze product offering to reduce duplicate rebates and program overlapping in the market Implem...
AI summary This table outlines the implementation status of recommendations made in 2012 and 2013 executive summaries, focusing on energy efficiency programs. Most recommendations have been implemented, though some remain partially implemented or are yet to be addressed.
BER Mail-in The review of the BER Mail-in tracking system included both the Excel sheet containing data exported from the DSMDS and the documentation stored in the DSMDS. In 2014, ENSC used only the DSMDS to manage the application process...
AI summary The BER Mail-in tracking system was reviewed, highlighting improvements in the Excel report's structure, including consolidated project information and automated savings calculations. The DSMDS was used in 2014, with savings equations stored in the Screening Tool and copied into the Project Summary tab. The Evaluator recommends using formulas to link total savings to individual measure savings to prevent errors.
e_1.jpeg) operation) into separate columns. At present time, there is no way to validate that savings were calculated correctly other than verifying each entry manually. The Equations tab was added to the tracking sheet this year. For each...
AI summary The tracking sheet for energy efficiency programs has improved, with the addition of an Equations tab that provides energy savings equations for lighting products. However, the Evaluator recommends including information on the baseline technology for lighting products to improve clarity and ease of use.
4.2.1 Previous Program Participation Before participating in BER, nearly four in 10 participants had previously taken part in an ENSC program. These programs included Custom Retrofit, BES and BER.
AI summary Before participating in the Business Energy Rebates (BER) program, nearly 40% of participants had previously participated in an Efficiency Nova Scotia Corporation (ENSC) program, including Custom Retrofit, Business Energy Solutions (BES), and BER.
Table 7: Previous Program Participation Other Program Participation 2012 (%) 2014 (%) Sample Size 56 27 Yes 30% 37% No 66% 63% Don't know 4% - Program Participation 2012 (#) 2014 (#) Sample Size 17 10 Custom Retrofit 5 2 Small Business Ene...
AI summary Table 7 provides data on previous program participation, showing a slight increase in participation from 2012 to 2014, with 30% participating in 2012 and 37% in 2014. Specific programs such as Custom Retrofit, Small Business Energy Solutions, and Smart Lighting Choices are listed with participation numbers.
Table 8: Reasons for Participating 2012 2014 Motivations Most Important Motivation Second Most Important Motivation Most Important Motivation Second Most Important Motivation Sample Size 56 56 27 27 Save on energy costs/bills 55% 32% 59% 2...
AI summary Table 8 presents data on participants' motivations for joining energy efficiency programs in 2012 and 2014. The primary motivation was saving on energy costs, with a significant decline in the percentage of participants citing this reason over time. Other motivations included taking advantage of program incentives, updating equipment, and environmental concerns.
5 IMPACT EVALUATION FOR BER MAIL-IN The objective of the 2014 impact evaluation for BER Mail-in was to determine the gross and net energy savings. Both electrical energy and peak demand savings were estimated by analyzing the following par...
AI summary The 2014 impact evaluation for BER Mail-in aimed to assess gross and net energy savings by analyzing parameters such as installation rates, equipment features, and load factors. Interactive effects were considered for lighting measures but not for others. Adjustments and diversity factors were established based on documentation and on-site visits.
5.1.1 HVAC Measures A total of 15 on-site visits were conducted for the HVAC measure category this year, but only 13 projects were included in the final analysis because two incomplete projects were removed from the sample. All the complet...
AI summary The document discusses the evaluation of HVAC measures, specifically heat pump installations, based on 13 completed projects out of 15 on-site visits. Adjustments were made to energy and demand savings based on factors like full-load hours and heating capacity, referencing AHRI Standard 210/240.
5.1.2 Commercial Lighting Measures A total of 25 on-site visits were conducted for the lighting measures category; however, as mentioned above, three projects were eliminated from the data analysis because they were incomplete at the time...
AI summary The document discusses the evaluation of commercial lighting measures, including on-site visits, adjustments to tracked savings, and the impact of ballast factors on energy savings calculations. Over 80% of projects involved LED measures, and the evaluation highlights the importance of considering ballast factors in calculating energy savings.
Where: Wlamp represents the nominal wattage of the lamp. It should be noted that for some LED products, the specification sheet presents the wattage of the lamp based on a given ballast factor, in which case the ballast factor is already i...
AI summary The document discusses adjustments made to lighting energy and demand savings calculations in 22 projects. Adjustments were made due to discrepancies in wattage specifications, operation hours, and seasonal variations. An overall adjustment ratio of 1.035 was applied to energy savings, and 0.777 to demand savings. These adjustments were also applied to additional lighting projects in a separate tracking report.
5.1.3 Commercial Refrigeration Measures Three commercial refrigeration projects were sampled as part of the 2014 evaluation. The tracked energy savings were underestimated for all the three projects, and the tracked demand savings were und...
AI summary Three commercial refrigeration projects were evaluated, revealing underestimated energy and demand savings. Discrepancies in calculations and incorrect algorithm application led to revised savings estimates, with energy savings increasing by 31.2% and demand savings by 27.3%.
5.1.4 Motor and VSD Measures Originally, the motor and VSD measure category was evaluated by conducting twelve on-site visits. As previously mentioned, seven projects were eliminated from the sampled visits because the measure installed wa...
AI summary The evaluation of motor and VSD measures involved on-site visits and adjustments due to incorrect installations by a single contractor. 22 ECM projects were removed from tracking due to recurring issues, and the Evaluator recommends a comprehensive review and potential site visits to validate savings claims.
5.1.7 Commercial Kitchen Measures Commercial kitchen measures were evaluated by conducting five on-site visits. Only one project validated had its tracked savings values matching the revised values. The most prevalent problem was errors in...
AI summary An evaluation of commercial kitchen measures found issues with tracked savings calculations, including incorrect equations and missing elements. Adjustments were made to the savings of visited projects, increasing energy and demand savings by 15.4% and 45.6%, respectively.
5.1.8 Commercial Laundry Measures One commercial laundry project was validated in 2014. No adjustments were needed, as the data was complete and accurate. The tracked energy savings were 965 kWh, and the tracked demand savings were 3.46 kW.
AI summary A commercial laundry project validated in 2014 achieved tracked energy savings of 965 kWh and demand savings of 3.46 kW, with no adjustments needed due to complete and accurate data.
5.1.11 Diversity Factor Similar to previous years' evaluations, the electricity-demand peak period in Nova Scotia is between 7 a.m. - 12 p.m., and 4 p.m. - 11 p.m. in December, January, and February during weekdays.7 The period of 5 p.m. -...
AI summary This section discusses the diversity factor for various energy efficiency measures in Nova Scotia, noting that HVAC systems have a high diversity factor due to heat pump usage, while lighting and compressed air systems have lower factors due to operational timing and project sampling.
Table 12: Diversity Factors for BER Mail-in Category of Measure Diversity Factor HVAC 98% Commercial Lighting 84% Commercial Refrigeration 84% Motors and VSDs 72% Compressed Air 39% Agricultural 80% Commercial Kitchen 96% Water Heating 100...
AI summary Table 12 outlines diversity factors for various energy efficiency measures under the Business Energy Rebates (BER) program, indicating the percentage of diversity each measure contributes to the overall program.
5.1.12 Revised Gross Savings The savings achieved by every category of BER Mail-in measure are presented in Table 13. Both the energy and demand savings were revised by incorporating the adjustments discussed in the previous sections. Usin...
AI summary This section presents revised gross energy and demand savings for the BER Mail-in program, incorporating adjustments from prior sections. The savings are calculated using a line loss factor of 1.068 and a diversity factor, resulting in 12.902 GWh of energy savings and 1.988 MW of peak demand savings at the meter, with higher values at the generator.
Table 13: Evaluation Results – Revised Gross Savings – BER Mail-in Category of Measure HVAC Lighting Refrige ration Motors and VSDs Compressed Air Agricultural Tracking System Savings Tracked Energy Savings (GWh) 2.837 4.588 0.097 1.269 0....
AI summary Table 13 presents evaluation results for revised gross savings from the BER Mail-in program, detailing energy and demand savings across various categories of measures such as HVAC, lighting, and compressed air. It includes metrics like tracked energy savings, adjustment ratios, and line loss factors for both energy and peak demand savings.
(Continued) Category of Measure Kitchen Water Heating Laundry Solar LED Promotion Total for All Categories Tracking System Savings Tracking System Savings Tracked Energy Savings (GWh) 0.309 0.057 0.003 0.004 2.671 12.376 Tracked Demand Sav...
AI summary The text presents a table detailing energy and demand savings across various categories, including kitchen, water heating, laundry, solar, and LED promotion. It includes metrics such as tracked energy savings, adjustment ratios, and line loss factors. The section 'Net-to-Gross Ratio' is mentioned, indicating a discussion on efficiency metrics.
Table 14: Evaluation Results – Revised Net Savings – BER Mail-in Category of Measure HVAC Lighting Refrige ration Motors and VSDs Compressed Air Agricultural Energy Savings Total Gross Energy Savings – at Meter (GWh) 3.013 4.786 0.128 1.26...
AI summary Table 14 presents evaluation results for the Revised Net Savings from the BER Mail-in program, detailing energy and peak demand savings across various categories of measures, including HVAC, Lighting, and Compressed Air, with calculations involving Net-to-Gross Ratio and Line Loss Factor.
Table 15: Comparison of Tracked and Evaluated Savings at the Generator – BER Mail-in Initial Gross Savings Adjusted Gross Savings NTGR Net Savings Energy Savings Tracked Savings from ENSC 13.218 GWh 13.218 GWh 0.82 10.839 GWh Evaluation Re...
AI summary Table 15 compares tracked and evaluated savings from the Business Energy Rebates (BER) program. Evaluated gross energy savings exceeded tracked savings in 2014, primarily due to adjustments in HVAC and lighting categories. Although the Net-to-Gross Ratio (NTGR) decreased, net energy savings were still higher than tracked values by one percent.
6 IMPACT EVALUATION FOR BER INSTANT REBATES The objective of the 2014 impact evaluation for BER Instant Rebates was to determine the gross and net energy savings. Both electrical energy and demand savings were estimated by analyzing the fo...
AI summary The 2014 impact evaluation for BER Instant Rebates aimed to assess gross and net energy savings, considering factors such as savings calculation methodology, diversity factor, interactive effects, and free-ridership for both electrical energy and demand savings.
6.1 Gross Savings This section presents the tracked and revised savings for each product category rebated under BER Instant Rebates. This year, the Evaluator reviewed the consistency of hours of operation and equations used for all the pro...
AI summary This section discusses the evaluation of gross savings for BER Instant Rebates, noting revisions to baseline wattage for T8 lamps and CEE-listed ballasts based on Canadian regulations. The Evaluator recommends improving energy savings equations and monitoring market changes due to upcoming regulatory amendments.
Tracked Savings In the 2013 impact evaluation, the Evaluator considered the displaced wattages used for HP-T8 and RW-T8 lamps to be valid. The baseline lamp is still a 34-watt T12 lamp, with the more efficient lamps having wattages of 25,...
AI summary The 2013 impact evaluation validated the displaced wattages for HP-T8 and RW-T8 lamps, with baseline lamps being 34-watt T12 lamps. More efficient lamps had wattages of 25, 28, or 32 watts, and the hours of operation were validated in 2012 through a metering study under the BES program.
Revised Savings The types of T8 products sold through BER Instant Rebates are identical to last year's products. Therefore, the Evaluator considers the displaced wattages to be valid for this year. As no new metering activity was conducted...
AI summary The document discusses the unchanged product types and savings calculations for T8 products under the BER Instant Rebates program. It notes the need to monitor market changes, as more efficient products like LED T8 lamps may shift the baseline. This trend is already evident in on-site visits for BER and BES programs.
Table 17: Unitary Savings Values for High-performance Ballasts Type of Ballast Demand Savings (W) Hours of Operation (hrs/year) Energy Savings (kWh/year) 1-lamp ballast 13.46 3,400 45.76 2-lamp ballast 13.46 3,400 45.76 3-lamp ballast 24.3...
AI summary Table 17 presents unitary savings values for high-performance ballasts, including demand savings, hours of operation, and energy savings per year for different types of ballasts. The table includes 1-lamp, 2-lamp, 3-lamp, and 4-lamp ballasts with corresponding energy savings values.
Table 18: Revised Displaced Wattages for Each Ballast Type New Ballast and Lamp Systems Baseline Wattage New Wattage Lamp ΔW Ballast ΔW Proportion of T8 Lamps Average Ballast ΔW 1-lamp ballast with HP-T8-32 W lamp 43 27 2 14 61.4% 1-lamp b...
AI summary Table 18 presents revised displaced wattages for various ballast and lamp systems. The data includes baseline and new wattage values, differences in lamp and ballast wattages, and the proportion of T8 lamps. The table is used to calculate revised unitary savings values for 2014, using the same annual hours of operation as in 2013.
Table 19: Revised Unitary Savings Values for High-performance Ballasts Type of Ballast Demand Savings (W) Hours of Operation (hrs/year) Energy Savings (kWh/year) 1-lamp ballast 13.61 3,400 46.27 2-lamp ballast 13.61 3,400 46.27 3-lamp ball...
AI summary Table 19 presents revised unitary savings values for high-performance ballasts, detailing demand savings, hours of operation, and energy savings for different types of ballasts.
6.1.8 Electronically Commutated Motors ENSC discontinued offering this product in 2014, but some motors purchased in 2013 were returned to the distributors in 2014. As a result, last year, the unitary savings of 954 kWh and 109 W were appl...
AI summary ENSC discontinued offering Electronically Commutated Motors in 2014, but some motors purchased in 2013 were returned in 2014. This led to unitary savings of 954 kWh and 109 W being applied to account for negative savings to BER Instant Rebates in 2014.
6.1.9 Diversity Factor As no on-site visits were conducted for BER Instant Rebates, no specific diversity factor could be established. Hence, the diversity factor of 83 percent used by the BER Mail-In approach to lighting products was also...
AI summary The diversity factor of 83 percent, used by the BER Mail-In approach for lighting products, was applied to BER Instant Rebates due to the similarity of products sold by both initiatives and the lack of on-site visits for BER Instant Rebates.
Table 20: Evaluation Results – Gross Energy and Peak Demand Savings for Instant Rebates Products with Unitary Savings Values Ca Pr du t te o c g or y H P- T 8- 3 2 W La m p s R W -T 8- 2 8 W La m p s R W -T 8- 2 5 W La m p s 1- La m p H P...
AI summary Table 20 presents evaluation results for gross energy and peak demand savings from instant rebate products with unitary savings values, including data on various lamp and ballast products and their associated energy savings.
Table 21: Evaluation Results – Gross Energy and Peak Demand Savings for All Other Instant Rebates Products Pr du Ca t te o c g or y T 5 d T 8 an H ig h Ba s y D Do L E l ig h ts n w O t he r In do D La L E or m p s O t do u or L D W E l lp...
AI summary Table 21 presents evaluation results for gross energy and peak demand savings from all other instant rebates products. It includes various categories and totals, such as the number of units in the program, with figures ranging from 3,087 to 23,115,7.
Table 22: Interactive Effects Factor for Indoor Lighting Products Parameters Proportion of Buildings Interactive Effects10 Electric heating with air conditioning 10% -43.4% Electric heating without air conditioning 3% -49.0% Heating and co...
AI summary Table 22 provides an interactive effects factor for indoor lighting products, showing varying percentages based on heating and cooling configurations. No interactive effects factor was applied to outdoor lighting products, and a previous factor was applied to LED strip lighting for refrigeration applications in 2013. This year's calculation does not account for interactive effects.
Table 25: Evaluation Results – Net Energy and Peak Demand Savings for Instant Rebates Products with Unitary Savings Values Ca f Pr du te t g or o o c y H P- T 8- 3 2 W la m p s R W -T 8- 2 8 W la m p s R W -T 8- 2 W 5 la m p s 1- La m p H...
AI summary Table 25 presents the evaluation results of net energy and peak demand savings for instant rebate products with unitary savings values, including various lamp and ballast products, lighting occupancy sensors, and motors. The table provides data on gross energy savings and efficiency factors for each product category.
Table 26: Evaluation Results – Net Energy and Peak Demand Savings for Other Instant Rebates Products Ca f te Pr du t g or y o o c T 5 d T 8 an H ig h Ba y s D Do L E l ig h ts w n O t he r In do D La L E or m p s O t do u or L D W E l lp k...
AI summary Table 26 presents evaluation results for net energy and peak demand savings from Other Instant Rebates Products. It includes metrics such as total gross energy savings, high bay savings, and other categories, with numerical values provided for each category.
7 OVERALL BER RESULTS This section summarizes the overall results of the impact evaluation of BER. With combined net savings generated from both the mail-in rebate and the instant rebate approaches, the total energy and peak demand savings...
AI summary The impact evaluation of the BER program shows that combined net savings from both mail-in and instant rebate approaches resulted in 24.610 GWh of energy savings and 4.880 MW of peak demand savings.
Sections Recommendations 15 The Evaluator recommends again this year adjusting the baseline values for both lamps and ballasts, in a manner consistent with other jurisdictions' baseline values. Also, a ballast factor of the new fixtures sh...
AI summary The Evaluator recommends adjusting baseline values for lamps and ballasts to align with other jurisdictions and using on-site evaluation results for LED downlights. Controlled wattage values for occupancy sensors are also recommended for adjustment based on sensor type and values from Vermont's technical reference manual.
APPENDIX II INTERVIEW GUIDE WITH DISTRIBUTORS Hello, may I please speak with? [INTRODUCTION] Hello, my name is, from Corporate Research Associates Inc., a marketing survey research firm. I am calling on behalf of Efficiency Nova Scotia Cor...
AI summary This text introduces an interview guide used by Efficiency Nova Scotia Corporation to gather opinions on the impact of the Business Energy Rebates Program from distributors.
ASK IF T5 AND T8 HIGH BAY FIXTURES WERE REBATED THROUGH THE PROGRAM amounted to products. I have a few questions about your sales of T5 and T8 high bay fixtures that are promoted by the Business Energy Rebates Program. Our records indicate...
AI summary The text asks whether T5 and T8 high bay fixtures were rebated through the Business Energy Rebates Program, inquiring about sales trends, the impact of the program's incentives, and potential differences in sales with or without the program.
ASK IF LED DOWNLIGHTS WERE REBATED THROUGH THE PROGRAM I have a few questions about your sales of LED downlights that are promoted by the Business Energy Rebates Program. LED downlights include LED screw-in lamps, LED pin-based lamps, LED...
AI summary The text asks whether LED downlights were rebated through the Business Energy Rebates Program, inquiring about sales trends, the impact of the program on sales, and the percentage of sales attributed to residential users. It also explores the potential effect of removing the incentive on sales.
S4a. If "Yes," please explain the nature of the improvement(s): Those are all the questions I have for you today. Would you like to add anything else regarding the program or talk about any other topic that was not covered during the inter...
AI summary The text includes questions regarding program improvements and mentions ongoing research on new codes and standards in Nova Scotia, as well as outreach to contractors for assessing the influence of energy efficiency programs on client decisions.
[INTRODUCTION] Hello, I am with CRA (Corporate Research Associates), and we are performing an evaluation of energy efficiency services provided by Efficiency Nova Scotia Corporation. Our records indicate that you or your firm recently part...
AI summary CRA is conducting an evaluation of Efficiency Nova Scotia Corporation's Business Energy Rebates Program and is reaching out to participants for feedback. The survey aims to help improve the program and will take about fifteen minutes to complete.
Verification and Recall (V Series) - V1. Our records indicate that your company or organization would have received a mail-in rebate for an energy efficiency measure that was installed as part of Efficiency Nova Scotia's Business Energy Re...
AI summary This section of the document outlines a verification and recall process for determining if a company or organization received a mail-in rebate for an energy efficiency measure under Efficiency Nova Scotia's Business Energy Rebates Program. It includes a series of questions to identify the most knowledgeable individual and whether they participated in the program.
Program Awareness and Participation (P Series) - P1. Did your company or organization participate in any other Nova Scotia Power or Efficiency Nova Scotia programs before the Business Energy Rebates Program? - 1. Yes - 2. No (Go to P4) - 9...
AI summary The document outlines a series of questions related to program awareness and participation, specifically focusing on the Business Energy Rebates Program. It asks whether respondents participated in prior programs, how they learned about the Business Energy Rebates Program, and what motivated their participation.
Satisfaction [S series] - S1. On a scale of 1 to 5, where 1='not at all satisfied' and 5='very satisfied', how was your company or organization's experience with each OF THE FOLLOWING aspects of the Business Energy Rebates Program? If your...
AI summary The text outlines a survey assessing satisfaction with the Business Energy Rebates Program, focusing on aspects such as application processes, eligibility confirmation, rebate amounts, and overall program experience. It includes rating scales and open-ended questions for feedback on challenges and recommendations.
98. Don't know 99. Refused B8. 1. 2. Did you encounter any problems with the [MEASURE CATEGORY] measure you implemented as part of the Business Energy Rebates program? Yes No (SKIP TO B6) 98. 99. (Don't know) (SKIP TO B6) (Refused) (SKIP T...
AI summary The text presents a survey form related to the Business Energy Rebates program, asking participants about problems encountered, resolution of those problems, and suggestions for program improvement. It includes options for responses and skips to other sections based on answers.
APPENDIX IV ANNUAL SURVEY RESULTS The BER Mail-in participant survey results are presented in the following tables. - P1. Did your company or organization participate in any other Nova Scotia Power or Efficiency Nova Scotia programs before...
AI summary The BER Mail-in participant survey results are presented in tables, including a question about prior participation in Nova Scotia Power or Efficiency Nova Scotia programs.
S10. Thinking of when you completed and sent your post-install mail-in rebate application to ENSC, how long, in weeks, was it before you received your mail-in rebate? Length of Time to Receive Rebate 2014 (#) Sample Size 17 3-4 weeks 7 5-8...
AI summary The text presents survey data on the time taken to receive mail-in rebates from ENSC, the likelihood of future energy-efficient product purchases, and barriers faced in implementing energy-efficient measures. It includes statistics from 2012 and 2014, with sample sizes and percentages provided.
[INTRODUCTION] Hello, I am with CRA (Corporate Research Associates), and we are performing an evaluation of energy efficiency services provided by Efficiency Nova Scotia Corporation. Our records indicate that you or your firm recently part...
AI summary CRA is conducting an evaluation of Efficiency Nova Scotia Corporation's Business Energy Rebates Program and is seeking participation from individuals or firms who have participated in the program to improve it.
Satisfaction (S Series) - S1. How did your company first learn of the programs offered by Efficiency Nova Scotia? [DO NOT PROVIDE RESPONSE CATEGORIES]. [CODE AS MANY AS APPLICABLE] . - 1. Media advertising - 2. Someone at Efficiency Nova S...
AI summary The text presents a series of survey questions related to customer satisfaction with Efficiency Nova Scotia's programs. It asks about how businesses learned about the programs, their level of direct contact with Efficiency Nova Scotia, and their satisfaction with various factors such as technical expertise, responsiveness, and program value.
- j. The ability to provide estimates of the savings or return on investment associated with the program. Response 98 Don't Know 99 Refused S5. Now, using the same 10 point scale, how satisfied are you with Efficiency Nova Scotia's overall...
AI summary The text discusses the ability to provide estimates of savings or return on investment associated with a program, followed by survey questions about satisfaction with Efficiency Nova Scotia's performance and interactions with contact centre representatives.
99. (Refused) FR1. Did your company or organization decide to implement the energy-efficient [MEASURE CATEGORY] measure before participating in the Business Energy Rebates Program? 1. Yes 2. No 98. (Don't know) - FR1a. IF FR1= YES, THEN AS...
AI summary The document includes a question regarding whether a company or organization decided to implement an energy-efficient measure before participating in the Business Energy Rebates Program, with follow-up clarification if the answer is 'Yes'.
FR2a installed exactly the same energy-efficient [MEASURE CATEGORY] equipment that you installed through the Program? Response 98 Don't Know 99 Refused FR2b installed standard [MEASURE CATEGORY] equipment? [MEASURE CATEGORY] equipment inst...
AI summary This section of the document contains survey questions related to the installation of energy-efficient equipment through a program, including responses such as 'Don't Know' and 'Refused'. It also includes conditional questions based on the number of installations.
S1. How did your company first learn of the programs offered by Efficiency Nova Scotia? Sources of Awareness 2012 (%) 2013 (%) 2014 (%) Sample Size 30 80 68 Through a third-party contractor 17% 29% 41% ENSC website 7% 16% 15% Respondent wa...
AI summary The text provides data on how companies first learned about Efficiency Nova Scotia's programs between 2012 and 2014, highlighting the increasing role of third-party contractors and declining influence of media advertising and word of mouth over time.
S28. Based on your company's experience working with Efficiency Nova Scotia and its third-party contractors, would you definitely, probably, probably not, or definitely not participate in other programs offered by Efficiency Nova Scotia?
AI summary The question asks about the likelihood of participation in Efficiency Nova Scotia programs based on the company's experience with third-party contractors.
Would Participate in Other ENSC Programs 2012 (%) 2013 (%) 2014 (%) Sample Size 30 78 68 Definitely 77% 72% 81% Probably 23% 23% 19% Probably not - 3% - Definitely not - 3% - Don't know/refused have been removed from calculations Source: 2...
AI summary The text presents survey data from 2012 to 2014 on participation in ENSC programs and factors influencing the implementation of energy-efficient measures through the Business Energy Rebates Program. It highlights high participation rates and the importance of ENSC rebates as a key factor in decision-making.
On-Site Visit Data Collection Form 1. General Information Date of visit: Project Name: Project Tracking sheet #: Company Name: Contact Name: Address: Telephone: Retail: Manufacturing/ Industrial: Grocery/ Supermarket: Type of facility: Col...
AI summary The document presents an On-Site Visit Data Collection Form used to gather information about energy usage and facility details. It includes sections for general information, project tracking, company details, and facility type, among other data points.
Cooling Systems: Please fill the table below for each cooling system at the site Cooling system 1 Cooling system 2 % of cooling Type of system SEER or COP 3. Facility Operation Hours and Lighting Usage
AI summary The document contains a table for recording information about cooling systems at a facility, including their type, efficiency ratings, and percentage of cooling. It also includes a section about facility operation hours and lighting usage, though no details are provided.
4. Measures information Lighting : Collect the information in the table below if lighting measures were installed. Use on-site observation and contact declaration. Use additional sheets if required. Econoler will then compare the informati...
AI summary This section provides instructions for collecting lighting measures information, including on-site observation and contact declaration, and references a tracking sheet for comparison by Econoler.
New equipment installed Baseline equipment Qua intity Wat ttage Quantity ntity Wat tage Additional Туре Tracking Sheet On-Site validation Tracking Sheet On-Site validation Notes: Туре Tracking Sheet On-Site validation Tracking Sheet On-Sit...
AI summary The text presents a table detailing the installation of new lighting equipment and baseline equipment, including various types of LED and other lighting fixtures. It includes information on wattage, quantity, tracking sheets, on-site validation, and additional notes relevant to each type of lighting.
Data (Operating Temp, CFM, Size, Control Info) Date of installation: Motors Total number of motors installed: Motor 1 Motor 2 Motor 3 Manufacturer: Model number: Motor Size [hp]: NEMA Nominal Efficiency (nameplate): Load Factor: Approx. pr...
AI summary The document contains a table for collecting data on motor and VSD installations, including details such as manufacturer, model number, efficiency, load factor, and operational parameters. It is used to assess energy efficiency and compliance with programs like the Business Energy Rebates.
手 ECC NOL ΞR Existing HVAC 1 Existing HVAC 2 Existing HVAC 3 New HVAC 1 New HVAC 2 New HVAC 3 AC & Air-Source Heat Pumps: Location on site: Manufacturer: Model number: Number of units Space heating source (electricity, fuel, etc.): Specify...
AI summary The text presents a table for recording details about existing and new HVAC systems, including information on manufacturers, models, efficiency ratings, usage hours, and installation status. It is part of a regulatory proceeding in Nova Scotia.
Date of installation: Equipment installed Strip-curtains – Length installed [ft]: Is the equipment still used? If not, why and since when? Medium or High Temp Cases? Cooler night covers – Length installed [ft]): Is the equipment still used...
AI summary The document contains a table requesting information about the installation and current use of various energy-efficient equipment in refrigeration systems, including strip-curtains, cooler night covers, open-to-closed cooler conversions, zero-energy doors, and door/frame heater controls. It asks about the length installed, whether the equipment is still in use, reasons for discontinuation, and hours of use per year.
Compressed Air: Collect the information in the table below if compressed air measures were installed. Use on-site observation and contact declaration. Use additional sheets if required. The information collected will then be compared with...
AI summary The text provides instructions for collecting information related to compressed air measures, including manufacturer and model numbers, technical data, and on-site observations. This information will be compared with data from a tracking sheet by Econoler.
CFM, Size, Control Info) Date of installation: Compressed Air Products Installed Cycling refrigerated air dryer – Number installed: Verify <300 cfm capacity Is the equipment still used? If not, why and since when? Compressor operation [hr/...
AI summary The document contains a table with questions regarding the installation, usage, and operational details of various compressed air products, including cycling refrigerated air dryers, VSD screw compressors, air-entraining air nozzles, and no-loss drains. It seeks information on equipment status, capacity, usage hours, and system pressure.
Date of installation: Water heating source: Commercial Washing Machines Installed ENERGY STAR commercial washing machine – Number installed: Manufacturer: Model number: Size [cubic feet]: Is the equipment used for commercial purpose? Is th...
AI summary The document contains a table for recording details about the installation and usage of commercial washing machines, including ENERGY STAR and CEE Tier 2 rated equipment. It includes fields for equipment type, manufacturer, model, size, usage, and validation of energy efficiency ratings.
FR2a. If your company had not participated in BER, what is the likelihood that you would have installed exactly the same energy-efficient equipment that you installed through the program? (Scale 0 to 10) IF Pre-FR3 = Yes: FR2a = (Answer x...
AI summary The text outlines a set of questions and formulas used to calculate a PA1 score related to the Business Energy Rebates (BER) program. It assesses the likelihood that a company would have installed energy-efficient equipment without the program and how the score is calculated based on responses.
APPENDIX IX CALCULATION EXAMPLE This Appendix provides an example calculation to describe the adjustment process performed for all savings associated with the measure categories of BER MI. As the HVAC measure category was the largest sourc...
AI summary This appendix provides a calculation example for adjusting energy savings from the Business Energy Rebates (BER) MI program, focusing on HVAC measures, particularly air source heat pumps. It outlines algorithms, tracked savings, and revised savings results based on on-site validation.
Energy and Demand Savings Algorithms The 2014 CIRx Screening Tool 1.3 HVAC tab contains the energy and demand savings algorithms for all measures. The equations below describe those used for ASHPs with a capacity of less than 65,000 Btu/hr...
AI summary This section describes the energy and demand savings algorithms used in the 2014 CIRx Screening Tool 1.3 for air-source heat pumps (ASHPs) with a capacity below 65,000 Btu/hr. The formulas calculate annual energy and demand savings based on performance factors and full load hours.
The table below presents a summary of the calculation parameters, and their respective sources, used for a specific ASHP project. Parameter Value Source Rated heat pump capacity – heating (kBtu/h) 26.4 Air-Conditioning, Heating, and Refrig...
AI summary The table outlines the calculation parameters for a specific Air-Source Heat Pump (ASHP) project, including values such as rated heat pump capacity, HSPFbase, HSPFee, FLHw, and others, with their respective sources such as the CIRx Screening Tool and equipment specification sheets.
The evaluation revealed that Custom Retrofit and its two sub-components generated 26.988 GWh in net energy savings at the generator in 2014. As for electricity demand reduction, the program component achieved 1.599 MW in net peak demand sa...
AI summary The evaluation found that the Custom Retrofit program and its sub-components achieved significant energy savings in 2014, with 26.988 GWh in net energy savings and 1.599 MW in net peak demand savings at the generator. No savings were reported for EBC and EMIS.
Table 2: 2014 Net Savings at the Generator of Custom Retrofit, EMIS and EBC Initial Gross Savings Adjusted Gross Savings NTGR Net Savings Energy Savings Tracked Savings from ENSC 29.353 GWh 29.353 GWh 0.93 27.314 GWh Evaluation Results 29....
AI summary Table 2 presents net savings data from 2014 for energy and peak demand savings generated by Custom Retrofit, EMIS, and EBC initiatives. The data includes initial and adjusted gross savings, the net-to-gross ratio (NTGR), and net savings for both energy and peak demand categories.
2.2.4 Project File Review In the fall of 2014, the Econoler team evaluated five projects, which were supported by either the EBC or the EMIS components of Custom Retrofit. Conducted on the basis of a technical review of these two sub-compo...
AI summary In 2014, the Econoler team evaluated five projects supported by EBC or EMIS components of Custom Retrofit. The evaluation aimed to recommend improvements in the methodology for documenting and calculating savings, as well as ENSC's approach to supporting and verifying these projects.
Table 4: Implementation Status of Recommendations in 2012 and 2013 Executive Summaries Recommendation Status 2012 Recommendation 2012 Custom-R1 Consider diverting or assigning a proportion of the simple lighting retrofit projects to other...
AI summary Table 4 outlines the implementation status of recommendations from 2012 and 2013 executive summaries, focusing on improvements in energy efficiency programs, such as retrofit projects, diversity factor calculations, and the use of measurement and verification (M&V) procedures. Many recommendations have been fully or partially implemented, with ongoing efforts in some areas.
3.3 Program Documentation and Design Custom Retrofit is by far the most complex component of ENSC's program portfolio. This type of program is usually capital and labour-intensive since it involves supporting and tracking custom projects w...
AI summary Custom Retrofit is the most complex component of ENSC's program portfolio, requiring significant capital and labor due to its non-standard nature. A 2012 process evaluation led to changes in the program, and the 2014 evaluation focused on whether these changes aligned with international best practices. The program aims to support projects that do not fit into standardized programs, offering tailored technical, financial, and management support.
Measures by Category Almost identical to the Measures by Project tab, the information documented in the Measures by Category tab focuses on the types of projects implemented. This structure allowed the Evaluator to gain a better understand...
AI summary The 'Measures by Category' tab documents the types of energy efficiency projects implemented, providing insight into the kinds of measures that achieved savings for each Custom Retrofit project, similar to the 'Measures by Project' tab.
3.4.2 Online DSMDS In addition to the tracking report provided, the Evaluator reviewed the contents and structure of ENSC's DSMDS. Since all current Custom Retrofit projects are now being tracked online through this tool, the Evaluator fel...
AI summary The Evaluator reviewed ENSC's Demand-Side Management Data System (DSMDS), focusing on the Project Summary and Measures and Documents tabs, to assess accuracy and identify areas for improvement, as all current Custom Retrofit projects are now tracked online through this tool.
Measures The Measures tab in the DSMDS shows a table summarizing individual projects' energy savings and implementation costs. The energy savings section provides necessary information required to assess and verify the tracked savings achi...
AI summary The Measures tab in the DSMDS provides detailed information on energy savings, implementation costs, and other factors such as power and diversity factors. ENSC has added these factors based on recommendations from the Evaluator since 2013, showing a commitment to improving data collection and process efficiency.
Milestones The Milestones tab provides the amount of savings claimed at each step of the project. This tab is particularly useful for projects whose implementation period extends over more than one year. This is also where any subsequent s...
AI summary The Milestones tab tracks energy savings at various project stages, including meter and generator levels. It is especially useful for long-term projects and includes adjustments based on M&V. The Evaluator suggests adding clarity by specifying whether peak demand savings are at-the-meter or at-the-generator level.
Documents The Documents tab contains the most detailed information about the 2014 Custom Retrofit projects; it typically includes scoping studies, feasibility studies, the project development agreement (PDA), M&V documentation and other pr...
AI summary The 2014 Custom Retrofit tracking system is considered adequate with signs of improvement, but recommendations include adding Nova Scotia Power rate codes, explaining diversity factors, and identifying M&V adjustments in the DSMDS report to enhance evaluation accuracy and data clarity.
Table 5: Sources of Awareness Sources of Awareness 2012 (%) 2013 (%) 2014 (#) Sample Size 27 29 11 Internet/ENSC website 7% 14% 4 Energy manager - - 2 ENSC staff/Someone at ENSC contacted the business 19% 31% 1 Word of mouth: someone in pr...
AI summary Table 5 shows the sources of awareness for energy efficiency programs in Nova Scotia from 2012 to 2014. The primary source was through third-party contractors, followed by ENSC staff and word of mouth. The data highlights the role of different channels in spreading awareness about energy efficiency initiatives.
4.1.2 Custom Retrofit Influence In terms of the project design phase, participants relied on different groups to specify measures, including outside design professionals (4 participants), someone within the participant's organization (3 pa...
AI summary The document discusses how participants in energy efficiency projects relied on various groups to specify measures, with external design professionals being the most common. Factors such as financial incentives, corporate policy, and technical assistance were rated as medium influences on the decision to implement energy efficiency measures.
Table 6: Factors Influencing Participants' Decisions Importance of Factors in Influencing Decision 20 12 2013 2014 to Implement Energy Efficiency Measures Sample Size Mean Sample Size Mean Sample Size Mean Mean (0=Not at all important, 10=...
AI summary Table 6 outlines the importance of various factors influencing participants' decisions to implement energy efficiency measures. Financial incentives and on-bill financing are highly valued, while previous experience with programs and technical assistance are also significant considerations.
\ \ & quot;Don't know/Refused/Not applicable" responses were excluded from calculations. Ten out of the 11 participants worked directly with ENSC, and just one worked through a third-party contractor. Various aspects related to ENSC's perf...
AI summary Ten out of 11 participants worked directly with ENSC, with positive ratings for ENSC's performance. Although mean scores are slightly lower than in 2013, all participants would recommend Custom Retrofit to other businesses and would participate in other ENSC programs.
Table 8: Satisfaction with ENSC Satisfaction with Overall 20- 12 2013 2014 Performance Sample Size Satisfied Sample Size Satisfied Sample Size Satisfied Mean (1=Not at all satisfied, 10=comple tely satisfie d) ENSC's overall performance in...
AI summary Table 8 presents satisfaction ratings for Efficiency Nova Scotia Corporation (ENSC) across various aspects of its performance, including responsiveness, technical expertise, and the value of its Custom Retrofit program. Ratings are provided for different years, showing varying levels of satisfaction with ENSC's services.
5 IMPACT EVALUATION FOR CUSTOM RETROFIT The objective of the 2014 impact evaluation for Custom Retrofit was to determine the gross and net energy savings. Both electrical energy and peak demand savings were estimated by analyzing the follo...
AI summary The 2014 impact evaluation for Custom Retrofit aimed to assess gross and net energy savings by analyzing feasibility studies, M&V reports, on-site visits, and participant feedback, while considering factors like free-ridership and internal spillover.
Lighting Retrofit Projects In 2014, 36 of the 100 projects included lighting retrofit measures, which accounted for approximately 24 percent of the verified energy savings. In order to paint an accurate picture of Custom 2014, 11 of the 25...
AI summary This section discusses the verification process for lighting retrofit projects in 2014, highlighting factors such as unitary wattage, installation rates, hours of operation, diversity factors, and M&V procedures. These factors were used to calculate energy savings and ensure accuracy in the verification process.
Other Energy Efficiency Projects The remaining 2014 Custom projects were grouped into a second category simply named "Other Energy Efficiency Projects", and it included a variety of measures, such as HVAC upgrades, motor replacements, cont...
AI summary The 'Other Energy Efficiency Projects' category includes diverse energy conservation measures, such as HVAC upgrades and motor replacements. The weighted adjustment ratio was calculated based on a detailed review of project documentation and on-site verification of equipment installation and operation parameters.
Adjustments to Lighting Retrofit Projects The adjustment factors for lighting retrofits were determined through the analysis of the information obtained during the 10 on-site visits for lighting retrofit measures. The overall energy and pe...
AI summary Adjustments to lighting retrofit projects were determined based on 10 on-site visits, identifying discrepancies in operation hours, fixture counts, and interactive effects. Energy savings adjustment factor was set at 1.009, and peak demand ratio at 1.142. Recommendations include standardizing M&V plans and focusing verification on larger projects.
Adjustments to Other Custom Retrofit Projects The remaining Custom projects in the sample are classified as "other" Custom Retrofit projects for this report. The tracked savings for each project were adjusted using a similar methodology as...
AI summary The report discusses adjustments to energy and peak demand savings for 'other' Custom Retrofit projects, noting minor discrepancies in energy savings calculations and significant errors in documentation. An overall energy savings adjustment factor of 0.991 was applied, while a peak demand adjustment factor of 0.686 was used, influenced by differences in methods for estimating peak coincidence factors.
Calculation of Adjusted Gross Savings Table 9 details the adjustment factors used by the Evaluator for the overall gross energy and peak demand savings calculations.
AI summary Table 9 outlines the adjustment factors used by the Evaluator to calculate overall gross energy and peak demand savings. This section focuses on the methodology for adjusting savings calculations in the context of energy efficiency programs.
Table 9: Adjustment Factors for Gross Energy and Peak Demand Savings Calculations Adjustment Ratios Project Type Gross Energy Savings Gross Peak Demand Savings Lighting retrofit only 1.009 1.142 Other Custom Retrofit projects 0.991 0.686 I...
AI summary Table 9 presents adjustment factors for gross energy and peak demand savings calculations for different project types. The report indicates that interactive effects related to heating and cooling systems and diversity factors have already been considered in individual project calculations, eliminating the need for further adjustments.
Continued success in the delivery of non-lighting Custom projects will require continued improvement to the application of M&V practices. In a number of cases, M&V activities were not summarized or documented in the DSMDS. More specificall...
AI summary The document highlights the need for improved M&V practices in non-lighting Custom projects, noting that only 13 out of 22 sampled projects included measurements. Savings for the 2014 Custom Retrofit are estimated at 21.279 GWh at the meter and 22.547 GWh at the generator, with peak demand savings of 1.619 MW and 1.716 MW respectively.
5.2.2 Internal Spillover For Custom Retrofit, internal spillover occurs when participants implement eligible energy efficiency measures under the influence of their previous participation in the program, yet without having any kind of addi...
AI summary The 2013 and 2014 evaluations of the Custom Retrofit program found minimal internal spillover, with only 1% identified in 2013 and no significant spillover in 2014. The Evaluator tested new methods, including a web-based survey for free-ridership, but it was not effective due to low response rates. An Embedded Energy Manager (EEM) was investigated for potential spillover, but no significant impact was found.
6 IMPACT EVALUATION FOR EMIS AND EBC EMIS and EBC were two Custom Retrofit components newly introduced in 2014. This limited-scope impact evaluation was conducted on the basis of a technical review of these two sub-components' project docu...
AI summary This section discusses an impact evaluation of EMIS and EBC, two Custom Retrofit components introduced in 2014. The evaluation was based on a technical review of project documentation, with the goal of recommending improvements to the methodology for documenting and calculating savings, as well as ENSC's approach to supporting and verifying these projects.
Suggestions for Improvement To improve the EMIS process and the accuracy of the tracked savings, ENSC should adopt the current version of the IPMVP released by the Efficiency Valuation Organization (EVO). Many of ENSC's staff members are c...
AI summary To improve the EMIS process and the accuracy of tracked savings, ENSC should adopt the current version of the IPMVP from EVO. This would help address weaknesses such as inadequate baseline data collection and incomplete documentation of adjustments. ENSC should also review M&V plans and verify tracked savings in quarterly reports.
6.2 Existing Building Commissioning Review As mentioned previously, EBC was one of the Custom Retrofit components newly introduced in 2014. The goal of this component is to achieve energy and peak demand savings through the appropriate and...
AI summary The Existing Building Commissioning (EBC) program, introduced in 2014, focuses on achieving energy and peak demand savings through low-cost and no-cost measures. An evaluator found that EBC is cost-effective, generating approximately 850 MWh in savings, though project documentation quality varied significantly.
Suggestions for Improvement What follows is a list of recommendations that the Evaluator has made to help ENSC improve EBC. - › Better define the expected scope of the feasibility studies: Although the component's name refers to recommissi...
AI summary The Evaluator has suggested improvements for ENSC's EBC program, including better defining the scope of feasibility studies, requiring documentation of equipment specifications, and providing standardized reporting for service providers to ensure accurate tracking of energy savings and costs.
Table 13: 2014 Net Savings at the Generator of Custom Retrofit, EMIS and EBC Initial Gross Savings Adjusted Gross Savings NTGR Net Savings Energy Savings Tracked Savings from ENSC 29.353 GWh 29.353 GWh 0.93 27.314 GWh Evaluation Results 29...
AI summary The table presents 2014 net savings data from energy efficiency programs, including Custom Retrofit, EMIS, and EBC. The Evaluator made minor adjustments to energy savings, with a 1.2% difference between tracked and evaluated net energy savings. Peak demand savings were adjusted downward by about 14%, largely due to changes in diversity factors and a reduction in the NTGR ratio.
This Appendix presents all recommendations made by the Evaluator throughout the report as well as the sections from which the recommendations originated. Sections Recommendations Executive Summary 1 Perform thorough M&V and document it in...
AI summary The Evaluator recommends thorough M&V for large energy efficiency projects and suggests a simplified approach for smaller ones, emphasizing the need for accurate documentation to justify significant incentives.
Sections Recommendations Program Documentation and Design 7 The Evaluator also recommends continuing to monitor the types of projects submitted to Custom Retrofit in order to identify whether measures of the same type (becoming less custom...
AI summary The document outlines recommendations for improving program documentation and design, including monitoring project types in the Custom Retrofit program and ensuring standardized reporting of energy-saving measures. It also suggests collecting equipment specifications and providing a standardized summary for service providers to report implemented measures accurately.
INTRODUCTION Hello, my name is ______ and I am with CRA (Corporate Research Associates), a Halifax-based survey research company. We are performing an evaluation of energy efficiency services provided by Efficiency Nova Scotia Corporation....
AI summary A representative from CRA is conducting a survey to evaluate Efficiency Nova Scotia Corporation's Custom Retrofit Program, seeking feedback from participants to improve the program. The survey is expected to take about fifteen minutes.
Verification and Recall [V Series] V1. The Custom program helps businesses implement electrical energy-saving projects. The Custom program offers technical assistance, financial incentives and financing to offset the cost of engineering st...
AI summary The text outlines a verification and recall process related to participation in Efficiency Nova Scotia's Custom Program, which provides technical assistance, financial incentives, and financing for energy-saving projects. It asks respondents to confirm participation and identify the most knowledgeable person about their experience with the program.
Reasons for Participating [P Series] - P1. Did your company or organization participate in any other Nova Scotia Power or Efficiency Nova Scotia energy efficiency programs before participation in the Custom Program? CODE ONE ONLY - 1. Yes...
AI summary This section of the document asks participants about their prior involvement in energy efficiency programs, the reasons for joining the Custom Program, and who was responsible for specifying measures during the project design phase. It includes response options for each question.
Free-Ridership [FR Series] According to our information, through its participation in the Custom Program, your business or organization received incentives to implement electrical energy-saving projects in one or several facilities or buil...
AI summary This section of the Free-Ridership survey asks participants whether they had plans to implement energy efficiency measures before joining the Custom Program and assesses the likelihood they would have taken those actions without the program's incentives.
FR2a. implemented exactly the same energy efficiency measures that you implemented through the program? Response 98 Don't Know 99 Refused
AI summary The document asks whether the same energy efficiency measures were implemented through the program, with responses categorized as 'Don't Know' and 'Refused'.
2014 Evaluation Report
AI summary The 2014 Evaluation Report provides an assessment of energy efficiency initiatives and programs implemented during that year, focusing on their effectiveness and impact.
FR2b. installed standard equipment instead of energy-efficient equipment? Response 98 Don't Know 99 Refused FR2c. implemented the energy efficiency measures that you implemented through the program, but at a later date? Response 98 Don't K...
AI summary The text discusses survey questions related to energy efficiency programs, specifically focusing on whether respondents would have implemented energy efficiency measures without the program and the timing of such implementation. It includes response options and follow-up questions for detailed answers.
implemented? Please answer on a scale of 0 to 10, with a 0 indicating that you "Definitely Would Not Have Paid and/or Financed" and a 10 indicating that you "Definitely Would Have Paid and/or Financed." [PROBE FOR SPECIFIC RESPONSE – DO NO...
AI summary The text presents a survey asking respondents to rate on a scale of 0 to 10 their likelihood of having paid and/or financed energy efficiency measures, as well as the importance of factors influencing their decision to implement such measures through a program.
Satisfaction [S Series] - CS1. How did your company first learn of the programs offered by Efficiency Nova Scotia? DO NOT PROVIDE RESPONSE CATEGORIES - CODE AS MANY AS APPLICABLE - 1 . Media advertising - 2. Someone at Efficiency Nova Scot...
AI summary This section of the regulatory proceeding document includes survey questions related to customer satisfaction with Efficiency Nova Scotia programs. It asks how companies learned about the programs, their level of satisfaction with various aspects of the Custom Program, and whether they had direct contact with Efficiency Nova Scotia employees or worked with third-party contractors.
CODE ONE RESPONSE FOR EACH FACTOR - a. The technical expertise of ENSC employees related to the program - b. The responsiveness of ENSC employees to your requests and enquiries in a timely manner - c. The speed with which the application w...
AI summary This section asks respondents to evaluate Efficiency Nova Scotia's performance based on factors such as technical expertise, responsiveness, approval speed, program value, and ability to provide ROI estimates, using a 10-point scale.
[IF CS2 = 2 OR 3 , then ask:] CS30. How satisfied were you overall with the service provided by your third-party contractor on managing the process of securing a payment from Efficiency Nova Scotia? Were you:
AI summary The question asks about satisfaction with the service provided by a third-party contractor in managing the process of securing a payment from Efficiency Nova Scotia.
Barriers to Actions and Recommendations [B Series] - B1. Did you face any challenges or barriers when implementing energy efficiency measures through the Custom Program? - 1. Yes - 2. No (SKIP TO B7) - 98. (Don't know) (SKIP TO B7) - 99. (...
AI summary This section of the proceeding asks respondents about challenges faced in implementing energy efficiency measures through the Custom Program, including approval delays, measurement and verification requirements, and payback time frames. It also seeks suggestions for improving the program's various components and processes.
- P5. What was the SECOND most important reason your company or organization chose to participate in the Custom program? 2012 2013 2014 Motivations for Participating Most Important Motivation (%) Second Most Important Motivation (%) Most I...
AI summary The table presents survey data on the motivations for participating in the Custom program from 2012 to 2014. The most important motivation was saving on energy costs, followed by incentives and environmental protection. The data includes percentages and counts for each year, with sample sizes provided.
Parties Responsible for Specifying Measures 2012 (%) 2013 (%) 2014 (#) Sample Size 27 29 11 Outside design professional 15% 31% 4 Someone within the organization 30% 21% 3 Utility account manager 4% 3% 2 Contractor 33% 17% 1 Manufacturer r...
AI summary The document presents data on the parties responsible for specifying energy efficiency measures from 2012 to 2014, along with the importance of various factors influencing the implementation of energy efficiency measures through a program. The data includes percentages and sample sizes for different groups and ratings on a scale from 0 to 10 for the importance of factors such as financial incentives, technical assistance, and corporate policies.
CS1. How did your company first learn of the programs offered by Efficiency Nova Scotia? Sources of Awareness 2012 (%) 2013 (%) 2014 (#) Sample Size 27 29 11 Internet/ENSC website 7% 14% 4 Energy Manager - - 2 ENSC staff/Someone at ENSC co...
AI summary The table shows how businesses first learned about Efficiency Nova Scotia (ENSC) programs from 2012 to 2014. The primary sources include third-party contractors, ENSC staff, and word of mouth, with varying percentages across the years.
S1. On a scale of 1 to 5, where 1='not at all satisfied' and 5='very satisfied', how was your company or organization's experience with each of the following aspect of the Custom Program? 2012 2013 2014 Aspects of Custom Retrofit Sample Si...
AI summary The document presents survey results evaluating the Custom Retrofit Program from 2012 to 2014, with participants rating their satisfaction on a scale of 1 to 5. Satisfaction levels vary across aspects of the program, with higher satisfaction for overall program experience and lower satisfaction for project savings verification and delays in receiving rebates.
\ \ \ Base: participants who were identified in the sample as scoping, feasibility, or financing. - CS4. Now I will read you a list of factors, and I would like to know how satisfied you were with each in terms of your experience with Effi...
AI summary The text discusses a survey conducted with participants who were involved in scoping, feasibility, or financing stages of a project. The survey asks respondents to rate their satisfaction with various factors related to Efficiency Nova Scotia on a scale from 1 to 10.
- CS5. Now, using the same 10-point scale, how satisfied are you with Efficiency Nova Scotia's overall performance in working with your company? Satisfaction with Overall 20- 2012 2013 2014 Performance Sample Size Satisfied Sample Size Sat...
AI summary The text presents survey results evaluating Efficiency Nova Scotia's (ENSC) performance in working with companies, focusing on satisfaction levels with various aspects such as responsiveness, technical expertise, and the value of Custom Retrofit programs. The data includes mean satisfaction scores from 2012 to 2014.
CS6. Did you speak directly to any of Efficiency Nova Scotia's contact centre representatives? Contact with ENSC Contact Centre Staff 2014 (#) Sample Size 11 Yes 9 No 2 Don't know - \ \ Mean excludes responses of 'Refused' and 'Don't know'
AI summary The document asks if the respondent spoke directly with Efficiency Nova Scotia's contact centre representatives. A table shows that out of 11 respondents, 9 said yes, 2 said no, and none were unsure.
CS28. Based on your company's experience working with Efficiency Nova Scotia and its third-party contractors, would you definitely, probably, probably not, or definitely not participate in other programs offered by Efficiency Nova Scotia?
AI summary The question asks about the likelihood of participation in other programs offered by Efficiency Nova Scotia, based on the company's experience working with Efficiency Nova Scotia and its third-party contractors.
Would Recommend Custom Retrofit to Other Businesses/Companies 2012 (#) 2013 (%) 2014 (#) Sample Size 9 29 11 Definitely 6 97% 7 Probably 3 3% 4 Probably not - - - Definitely not - - - Don't know/refused have been removed from calculation \...
AI summary The table presents survey results from 2012 to 2014 regarding the likelihood of businesses recommending custom retrofits to others. In 2012, 6 out of 9 respondents definitely would recommend, while in 2013, 97% of 29 respondents definitely would recommend, and in 2014, 7 out of 11 respondents definitely would recommend.
CS30. How satisfied were you overall with the service provided by your third-party contractor on managing the process of securing a payment from Efficiency Nova Scotia? Were you: 2012 2013 2014 Satisfaction with Overall Performance Sample...
AI summary The table presents customer satisfaction data regarding the service provided by third-party contractors in managing the process of securing payments from Efficiency Nova Scotia (ENSC) across the years 2012, 2013, and 2014. The sample sizes and number of satisfied respondents are shown for each year.
S10. Thinking of when you first contacted ENSC about the program, or ENSC contacted you, how long, in weeks, was it before you received your rebate or incentive? Length of Time to Receive Rebate or Incentive 2014 (#) Sample Size 7 2-3 week...
AI summary The text asks respondents how long it took, in weeks, to receive a rebate or incentive after first contacting ENSC about a program. It also includes a table showing the distribution of response times and an average of 10.7 weeks. A follow-up question asks about challenges faced when implementing energy efficiency measures through the Custom Program.
Recommendations for Improvements 2013 (%) 2014 (#) Sample Size 27 29 11 Broadening the scope of energy savings, including oil and fuel, other utilities, not just electricity/Offer more products/energy savings options 7% 10% 2 Increase staf...
AI summary The table outlines recommendations for improving energy efficiency programs in Nova Scotia, highlighting areas such as broadening the scope of energy savings, increasing staff knowledge, improving advertising, and simplifying processes. A significant portion of respondents indicated satisfaction with the Custom Retrofit program.
MEAN VALUE OF: (FR2a ; FR2b) IF PRE-SCREENING: 0% FR1. Before participating in Custom, did your company have plans to implement the specific energy efficiency measures that were implemented through the program? IF 1. Yes: Use FR1a IF 2. No...
AI summary The text outlines a series of questions related to energy efficiency program participation, focusing on whether companies had pre-existing plans for energy efficiency measures and how financial incentives influenced their decision to implement them.
100% - [FR4_P/(FR4_P+FR4_NP)] FR2c. If your company had not participated in Custom, what is the likelihood that you would have implemented the energy efficiency measures but at a later date? (Scale 0 to 10) IF FR2c > 5 : ASK FR2dd Otherwis...
AI summary This section asks respondents about the likelihood of implementing energy efficiency measures without the Custom program and the potential delay in implementation if they had not participated. It uses a scale from 0 to 10 and provides options for different timeframes of delayed implementation.
APPENDIX V INTERNAL SPILLOVER METHODOLOGY Internal spillover was measured using on-site visits. Participants were asked whether following their participation in the program, they implemented any additional energy efficiency measures, witho...
AI summary Internal spillover was measured through on-site visits, where participants were asked if they implemented additional energy efficiency measures outside of rebate programs. The influence of the program on these measures was quantified to determine the portion of savings attributable to the program, and internal spillover was calculated by dividing this attributable savings by total program savings.
Savings Equations Documentation of the energy and demand savings calculations consisted of ENSC's standardized lighting retrofit workbook. All of the key project variables were listed in the workbook, and the savings calculations were base...
AI summary The energy and demand savings calculations are documented using ENSC's standardized lighting retrofit workbook. The workbook lists key project variables and calculates annual savings by comparing equipment performance before and after implementation.
Net Electrical Savings - = $[(Fixture\ Qty\ \times\ Fixture\ Wattage\ \times\ Annual\ HOUs)_{Existing}]$ - (Fixture Qty $\times$ Fixture Wattage $\times$ Annual HOUs) New ] $\pm$ Interactive Effects Interactive Effects = Cooling Bonus - He...
AI summary The document presents a formula for calculating Net Electrical Savings, which involves subtracting the new fixture energy consumption from the existing one, adjusted by interactive effects such as cooling bonuses and heating penalties.
Cooling Bonus - $= [(Electrical\ Consumtpion_{Existing} \times Space\ Fraction_{Existing})]$ - (Electrical Consumtpion New $\times$ Space Function New )] - $\times$ (Percent of Year/COP Cooling )
AI summary The text presents a formula for calculating the Cooling Bonus, which involves electrical consumption, space fraction, percent of the year, and the coefficient of performance for cooling.
Heating Penalty - = Heat Gain Factor - $\times$ [(Fixture Qty $\times$ Fixture Wattage $\times$ Annual HOUs) Existing - $\; (\textit{Fixture Qty} \; \times \; \textit{Fixture Wattage} \; \times \; \textit{Annual HOUs})_{\textit{New}} \big]$
AI summary The text presents a formula for calculating the 'Heating Penalty,' which involves the Heat Gain Factor and the product of fixture quantity, fixture wattage, and annual hours of operation for both existing and new fixtures.
Net Demand Savings = $$(Fixture\ Qty \times Fixture\ Wattage \div 1000 \frac{W}{kW})_{Existing}$$ - $(Fixture\ Qty \times Fixture\ Wattage \div 1000 \frac{W}{kW})_{New}$
AI summary The text presents a formula for calculating Net Demand Savings, which involves subtracting the new fixture quantity and wattage from the existing values, converted from watts to kilowatts. An image is referenced but not described.
Tracked Savings Calculation This project involved replacing high bay metal halide fixtures with more efficient high bay T8 fixtures. ENSC calculated the tracked savings for this project by applying the lamp wattage of the existing fixtures...
AI summary This project involved replacing inefficient high bay metal halide fixtures with more efficient T8 fixtures. Tracked savings were calculated based on lamp wattage, annual hours of operation, and the absence of heating and cooling adjustments. The results of consumption measurements are summarized in a table.
Table 14: Tracked Savings Values Baseline Energy Consumption (kWh) 72,408 Post-retrofit Energy Consumption (kWh) 37,279 Tracked Gross Energy Savings (kWh) 35,129 Baseline Demand (kW) 21.400 Post-retrofit Demand (kW) 10.560 Tracked Gross De...
AI summary Table 14 provides tracked savings values before and after retrofits, including energy consumption, demand, and diversity factors. The revised savings calculation highlights reductions in energy use and peak demand following retrofitting efforts.
Adjustments to the energy savings were made based on a minor correction of the count of lights a modification of the hours of operation (HOUs) (based on the facility manager's declaration), and a correction to the base equipment wattages t...
AI summary Adjustments to energy savings calculations were made based on corrections to the number of lights, hours of operation, and equipment wattages. The revised demand savings were calculated using a diversity factor of 0.40, leading to an increase in savings of 28,963 kWh/year and 3.28 kW before applying the diversity factor.
ojects has resulted in four relatively medium-sized groups, and two larger groups that each represents nearly twice the annual savings of the four smaller categories. The two largest groups are lighting retrofits and HVAC upgrades, and the...
AI summary The sampling methodology has grouped energy efficiency projects into six categories, with lighting retrofits and HVAC upgrades being the largest groups. This approach ensures representation and balance across all project types, with a table showing savings by category and as a percentage of total tracked savings.
Table 17: Sampled Projects by Category Category Name Count by Category Sum of Energy Savings (kWh/year) Percentage of Total Savings (%) Compressed air 3 969,946 10% HVAC 4 1,420,665 15% Lighting 18 2,523,336 26% Multiple 5 2,793,051 29% Ot...
AI summary Table 17 presents sampled energy efficiency projects by category, highlighting lighting as the largest contributor to energy savings. ENSC has introduced three program tracks within Custom Retrofit to manage projects based on complexity and size, with Track 2 for large projects and a dedicated track for compressed air systems.
Applying these four sampling criteria, the Evaluator has established a list of 25 projects to be visited. The following table shows a comparison of the sample and the total population of Custom Retrofit projects and their respective progra...
AI summary The Evaluator has selected 25 Custom Retrofit projects based on four sampling criteria, with a table comparing these sampled projects to the total population and their program savings.
Table 18: Comparison of Custom Retrofit Program Population and On-site Visit Sample 7 Description Number of Projects Expected Gross Energy Savings at the Generator (GWh/year) Expected Gross Demand Savings at the Generator (MW) Population 4...
AI summary Table 18 compares the Custom Retrofit Program population and on-site visit sample, showing 44 projects in the population and 25 in the sample. Expected energy and demand savings are also provided, with percentages of tracked projects in each category as of October 2014.
DEFINITIONS Billing calibration An activity that consists in adjusting the expected energy savings based on the relative difference between the results of the building energy simulations and the actual energy consumption of the building. D...
AI summary The text defines key terms related to energy efficiency program evaluation, including billing calibration, distortion effects, free-ridership, gross and net energy savings, and net-to-gross ratio. These definitions are used to measure and evaluate the impact of energy efficiency initiatives.
Program component Overview Efficiency Nova Scotia Corporation's (ENSC) Custom NC provides business, non-profit and institutional (BNI) customers with incentives to help them achieve significant and predictable electrical savings in new com...
AI summary Efficiency Nova Scotia Corporation's Custom NC program provides incentives to BNI customers for energy efficiency in new commercial or industrial buildings and renovations. The program aimed for 4.6 GWh of electrical energy savings and 1.1 MW of peak demand savings in 2014.
2.2.2 Billing Calibration For 2014, ENSC collected actual energy consumption and demand data of buildings from the 2012 and 2013 evaluations to compare them with the proposed case energy consumption and demand figures simulated before proj...
AI summary In 2014, ENSC compared actual energy consumption and demand data from 2012 and 2013 evaluations with simulated figures to verify building simulations and improve energy savings tracking procedures under Custom NC, following best practices like the IPMVP.
Measures by Category The information contained in the Measures by Category tab was identical to the Measures by Project tab, but was presented in a manner that focused on the types of projects implemented. The benefit to the Evaluator was...
AI summary The 'Measures by Category' tab provides the same information as the 'Measures by Project' tab but organizes it by project types, helping the Evaluator better understand which energy efficiency measures are responsible for savings in Custom NC projects.
Measures The Measures tab in the DSMDS provides a summary table of the energy savings and implementation costs of an individual project. The energy savings section provides necessary information required to assess and verify the tracked sa...
AI summary The Measures tab in the DSMDS summarizes energy savings and implementation costs for individual projects, including power factor and diversity factor. It also tracks non-electrical benefits and equipment details, showing a commitment to improving data collection for individual measures.
Documents The Documents tab contains the most detailed information about the 2014 Custom Retrofit projects, and typically includes the modelling summary report, the ENSC NC-EM2 Excel document, relevant calculation workbooks and other proje...
AI summary The Documents tab contains detailed information on the 2014 Custom Retrofit projects, including reports and project communications. While file-naming conventions are not standardized, document types and names are used for navigation. Missing files are stored internally and made available upon request. The Evaluator concludes the tracking system is adequate and improving, with recommendations for adding Nova Scotia Power's rate code and explaining diversity factor calculations.
4 IMPACT EVALUATION The objective of the 2014 Custom NC impact evaluation was to determine the gross and net savings. Both electrical energy and peak demand savings were estimated by analyzing the following: - › Feasibility studies, buildi...
AI summary The 2014 Custom NC impact evaluation aimed to assess gross and net savings from energy efficiency measures, analyzing feasibility studies, energy model simulations, M&V reports, interviews, billing calibration results, and free-ridership data. The evaluation involved reviewing nine project files, on-site visits, and participant interviews.
4.1.1 Adjustment Methodology Nine on-site visits were conducted with the intent of confirming that the tracked savings recorded in the DSMDS were appropriate and accurate using a similar approach than the one used in 2013. The on-site visi...
AI summary The document outlines the adjustment methodology used to verify the accuracy of energy savings recorded in the DSMDS through on-site visits. Key factors considered include baseline assumptions, equipment specifications, installation rates, hours of operation, diversity factors, and M&V procedures for NCEM projects.
4.1.3 Adjusted Gross Savings The 2014 gross energy savings presented in the ENSC tracking sheet for each project visited were individually revised according to the adjustments identified by the Evaluator. Adjustment calculations were perfo...
AI summary The 2014 gross energy savings for the Custom NC program were adjusted based on on-site evaluations. Adjustments were made to nine of thirteen projects, including a significant adjustment for a LEED® NC certified building and another for incorrect lighting installation. Peak demand savings were difficult to evaluate due to limited information in simulation reports.
Calculation of Adjusted Gross Savings To calculate the adjustment ratio, the Evaluator used eight of the nine projects reviewed. The LEED project savings that had not been adjusted to take into account the LEED energy performance requireme...
AI summary The document discusses the calculation of an adjustment ratio for gross energy and peak demand savings, excluding a LEED project due to its unique certification requirements. The adjustment ratios calculated were 0.982 for energy savings and 0.976 for peak demand savings, based on eight projects. The savings at the meter and generator levels are also detailed, with specific values provided for Custom NC.
Table 4: Comparison of Tracked and Evaluated Savings at the Generator Initial Gross Savings Adjusted Gross Savings NTGR Net Savings Energy Savings Tracked Savings from ENSC 7.122 GWh 7.122 GWh 1.00 7.122 GWh Evaluation Results 7.122 GWh 6....
AI summary Table 4 compares tracked and evaluated savings from Energy Efficiency Nova Scotia Corporation (ENSC) projects. Adjustments to gross energy and peak demand savings were minimal, with only two of nine projects experiencing significant adjustments. The table highlights the Net-to-Gross Ratio (NTGR) and Net Savings for both energy and peak demand.
Savings Equations Tracked Appliance Energy Savings - = (2004 EnerGuide Average Annual Applicance Consumption - Proposed EnerGuide Appliance Consumption) $\times$ Number of Appliances Revised Appliance Savings - = (2004 EnerGuide Average Ap...
AI summary The text outlines equations for calculating appliance energy savings, including tracked appliance energy savings, revised appliance savings, and an adjustment factor. These calculations are based on EnerGuide consumption data from 2004 and the number of appliances.
Tracked Savings Calculation ENSC calculated savings based on the difference between the annual energy consumption of the proposed appliances and the EnerGuide 2004 average for the same appliances. The tracked savings values for the project...
AI summary ENSC calculated tracked energy savings for fridges and stoves by comparing the annual energy consumption of proposed appliances with the EnerGuide 2004 average. The total tracked energy savings for the project are 11,826 kWh/year.
Revised Savings Calculation During the on-site visit, the Evaluator confirmed that the proposed appliances had not been installed, and that high consumption replacements were carried out on site. The revised savings were calculated using t...
AI summary During an on-site visit, it was found that proposed energy-efficient appliances were not installed, and higher consumption replacements were made. Revised energy savings were calculated based on the actual appliances installed, leading to an adjustment of -8,100 kWh/year in tracked energy savings.
Table 5: Final Sample for Custom NC 5 Description Number of Projects Expected Gross Energy Savings at the Meter (GWh/yr) Expected Gross Demand Savings at the Meter (MW) Sample 9 3.977 1.343 Final Tracked Projects 13 6.696 2.462 On-site Vis...
AI summary Table 5 provides a comparison between a sample and final tracked projects under the Custom NC5 initiative, showing energy and demand savings. The On-site Visit Protocol section outlines procedures for site visits.
On-Site Visit Protocol 1. General Information Site Visit Date: Project ID: Project Type: Project Status: Project Name: Address: Contact Name: Contact Title: Contact Phone: Email: List of people met during the visit: Type of building: Comme...
AI summary This document outlines the On-Site Visit Protocol, providing a structured format for gathering information during facility visits. It includes sections for general information, key project variables, and facility operation schedules, allowing for detailed data collection on building types, occupancy patterns, and operational schedules.
Fill the table below for each cooling system at the site. Description Cooling System 1 Cooling System 2 Cooling System 3 Cooling Energy Source Cooling System Type Nominal Capacity SEER or COP If any, changes in building set points (occ./ u...
AI summary The text provides a table template to be filled out for each cooling system at a site, including details such as energy source, system type, nominal capacity, and set points. The context includes known acronyms related to energy efficiency and building standards.
On-Site Energy Assessment and Implementation Processes Five visits were conducted with DAs as part of the evaluation process. One visit with each DA was conducted during the initial on-site assessment of a facility. The three other visits...
AI summary Five visits were conducted with Delivery Agents (DAs) during the on-site assessment and installation of energy efficiency measures. The DAs followed ENSC's procedures and recorded relevant data, such as fixture details and energy sources. However, light intensity analysis was not performed, and participants had questions about obtaining replacement lamps, which should be addressed in the future.
The evaluation revealed that BES, including RP&C Common Areas and LED Blitz, generated net energy savings of 13.175 GWh and peak demand savings of 2.570 MW at the generator in 2014.
AI summary The evaluation found that the Business Energy Solutions (BES) program, including initiatives like RP&C Common Areas and the LED Blitz, achieved significant energy and peak demand savings in 2014, with 13.175 GWh of energy savings and 2.570 MW of peak demand reduction at the generator level.
Table 2: Overall Comparison of Tracked and Evaluated Savings at the Generator for BES Initial Gross Savings Installed Gross Savings Installed Gross Savings with Interactive Effects NTGR Net Savings Energy Savings Tracked Savings from ENSC...
AI summary Table 2 compares tracked and evaluated savings from Business Energy Solutions (BES) programs, including energy and peak demand savings. It shows discrepancies between initial gross savings and net savings after accounting for interactive effects, with Net-to-Gross Ratios (NTGR) indicating the efficiency of savings realization.
done by the third-party contractor. Survey results showed that participants encountered issues with third-party contractors and the quality of their work. ENSC already requires that the DAs follow up with customers after installation to en...
AI summary The text discusses issues with third-party contractors and the quality of work in energy efficiency programs. It highlights the need for ENSC to conduct follow-up calls and include a lighting intensity analysis in on-site assessments to improve participant satisfaction and ensure proper implementation of energy efficiency measures.
2 METHODOLOGY This section presents the Econoler team, the methodology used and the activities carried out for the BES evaluation.
AI summary This section introduces the Econoler team and outlines the methodology and activities used for the Business Energy Solutions (BES) evaluation.
2.2.1 On-site Visits In October and November 2014, Equilibrium Engineering conducted 50 on-site visits after project implementation. These visits were meant to verify the implementation status of the measures against the data found in the...
AI summary Equilibrium Engineering conducted 50 on-site visits in 2014 to verify the implementation of energy efficiency measures and calculate installation rates. Five additional visits were conducted with Delivery Agents to validate the turnkey implementation process, using a different protocol.
3.1 Participation in BES As Figure 2 illustrates, the participation in BES has declined since 2012, but has remained rather stable compared to 2013, all BES initiatives considered. This decrease after 2012 can be partially explained by the...
AI summary Participation in the Building Efficiency Program (BES) has declined since 2012, with a significant drop after the removal of the Commercial Direct Install (CDI) component. The number of participants remained relatively stable from 2012 to 2014, with varying numbers implementing lighting and non-lighting measures, MURB Common Area measures, and participating in the LED Blitz pilot.
energy savings and the values of key parameters required to validate the energy savings calculations. The following is a list of the parameters documented for both the existing and proposed measures: - › Number of fixtures - › Number of la...
AI summary The document discusses changes in how energy savings from lighting measures are tracked, particularly regarding occupancy sensors. Since 2013, occupancy sensors are now claimed through a reduction in operating hours rather than a separate field. The 'BES Measure Occupancy Sensor Savings' field is suggested for removal due to inconsistencies.
3.3 On-site Visit during the Installation Process Similar to 2013, five visits were conducted with DAs as part of the evaluation process. Two visits with two different DAs were conducted during the initial on-site assessment of a facility....
AI summary The document details on-site visits conducted by DAs during the installation process of energy efficiency measures. Initial assessments evaluated energy savings opportunities and lighting measures, while installation visits identified products used and encountered issues. Recommendations include adding a lighting analysis and providing clearer information on replacement lamps.
4.1.1 Motivations and Barriers to Participation Businesses and organizations chose to participate in BES for a number of reasons. Like previous years, "saving on energy costs" was identified as the most important motivation. [Table 5](#pag...
AI summary Businesses and organizations participate in the Building Efficiency Program (BES) primarily to save on energy costs. Table 5 outlines various motivations for participation.
Table 5: Reasons for Participating 2012 2013 2014 Reason for Participating Most Important Motivation Second Most Important Motivation Most Important Motivation Second Most Important Motivation Most Important Motivation Second Most Importan...
AI summary Table 5 presents data on the reasons participants joined energy efficiency programs from 2012 to 2014. The primary motivation for participation was saving on energy costs, with percentages fluctuating slightly over the years. Other reasons, such as improving lighting conditions and energy efficiency, were less significant. The data shows an increase in reported barriers to participation over time.
Table 6: Barriers to Participation Any Barriers 2012 2013 2014 Sample Size 76 61 62 No 97% 84% 76% Yes 3% 16% 23% Don't know - - 2% Those participants who mentioned barriers to BES mentioned a variety of issues. Issues like problems with c...
AI summary Table 6 shows a decrease in the percentage of participants reporting no barriers to the Building Efficiency Program (BES) from 97% in 2012 to 76% in 2014. Participants who mentioned barriers cited issues with contractors, unavailability of measures, lack of financing, and incomplete work. These issues suggest that third-party contractors may have quality problems, and ENSC may need to follow up with participants to verify completion of work.
Table 7: Specific Barriers to Participation 2012 2013 2014 Specific Barrier Most Important Barrier (#) Second Most Important Barrier (#) Most Important Barrier (#) Second Most Important Barrier (#) Most Important Barrier (#) Second Most Im...
AI summary Table 7 outlines specific barriers to participation in the Building Efficiency Program (BES) from 2012 to 2014. Key barriers include problems with contractors, lack of financing, and delays in project approval, among others, with varying frequencies across years.
Table 8: Satisfaction with BES Overall Satisfaction with BES 2012 2013 2014 Sample Size 76 59 62 Overall program 95% 97% 90% \ Base: Percentage of respondents who were very satisfied/satisfied Some respondents mentioned issues with timelin...
AI summary The table shows satisfaction rates with the Building Efficiency Program (BES) from 2012 to 2014, with overall satisfaction remaining high but declining slightly in 2014. Some respondents expressed dissatisfaction due to long wait times for contract receipt, with nearly one-third waiting over a month and two respondents waiting over a year. ENSC considers 30 days an acceptable timeframe for contract delivery.
4.1.3 Recommendations for Improvement As shown in [Table 10,](#page-94-0) most participants did not offer any suggestions to improve BES (66%). That said, the issues previously identified were mentioned again, such as "better communication...
AI summary Most participants did not offer suggestions to improve the Building Efficiency Program (BES), with 66% providing no input. However, previously identified issues such as 'better communication', 'increased advertising', and 'better quality control' were reiterated as areas for improvement.
5 IMPACT EVALUATION The objective of the 2014 BES impact evaluation is to determine the gross and net energy savings associated with the measures implemented through BES, including the BES lighting and non-lighting measures, as well as mea...
AI summary The 2014 BES impact evaluation assesses energy savings from lighting and non-lighting measures, as well as common area and LED Blitz initiatives. It considers factors like unitary savings, installation rates, diversity factors, and free-ridership. Data from on-site visits, surveys, and previous evaluations are used to calculate net-to-gross ratios for the programs.
5.1 Gross Energy Savings The following sections examine the unitary savings values used in the gross savings calculations for each category of measures covered by the program (BES lighting measures, BES non-lighting measures, RP&C Common A...
AI summary This section discusses the unitary savings values used in gross energy savings calculations for various program measures, including BES lighting, BES non-lighting, RP&C Common Areas, and LED Blitz measures.
5.1.1 Unitary Savings for BES Lighting Measures Each existing and proposed lighting measure is unique and has its own unitary wattage value. Specific information about the lighting measure is required to allow validating each of these unit...
AI summary The document discusses the unitary wattage values for lighting measures under the Building Efficiency Program (BES). It outlines the data required for existing and proposed measures, including details like the number of fixtures, lamp wattage, and replacement types. The focus is on LED T8 lamps, which account for a significant portion of energy savings.
LED T8 Lamps for Replacement of Fluorescent T8 Lamps Most of the 4' T8 linear LED lamps used to replace fluorescent are Philips InstantFit 14.5 W LED T8 lamps. The Evaluator conducted desktop research to determine the actual tube wattage v...
AI summary The document discusses the replacement of fluorescent T8 lamps with LED T8 lamps, focusing on wattage values and compatibility with ballasts. Philips InstantFit lamps are highlighted, with their wattage rounded for DSMDS entry. SubstiTube lamps are also mentioned with a higher wattage and compatibility requirements.
Unitary Savings for LED Lamp Replacements As for the relamping measures, the savings in the 2014 tracking system are solely based on the wattage differences between the existing and the new lamp types, which is similar to the procedure use...
AI summary The document discusses the calculation of unitary savings for LED lamp replacements, emphasizing the importance of considering the ballast factor and ballast efficacy factor (BEF) in determining system wattage. It notes that existing databases are not sufficient for LED systems and proposes an equation to estimate system wattage when LED tubes are used.
Unitary Savings for LED Lamp and Ballast Replacements For measures that involve replacing the lamps and the ballast, savings presented in the tracking report are based on existing measures related to decommissioned equipment wattage and pr...
AI summary The document outlines the method for calculating energy savings from replacing LED lamps and ballasts. It emphasizes the use of ballast efficacy factors for accuracy and recommends alternative calculations if this data is unavailable. The approach differs from relamping measures due to the complexity of ballast replacements.
Unitary Savings for LED Fixture Replacements Savings presented in the tracking report for this type of measures are calculated using the same method as the one used for LED lamp and ballast replacements. Again, the Evaluator recommends usi...
AI summary The document discusses the method for calculating unitary savings for LED fixture replacements, emphasizing the use of the ballast efficacy factor for accuracy. If unavailable, system wattage is estimated using a recommended ratio of 0.85. Adjustments were made based on this method, resulting in an adjustment ratio of 0.968 for certain measures.
Unitary Savings for Other LED Products Other LED measures were analyzed to verify the accuracy of their unitary wattage values and the ballast factors. The unitary wattage values were found to be consistent with the nominal wattages of the...
AI summary The analysis of other LED products found consistent unitary wattage values but discrepancies in ballast factors. Most LED measures had a ballast factor of 1, but some, like 12 watt A lamps, had a ballast factor of 0. The Evaluator suggests ENSC ensure consistency in ballast factors, though no adjustment is needed for energy savings calculations.
T8 Fluorescent Lamps As part of 2013 evaluation, a literature review was undertaken to evaluate the typical "total fixture wattage/nominal lamp wattage" ratio when low-factor ballasts are used in T8 fluorescent systems. The goal was to eva...
AI summary A 2013 evaluation reviewed the use of low-factor ballasts in T8 fluorescent systems and recommended using a ballast factor of 0.85 instead of 0.74 to 0.78 for more accurate energy savings calculations. This change led to an adjustment ratio of 0.931 for the fluorescent T8 measure category.
Calculation Validation The Evaluator compared the savings recorded in the tracking sheet with the savings established through the engineering calculation using the parameters entered in the tracking sheet and found small errors among the 8...
AI summary The Evaluator identified small errors in the savings recorded across 8,276 records, leading to a 1.9 percent adjustment to the gross savings after comparing tracking sheet data with engineering calculations.
Installation Rate For this year's BES impact evaluation, 44 on-site visits were conducted for lighting measures. At each site, the quantity of products installed was validated against the quantities claimed in the tracking sheet. In situat...
AI summary The document discusses the evaluation of the BES program for this year, including 44 on-site visits to validate the installation of lighting measures. An installation rate was calculated for each measure category based on the proportion of products installed compared to the quantities claimed in the tracking sheet.
Table 11: Installation Rates for BES Lighting Measures Category Number of Sites Visited Total Quantity from the 44 Sampled Sites Total Quantity Validated During On site Visit Total Quantity Installed % Evaluated % Installed Margin of Error...
AI summary The table presents the installation rates for various lighting measures under the Building Efficiency Program (BES). The installation rates for most categories are close to 100%, except for CFLs, which have a higher margin of error of 20.4%, leading to a 100% calculation rate for this category.
5.1.2 Unitary Savings for BES Non-lighting Measures The following are the non-lighting measures eligible under BES in 2014: - › Ductless mini-split heat pumps - › ECM - › Outdoor air economizers - › Hot water heat pumps - › Hot water tank...
AI summary This section outlines the non-lighting measures eligible under the Building Efficiency Program (BES) in 2014, including ductless heat pumps, hot water heat pumps, and pipe insulation, among others. It notes that only these measures were installed in 2014, so the unitary savings review will focus on them.
Where: - › Capacity: This is the nominal heating capacity of the heat pump (kBTU/hr). - › Heating Seasonal Performance Factor (HSPF): For the old equipment, the HSPF is estimated at 3.412, based on the assumption that electric baseboard he...
AI summary The document discusses the calculation of energy savings for heat pumps using parameters such as capacity, HSPF, and full load hours. It references the 2014 BER CIRx Screening Tool and the Efficiency Vermont TRM, while noting a discrepancy between ENSC's use of 2,200 hours and a recommended 2,750 hours based on industry standards.
Hot Water Tank Wraps A total of 93 tank wraps were installed in 2014.
AI summary In 2014, a total of 93 hot water tank wraps were installed as part of energy efficiency initiatives.
Revised Savings Since no site visit was conducted for RP&C Common Areas or for this specific BES measure, the unitary savings value of 118 kWh remains unchanged.
AI summary The unitary savings value of 118 kWh for the RP&C Common Areas and BES measure remains unchanged as no site visit was conducted.
Pipe Insulation A total of 215 six-foot pieces of pipe insulation were installed in 2014.
AI summary In 2014, a total of 215 six-foot pieces of pipe insulation were installed as part of energy efficiency initiatives.
Vending Machine Misers This product is a control device for old beverage vending machines. Equipped with an occupancy sensor, the vending miser alters the performance of the device following a period of inactivity by turning off the machin...
AI summary The Vending Machine Misers are control devices installed in beverage vending machines to reduce energy use by turning off lights and cycling the compressor based on ambient temperature. A total of 62 units were installed in 2014, with 95% of purchases made for a single client across multiple locations.
5.1.3 Unitary Savings for RP&C Common Areas In addition to the measures mentioned above, measures implemented in RP&C Common Areas were also accounted for in BES in 2014. The lighting measures are presented first and include the following:...
AI summary This section discusses energy efficiency measures implemented in RP&C Common Areas in 2014, including lighting upgrades and domestic hot water reduction initiatives. It provides a formula for calculating annual unitary savings based on wattage differences and usage patterns.
CFLs In the RP&C tracking sheet, the quantity of CFLs installed is recorded by lamp type (e.g., regular or dimmable) and wattage. The following five types of CFLs are listed in the 2014 tracking sheet: - > 13-watt CFLs - > 14-watt CFLs & l...
AI summary The document discusses the tracking of Compact Fluorescent Lamps (CFLs) installed under the RP&C program, noting that they are recorded by lamp type and wattage. Five types of CFLs are listed in the 2014 tracking sheet, including various wattage and dimmable options.
LIGHT OUTPUT EQUIVALENCY INCANDESCENT BULBS (WATTS) MINIMUM Light Output (Lumens) COMMON ENERGY STAR QUALIFIED LIGHT BULBS (WATTS) 40 450 9 то 13 60 800 13 10 15 75 1,100 18 TO 25 100 1,600 23 то 30 150 2,600 30 то 52 Hours of Operation
AI summary The table provides light output equivalency between incandescent bulbs and common Energy Star qualified light bulbs, showing lumens and wattage for different bulb sizes. It includes information on minimum light output and the corresponding wattage ranges for energy-efficient alternatives.
Table 12: Unitary Savings Values for Each Type of CFLs Type of CFL Old Wattage (W) New Wattage (W) Displaced Wattage (W) Hours of Operation (hrs/day) Tracked Unitary Savings Value (kWh/year) 13W CFL (Indoors) 60.0 13.0 47.0 2.68 46.0 14W C...
AI summary Table 12 presents unitary savings values for different types of compact fluorescent lamps (CFLs), showing the energy savings achieved by replacing older, higher-wattage bulbs with more efficient CFLs. The table includes data on wattage displacement, hours of operation, and annual energy savings in kilowatt-hours.
Low-flow Showerheads and Showerwands For low-flow showerheads and showerwands, a 330 kWh value, equivalent to that of the products installed under RP&C tenant units, is applied.
AI summary The document specifies that a 330 kWh value is applied to low-flow showerheads and showerwands, equivalent to the value of products installed under RP&C tenant units.
Faucet Aerators The same unitary savings as for faucet aerators installed in RP&C tenant units are applied to the common areas faucet aerators, at 122 kWh per unit.
AI summary The unitary savings for faucet aerators installed in RP&C tenant units are also applied to common areas, with a saving of 122 kWh per unit.
5.1.4 Unitary Savings for LED Blitz Pilot The remaining energy-efficient lighting and non-lighting measures of the LED Blitz pilot were implemented at the beginning of 2014. To verify the claimed savings resulting from these installed meas...
AI summary The LED Blitz pilot's remaining energy-efficient measures were implemented in early 2014. Savings were verified using unitary savings values from the 2013 evaluation, except for the 7-Watt MR16, which required a new review due to lack of prior evaluation.
LED Blitz Lighting Measures The LED Blitz initiative included the following eligible lighting products: - › LED A-Lamp - › LED MR16 - › LED GU10 - › LED BR30 - › LED BR40 - › LED PAR20 - › LED PAR30 - › LED PAR38 - › LED exit sign - › LED...
AI summary The LED Blitz initiative includes various eligible lighting products such as LED A-Lamp, LED MR16, LED GU10, and others, aimed at promoting energy-efficient lighting solutions.
Table 14: Tracked Unitary Savings Values for Each LED Lamp Category LED Lamp Category Old Wattage (W) New Wattage (W) Displaced Wattage (W) Hours of Operation (h/day) Unitary Savings Value (kWh/year) 8-Watt A-Lamp 50 8 42 12.8 196.6 12-Wat...
AI summary Table 14 presents unitary savings values for various LED lamp categories, including old and new wattages, displaced wattage, hours of operation, and annual savings in kWh. The table assumes 12.8 hours of operation per day for most categories, based on the specific types of businesses where the LED products were installed.
Table 15: Calculation of Unitary Savings Associated with Faucet Aerators Type of Commercial Facility Proportion in the 2012 CDI Tracking Sheet Unitary Savings (kWh/year) Hotel 29% 93 Restaurant 12% 1,561 Office 8% 68 Retail 8% 180 School 3...
AI summary Table 15 provides the calculation of unitary savings associated with faucet aerators across different types of commercial facilities, including hotels, restaurants, offices, retail, schools, and others, with an average unitary savings of 261 kWh/year.
Diversity Factor Based on information provided by ENSC, the peak period for electricity demand in Nova Scotia occurs weekdays from 7 a.m. to 12 p.m. and 4 p.m. to 11 p.m. in December, January and February. Similar to evaluations completed...
AI summary The document discusses the determination of diversity factors for energy efficiency measures in Nova Scotia, including lighting and heat pump installations. It outlines how peak demand periods are identified and how diversity factors are calculated based on operational schedules and building types.
5.3 Revised Gross Savings The Evaluator revised the gross energy and peak demand savings calculated in the BES final tracking system for each main category of the program.
AI summary The Evaluator revised the gross energy and peak demand savings calculated in the BES final tracking system for each main category of the program.
5.3.1 Revised Gross Savings for BES Lighting Measures As presented in section 5.1.1, the Evaluator revised the gross energy and peak demand savings of BES lighting measures calculated in the final tracking system based on the adjustments m...
AI summary The document discusses the revised gross energy and peak demand savings for BES lighting measures, highlighting adjustments due to calculation errors, self-declaration ratios, installation rates, and diversity factors. Line loss factors were applied to account for electricity losses, and total savings are estimated at 13.058 GWh and 2.331 MW at the meter, and 13.972 GWh and 2.495 MW at the generator.
Table 16: Evaluation of Gross Energy and Peak Demand Savings Associated with BES Lighting Measures LEC )s Fluoresc ent T8 F N4 - 4 - 1 Category of Product Reballast (linear) Other Reballast Other CFLs Custom Т5 Exit Signs Metal Halide Othe...
AI summary Table 16 evaluates the gross energy and peak demand savings associated with BES lighting measures, including various product categories and their corresponding savings metrics. The table includes initial and calculated tracked savings, demand savings, and adjustments based on factors like ballast, installation rates, and line loss.
5.3.2 Revised Gross Savings for BES Non-lighting Measures The Evaluator revised the gross energy and peak demand savings calculated for the BES non-lighting measures (section 5.1.2) based on the adjustments made to the following: - › Adjus...
AI summary The Evaluator revised the gross energy and peak demand savings for BES non-lighting measures based on adjustments to heat pump and pipe insulation ratios, installation rates, and diversity factors. A line loss factor of 1.084 was applied to account for electricity losses between the meter and the generator, with Nova Scotia Power providing the line loss factors for each rate code.
Table 17: Evaluation of Gross Energy and Peak Demand Savings Associated with BES Non-lighting Measures Category of Product Heat Pumps Hot Water Tank Wraps Pipe Insulation Vending Machine Misers Hot Water Heat Pumps Total Tracked Energy Sav...
AI summary Table 17 evaluates the gross energy and peak demand savings from non-lighting measures under the Building Efficiency Program (BES). It includes energy savings from heat pumps, hot water tank wraps, pipe insulation, vending machine misers, and hot water heat pumps, with metrics like tracked energy savings, installation rates, and unitary savings values.
Table 18: Evaluation of Gross Energy and Peak Demand Savings Associated with RP&C Common Areas (CFLs) Category of Product 13-Watt CFL 14-Watt CFL 23-Watt CFL 14-Watt Dim. CFL 16-Watt Dim. CFL 3-Watt LED Chandelier 10-Watt LED A lamp 9-Watt...
AI summary Table 18 evaluates the gross energy and peak demand savings associated with the installation of various lighting products in RP&C common areas, including CFLs and LEDs. The table provides data on the number of units installed, energy savings, peak demand savings, and factors such as line loss and diversity.
5.3.4 Revised Gross Savings for LED Blitz The annual gross savings calculated for each category of product installed through LED Blitz are presented in [Table 20](#page-123-0) for lighting measures and in [Table 21](#page-124-0) for non-li...
AI summary The document discusses revised gross savings for the LED Blitz program, presenting energy and peak demand savings at both the meter and generator levels. Calculations were based on unitary savings values and a line loss factor provided by Nova Scotia Power.
Table 20: Evaluation of Gross Energy and Peak Demand Savings Associated with LED Blitz Lighting Measures Category of Product LED A Lamp 8W LED A Lamp 12W LED MR16 7W LED GU10 5W LED BR30 11W LED BR30 13W LED BR40 11W LED BR40 18W LED PAR20...
AI summary Table 20 evaluates the gross energy and peak demand savings from LED Blitz Lighting Measures across various product categories. It details the number of units installed, energy savings in GWh, line loss factors, and peak demand savings in MW for different LED lighting products.
Table 21: Evaluation of Gross Energy and Peak Demand Savings Associated with LED Blitz Non-lighting Measures Category of Product Vending Machine Misers Faucet Aerators Pre-Spray Valves Total for All LED Blitz Measures Number of Units 60 1...
AI summary Table 21 evaluates the energy and peak demand savings from non-lighting measures under the LED Blitz program. It details the number of units installed, energy savings, and peak demand savings across categories like vending machine misers, faucet aerators, and pre-spray valves. The total gross energy savings at the generator level is 0.653 GWh, with peak demand savings of 0.135 MW.
5.4.1 Interactive Effects for BES Lighting Measures Installing new efficient lighting products to replace old lighting fixtures inside a conditioned space brings out an increase in the heating load during winter, as less waste heat from li...
AI summary Replacing old lighting fixtures with efficient ones increases winter heating loads but decreases summer cooling loads. The weighted interactive effect coefficient of -5.4% was calculated based on an ADS study from 1992 and data from 44 on-site visits for the 2014 BES lighting evaluation.
Table 23: Average Interactive Effect Factors for Lighting Products Category of Product % Indoor % Outdoor Interactive Effect Coefficient Exit Signs 100% 0% (100% × -5.4%) + (0% × 0%) = -5.4% All Other Lighting Products 97% 3% (97% × -5.4%)...
AI summary Table 23 presents average interactive effect factors for lighting products, specifically exit signs and other lighting products, with calculations based on indoor and outdoor percentages and interactive effect coefficients.
5.4.2 Interactive Effects for BES Non-lighting Measures Interactive effects occur for hot water tank wraps, pipe insulation, hot water heat pumps and vending machine misers. Heat released by non-insulated hot water tanks and pipes located...
AI summary The text discusses interactive effects for BES non-lighting measures such as hot water tank wraps, pipe insulation, hot water heat pumps, and vending machine misers. These measures reduce heat dissipation, leading to increased heating loads and decreased cooling loads. Interactive effects are calculated using heating and cooling degree-days for the Halifax region, with specific percentages applied for heating and cooling seasons.
Table 24: Interactive Effect Factor for Hot Water Tank Wraps, Pipe Insulation, Hot Water Heat Pumps, and Vending Machine Misers Parameters % of Facilities Interactive Effects During Heating Period Interactive Effects During Cooling Period...
AI summary Table 24 presents the interactive effect factors for various energy efficiency measures, including hot water tank wraps, pipe insulation, heat pumps, and vending machine misers, across different heating and cooling scenarios. The weighted interactive effect factors are calculated as -8.7% during the heating period and +4.7% during the cooling period.
5.4.4 Interactive Effects for LED Blitz For lighting measures implemented through LED Blitz, the Evaluator applied an interactive effect factor of -5.4 percent. This value was derived from the BES lighting measures installed in interior sp...
AI summary The Evaluator applied an interactive effect factor of -5.4 percent for LED Blitz lighting measures, derived from BES lighting measures in interior spaces. A -8.7 percent factor was applied to vending machine misers based on BES non-lighting measures, while other non-lighting measures like faucet aerators had negligible interactive effects.
Internal Spillover The annual participant survey was used to assess internal spillover, which can occur when participants purchase and install additional energy efficiency measures following their previous participation in the program beca...
AI summary The document discusses internal spillover, referring to when program participants install additional energy efficiency measures after previous participation. A 0.3% internal spillover factor was established for 2014, with similar levels recorded in previous years.
5.6 Net Savings The net savings for the program were estimated using the interactive effect factors and the NTGR mentioned above. The following equation was used to calculate the program net savings. Net Savings = Gross Evaluation Savings...
AI summary The net savings for the program were calculated using an equation that incorporates gross evaluation savings, interactive effect factors, and the net-to-gross ratio (NTGR). This method was applied to assess peak demand and energy savings for BES lighting, non-lighting measures, RP&C common areas, and the LED Blitz pilot.
5.6.1 Net Savings for BES Lighting Measures The table below shows the net savings established for BES lighting measures. The total net energy and peak demand savings amount to 10.274 GWh and 1.834 MW at the meter respectively and 10.993 GW...
AI summary This section presents the net savings for BES lighting measures, including total energy savings of 10.274 GWh and peak demand savings of 1.834 MW at the meter, and 10.993 GWh and 1.963 MW at the generator.
Table 25: Evaluation of Net Energy and Peak Demand Savings Associated with BES Lighting Measures LED s Fluoresc ent T8 , Total Category of Product Reballast (linear) Other Reballast Other CFLs Custom Т5 Exit Signs Metal Halide Others Energ...
AI summary Table 25 presents an evaluation of net energy and peak demand savings associated with BES lighting measures, including LED, fluorescent, and other lighting technologies. The table provides data on gross and net energy savings, interactive effect factors, NTGR, line loss factors, and peak demand savings at both the meter and generator levels.
The following table compares the energy and peak demand savings established by this evaluation and those calculated in the 2014 tracking system.
AI summary The text references a comparison table between energy and peak demand savings from a recent evaluation and those calculated in the 2014 tracking system, indicating a focus on energy efficiency program performance tracking.
Table 26: Comparison of Tracked and Evaluated Savings Associated with BES Lighting Measures at the Generator Initial Gross Savings Adjusted Gross Savings Gross with Interactive Effects NTGR Net Savings Energy Savings Tracked Savings from E...
AI summary Table 26 compares tracked and evaluated savings from BES lighting measures. Evaluated net energy savings are 4% higher than tracked savings due to reduced interactive effects and a revised NTGR value, though the increase is limited by a revision to the ballast factor.
5.6.2 Net Savings for BES Non-lighting Measures [Table 27](#page-132-0) presents the net energy and peak demand savings associated with BES non-lighting measures. The total net energy and peak demand savings amount to 1.131 GWh and 0.403 M...
AI summary Table 27 outlines the net energy and peak demand savings from BES non-lighting measures, showing 1.131 GWh and 0.403 MW at the meter, and 1.226 GWh and 0.437 MW at the generator.
Table 27: Evaluation of Net Energy and Peak Demand Savings Associated with BES Non-lighting Measures Category of Product Heat Pumps Hot Water Tank Wraps Pipe Insulation Vending Machine Misers Hot Water Heat Pumps Total Energy Savings Total...
AI summary Table 27 evaluates the net energy and peak demand savings from non-lighting measures under the Building Energy Standards (BES). It shows energy savings across categories such as heat pumps and pipe insulation, with adjustments for interactive effects and line loss factors, resulting in total net energy and peak demand savings at both the meter and generator levels.
The following table compares the energy and peak demand savings established by this evaluation and those calculated in the 2014 tracking system.
AI summary The text presents a table comparing energy and peak demand savings from this evaluation with those from the 2014 tracking system, indicating a focus on energy efficiency and demand-side management metrics.
Table 28: Comparison of Tracked and Evaluated Savings Associated with BES Non-lighting Measures at the Generator Initial Gross Savings Adjusted Gross Savings Gross Savings with Interactive Effects NTGR Net Savings Energy Savings Tracked Sa...
AI summary Table 28 compares tracked and evaluated savings from BES non-lighting measures. Evaluated energy savings are 23% higher than tracked savings, while evaluated peak demand savings are 1% lower. This highlights discrepancies between actual and reported savings from energy efficiency initiatives.
Table 29: Evaluation of Net Energy and Peak Demand Savings Associated with RP&C Common Areas (CFLs) Category of Product 13-Watt CFL 14-Watt CFL 23-Watt CFL 14-Watt Dim. CFL 16-Watt Dim. CFL 3-Watt LED Chandelier 10-Watt LED A-lamp 9-Watt P...
AI summary Table 29 evaluates the net energy and peak demand savings associated with the use of Compact Fluorescent Lamps (CFLs) and Light Emitting Diodes (LEDs) in common areas of rental properties and condos. The table includes energy savings at the meter and generator, as well as peak demand savings, factoring in interactive effects and line loss.
Table 30: Evaluation of Net Energy and Peak Demand Savings Associated with RP&C Common Areas (Other Products) Category of Product 12-Watt BR30 7-Watt MR16 LED Exit Lights Low-flow Faucet Aerator Low-flow Showerhead Low-flow Showerwand Pipe...
AI summary Table 30 evaluates the net energy and peak demand savings associated with RP&C Common Areas (Other Products). It presents data on energy savings in GWh and peak demand savings in MW for various products, including LED exit lights, low-flow faucets, and pipe insulation. The table includes factors like Interactive Effect Factor, NTGR, and Line Loss Factor to calculate total net savings at the meter and generator.
Table 31: Comparison of Tracked and Evaluated Savings Associated with RP&C Common Area Measures at the Generator Initial Gross Savings Installed Gross Savings Installed Gross Savings with Interactive Effects NTGR Net Savings Energy Savings...
AI summary Table 31 compares tracked and evaluated savings from RP&C common area measures, focusing on energy and peak demand savings. The table includes metrics like initial gross savings, net-to-gross ratio (NTGR), and net savings, highlighting the impact of LED Blitz initiatives on energy efficiency.
[Table 32](#page-137-0) and [Table 33](#page-138-0) show the net savings established for LED Blitz lighting and non-lighting measures respectively. The total net energy and peak demand savings for all the measures implemented through LED B...
AI summary The text presents net energy and peak demand savings from LED Blitz lighting and non-lighting measures. Total savings are reported at both the meter and generator levels, highlighting the impact of these measures on energy efficiency.
Table 32: Evaluation of Net Energy and Peak Demand Savings Associated with LED Blitz (Lighting Measures) Category of Product LED A Lamp 8 W LED A Lamp 12 W LED MR16 10 W LED GU10 5 W LED BR30 11 W LED BR30 13 W LED BR40 11 W LED BR40 18 W...
AI summary Table 32 evaluates the net energy and peak demand savings associated with the LED Blitz (Lighting Measures) for various LED products. The table includes energy savings at the meter and generator, peak demand savings, and factors such as interactive effects, NTGR, and line loss.
Table 33: Evaluation of Net Energy and Peak Demand Savings Associated with LED Blitz (Non-lighting Measures) Category of Product Vending Machine Misers Faucet Aerators Pre-Spray Valves Total for All Measures Energy Savings Total Gross Ener...
AI summary Table 33 evaluates the net energy and peak demand savings from non-lighting measures in the LED Blitz program, including vending machine misers, faucet aerators, and pre-spray valves. It provides figures for gross and net energy savings, interactive effect factors, NTGR, line loss factors, and peak demand savings at both the meter and generator levels.
Table 34: Comparison of Tracked and Evaluated Savings Associated with LED Blitz at the Generator Initial Gross Savings Installed Gross Savings Installed Gross Savings with Interactive Effects NTGR Net Savings Energy Savings Tracked Savings...
AI summary Table 34 compares tracked and evaluated savings from the LED Blitz pilot program. Evaluated savings are 22% and 23% higher than tracked savings for energy and peak demand, respectively. The main factor explaining this difference is not specified in the text.
6 OVERALL BES RESULTS This section summarizes the overall results of the impact evaluation for BES. When combining the net savings generated from the measures implemented through BES, including LED Blitz, RP&C Common Areas and LED Blitz, t...
AI summary The section summarizes the overall results of the Building Energy Standards (BES) impact evaluation. Combined net savings from implemented measures, including LED Blitz and RP&C Common Areas, amount to 13.175 GWh in energy and 2.570 MW in peak demand savings.
Table 35: Overall Comparison of Tracked and Evaluated Savings at the Generator for BES Initial Gross Savings Installed Gross Savings Installed Gross Savings with Interactive Effects NTGR Net Savings Energy Savings Tracked Savings from ENSC...
AI summary Table 35 compares tracked and evaluated savings at the generator for Building Energy Standards (BES). It shows energy and peak demand savings from the Energy Efficiency Program (ENS) and the evaluation results, including the Net-to-Gross Ratio (NTGR) for each category.
Sections Recommendations 8 Plan on the complete and ultimate removal of CFLs and fluorescent T8 tubes from BES. BES results showed that savings associated with florescent T8 decreased by 53 percent in 2014. So, the Evaluator recommends tha...
AI summary The document discusses the removal of CFLs and fluorescent T8 tubes from BES due to declining savings and the need to transition to more efficient technologies like LEDs. It also recommends removing the 'BES Measure Occupancy Sensor Savings' field from tracking reports as savings are now calculated through reduced operating hours.
INTRODUCTION Hello, I am with CRA, Corporate Research Associates, a Halifax-based survey research company. We are performing an evaluation of energy efficiency services and programs provided by Efficiency Nova Scotia Corporation. Our recor...
AI summary CRA, a Halifax-based survey research company, is evaluating Efficiency Nova Scotia Corporation's Business Energy Solutions Program. They are seeking participation information from individuals or firms that recently engaged with the program to help improve it.
Barriers (Series B) - B1. Were there any challenges or barriers that your company or organization faced in implementing the energy efficiency measures provided through the Business Energy Solutions program? - 1. Yes - 2. No (GO TO R1) - 98...
AI summary The document presents a series of questions regarding barriers faced in implementing energy efficiency measures through the Business Energy Solutions program. Respondents are asked to identify the most and second most important challenges, including lack of information, insufficient incentives, and technical knowledge issues.
Spillover (Series SP) - SP1. Now I'd like you to think of the time since you participated in the Business Energy Solutions program. Has your company purchased and installed any additional energy-efficient products on its own for this facil...
AI summary This section of the proceeding contains a series of questions aimed at assessing the impact of the Business Energy Solutions program on participants. It inquires about the installation of additional energy-efficient products post-participation and whether any other financing or incentives were received.
[ IF YES ] - SP4i_1.What are the other energy-efficiency products that you have installed since participating in the Business Energy Solutions Program? [RECORD VERBATIM. RECORD DIFFERENT PRODUCTS SEPARATELY. PROBE FOR A SPECIFIC ANSWER. DO...
AI summary The text outlines survey questions related to the Business Energy Solutions Program, asking participants about additional energy-efficiency products installed and the influence of the program on their decisions. The questions include specific instructions for recording responses and handling missing or refused answers.
Firmographics (Series F) These final questions are asked for statistical purposes only. The information collected is strictly confidential. - F1. What is the main activity of the facility where the energy efficiency improvements were imple...
AI summary The text presents a statistical question from a regulatory proceeding, asking about the main activity of a facility where energy efficiency improvements were implemented under the Business Energy Solutions Program. The question is part of a confidential data collection process.
F1. What is the main activity of the facility where the energy efficiency improvements were implemented under the Business Energy Solutions Program? Business Type 2012 2013 2014 Sample Size 76 61 62 Mercantile-Retail – Enclosed mall or str...
AI summary The Business Energy Solutions Program has implemented energy efficiency improvements across various facility types, with the largest share in 2012 being mercantile-retail (other than mall) at 16%, followed by automotive repair at 9%, and others at 8%. The data shows changes in distribution across years.
F2. Approximately how many full-time equivalent workers are employed at this facility? Full-time Employees 2012 2013 2014 Sample Size 76 61 62 Fewer than 5 53% 61% 44% 5 to 9 21% 18% 19% 10 to 19 18% 13% 16% 20 to 49 4% 3% 6% 50 to 99 1% 3...
AI summary The text presents data on the number of full-time equivalent workers at a facility from 2012 to 2014, along with a question about estimating the operating hours of a building where energy efficiency improvements were implemented.
INTRODUCTION Hello, I am with CRA (Corporate Research Associates), and we are performing an evaluation of energy efficiency services provided by Efficiency Nova Scotia Corporation. Our records indicate that you or your firm recently partic...
AI summary CRA is conducting an evaluation of Efficiency Nova Scotia Corporation's Business Energy Solutions Program and is seeking input from participants. The survey aims to assess program effectiveness and identify areas for improvement.
Satisfaction (Series S) - S1. How did your company first learn of the programs offered by Efficiency Nova Scotia? [ DO NOT PROVIDE RESPONSE CATEGORIES]. [CODE AS MANY AS APPLICABLE ]. - 1. Media advertising - 2. Someone at Efficiency Nova...
AI summary The text outlines survey questions related to customer satisfaction with Efficiency Nova Scotia programs. It asks how companies learned about the programs, whether they had direct contact with Efficiency Nova Scotia, and their satisfaction with various factors such as technical expertise and program value.
FR2a. installed through the program? purchased and installed exactly the same quantity of energy-efficient products that you Response 98 Don't Know 99 Refused FR2b. purchased and installed standard products instead of energy-efficient prod...
AI summary The text presents a series of questions and responses related to the installation of energy-efficient products through a program. Respondents are asked about whether they installed products through the program, purchased standard products instead, or installed products at a later date. The responses include categories such as 'Don't Know' and 'Refused'.
VOLUNTEERED - 7. (Never) - 98. (Don't Know) - 99. (Refused) - FR3. Efficiency Nova Scotia conducted an initial assessment at no cost in your facility and offered an incentive towards the total project cost. If your company had not received...
AI summary This section of the document asks respondents about their willingness to pay for energy efficiency projects without incentives, using a scale from 0 to 10. It is part of a survey conducted by Efficiency Nova Scotia to assess the impact of their programs.
FR4. Next, I'm going to ask you to rate the importance of the program as well as other factors that might have influenced your decision to install the energy-efficient products. Please answer on a scale of 0 to 10, where 0 means "Not at al...
AI summary The text asks respondents to rate the importance of the program and other factors influencing their decision to install energy-efficient products on a scale from 0 to 10, with specific instructions to avoid providing a range.
Factor (READ AND RANDOMIZE) Responses a. Efficiency Nova Scotia Financial Assistance Response 98 Don't Know 99 Refused b. Information received during the initial contact by the program representative. Response 98 Don't Know 99 Refused c. E...
AI summary The text presents a series of factors related to Efficiency Nova Scotia financial assistance and industry practices, with responses indicating a lack of knowledge or refusal to answer. It includes questions about program representation, initial assessments, material recycling, and industry standards.
- F1. What is the main activity of the facility where the energy efficiency improvements were implemented under the program? [ DO NOT READ—BUT CONFIRM WITH RESPONDENT THAT THE CATEGORY YOU CHOOSE IS CORRECT ] - 1. (Education) - 2. (Food Sa...
AI summary The text presents a question regarding the main activity of a facility where energy efficiency improvements were implemented under a program. It lists various categories of activities, including education, food sales, health care, and office, among others.
S2. Did your company have any direct contact with any Efficiency Nova Scotia employees or did you only work with a third-party contractor or service delivery agent? Contact with ENSC 2012 2013 2014 Sample Size 87 184 129 Directly with ENSC...
AI summary The response to S2 indicates that the company had varying levels of direct contact with Efficiency Nova Scotia employees over the years 2012 to 2014, with a notable increase in direct contact in 2014. The data also shows a shift from using third-party contractors to direct engagement with ENSC.
\ \ Source: 2012 C-Sat Commercial Study \ \ \ Source: 2013 annual and 2013 quarterly surveys \ \ Source: 2012 C-Sat Commercial Study \ \ \ Source: 2013 annual and 2013 quarterly surveys. Due to a programming error, nine respondents did not...
AI summary The document includes survey data from 2012 and 2013 regarding customer satisfaction with Efficiency Nova Scotia. It references a programming error affecting nine respondents and includes a question about satisfaction with various factors related to Efficiency Nova Scotia.
- S5. Now, using the same 10 point scale, how satisfied are you with Efficiency Nova Scotia's overall performance in working with your business? Satisfaction with Overall 20 12 201 13 20 014 Performance Sample Size Satisfied Sample Size Sa...
AI summary The text presents survey results evaluating Efficiency Nova Scotia's (ENSC) performance in working with businesses. Key metrics include satisfaction levels with ENSC's technical expertise, responsiveness, and the time taken between audits and project proposals, with varying satisfaction scores across different aspects of the program.
S28. Based on your company's experience working with Efficiency Nova Scotia and its third-party contractors, would you definitely, probably, probably not, or definitely not participate in other programs offered by Efficiency Nova Scotia?
AI summary The question asks about the likelihood of participation in other programs offered by Efficiency Nova Scotia based on the company's experience working with Efficiency Nova Scotia and its third-party contractors.
Would Participate in Other ENSC Programs 2012 2013 2014 Sample Size 85 198 129 Definitely 72% 69% 81% Probably 27% 31% 19% Probably not 1% 1% - Definitely not - - - \ &# x27;Don't know'/'Refused' removed from calculation
AI summary The table shows participation rates in other ENSC programs across 2012, 2013, and 2014. The sample sizes and percentages of participants who would definitely, probably, probably not, or definitely not participate are provided, with some missing data for certain years.
Would Recommend BES to Other Businesses/Companies 2012 2013 2014 Sample Size 86 199 129 Definitely 77% 80% 88% Probably 22% 19% 12% Probably not 1% 1% - Definitely not - - - \ &# x27;Don't know'/'Refused' removed from calculation
AI summary The table shows the percentage of respondents who would recommend Building Energy Services (BES) to other businesses from 2012 to 2014, with increasing percentages of 'Definitely' recommendations over time and decreasing percentages of 'Probably' recommendations.
S30. How satisfied were you overall with the service provided by your third-party contractor on managing the process of securing a payment from Efficiency Nova Scotia? Were you... Satisfaction with Overall 20 )12 20 13 2 2014 Performance S...
AI summary The survey results indicate high satisfaction levels (97% to 100%) with the service provided by third-party contractors in managing the process of securing payments from Efficiency Nova Scotia.
BES Elements 2012 2013 2014 Average rating: 0 is "Not at all important", 10 is "Extremely important" Sample Size Mean Score Sample Size Mean Score Sample Size Mean Score ENSC financial assistance 76 9.3 137 9.1 129 9.1 ENSC-funded initial...
AI summary The table presents survey data on the importance of various Building Energy Services (BES) elements from 2012 to 2014. It includes ratings and sample sizes for items such as ENSC financial assistance, ENSC-funded assessments, and the importance of energy efficiency codes. Ratings are based on a scale from 0 to 10, with higher scores indicating greater perceived importance.
F1. What is the main activity of the facility where the energy efficiency improvements were implemented under the program? Business Type 2012 2013 2014 Sample Size 76 199 129 Office 9% 5% 14% Mercantile-Retail – Enclosed mall or strip mall...
AI summary The document provides a table showing the distribution of business types in different years (2012, 2013, and 2014) where energy efficiency improvements were implemented under a program. It includes percentages for various categories such as office, retail, service, and others.
APPENDIX VIII INTERNAL SPILLOVER METHODOLOGY (BES) Internal spillover was measured using a participant survey. Participants were asked whether following their participation in the program, they bought and implemented any additional energy...
AI summary Internal spillover was measured through a participant survey to determine if program participants implemented additional energy efficiency measures outside of rebates. The level of influence of the program on these additional measures was quantified and used to calculate the portion of savings attributable to the program.
FR2a. If your company had not participated in RP&C, what is the likelihood that you would have installed exactly the same energy-efficient products that you installed through RP&C? (Scale 0 to 10) FR2a = Answer x 10% FR2b. If your company...
AI summary The document outlines a scoring methodology used to assess free-ridership in a program, using responses to questions about energy-efficient product installation and participation in the RP&C program. It includes formulas to calculate scores based on participant responses.
APPENDIX X CALCULATION EXAMPLE This appendix displays a sample calculation to demonstrate the process of revising the energy and peak demand savings associated with BES for 2014. Since the lighting measure category accounted for the bigges...
AI summary This appendix provides a sample calculation to demonstrate the revision of energy and peak demand savings under BES for 2014, focusing on the lighting measure category and the algorithms used for tracked and revised savings calculations, as well as the adjustment ratio.
Energy Savings and Peak Demand Savings The following algorithms include the parameters required to determine the annual energy savings and the annual peak demand savings associated with each lighting measure implemented. $$\begin{aligned}...
AI summary The text provides formulas for calculating annual energy savings and annual peak demand savings associated with lighting measures. The formulas use baseline and new unitary wattage values to compute the savings, with baseline wattage derived from decommissioned fixtures and new wattage calculated using lamp quantity, wattage, and ballast factor.
Where: - > Unitary Wattage represents the wattage values of the lighting fixture for the existing (baseline) measure and the proposed (new) measure. - > Hrs represents the annual hours of operation declared by the participants. - > Qty rep...
AI summary The text defines key terms and metrics used in the analysis of lighting fixture efficiency, including wattage, hours of operation, quantity of fixtures, and components like lamps and ballasts. It provides context for understanding energy use and efficiency improvements in lighting systems.
Calculations of Tracked Savings Each measure's energy and demand savings were calculated based on the information available in the tracking report. Like last year, the existing measure's decommissioned equipment wattage documented in the t...
AI summary The document discusses the calculation of energy and demand savings based on tracked data, using a specific example where 400-watt metal halide fixtures were replaced by LED high bay fixtures. The discrepancy between the measure description and the model number is noted.
Baseline Measure: 400W Metal Halide Parameter Value Source Existing Fixture Qty 30 Tracking Report Number of Lamps per Fixture 1 Tracking Report Decommissioned Equipment Wattage (W) 455 Tracking Report Existing Hours per Week 150 Tracking...
AI summary This table provides a comparison between existing and proposed lighting fixtures, detailing energy and demand savings from replacing 400W metal halide fixtures with 4-lamp T5 HO high bay fixtures. It includes quantities, wattage, hours of operation, and calculated energy savings.
The savings calculations were revised by incorporating two adjustments. The first adjustment was made to the hours of operation by applying the self-declaration ratio. The second adjustment was made to the fixture wattage of the new measur...
AI summary The savings calculations were revised with two adjustments: one based on the self-declaration ratio for hours of operation and another based on the correct wattage of an LED high bay fixture, replacing the previously used T5 HO high bay fixture wattage.
Baseline Measure: 400W Metal Halide Parameter Value Source Existing Fixture Qty 30 Tracking Report Decommissioned Equipment Wattage (W) 455 Tracking Report Hours of Operation (hrs/year) 7,644 Adjusted value by applying the self-declaration...
AI summary The document provides data on energy savings from replacing 400W metal halide fixtures with 150W LED high bay fixtures, including quantities, wattage, and adjusted hours of operation. It also mentions an algorithm for establishing adjustment ratios.
Sampling Methodology A total of 50 visits were conducted for the BES impact evaluation. The sampling plan was developed in September 2014 based on the available tracking sheet. This tracking sheet included 519 completed projects (505 for l...
AI summary A sampling methodology was used to evaluate the impact of BES, with 50 visits conducted based on a tracking sheet of 519 completed projects. Initial distribution by energy savings percentage led to only one non-lighting visit, prompting a revised approach using the square root of savings distribution.
Table 36: Number of On-Site Visits Performed for Lighting and Non-Lighting Measures Measure Type Tracked Gross Savings (MWh) % of Total Tracked Savings Square Root of Tracked Savings % of Total of Square Root of Tracked Savings Actual Samp...
AI summary Table 36 presents the number of on-site visits performed for lighting and non-lighting measures, highlighting that lighting measures account for the majority of tracked energy savings and sample size compared to non-lighting measures.
Table 37: Tracked Gross Energy Savings for Each Lamp Type Implemented 18 Lamp Type LED Т8 Custom Т5 All-Start Retrofit CFL Total Total Savings (MWh) 5,507 2,089 741 282 239 163 9,021 % of Total Savings 61.0% 23.2% 8.2% 3.1% 2.7% 1.8% 100%...
AI summary Table 37 shows the tracked gross energy savings for different lamp types implemented by BES lighting measures. LED and T8 lamps account for 84% of total savings, and the sample selection included projects with at least these two lamp types to ensure a range of savings are represented.
Lighting GENERAL INFORMATION # Project ID Project Name Site Visit Date Company Name Contact Name Contact Phone # Address City Person met during visit Type of facility (i.e. office, school, retail) Notes OCCUPANCY SCHEDULE Days/yr with norm...
AI summary The document contains a table with information about lighting projects, including project IDs, names, site visit dates, company details, and facility types. It also includes an occupancy schedule and a section on heat pump measures, though specific details are not provided in the text.
INTRODUCTION OF NEW CODES AND STANDARDS IN NOVA SCOTIA 2014 DSM EVALUATION EFFICIENCY NOVA SCOTIA CORPORATION Final Report February 26, 2015
AI summary This document introduces new codes and standards in Nova Scotia, focusing on the 2014 DSM evaluation by Efficiency Nova Scotia Corporation. It includes a final report dated February 26, 2015, and contains images related to the evaluation.
Table 2: Products Targeted by Amendment 12b 5 Products Existing MEPS prior to Amendment 12b Reference Standard Incandescent light bulbs (75 watts and 100 watts) No CAN/CSA C862-09 In addition to these products, Nova Scotia decided on its o...
AI summary Nova Scotia has implemented Minimum Energy Performance Standards (MEPS) for incandescent light bulbs and voluntarily enforced MEPS for street lights and an Energy Code for residential and small commercial buildings, making it the first province in Canada to require LED roadway lights.
Table 3: Specific Products Regulation in Nova Scotia Products Existing MEPS prior to Provincial Initiative Reference Standard LED street lights6 No CAN/CSA C653-13 National Energy Code for houses and small buildings – NBC – Revision 2012 –...
AI summary Table 3 outlines specific products regulated in Nova Scotia, including LED street lights and the National Energy Code for buildings. Efficiency Nova Scotia commissioned an evaluation of the impact of new regulations on these products. The evaluation excluded residential boilers and digital television adapters due to lack of data and negligible market size.
Table 4: 2014 Evaluated Energy and Peak Demand Savings at the Generator Products Total Energy Savings at Generator (GWh) Total Peak Demand Savings at Generator (MW) Electric motors 0.686 0.154 General service incandescent reflector lamps 1...
AI summary Table 4 presents energy and peak demand savings at the generator in 2014 from various products and programs. Savings from Codes & Standards (C&S) are attributed to increased minimum efficiency standards, distinct from other Efficiency Nova Scotia (ENSC) components, which focus on product efficiency improvements relative to current baselines.
Table 5: Products Targeted by Amendment 11 12 Products Existing MEPS prior to Amendment 11 Reference Code Electric motors Yes CAN/CSA 390-10 Residential gas boilers Yes CSA P.2-07 Residential oil boilers Yes CSA P.2-07 Dry-type transformer...
AI summary Table 5 lists products targeted by Amendment 11, showing which items have existing MEPS (Minimum Energy Performance Standards) and the reference codes associated with them. Some products, such as standby for electronic products and external power supplies, do not have existing MEPS.
Table 7: Specific Products Regulation in Nova Scotia Products Existing MEPS Prior to Provincial Initiative Reference Standard LED street lights14 No CAN/CSA C653-13 National Energy Code for houses and small building – NBC – Revision 2012 –...
AI summary Table 7 outlines specific products regulated in Nova Scotia, including LED street lights and the National Energy Code for buildings. Efficiency Nova Scotia commissioned an evaluation of energy savings from these regulations, which excluded residential boilers and digital television adapters due to lack of data.
2.1 Objective and Approach of the Impact Evaluation The purpose of the evaluation is to quantify, in terms of energy and peak demand savings, the impact of 11 regulations introduced in the Nova Scotia market for 2014. To this end, three ma...
AI summary The impact evaluation aims to quantify the energy and peak demand savings from 11 regulations introduced in Nova Scotia's market in 2014. The evaluation uses three parameters: market size, the portion of the market affected by the regulations, and unitary savings values.
2.3.1 Contact with Natural Resources Canada NRCan was contacted in October and asked to provide documentation, including market analyses produced for of all the evaluated regulations. For reference purposes, the protocol used by the Econol...
AI summary Natural Resources Canada (NRCan) was contacted in October to provide documentation, including market analyses for evaluated regulations. The protocol used by Econoler and its subcontractor CRA for conducting the interview with NRCan is detailed in Appendix I.
Table 8: Methodology Used to Estimate Market Sizes Method to Estimate Total Shipments to Canada or Atlantic Region Method to Estimate Shipments to Nova Scotia List of Products Industry associations Database for 2014 in units or in dollar a...
AI summary Table 8 outlines the methodologies used to estimate market sizes for various products in Canada and Nova Scotia. It includes methods from industry associations and Statistics Canada's trade database, with specific products like incandescent lamps and LED street lighting having unique approaches.
2.3.3 Interviews with Associations and Regulators From early December to end of January, representatives from associations were instrumental in numerous exchanges by explaining the data, confirming its reliability and indicating how best t...
AI summary Interviews with associations and regulators from early December to the end of January were conducted to explain data, confirm its reliability, and provide insights on its use. Regulators such as NRCan and CSA were interviewed to understand energy savings, market activity, and compliance issues related to LED street lighting and building codes.
2.3.4 Analysis Once all interviews were completed and data was collected, market size estimates were developed. Once the market size for each product category and the portion of the market impacted by the regulations was determined, it was...
AI summary The analysis estimates the impact of new regulations on market size in Nova Scotia, distinguishing savings from C&S (Codes & Standards) and ENSC (Efficiency Nova Scotia) programs. It ensures no overlap between savings from these sources, emphasizing that C&S savings result from increased minimum efficiency standards, while ENSC savings are based on product efficiency improvements.
Table 9: Three-phase Electric Motor Market Size Estimate for Canada and Nova Scotia, 2014 Product Class Shipments to Canada in 2014 Shipments to Nova Scotia in 2014 Three-phase electric motors sized 1 to 5 HP 56,639 1,048 Three-phase elect...
AI summary Table 9 provides an estimate of the market size for three-phase electric motors in Canada and Nova Scotia in 2014, categorizing shipments by motor size. Section 3.1.2 discusses the portion of the market impacted by regulation, though specific details are not included in the provided text.
In the report prepared by Nielsen Engineering, the percentage of NEMA Premium efficiency motor sales is provided for 2003 to 2007. This data comes from a survey of motor manufacturers, dealers and distributors across Canada, and a survey c...
AI summary The report by Nielsen Engineering provides data on NEMA Premium efficiency motor sales from 2003 to 2007, used to estimate noncompliant motor percentages. Compliance rates for motors 1-200 HP are more stringent than for 201-500 HP motors. Province-specific data is lacking, so Canadian compliance rates are applied to Nova Scotia.
Table 10: Initial Estimate of the Portion of the Three-phase Electric Motor Market Impacted by the Regulation Product Class Percentage of Total Shipments to Nova Scotia Affected by the Regulation in 2013 Three-phase electric motors sized 1...
AI summary Table 10 shows the percentage of three-phase electric motors affected by a regulation in Nova Scotia in 2013. The Canadian Standards Association (CSA) confirmed that product compliance is largely unchanged, with only minor variances expected due to production issues.
3.1.3 Unitary Savings Values Amendment 11 provides the unitary savings values for some types of electric motors, as presented in Table 11.
AI summary Amendment 11 introduces unitary savings values for specific types of electric motors, as detailed in Table 11.
Table 11: Unitary Savings Values for Electric Motors 22 Product Class Demand Savings (W/unit) Annual Energy Savings (kWh/unit) 5 horsepower 51 133 15 horsepower 103 325 30 horsepower 175 637 75 horsepower 464 2,161 150 horsepower 565 2,677...
AI summary Table 11 provides unitary savings values for electric motors of various horsepower ratings, detailing demand savings in watts per unit and annual energy savings in kilowatt-hours per unit.
3.1.4 At-meter Energy Savings The Evaluator estimated the impact of the introduction of this regulation in the Nova Scotia market in terms of "at meter" energy savings by using the data collected on unitary savings, the market size of elec...
AI summary The Evaluator estimated 'at meter' energy savings from a new regulation in Nova Scotia by using unitary savings data, market size of electric motors, and noncompliance rates. For 26-100 HP three-phase motors, an average of savings values for 30 HP and 75 HP motors was used. Total estimated savings for 2014 are 0.645 GWh.
Table 12: Energy Savings Associated with the Introduction of the Electric Motors Regulation in the Nova Scotia Market Product Class Shipments to Nova Scotia in 2014 Percentage of Total Shipments to Nova Scotia Affected by the Standard in 2...
AI summary Table 12 outlines the energy savings associated with the introduction of the Electric Motors Regulation in Nova Scotia. It details the shipments of various three-phase electric motors in 2014, the percentage affected by the standard, and the resulting annual energy savings in kWh and GWh.
Table 13: Demand Savings Associated with the Introduction of the Electric Motors Regulation in the Nova Scotia Market Product Class Shipments to Nova Scotia in 2014 Percentage of Total Shipments to Nova Scotia Affected by the Standard in 2...
AI summary Table 13 provides demand savings data for electric motors in Nova Scotia following the introduction of the Electric Motors Regulation. It shows the number of units shipped, percentage affected by the regulation, and corresponding demand savings across various motor sizes.
3.2.1 Market Size Estimate A report commissioned by NRCan and prepared by Navigant Consulting to help prepare the amendment to the regulations targeting general service incandescent reflector lamps provides estimates for Canada's domestic...
AI summary The document discusses a market size estimate for BR and ER lamps in Canada and Nova Scotia, using data from Navigant Consulting and EFC. It notes that BR lamp data was incomplete, so estimates were derived from proportions in earlier studies. ER lamp shipments in Nova Scotia are considered negligible in 2014.
3.2.2 Portion of the Market Impacted by the Regulation In its report, Navigant Consulting does not provide any data regarding the percentage of shipments that would have been affected by Amendment 11 (i.e., the percentage of noncompliant l...
AI summary Navigant Consulting did not provide data on the percentage of noncompliant lamp shipments affected by Amendment 11. CSA estimates only minor variances (2-3%) below required energy efficiency levels due to production issues, with products otherwise considered compliant based on follow-up testing.
3.2.3 Unitary Savings Values When Amendment 11 was published in the Canada Gazette , the Office of Energy Efficiency (OEE) published the unitary savings values for some of the general service incandescent reflector lamps targeted by the re...
AI summary Amendment 11 to regulations targeting general service incandescent reflector lamps included unitary savings values published by the Office of Energy Efficiency in the Canada Gazette , as detailed in Table 16.
Table 16: Unitary Savings Values for General Service Incandescent Reflector Lamps 25 Product Class Demand Savings (W/unit) Annual Energy Savings (kWh/unit) Residential 85 watt BR30 – residential 21 18 75 watt BR38 – residential 21 18 120 w...
AI summary Table 16 presents unitary savings values for general service incandescent reflector lamps in residential and commercial settings, including demand savings in watts per unit and annual energy savings in kilowatt-hours per unit for various lamp types.
3.2.4 At-meter Energy Savings The Econoler team estimates that 0.518 GWh was saved at the meter in Nova Scotia in 2014 as a result of the introduction of the regulation on general service incandescent reflector lamps.
AI summary The Econoler team estimates that 0.518 GWh was saved at the meter in Nova Scotia in 2014 due to the introduction of the regulation on general service incandescent reflector lamps.
Table 17: Energy Savings Associated with the Introduction of the General Service Incandescent Reflector Lamps Regulation in the Nova Scotia Market Product Class Shipments to Nova Scotia in 2014 Percentage of Total Shipments to Nova Scotia...
AI summary Table 17 presents energy savings data from the introduction of the General Service Incandescent Reflector Lamps Regulation in Nova Scotia, showing the impact on shipments and energy savings across residential and commercial sectors. The section '3.2.5 At-meter Peak Demand Savings' suggests a discussion on the reduction in peak demand as a result of the regulation.
The Econoler team estimates that 0.869 MW was saved at the meter in Nova Scotia in 2014 as a result of introducing the regulation for general service incandescent reflector lamps. A diversity factor of 100 percent for residential bulb and...
AI summary The Econoler team estimated that 0.869 MW was saved in Nova Scotia in 2014 due to regulations on general service incandescent reflector lamps. Diversity factors of 100% and 84% were applied to residential and commercial bulb demand savings, respectively, based on the 2014 BER evaluation report.
Table 20: Portion of the Three-phase Dry-type Transformer Market Impacted by the Regulation 29 Product Class Percentage of Total Shipments to Nova Scotia Affected by the Regulation in 2014 Three Phase <750 kVA – 1.2 kV Class 95% Three Phas...
AI summary Table 20 shows that the regulation impacts 95% of shipments for all three categories of three-phase dry-type transformers in Nova Scotia in 2014, indicating a broad market reach.
3.3.3 Unitary Savings Values Navigant's report indicated annual energy savings for compliant versus noncompliant three-phase drytype transformers common to each power class. The unitary savings values are considered conservative since they...
AI summary Navigant's report estimates annual energy savings for compliant versus noncompliant three-phase drytype transformers, assuming conservative unitary savings values. Demand savings are calculated based on energy savings and constant load operation, with assumptions considered conservative due to peak load smoothing and lack of diversity factor data.
Table 21: Unitary Savings Values for Three-phase Dry-type Transformers Product Class Annual Energy Savings (kWh/unit) Demand Savings (W/unit) Three Phase <750 kVA – 1.2 kV Class 4,320 493 Three Phase 500–2500 kVA – >1.2 kV 8,034 917 Three...
AI summary This section discusses energy savings at the meter for three-phase dry-type transformers, providing unitary savings values for different product classes based on annual energy and demand savings.
The Evaluator estimates that the introduced regulation on three-phase dry-type transformers generated 0.633 GWh in energy savings in Nova Scotia in 2014.
AI summary The Evaluator estimates that the introduced regulation on three-phase dry-type transformers generated 0.633 GWh in energy savings in Nova Scotia in 2014.
Table 22: Energy Savings Associated with the Introduction of the Three-phase Dry-type Transformer Regulation in the Nova Scotia Market Product Class Shipments to Nova Scotia in 2014 Percentage of Total Shipments to Nova Scotia Affected by...
AI summary Table 22 outlines the energy savings resulting from the introduction of the Three-phase Dry-type Transformer Regulation in the Nova Scotia market in 2014. It lists the product classes, shipments, percentage affected by the regulation, and the corresponding energy savings in kWh/unit and total incremental energy savings in GWh.
Table 23: Demands Savings Associated with the Introduction of the Three-phase Dry-type Transformer Regulation in the Nova Scotia Market Product Class Shipments to Nova Scotia in 2014 Percentage of Total Shipments to Nova Scotia Affected by...
AI summary Table 23 presents demand savings associated with the introduction of the Three-phase Dry-type Transformer Regulation in the Nova Scotia market. The table outlines product classes, shipments, percentage affected by the standard, demand savings, diversity factor, and total peak demand savings in 2014.
Table 24: Self-contained Commercial Ice Cream-type Freezer Market Size Estimate in Canada and Nova Scotia in 2014 33 Product Class Shipments to Canada in 2014 Shipments to Nova Scotia in 2014 Opaque ice cream-type freezers 87 1 Transparent...
AI summary Table 24 provides an estimate of the market size for self-contained commercial ice cream-type freezers in Canada and Nova Scotia in 2014, showing shipments to Nova Scotia were significantly lower than those to Canada. Section 3.4.2 discusses the portion of the market impacted by the regulation.
In its report, Caneta Research provided the percentage of shipments that would have been affected by Amendment 11 (i.e., the percentage of noncompliant lamp shipments prior to the Regulation that must now be compliant). Based on an intervi...
AI summary Caneta Research reported on the impact of Amendment 11 on noncompliant lamp shipments, noting that minor variances of 2% to 3% below required energy efficiency levels are expected due to production issues. The CSA confirmed that products are otherwise fully compliant based on follow-up testing.
Table 26: Unitary Savings Values for Commercial Ice Cream-type Freezers 35 Product Class Demand Savings (W/unit) Annual Energy Savings (kWh/unit) Opaque ice cream-type freezers 144 576 Transparent ice cream-type freezers 443 2,215 3.4.4 At...
AI summary Table 26 presents unitary savings values for commercial ice cream-type freezers, distinguishing between opaque and transparent models. The section 'At-meter Energy Savings' introduces a discussion on energy savings at the meter level, though no detailed analysis is provided in the excerpt.
3.4.5 At-meter Peak Demand Savings The Econoler team estimates that 0.618 MW was saved at the meter in Nova Scotia in 2014 as a result of introducing the regulation on commercial ice cream-type freezers. A diversity factor of 100 percent i...
AI summary The Econoler team estimates that 0.618 MW was saved at the meter in Nova Scotia in 2014 due to the regulation of commercial ice cream-type freezers, assuming a 100% diversity factor as these freezers operate permanently.
3.5.1 Market Size Estimate In 2008, Caneta Research produced a report for NRCan, entitled Market, Benchmark and Technical Analysis for Large Air Conditioners and Heat Pumps for Future Regulation Amendment . 36 In this report, Caneta Resear...
AI summary The document discusses a market size estimate for large air conditioners and heat pumps in Nova Scotia in 2014, based on data from Caneta Research and HRAI Canada. The Canadian market decreased by 75% from 2006 levels, and Nova Scotia's market size was estimated using its demographic weight within Atlantic Canada.
3.5.2 Portion of the Market Impacted by the Regulation In its report, Caneta Research mentions that "at the time of the study [2008, ed.], of equipment sold in Canada, 90% were minimum-efficiency, 7% were mid-efficiency and only 3% were hi...
AI summary Caneta Research's 2008 study indicates that 90% of equipment sold in Canada was minimum-efficiency, with only 3% being high-efficiency. The report assumes a 90% noncompliance rate for equipment targeted by the regulation in Nova Scotia, due to a lack of detailed noncompliance data.
In Amendment 11, NRCan has specified the average unitary savings values for categories of large air conditioners and heat pumps, as presented in the following table.
AI summary Amendment 11 outlines average unitary savings values for large air conditioners and heat pumps as specified by NRCan.
Table 31: Large Air Conditioner and Heat Pump Unitary Savings Values 42 Product Class Demand Savings (W/unit) Annual Energy Savings (kWh/unit) Medium air conditioners (≥ 19.0 kW and < 39.6 kW (≥ 65,000 Btu/h and < 135,000 Btu/h)) 652 717 L...
AI summary Table 31 presents energy savings values for large air conditioners and heat pumps based on product class, including demand savings and annual energy savings per unit. These data are sourced from a 2008 Caneta Research report.
3.5.4 At-meter Energy Savings Based on these unitary savings values, the large air conditioner and heat pump market size estimates for Nova Scotia and the estimates of total shipments to Nova Scotia affected by the regulation in 2013, the...
AI summary The Evaluator estimates that the introduction of regulations on large air conditioners and heat pumps in Nova Scotia has resulted in energy savings of 0.308 GWh at the meter, based on market size estimates and unitary savings values.
Table 32: Energy Savings Associated with the Introduction of the Large Air Conditioners and Heat Pumps Regulation in the Nova Scotia Market Product Class Shipments to Nova Scotia in 2014 Percentage of Total Shipments to Nova Scotia Affecte...
AI summary Table 32 presents energy savings associated with the introduction of the Large Air Conditioners and Heat Pumps Regulation in Nova Scotia. The table provides data on shipments, percentage of shipments affected by the regulation, annual energy savings per unit, and total incremental energy savings for different product classes in 2014.
The Econoler team estimates that 0.160 MW was saved at the meter in Nova Scotia in 2014 as a result of introducing the regulation on large air conditioners and heat pumps. A diversity factor of 0 percent was applied to air conditioners sin...
AI summary The Econoler team estimates that 0.160 MW was saved in Nova Scotia in 2014 due to regulations on large air conditioners and heat pumps. Diversity factors of 0% and 98% were applied to air conditioners and heat pumps, respectively, based on evaluations and on-site visits.
Table 33: Peak Demand Savings Associated with the Introduction of the Large Air Conditioners and Heat Pumps Regulation in the Nova Scotia Market Product Class Shipments to Nova Scotia in 2014 Percentage of Total Shipments to Nova Scotia Af...
AI summary Table 33 outlines peak demand savings associated with the introduction of the Large Air Conditioners and Heat Pumps Regulation in Nova Scotia. The table shows the impact of the regulation on various product classes, including shipments, percentage of shipments affected, demand savings, and total peak demand savings. The data indicates minimal savings in 2014, with only 0.157 MW of total peak demand savings.
Table 34: Single Package Vertical Air Conditioner and Heat Pump (SPVAC and SPVHP) Market Size Estimate for Canada, Atlantic Canada and Nova Scotia, 2014 47 Product Class Shipments to Canada in 2014 Shipments to Atlantic Canada in 2014 Ship...
AI summary Table 34 provides an estimate of the market size for Single Package Vertical Air Conditioner and Heat Pump (SPVAC and SPVHP) shipments to Canada, Atlantic Canada, and Nova Scotia in 2014. Section 3.6.2 discusses the portion of the market impacted by the regulation.
In Amendment 11, NRCan has specified the average unitary savings values for categories of large air conditioners and heat pumps, as presented in the table below.
AI summary Amendment 11 specifies average unitary savings values for large air conditioners and heat pumps, as outlined in a table.
Table 36: Single Package Vertical Air Conditioner and Heat Pump (SPVAC and SPVHP) Unitary Savings Values 49 Product Class Demand Savings (W/unit) Annual Energy Savings (kWh/unit) SPVAC (< 19.0 kW, < 65,000 Btu/h) 652 717 SPVHP (< 19.0 kW,...
AI summary Table 36 presents energy savings values for Single Package Vertical Air Conditioner and Heat Pump units, including demand and annual energy savings for different product classes. The data is sourced from a 2008 Caneta Research report.
3.6.4 At-meter Energy Savings Based on these unitary savings values, the market size estimates for large air conditioners and heat pumps in Nova Scotia and the estimates of total shipments to Nova Scotia affected by the regulation in 2014,...
AI summary The Evaluator estimates that the introduction of regulations on large air conditioners and heat pumps in Nova Scotia has resulted in energy savings of 0.006 GWh at the meter, based on market size estimates and shipment data from 2014.
Table 37: Energy Savings Associated with the Introduction of the Single Package Vertical Air Conditioner and Heat Pump (SPVAC and SPVHP) Regulation in the Nova Scotia Market Product Class Shipments to Nova Scotia in 2014 Percentage of Tota...
AI summary Table 37 provides data on energy savings associated with the introduction of the Single Package Vertical Air Conditioner and Heat Pump regulation in Nova Scotia. The table includes product class, shipments, percentage of shipments affected by the regulation, annual energy savings, and total incremental energy savings for 2014.
Table 38: Peak Demand Savings Associated with the Introduction of the Single Package Vertical Air Conditioner and Heat Pump (SPVAC and SPVHP) Regulation in the Nova Scotia Market Product Class Shipments to Nova Scotia in 2014 Percentage of...
AI summary Table 38 provides data on peak demand savings associated with the introduction of the Single Package Vertical Air Conditioner and Heat Pump (SPVAC and SPVHP) Regulation in the Nova Scotia market. The table includes information on shipments, percentage of shipments affected by the regulation, demand savings per unit, diversity factor, and total peak demand savings for 2014.
3.7.1 Market Size Estimate The initial market size estimate for these products was based on a study conducted by Ecos. Using different sources, such as the 2008 Consumer Electronics Market (CEM) Trends and Forecast and Navigant Consulting'...
AI summary The market size estimate for consumer electronics products in Nova Scotia is based on a study by Ecos using data from various sources, including Statistics Canada's Survey of Household Spending, to determine national and provincial shipment trends from 2002 to 2007.
Table 39: Standby Power Product Market Size Estimates for Canada and Nova Scotia, 2014 53 Product Class Shipments to Canada in 2014 Shipments to Nova Scotia in 2014 Integrated stereo 364,000 23,740 Portable audio 107,408 7,005 Televisions...
AI summary Table 39 provides estimates of standby power product shipments to Canada and Nova Scotia in 2014, including categories such as integrated stereo, portable audio, televisions, and video players.
3.7.4 At-meter Energy Savings The Evaluator estimates that the introduction of new MEPS for standby power products generated 2.933 GWh in total savings in Nova Scotia for 2014.
AI summary The Evaluator estimates that the introduction of new MEPS for standby power products generated 2.933 GWh in total energy savings in Nova Scotia for 2014.
Table 42: Energy Savings Associated with the Introduction of the Standby Power Products Regulation in the Nova Scotia Market Product Class Shipments to Nova Scotia in 2014 Percentage of Total Shipments to Nova Scotia Affected by the Regula...
AI summary Table 42 outlines the energy savings achieved in Nova Scotia following the introduction of the Standby Power Products Regulation, focusing on various product classes and their impact on energy consumption. The table highlights the number of units shipped, the percentage affected by the regulation, and the resulting energy savings in 2014.
3.8.3 Unitary Savings Values The table below presents the unitary savings values provided in Ecos' spreadsheet.
AI summary This section discusses unitary savings values provided in Ecos' spreadsheet, which is relevant to energy efficiency programs and customer-related initiatives.
Table 45: Unitary Savings Values for Products Sold with an External Power Supply62 Product Class Annual Energy Savings (kWh/unit) <1 watts 5.97 1-5 watts 0.01 5-10 watts 7.99 11-20 watts 0.51 21-50 watts 3.10 51-100 watts 4.51 > 100 watts...
AI summary Table 45 presents unitary savings values for products sold with an external power supply, categorized by wattage ranges. The data shows varying annual energy savings in kWh per unit, indicating the energy efficiency impact of different product classes.
3.8.4 At-meter Energy Savings The Evaluator estimates that the introduced regulation on external power supplies generated 2.918 GWh in energy savings in Nova Scotia for 2014.
AI summary The Evaluator estimates that the introduced regulation on external power supplies generated 2.918 GWh in energy savings in Nova Scotia for 2014.
Table 46: Energy Savings Associated with the Introduction of the External Power Supplies Regulation in the Nova Scotia Market Product Class Shipments to Nova Scotia in 2014 Percentage of Total Shipments to Nova Scotia Affected by the Regul...
AI summary Table 46 presents energy savings associated with the introduction of the External Power Supplies Regulation in the Nova Scotia market, showing energy savings by product class and total incremental energy savings for 2014. Section 3.8.5 discusses at-meter peak demand savings.
3.9.1 Product Description Incandescent lamps have been commonly used for lighting applications for over 100 years. The design and energy utilization has remained relatively unchanged. Incandescent lamps are very inefficient converters of e...
AI summary Incandescent lamps have been widely used for over a century but are inefficient, converting most energy to heat. Despite available alternatives, their lighting characteristics and costs did not provide enough incentive for consumers to switch until the late 2000s.
3.9.2 Regulation Description Initially, Amendment 10 to the Regulations was developed to enable a phased-in introduction of lighting standards commencing on January 1, 2012. The regulation is intended to encourage the use of higher-efficie...
AI summary Amendment 10 to the Regulations aimed to phase in lighting standards starting in 2012 to improve efficiency and reduce reliance on incandescent bulbs. Amendment 12 delayed the implementation to 2014 to allow more time for public communication, technological advancements, and addressing concerns related to CFLs.
3.9.4 Portion of the Market Impacted by the Regulation ICF analysis of baseline performance was based on product availability and assumed purchasing and utilization levels on a household or commercial establishment basis. The full analysis...
AI summary The ICF analysis estimated energy savings from lighting standards, but amendments in 12B reduced projected savings. The original 2008 standard aimed for a 30% efficiency increase, while the amended standard allows for slightly less efficient bulbs, resulting in at least 28% energy savings compared to traditional incandescent bulbs. The analysis assumes average household usage and product availability.
3.9.5 At-meter Energy Savings The Evaluator suggests the impact on 2014 would be less than 4 percent. This is based on the following assessments: - › ICF noted that 3.6 bulbs should be replaced, based on an average of 26.4 bulbs/Canadian h...
AI summary The Evaluator estimates that at-meter energy savings from replacing light bulbs in residential households would result in a 3.8% reduction in energy consumption, equivalent to 16.528 GWh in Nova Scotia. This is based on data from ICF and NRCan, but commercial sector savings could not be estimated due to insufficient information.
Table 48: Energy Savings Associated with the Introduction of Incandescent Bulbs Standards in the Nova Scotia Market Product Class Total Incremental Energy Savings at Meter for 2014 (GWh) Incandescent bulbs (75 - 100W) 16.528 The Evaluator...
AI summary Table 48 shows energy savings from incandescent bulb standards in Nova Scotia, with 16.528 GWh saved in 2014. The Evaluator confirmed no overlap with the Instant Savings program, which replaced incandescent bulbs with CFLs. The analysis indicated that CFLs sold through Instant Savings had lower wattage than the incandescent bulbs they replaced.
Table 49: Peak Demand Savings Associated with the Introduction of Incandescent Bulbs Standards in the Nova Scotia Market Product Class Demand-to Diversity Total Peak Demand Savings Energy Ratio Factor at Meter for 2014 (MW) (%) (MW) Incand...
AI summary Table 49 presents peak demand savings from incandescent bulb standards in Nova Scotia. The data shows a total peak demand savings of 2.611 MW for incandescent bulbs (75 - 100W). Section 3.10 discusses LED street lighting, indicating a shift towards more energy-efficient lighting solutions.
3.10.1 Product Description Light emitting diode (LED) streetlights provide a more energy-efficient means to meet the street lighting requirements of Nova Scotia's municipalities. Many lighting manufacturers applied considerable development...
AI summary LED streetlights offer a more energy-efficient solution for Nova Scotia's municipalities. The technology has advanced significantly due to development efforts by lighting manufacturers.
3.10.2 Regulation Description In May of 2011, the province passed legislation requiring lighting on Nova Scotia roads and highways to be converted to LED lighting. At present, Nova Scotia is the first Canadian province to convert its exist...
AI summary In May 2011, Nova Scotia passed legislation requiring the conversion of street lighting to LED. The province is the first in Canada to complete this conversion, with Nova Scotia Power and municipalities having until December 31, 2022, to replace all street lights as they require maintenance.
3.10.3 Market Size Estimate In 2009, the Union of Nova Scotia Municipalities (UNSM) commissioned DMD & Associates Ltd.70 to prepare "Energy Efficient Street Lighting Strategies for Nova Scotia Municipalities." As part of this work, a compl...
AI summary In 2009, the Union of Nova Scotia Municipalities commissioned DMD & Associates Ltd. to compile an inventory of all streetlights in Nova Scotia, totaling 135,964 lights, as part of an energy-efficient street lighting strategy.
Type Energy Consumption Range for an Average Month (kWh/month) Proportion of Inventory Proportion of Total Power Consumed High pressure sodium From 32 to150 82% 73.5% Mercury vapour From 43 to363 12% 16.0% Metallic additive From 50 to360 2...
AI summary Table 50 provides an inventory of existing lighting units in Nova Scotia as of 2009, categorizing them by type, energy consumption ranges, and their proportion of total inventory and power consumed.
3.10.4 Portion of the Market Impacted by the Regulation In its report, DMD & Associates Ltd. estimated that total street lighting consumption in 2009 was 88,886,988 kWh. This would work out to an average consumption per light unit of 653.8...
AI summary The text discusses the impact of regulations on street lighting energy consumption in Nova Scotia, referencing data from DMD & Associates Ltd. and Nova Scotia Power. It notes that energy savings estimates are hindered by incomplete data on replaced units and varying efficiency levels.
3.10.5 Unitary Savings Values The Evaluator presumes Nova Scotia Power replaced the least efficient units first (i.e., with a higher energy consumption than the average consumption of the existing lighting units in Nova Scotia). The total...
AI summary The Evaluator assumes Nova Scotia Power replaced the least efficient lighting units first, using an average consumption of 653.8 kWh per lamp for 12,052 replaced units, resulting in a total energy consumption of 7,891,041 kWh. A literature review was conducted to estimate the energy use reduction from LED replacements.
Table 51: Literature Review of LED Street Lighting Study Cases Baseline – Existing Fixture Minimum Savings Maximum Savings Average Savings Source High pressure sodium 100 W 0% 41% 24% Streetlights for local roads, National Lighting Product...
AI summary Table 51 presents a literature review of LED street lighting study cases, comparing energy savings from high pressure sodium fixtures to LED replacements. The table includes baseline fixtures, minimum, maximum, and average savings percentages, along with sources from various studies conducted between 2010 and 2013.
3.10.6 At-meter Energy Savings The estimation of energy savings related to the installation of 12,052 units totalled 2.758 GWh, as shown in the table below.
AI summary The estimation of energy savings from the installation of 12,052 units is reported as 2.758 GWh, as presented in a table.
Table 52: Energy Savings Associated with the Introduction of the LED Street Lightings in the Nova Scotia Market Product Class Number of Lighting Annual Energy Total Incremental Energy Units Replaced Savings Savings at Meter for 2014 in 201...
AI summary Table 52 presents energy savings from the introduction of LED street lighting in Nova Scotia, showing 12,052 units replaced in 2014 with annual energy savings of 2.758 GWh. Section 3.10.7 discusses at-meter peak demand savings associated with this transition.
The Econoler team estimates that 0.689 MW was saved at the meter in Nova Scotia in 2014 as a result of introducing LED street lightings. As shown in the table below, the diversity factor of 100 percent was considered because savings always...
AI summary The Econoler team estimates that 0.689 MW was saved at the meter in Nova Scotia in 2014 due to the introduction of LED street lighting, with a diversity factor of 100 percent considered as savings occurred during the winter peak load.
Table 53: Demand Savings Associated with the Introduction of the LED Street Lightings in the Nova Scotia Market Product Class Number of Lighting units Replaced in 2014 Demand Savings (W/unit) Diversity Factor (%) Total Peak Demand Savings...
AI summary Table 53 presents demand savings from the introduction of LED street lighting in Nova Scotia in 2014, showing 12,052 units replaced, with a demand savings of 57 W/unit and total peak demand savings of 0.689 MW.
3.11.2 Regulation Description The 2010 edition of the National Building Code of Canada introduced a new section to Part 9 (Houses and Small Buildings) in 2012 called "Section 9.36. Energy Efficiency". This section was adopted to replace th...
AI summary In 2012, the 2010 edition of the National Building Code of Canada introduced a new section on energy efficiency for houses and small buildings, replacing the previous Nova Scotia Building Code Regulations. This update aligned Nova Scotia with national energy efficiency standards and was developed with input from various stakeholders.
3.11.5 At-meter Energy Savings The Evaluator estimates that the introduced regulation regarding residential market generated 0.779 GWh in energy savings in Nova Scotia for 2014.
AI summary The Evaluator estimates that the introduced regulation regarding residential market generated 0.779 GWh in energy savings in Nova Scotia for 2014.
Peak demand savings are calculated using an on-peak demand-to-energy ratio of 0.257 MW/GWh. This ratio was established based on a weighted-average ratio of modelled system-coincident peak demand savings and energy savings for a projected d...
AI summary Peak demand savings are calculated using a ratio of 0.257 MW/GWh, based on a weighted average from modelled system-coincident peak demand and energy savings projections in Nova Scotia. The Evaluator estimates that the introduced regulation generated 0.202 MW in energy savings in 2014.
Table 58: Overall Energy and Peak Demand Savings for Codes and Standards Ca Pr du t te o c g or y E ic M le tr c to o rs Ge l ne ra Se ice rv In de t ca n sc en Re f le to c r La m p s Dr ty y- p e fo tra ns rm er s La A ir rg e Co d i io...
AI summary Table 58 presents overall energy and peak demand savings for various codes and standards, including data on energy efficiency, lighting, heating, and building regulations. The table provides numerical values for energy savings and peak demand reductions across multiple categories.
BIBLIOGRAPHY & REFERENCES Canadian Standards Association, Minimum efficiency for dry-type transformers , http://www.hammondpowersolutions.com/upload_files/csa_c802%202-2006.pdf, January 23, 2007, p. 6. Caneta Research, Commercial Refrigera...
AI summary The document provides a bibliography and references section containing various studies, market analyses, and regulatory bulletins related to energy efficiency, transformer standards, and standby power use. These references are used for regulatory and policy-making purposes.
INTRODUCTION (2 minutes) - Thank respondent - Self-introduction by interviewer and colleague - Introduction of ENSC study Goal: The objective is to quantify the impact of 10 standards (introduced in 2012) on the Nova Scotia market in terms...
AI summary The introduction of an ENSC study aims to assess the impact of 10 energy efficiency standards introduced in 2012 on the Nova Scotia market. The interview is brief and focuses on identifying key individuals for further information.
DISCUSSION Here is a list of the standards we would like to evaluate: - a) Electric Induction Motors (CAN/CSA 390-10) - b) Incandescent Reflector Lamps from 40W up to 205W (CAN/CSA 862-09) - c) Incandescent Lamps 75 W and 100W (CAN/CSA C87...
AI summary The discussion involves evaluating various energy efficiency standards and inquiring about their implementation, compliance rates, and the availability of updated research or studies related to these standards. Questions are raised regarding the need for additional information sources, follow-up on compliance, and the availability of new studies or reliable sources of information.
INTRODUCTION - › Thank respondent - › Self-introduction by interviewer and colleague - › Introduction of ENSC study Goal: The objective is to quantify the impact of specific standards introduced in Canada in 2012 in terms of energy savings...
AI summary The objective of the ENSC study is to quantify the impact of specific Canadian energy efficiency standards introduced in 2012 on the Nova Scotia market, focusing on products such as electric induction motors, transformers, and LED street lights.
NOVA SCOTIA MARKET [ASK QA5 TO QA12 IF YES IN QA1] - 5. To provide us with a benchmark, how many [STANDARD/PRODUCT] were sold in Nova Scotia in 2013? [RECORD IN RELEVANT TABLE A] - 6. And how many do you anticipate will be sold in 2014? [R...
AI summary The text outlines a set of questions related to the market for specific standards or products in Nova Scotia, focusing on sales numbers, market trends, and compliance with energy efficiency codes implemented in 2012. The questions aim to assess market size, changes in sales projections, and the impact of regulatory standards on product compliance.
CANADIAN MARKET [ASK QA13 TO QA21 IF NO IN Q1] - 13. To provide us with a benchmark, how many [STANDARD/PRODUCT] were sold Canada in 2013? [RECORD IN RELEVANT TABLE C] - 14. And how many do you anticipate will be sold in 2014? [RECORD IN R...
AI summary The text outlines a series of questions related to the Canadian market for a specific standard or product, focusing on sales figures, market trends, compliance with energy efficiency codes, and the impact of regulatory standards on product compliance. Questions are directed at understanding historical and projected market data and the influence of regulatory changes.
ELECTRIC INDUCTION MOTORS 1 TO 500 HP (CAN/CSA 390-10) TABLE A: NOVA SCOTIA MARKET SIZE Electric Motors 1 to 500 HP Q7.Number of units sold in Nova Scotia in 2013 (actual) Q8. Number of units sold in Nova Scotia in 2014 (projected) Electri...
AI summary The text presents tables outlining the market size and expected compliance rates for electric induction motors in Nova Scotia and Canada for 2013 and 2014. The tables categorize motors by horsepower ranges and include projected and actual sales data.
SELF-CONTAINED COMMERCIAL REFRIGERATORS, FREEZERS AND REFRIGERATOR-FREEZERS (HRAI Standard 1200-2008) TABLE A: NOVA SCOTIA MARKET SIZE Self-contained commercial refrigerator, freezers and refrigerator-freezers Q7.Number of units sold in No...
AI summary The document presents tables outlining the market size and expected compliance rates for self-contained commercial refrigerators, freezers, and refrigerator-freezers in Nova Scotia and Canada for the years 2013 and 2014. The data includes actual and projected numbers of units sold and compliance rates.
COMMERCIAL AND INDUSTRIAL UNITARY AIR CONDITIONERS (CAN/CSA 746-2006) TABLE A: NOVA SCOTIA MARKET SIZE Commercial and industrial unitary air conditioners Number of units sold in Canada in 2013 (actual) Number of units sold in Canada in 201...
AI summary The text presents tables related to the market size of commercial and industrial unitary air conditioners in Nova Scotia and expected compliance rates in Canada for 2014. It categorizes air conditioners by size and includes projected sales figures.
TABLE B: EXPECTED COMPLIANCE RATE IN NOVA SCOTIA (2014) Stand-by power consumption Expected compliance rate for 2014 Integrated stereo Portable audio Televisions Non-recording video players Recording video players TABLE C: CANADA MARKET SI...
AI summary The text contains multiple tables outlining expected compliance rates and market sizes related to stand-by power consumption and external power supply in Nova Scotia and Canada for 2013 and 2014. These tables include categories like integrated stereo, portable audio, televisions, and various power supply classes.
TABLE D: EXPECTED COMPLIANCE RATE IN CANADA (2014) LED street lights Expected compliance rate for 2014 ? ? ?
AI summary The document includes a table titled 'Expected Compliance Rate in Canada (2014)' focusing on LED street lights, but the table lacks specific data entries, indicated by question marks.